Search NASASearch

SEARCH · Search NASA

Results for “Heat affected zones”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

311 records · Page 7

NASA Aerospace Flight Battery Systems Program

The major objective of the NASA Aerospace Flight Battery Systems Program is to provide NASA with the policy and posture to increase and ensure the safety, performance and reliability of batteries for space power systems. The program plan has been modified in the past year to reflect changes in the agency's approach to battery related problems that are affecting flight programs. Primary attention in the Battery Program is being devoted to the development of an advanced nickel-cadmium cell design and the qualification of vendors to produce cells for flight programs. As part of a unified Battery Program, the development of a nickel-hydrogen standard and primary cell issues are also being pursued to provide high-performance NASA Standards and space qualified state-of-the-art primary cells. The resolution of issues is being addressed with the full participation of the aerospace battery community.

Manzo, Michelle A.

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

drinking water

Boundary Layer Analysis of Shock Tube Flows

Shock tubes offer a controlled environment to reproduce kinetic and radiative phenomena characteristic of atmospheric entry flows under ground-test conditions. The boundary layer developing behind the incident shock wave determines the available test time, influences particle residence times important for similarity scaling, and can affect radiative energy transport. In this study, we couple a quasi-1D space marcher with the compressible boundary-layer equations to numerically compute the post-shock flow in a shock frame of reference for various test gas mixtures representative of different planetary atmospheres. The solvers are individually verified against CFD simulations and analytical correlations available in the literature. Coupled solutions are computed for a finite-rate chemistry in the boundary layer and a non-catalytic isothermal wall. Results yield refined estimates of the maximum separation distance, as well as insights into concentration profiles of relevant species within the boundary layer.

Andrea Fagnani

Hot Water, Cold Reality: Experimental Analysis of Sorption Constraints in Iodine Filtration Media Under Heated-Water Conditions

Iodine has been widely employed as a residual biocide in potable water applications during crewed missions. Unlike other biocides, it is essential to remove iodine from drinking water prior to consumption, as its biocidal concentration raises health concerns. Consequently, effectively removing iodine species from water is a critical step in potable water processing. Although the non-biocided heated leg has not violated microbial specifications on the International Space Station, any wetted volume lacking biocide presents potential risks for long‑duration exploration missions and for systems that are sensitive to microbial growth/contamination. Recent assessments indicate, however, that iodine‑removal performance may degrade under elevated temperature conditions, such as those required for dispensing hot water for food preparation. This reduction in efficacy appears to stem from both the potential physical degradation of filtration media and the temperature‑dependent behavior of adsorption processes. To investigate the influence of water temperature on the efficacy of filtration media for iodine removal, a series of adsorption capacity tests were conducted at both room temperature and elevated temperatures (90 °C). These experiments aimed to benchmark the performance of the adsorbents that constitute the ACTEX filter in the ISS’s potable water dispenser. The findings of this study provide critical insights into the iodine filtration process, verify the potential performance shortfall under elevated temperature conditions, and establish the basis for defining new absorbent requirements to ensure reliable iodine removal in future mission architectures.

iodine

Ground Slope Effects on Lander Radiator Performance

Two sensitivity studies were performed to examine the drop in radiator heat rejection from slopes. Study #1 used a 5.5m tall reduced order asset to represent a small-lander/rover. Study #2 used a 20m asset represent a tall lander. The assets had body mounted horizontal, 45º inward-tilted, and vertical radiator orientations. The impact of slopes on different radiator orientations and on radiators pointing different directions (i.e., slope verses sun) was investigated. The studies were conducted at a polar location of -82.5ºS to capture the incident solar flux at the northmost, and therefore the hottest, range of potential Artemis landing sites (Mons Mouton Plateau).

Lunar Slope

Numerical Predictions of the Flow and Heat Transfer Characteristics in the Film Boiling Regime During Tube Quenching

Cryogenic fluid management plays a major role in refueling of spacecrafts while in space for NASA’s future human space exploration missions. Due to the low boiling points of cryogens, storage, transport and handling of these fluids becomes difficult and may result in inefficient operation of the space propulsion systems. For refueling applications in space, the cryogenic fluids have to be transported across different locations and hence, the transfer of cryogenic fluids through pipes become critical. The cryogenic chill-down process is characterized by different regimes of flow boiling, viz., film boiling, transition boiling and nucleate boiling. The prediction of these regimes in a single CFD framework available in the literature is challenging and the present work attempts to address this challenge by initially modeling the film boiling regime accurately and to incorporate an user-defined function for transition and nucleate boiling at a later stage. Hence, the aim of the present work is to numerically model and validate the film boiling regime of the chilldown curve for liquid nitrogen experiments available in the literature. The validations are carried out at different inlet mass fluxes to have a robust simulation methodology. A dispersed mixture model is used to predict the vapor-liquid interface dynamics with the phase change phenomena modeled using the Lee model.

