Search NASA⌕ Search

SEARCH · Search NASA

Results for “IGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Geodynamics - Tracking satellites to monitor global change

The major goals and organizational structure of the International GPS Geodynamics Service (IGS), a new Navstar satellite tracking service, are described. IGS activities are aimed at providing the scientific community with data on GPS orbits accurate enough for performing regional and local GPS analysis and daily earth rotation information.

Beutler, Gerhard↗

Role of Thyroxine in Space-Developed Jellyfish

The Aurelia Metamorphosis Test System was previously used to determine the effects of the space environment on the development and behavior of tiny (1-2 mm) jellyfish ephyrae during the SLS-1 and IML-2 missions. Results from the SLS-1 experiment included the discovery that statolith numbers were significantly reduced in Earth-formed ephyrae flown for nine days in space as compared with ground-based controls. In addition, upon return to Earth, six times more ephyrae which had developed in space than those developed on Earth had pulsing abnormalities, indicating that either these animals did not form their neuromuscular structures normally while in space or they were unable to adapt to the Ig environment upon return to Earth. The metamorphosis process, which enables the formation of ephyrae from polyps is influenced by a hormone, Jf-T4 Oellyfish thyroxine) which is synthesized following iodine administration. Two groups of polyps in space, however, formed ephyrae without iodine administration indicating that Jf-T4 synthesis, utilization, or excretion was different in. the ephyrae. Increased synthesis or build-up in the media of the hormone may also be linked to the increased demineralization of statoliths found in space-exposed ephyrae. In previous experiments, we found that externally administered thyroxine causes increased demineralization of statoliths on Earth. Abnormal pulsina in ephyrae following return to Earth during the SLS-1 mission may also be traced to increased Jf-T4 levels. Thyroxine is known to be important to the normal development and function of the nervous system, heart, and skeletal muscles in higher animals. For this third Jellyfish-in-Space experiment, we proposed to quantitate the levels of Jf- T4 and of T4 receptors in space-developed ephyrae and media and to compare these levels with those of animals developing and at Ig in space and on Earth. We expected to be able to determine whether Jf-T4 synthesis and/or secretion is different in space-flownjellyfish than in controls and to determine which cells (nerve, muscle, lithocytes, etc.)may have enhanced Jf-T4 levels. However, NASA deselected this experiment in August, 1997.

Spangenberg, Dorothy B.↗

Clinical aspects of the control of plasma volume at microgravity and during return to one gravity

Plasma volume is reduced by 10-20% within 24-48 h of exposure to simulated or actual microgravity. The clinical importance of microgravity induced hypovolemia is manifested by its relationship with orthostatic intolerance and reduced maximal oxygen uptake (VO2max) after return to one gravity (1G). Since there is no evidence to suggest that plasma volume reduction during microgravity is associated with thirst or renal dysfunctions, a diuresis induced by an immediate blood volume shift to the central circulation appears responsible for microgravity-induced hypovolemia. Since most astronauts choose to restrict their fluid intake before a space mission, absence of increased urine output during actual space flight may be explained by low central venous pressure (CVP) which accompanies dehydration. Compelling evidence suggests that prolonged reduction in CVP during exposure to microgravity reflects a "resetting" to a lower operating point, which acts to limit plasma volume expansion during attempts to increase fluid intake. In ground based and space flight experiments, successful restoration and maintenance of plasma volume prior to returning to an upright posture may depend upon development of treatments that can return CVP to its baseline IG operating point. Fluid-loading and lower body negative pressure (LBNP) have not proved completely effective in restoring plasma volume, suggesting that they may not provide the stimulus to elevate the CVP operating point. On the other hand, exercise, which can chronically increase CVP, has been effective in expanding plasma volume when combined with adequate dietary intake of fluid and electrolytes. The success of designing experiments to understand the physiological mechanisms of and development of effective counter measures for the control of plasma volume in microgravity and during return to IG will depend upon testing that can be conducted under standardized controlled baseline conditions during both ground-based and space flight investigations.

Review, Tutorial↗

The International GPS Service: A Global Resource for GPS Applications and Research

Since June, 1992, the International GPS service has been coordinating a global civilian GPS infrastructure in order to support numerous GPS applications and research activities. A key aspect of the IGS is the reliability and quality of the analysis products that have been made available over the past five years through the IGS Analysis Centers and the Analysis Center Coordinator.