line chilldown

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator

Performance of Solar Reflectors When Applied to Storage of Cryogenic Propellants in Space

An analysis was performed to determine the effectiveness of solar reflectors in reducing heat transfer through the insulation of cryogenic fuel tanks located in deep space. A solar reflector, as used herein, is defined as a surface having a ratio of absorptance with respect to solar radiation to hemispherical emittance (α/ϵ) less than 1.0. This analysis considers the effect of surface coatings with α/ϵ values varying from 0.1 to 1.0 when applied to the external surfaces of bulk insulation or multifoil insulation. Results were obtained in terms of heat leak to two cryogenic propellants, liquid hydrogen and liquid oxygen, when stored at Mars, Earth, and Mercury orbital distances from the sun. The results show that, with sufficiently good insulation and low heat leaks to the propellant, α/ϵ is a reasonable criterion of merit for these coatings, but that, at larger heat leaks, consideration of ϵ (or α) is necessary. It was observed that selective finishes of α/ϵ = 0.1 on a given amount of bulk insulation material can reduce the heat leak to 40 to 55 percent of the heat leak obtained when gray finishes are considered. Or, for equivalent heat leaks, a reduction in bulk insulation material thickness of about one-half is possible with high-quality selective finishes (α/ϵ = 0.1) compared with flat reflectors. Larger benefits may be achieved from selective finishes painted on foils; the analysis shows that heat leak may be reduced tenfold for surfaces with an α/ϵ of 0.1 compared with gray surfaces. Again, consideration of equivalent heat leaks indicates that the use of approximately 10 times fewer foils of emissivity 0.05 is possible when spectrally selective surfaces are employed. The present state of the art in achieving such surfaces is also briefly reviewed.

Propellant Storage

An Overview of CMIP5 and CMIP6 Simulated Cloud Ice, Radiation Fields, Surface Wind Stress, Sea Surface Temperatures and Precipitation over Tropical and Subtropical Oceans

The potential links between ice water path (IWP), radiation, circulation, sea surface temperature (SST) and precipitation over the Pacific and Atlantic Oceans resulting from the falling ice radiative effects (FIREs) are examined from present day model outputs of CMIP5 and CMIP6. The latter is divided into two subsets with (SON6) and without FIREs (NOS6) as more models with FIREs are included in CMIP6 than in CMIP5. Improvement in floating cloud ice (~20 g m-2) is noticeable over convective regions in CMIP6 relative to CMIP5. The inclusion of FIREs in SON6 subset may contribute to reduce biases of overestimated outgoing longwave radiation and downward surface shortwave and overestimated reflected shortwave at the top of the atmosphere (TOA) by magnitudes of 4?8 W m-2 over convective regions against CERES, compared to NOS6 subset. The reduced biases in radiative fluxes in convective regions stabilize the atmosphere and lead to circulation, SST, cloud and precipitation changes over the trade-wind regions, as seen from improved radiative fluxes (4?15 W m-2), surface wind stress biases, SST (0.2?0.8 K) and precipitation (1 mm day-1) biases. The significant improvement from NOS6 to SON6 leads to improved multi-model means for CMIP6 relative to CMIP5 for radiation fields over the trade wind regions but the degradation over convective zones is attributed to NOS6 subset. The results suggest that other sources of uncertainty and deficiencies in climate models may play significant roles for reducing discrepancies although FIREs, via radiation-circulation coupling, may be one of the factors that help to reduce regional biases.