Applications and Research↗

The Effect of Seasonal and Long-Period Geopotential Variations on the GPS Orbits

We examine the impact of using seasonal and long-period time-variable gravity field (TVG) models on GPS orbit determination, through simulations from 1994 to 2012. The models of time-variable gravity that we test include the GRGS release RL02 GRACE-derived 10-day gravity field models up to degree and order 20 (grgs20x20), a 4 x 4 series of weekly coefficients using GGM03S as a base derived from SLR and DORIS tracking to 11 satellites (tvg4x4), and a harmonic fit to the above 4 x 4 SLR-DORIS time series (goco2s_fit2). These detailed models are compared to GPS orbit simulations using a reference model (stdtvg) based on the International Earth Rotation Service (IERS) and International GNSS Service (IGS) repro1 standards. We find that the new TVG modeling produces significant along, cross-track orbit differences as well as annual, semi-annual, draconitic and long-period effects in the Helmert translation parameters (Tx, Ty, Tz) of the GPS orbits with magnitudes of several mm. We show that the simplistic TVG modeling approach used by all of the IGS Analysis Centers, which is based on the models provided by the IERS standards, becomes progressively less adequate following 2006 when compared to the seasonal and long-period TVG models.

Orbit determination↗

International GPS Service : 2001-2002 technical reports

Applications of the Global Positioning System (GPS) to Earth Science are numerous. The International GPS Service (IGS), a federation of government agencies and universities, plays an increasingly critical role in support of GPS-related research and engineering activities. Contributions from the IGS Governing Board and Central Bureau, analysis and data centers, station operators, and others constitute the 2001 / 2002 Technical Reports.

Feltens, J.↗

HDG-1 Graphite Preirradiation Data Package Report

This report documents all pre-irradiation examination material-property measurement data for graphite specimens that are going to be used within the first high dose graphite (HDG) -1 irradiation capsule. The two new HDG capsules signify a major change to the AGC Experiment. HDG-1 and HDG-2 will replace the last two Advanced Graphite Creep (AGC) capsules (AGC-5 and AGC-6) which were designed to irradiate graphite at the extreme upper operational temperatures for a very-high-temperature reactor (VHTR) design, 1100°C. These very high temperature AGC-5 and AGC-6 capsules have been repurposed to re-irradiated specimens (from AGC-2, AGC-3, and AGC-4) at the lower temperatures of 600°C and 800°C. HDG-1 will be irradiated at 600°C and HDG-2 will be irradiated at 800°C. By re-irradiating the previous AGC specimens a total maximum neutron dose of around 15 dpa (displacements per atom) can be achieved for all major graphite grades at irradiation temperatures of 600°C and 800°C. Specimens in the HDG-1 capsule are made up of previously irradiated specimens from the AGC-2 capsule and unirradiated specimens prepared for the now discontinued AGC-5 capsule. Utilizing the irradiated specimens, a maximum neutron dose of around 15 dpa is anticipated. These new maximum dose levels will provide irradiated material property data over a total neutron dose range of 1-15 dpa at a temperature of 600°C when combined with the previous AGC-1 and AGC-2 irradiation data. This will provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within high temperature reactor designs. Similar to previous AGC test trains, HDG-1 includes the major graphite grades (IG-110, NBG-17, NBG-18, PCEA, and 2114) as well as adding the very fine-grain grade IG-430 which is of interest to the Molten Salt Reactor (MSR) designs. Also new to the HDG-1 capsule are 90 smaller geometry specimens designated as pencil specimens. These specimens take up only one third the space of a standard creep size specimen. This increased number of specimens will enhance property measurement statistics because they will provide 3 times the control specimen data at a position that would otherwise only have a single measurement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measurement of Fission Product Concentration Profiles in AGR-3/4 TRISO Fuel Graphitic Matrix and Nuclear Graphites

The third Advanced Gas Reactor (AGR) irradiation experiment, AGR-3/4, was designed to investigate the migration of fission products in fuel compact graphitic matrix and reactor graphite components. Using destructive methods, radial fission product concentration profiles were measured for gamma-emitting fission products (e.g., Ag-110m, Cs-134, and Eu-154) and beta-emitting Sr-90 in irradiated graphitic and graphite components from six different AGR-3/4 irradiation capsules. These new measured concentration profiles can now be compared to non-destructive measurements and fission product transport simulations and will be used to derive new diffusivities and sorptivities to support refinement of fission product transport models and high-temperature gas-cooled reactor (HTGR) source-term analyses. Each capsule in the AGR-3/4 experiment had four fuel compacts in the middle of two concentric rings of graphitic matrix material, PCEA graphite, or IG-110 graphite. In addition to the approximately 1898 tristructural isotropic (TRISO) coated particles in each compact, there were 20 designed to fail (DTF) particles coated only in pyrocarbon so that they released fission products into the surrounding cylindrical rings of carbonaceous materials. Destructive sampling of the rings involved machining/milling material from around the circumference of the rings, collecting that material, and performing radiochemical analyses on it. Milling operations were performed in multiple steps or segments, and each segment was generally 0.508 mm (0.020 in) thick. Knowing the radial position at which each segment was milled, the volume of the milled material at each segment, and the fission product content in each segment, the radial fission product concentrations were constructed for select isotopes in each ring. Ag-110m profiles had the most variation. Some profiles were peaked at an inner or outer surface. Some were peaked at the middle of the ring wall thickness. Some increased radially outward, and some decreased radially outward. These types of variations and the fact that the measured profiles do not generally compare favorably with the transport model employed for AGR-3/4 may adversely impact the ability to extract reasonable transport parameters for this isotope. In many cases, the Cs-134 profiles decreased somewhat linearly in the outward radial direction, and in cursory comparisons, the shapes of these profiles appeared similar to those from model predictions. The step changes in concentration across the inner-outer ring gap were generally consistent with the model predictions as well. In some cases, there were local maxima in concentration at the outer surface of the rings. This suggests that fission products could have transported in the small gaps between the inner ring and the outer ring and between the outer ring and the sink ring such that some portion of a given fission product can bypass diffusion through the ring itself. The analysis of the small nubs on the outer surfaces of some of the outer rings revealed fission product concentrations in the nubs that were often higher than in the outermost segments of the rings. This further supports the hypothesis that short-circuit, gap transport occurred, causing relatively high surface concentrations on the outer surfaces of the rings. Eu-154 and Sr-90 profiles tend to have very similar shapes, suggesting that they transport via the same mechanisms. The observed profiles were indicative of a transport process where the isotopes are sorbed on the inner surface of the ring, but diffusion into the ring from that surface is quite slow. Some elevated concentrations of Sr-90 (relative to Eu-154) on the outer surface of a ring suggested that rapid, gas-gap transport of gaseous precursor Kr-90 and volatile Rb-90 could have occurred prior to their decaying to Sr-90. Overall, the Eu 154 and Sr-90 profiles were still very similar, which indicates that the transport of short-lived Sr-90 precursors is not a major effect. In some capsules, the qualitative Sr-90 behavior across the ring gaps was consistent with the model (using the available legacy Sr-90 transport parameters), but in other capsules the model was inconsistent with the measurements and seems to underestimate the amount of Sr-90 in the outer rings. The total ring Sr-90 inventories were estimated for all the rings that were subject to physical sampling. These results will be used to adjust the predicted particle and/or compact releases used in the AGR-3/4 fission product transport model. Given the different irradiation temperatures among the capsules and the rings, it was not possible to discern fundamental differences in the transport of isotopes within the different carbon materials, i.e., graphitic matrix, IG-110, or PCEA. It may be possible to do this in the course of determining transport from the concentration profiles in future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Intergranular Oxidation of Unstressed Alloy 600 SA and Alloy 600TT in PWR Primary Water

Unstressed coupons of Alloy 600 SA (solution-annealed) and Alloy 600TT were exposed to simulated pressurized water reactor (PWR) primary water at 360oC. The depth of intergranular oxide penetration, as well as the microstructure and microchemistry associated with intergranular (IG) oxidation of selected samples, were characterized by SEM, serial FIB sectioning, TEM and APT. There is no clear trend to indicate that IG oxidation depths in unstressed coupons are different between Alloy 600 SA and TT. At the same time, all SA+TT materials examined evidenced significant interaction between oxidation and Cr-rich GB precipitates. In addition, the spatial extent of GB compositional changes ahead of the oxidation front (e.g. Cr depletion and Ni enrichment) appears different for Alloy 600 SA vs. SA+TT. In SA heats exposed for only 1000 h (42 days), the composition of some GBs changes over distances of 500–1000 nm. SA+TT materials appear not to develop such long-range GB compositional changes (10s nm alteration distances only).