Jui-Lin F Li

CH3OH and HCN in Interstellar Comet 3I/ATLAS Mapped with the ALMA Atacama Compact Array: Distinct Outgassing Behaviors and a Remarkably High CH3OH/HCN Production Rate Ratio

We report the detection of methanol (CH3OH) toward interstellar comet 3I/ATLAS using the At-acama Compact Array of the Atacama Large Millimeter/Submillimeter Array (ALMA) on UT 2025 August 28, September 18 and 22, and October 1, and of hydrogen cyanide (HCN) on September 12 and 15. These observations spanned pre-perihelion heliocentric distances (r H ) of 2.6 – 1.7 au. The molecules showed outgassing patterns distinct from one another, with HCN production being depleted in the sunward hemisphere of the coma, whereas CH3OH was enhanced in that direction. Statistical analysis of molecular scale lengths in 3I/ATLAS indicated that CH3OH included production from coma sources at Lp > 258 km at 99% confidence. However low signal-to-noise on long baselines, which sample emission on small spatial scales closest to the nucleus, prevented definitively ruling out CH3OH as purely a parent species. In contrast, HCN production was indistinguishable from direct nucleus sublimation. The CH3OH production rate increased sharply from August through October, including an uptick near the inner edge of the H2O sublimation zone at rH = 2 au. Compared to comets measured to date at radio wavelengths, the derived CH3OH/HCN ratios in 3I/ATLAS of 124+30−34 and 79+11−14on September 12 and 15, respectively, are among the most enriched values measured in any comet, surpassed only by anomalous solar system comet C/2016 R2 (PanSTARRS)

Comae

Cryogenic Spray Quenching of A Simulated Propellant Storage Tank Wall With Heat Transfer Enhancement By A Thin-Film Coating and Flow Pulsing in Microgravity

Human space exploration to the Moon, Mars, and possibly asteroids is NASA’s biggest challenge for the new millennium. One of the critical elements to this mission is the effective, sufficient, and reliable supply of cryogenic propellant fluids. Future lower-earth-orbiting (LEO) propellant fuel depots and human-carrying orbital transfer spacecraft flying to the moon and Mars will have to utilize the high thrust and high efficiency of liquid cryogenic chemical propulsion or nuclear thermal propulsion. Efficient in-space tank-to-tank propellant transfer (propellant fuel depot to orbital transfer spacecraft) of cryogenic propellants is an enabling technology for the planned Crewed Mars Surface Mission. The transfer of cryogenic propellants in space, however, has yet to be accomplished, solely due to the unavailability of cryogenic quenching heat transfer data during chilldown (quenching) and filling of the propellant receiver tank in reduced gravity and microgravity as liquid propellant cannot be stored in a required liquid state until the tank is quenched down to the liquid temperature. Therefore, highly energy efficient thermal-fluid management breakthrough concepts to conserve and minimize the cryogen consumption during propellant transfer have become the focus of research and engineering development, especially for the deep-space mission to Mars. In this paper, we introduce such concepts and demonstrate their feasibility for cryogenic storage tank chilldown in parabolic flights under a simulated space microgravity condition. In order to maximize the storage tank chilldown efficiency for the least amount of cryogen consumption, the technology adopted included cryogenic spray cooling, Teflon thin-film coating of the simulated tank surface, and spray flow pulsing. The completed flight experiments successfully demonstrated that spray cooling is the most efficient cooling method for the tank chilldown in microgravity. In microgravity, Teflon coating alone can improve the efficiency up to 72% and the efficiency can be improved up to 59% by flow pulsing alone. However, Teflon coating together with flow pulsing was found to substantially enhance the chilldown efficiency in microgravity for up to 113%.

spray

Metallurgical and Thermal Properties of 57Ni-40Ti-3Hf (wt%)

Selected properties of 57Ni-40Ti-3Hf (wt%) were measured to further develop this material for use in aerospace rolling-element bearings. The average grain size and microindentation hardness of the material at room temperature were 90 μm and 549 HV, respectively. From room temperature to 500 °C, electrical resistivity increased from 8.9×10–7 to 11.3×10–7 Ω⋅m, thermal expansion coefficients varied from 1.1×10–5 to 1.2×10–5 mm/mm⋅°C, specific heat increased from 0.44 to 0.53 W⋅sec/g⋅K, thermal diffusivity rose from approximately 0.003 to 0.005 cm2/sec and thermal conductivity increased from approximately 0.09 to 0.19 W/cm⋅K. The behavior of the material can be explained by well-known metallurgical theory. These results are expected to provide a basis for design and modeling of future aerospace components.

rule of mixtures

Long-Term Evaluation of Landsat 9 Oli Data Product Uniformity at Focal Plane Module-Boundaries Using Earth Scenes