Alloy 600, IGA, PWR, Oxidation, FIB, TEM, APT↗

AN UPDATE ON THE STATUS OF A REDUCED FLOW TEST OF A 10MW 700⁰C SCO2 INTEGRALLY GEARED COMPANDER

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700℃. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale CSP supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally-geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications.

14 SOLAR ENERGY↗

An Update on the Status of a Reduced Flow Test of a 10MW 700°C sCO2 Integrally Geared Compander

. In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700 degrees Celsius. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale concentrated solar power (CSP) supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications. As part of the commercialization of this technology, it is necessary to reduce risk by validation testing of key components. In the current work, the focus is developing a test loop to enable safe testing of the main compressor stage across a wide range of operating conditions, and to validate the mechanical integrity of the turbine at full pressure, temperature, and speed. Developing a test loop for sCO2 requires balancing a number of design alternatives that impact cost, lead time, safety, and performance. The current work discusses the design process for the reduced flow test loop for the compander, and supporting documentation supporting the viability of the test loop

wilkes, jason↗

HDG-1 Graphite Preirradiation Data Package Report

This report documents all pre-irradiation examination material-property measurement data for graphite specimens that are going to be used within the first high dose graphite (HDG) -1 irradiation capsule. The two new HDG capsules signify a major change to the AGC Experiment. HDG-1 and HDG-2 will replace the last two Advanced Graphite Creep (AGC) capsules (AGC-5 and AGC-6) which were designed to irradiate graphite at the extreme upper operational temperatures for a very-high-temperature reactor (VHTR) design, 1100°C. These very high temperature AGC-5 and AGC-6 capsules have been repurposed to re-irradiated specimens (from AGC-2, AGC-3, and AGC-4) at the lower temperatures of 600°C and 800°C. HDG-1 will be irradiated at 600°C and HDG-2 will be irradiated at 800°C. By re-irradiating the previous AGC specimens a total maximum neutron dose of around 15 dpa (displacements per atom) can be achieved for all major graphite grades at irradiation temperatures of 600°C and 800°C. Specimens in the HDG-1 capsule are made up of previously irradiated specimens from the AGC-2 capsule and unirradiated specimens prepared for the now discontinued AGC-5 capsule. Utilizing the irradiated specimens, a maximum neutron dose of around 15 dpa is anticipated. These new maximum dose levels will provide irradiated material property data over a total neutron dose range of 1-15 dpa at a temperature of 600°C when combined with the previous AGC-1 and AGC-2 irradiation data. This will provide quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades for use within high temperature reactor designs. Similar to previous AGC test trains, HDG-1 includes the major graphite grades (IG-110, NBG-17, NBG-18, PCEA, and 2114) as well as adding the very fine-grain grade IG-430 which is of interest to the Molten Salt Reactor (MSR) designs. Also new to the HDG-1 capsule are 90 smaller geometry specimens designated as pencil specimens. These specimens take up only one third the space of a standard creep size specimen. This increased number of specimens will enhance property measurement statistics because they will provide 3 times the control specimen data at a position that would otherwise only have a single measurement.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Structural and functional characterization of IgG- and non-IgG-based T-cell-engaging bispecific antibodies

Bispecific T-cell-engaging antibodies are a growing class of therapeutics with numerous molecules being tested in clinical trials and, currently, seven of them have received market approval. They are structurally complex and function as adaptors to redirect the cytotoxicity of T cells to kill tumor cells. T-cell-engaging bispecific antibodies can be generally divided into two categories: IgG/IgG-like and non-IgG-like formats. Different formats may have different intrinsic potencies and physiochemical properties, and comprehensive studies are needed to gain a better understanding of how the differences in formats impact on structural and functional characteristics. In this study, we designed and generated bispecific T-cell-engaging antibodies with IgG-like (DVD-Ig) and non-IgG (BiTE) formats. Both target the same pair of antigens (EGFR and CD3) to minimize the possible influence of targets on functional characterization. We performed a side-by-side comparison to assess differences in the physiochemical and biological properties of these two bispecific T-cell-engaging antibodies using a variety of breast and ovarian cancer cell-based functional assays to delineate the structural–functional relationships and anti-tumor activities/potency. We found that the Fc portion of T-cell-engaging bispecific antibodies can significantly impact antigen binding activity, potency, and stability in addition to eliciting different mechanisms of action that contribute the killing of cancer cells.