The uniformity performance characteristic in remote sensing data products is a metric that helps evaluate how an image accurately represents radiometric responses to geophysical variability at the Earth’s surface or within the atmosphere. These uniformity attributes are used in Earth remote sensing science applications such as investigating water quality, land-cover/land-use classifications, and crop health assessments. To ensure these applications perform effectively, it is crucial to maintain and regularly assess the uniformity of calibrated remote sensing data products. In the Landsat missions, data from the onboard radiometric reference Solar diffuser device are used as the standard approach to derive the calibration parameters, ensuring the maintenance of both absolute radiance and radiometric uniformity through quarterly updates. This publication presents an alternative approach that leverages Earth scene data to assess the on-orbit uniformity performance of the Landsat 9 (L9) mission. The analysis characterizes uniformity at a specific set of spatial positions (the focal-plane boundary zones) that are intrinsic to the Operational Land Imager (OLI) focal plane design. By employing these Earth data statistics, the article further explores the temporal trends in the radiometric uniformity results. The results shown in this article demonstrate that for pushbroom imaging design systems with staggered sensor chip focal plane architectures, the co-registered pixels, i.e., overlapping measurements of the same ground target viewed by different detectors, offer a self-contained mechanism for assessing product uniformity. Remarkably, this alternative approach achieves a level of radiometric quality comparable to that delivered by a stable, well-characterized onboard Solar diffuser calibration device. The findings demonstrate the potential and capability of such Earth scene statistics in maintaining radiometric uniformity in calibrated data products to better than 1% (1-sigma) throughout the mission’s operational lifetime.

trend

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Spacecraft thermal margins depend on the temperature penalty of installed interfaces, yet catalog conductivity omits bondline thickness, mating surfaces, preload, and environment. The Testbed for Advanced Interface Materials in Vacuum (TAIMV) addresses this engineering-data gap by converting ambient/vacuum temperature fields from a four-coupon stack into quantities usable in spacecraft thermal models. Its 17-node steady-state model resolves axial conduction, parasitic fixture paths, grease-filled contact, radiation, and ambient convection. Four monolithic checks gave axial heat-rate ratios of 0.90–1.02, and Braycote calibration self-recovery gave 2.20% casewise mean absolute percentage error (MAPE) and 2.85% maximum difference. With transferable fixture terms frozen, Krytox LVP tested cross-material transfer against a manufacturer-derived external relation. The six Krytox cases gave 2.28% MAPE, 5.10% maximum difference, and full-field residual root-mean-square values of 0.553 °C ambient and 1.306 °C vacuum. Installed-joint resistance spanned 6.39–7.15 × 10⁻⁴ m²·K/W for Braycote and 4.09–4.49 × 10⁻⁴ m²·K/W for Krytox, corresponding to 2.33–6.66 K per modeled interface over the tested heat-flux range. TAIMV therefore supplies directly usable installed-joint resistance and conductance, plus apparent installed conductivity and explicitly model-conditioned grease conductivity/contact terms.

heat transfer

Thermochemically-Closed Sonic-Flow Inversion for Enthalpy and Temperature in Multispecies Arc-Jet Flows

A thermochemically-closed sonic-flow inversion framework (TSIF) is developed to infer bulk enthalpy and total temperature upstream of a choked nozzle in arc-jet flows. The formulation recasts a pressure-rise total enthalpy quantification technique as an inverse problem in characteristic-velocity c * space using measured mass flow rate, upstream total pressure, gas composition, and nozzle throat geometry as inputs. Unlike calorimetric energy-balance approaches or optical diagnostics, the method relies primarily on routinely measured facility quantities combined with explicit thermochemical closure. Thermochemical states are obtained using NASA’s open-source Chemical Equilibrium with Applications (CEA) code, enabling construction of a chemistry-consistent relation between characteristic velocity, total enthalpy, and total temperature under equilibrium or frozen assumptions. A discharge coefficient is self-calibrated using cold-flow (arc-off) operation data and applied to hot-flow (arc-on) measurements, enabling upstream losses to be accounted for without empirical correlations. The framework is applied to air, N 2 , and CO 2 –N 2 arc-jet flows and demonstrates expected trends for the inferred thermochemical states as function of arc power, specific energy input, mass-flow, heater configuration, and test gas. In the air limit, under equilibrium assumptions, the method recovers the classical high-enthalpy asymptotic correlation of Winovich with a mean residual of 4.4%, demonstrating compatibility with established sonic-flow scaling, while extending applicability to arbitrary multi-species mixtures and non-equilibrium chemistry. The framework provides a mixture-flexible methodology for determining bulk thermochemical states in modern arc-jet environments using routine facility pressure, mass-flow, gas-composition, and nozzle-geometry information together with a cold-flow calibration.

stagnation heat flux