cluster of differentiation 3 (CD3)↗

Review of Graphite Properties Relevant to Micro-Reactor Design

Microreactors are advanced reactors that are designed to be small, scalable, and portable with up to 20 MW power. These reactors could operate independently, or as part of a microgrid, without need of a frequent refueling. Micro-reactors are designed to be deployable to provide electric power in remote locations, therefore providing greater flexibility. Several micro-reactors are under development in the US. These reactors are based on advanced gas-cooled or heat-pipe concepts. While Graphite can be found in various applications, some high-temperature reactors plan to employ Graphite in their core components due to its role as a moderator and its ability to maintain its structural integrity when subjected to elevated temperatures and high neutron fluence. Although there is significant experience with use of Graphite in nuclear applications, there are still unknowns that should be addressed. Graphite properties depend on the graphite type and affected by the fabrication procedures. Material properties are functions of the temperature and irradiation dose. The fundamental properties also affected by the oxidation environment. Therefore, in-depth understanding of graphite properties, including the effect of irradiation, oxidation and other influencing parameters are required to evaluate the design accurately. This draft aims to provide a comprehensive review of material properties for Graphite relevant to micro reactor design. For this work, two distinct grades of graphite were considered, namely IG-110 and Mersen-2114. Physical, thermal, and mechanical properties for these grades were comparatively evaluated. The properties that are discussed in this draft aim to serve as a basis for design and safety analysis.

42 ENGINEERING↗

Measuring success for a future vision: Defining impact in science gateways/virtual research environments

Scholars worldwide leverage science gateways/virtual research environments (VREs) for a wide variety of research and education endeavors spanning diverse scientific fields. Evaluating the value of a given science gateway/VRE to its constituent community is critical in obtaining the financial and human resources necessary to sustain operations and increase adoption in the user community. In this article, we feature a variety of exemplar science gateways/VREs and detail how they define impact in terms of, for example, their purpose, operation principles, and size of user base. Further, the exemplars recognize that their science gateways/VREs will continuously evolve with technological advancements and standards in cloud computing platforms, web service architectures, data management tools and cybersecurity. We also present a number of technology advances that could be incorporated in next-generation science gateways/VREs to enhance their scope and scale of their operations for greater success/impact. The exemplars are selected from owners of science gateways in the Science Gateways Community Institute (SGCI) clientele in the United States, and from the owners of VREs in the International Virtual Research Environment Interest Group (VRE-IG) of the Research Data Alliance. Thus, community-driven best practices and technology advances are compiled from diverse expert groups with an international perspective to envisage futuristic science gateway/VRE innovations.

97 MATHEMATICS AND COMPUTING↗

Integrated structural model of the palladin–actin complex using XL ‐ MS , docking, NMR , and SAXS

Abstract Palladin is an actin‐binding protein that accelerates actin polymerization and is linked to the metastasis of several types of cancer. Previously, three lysine residues in an immunoglobulin‐like domain of palladin have been identified as essential for actin binding. However, it is still unknown where palladin binds to F‐actin. Evidence that palladin binds to the sides of actin filaments to facilitate branching is supported by our previous study showing that palladin was able to compensate for Arp2/3 in the formation of Listeria actin comet tails. Here, we used chemical crosslinking to covalently link palladin and F‐actin residues based on spatial proximity. Samples were then enzymatically digested, separated by liquid chromatography, and analyzed by tandem mass spectrometry. Peptides containing the crosslinks and specific residues involved were then identified for input to the HADDOCK docking server to model the most likely binding conformation. Small‐angle x‐ray scattering was used to provide further insight into palladin flexibility and the binding interface, and NMR spectra identified potential interactions between palladin's Ig domains. Our final structural model of the F‐actin:palladin complex revealed how palladin interacts with and stabilizes F‐actin at the interface between two actin monomers. Three actin residues that were identified in this study also appear commonly in the actin‐binding interface with other proteins such as myotilin, myosin, and tropomodulin. An accurate structural representation of the complex between palladin and actin extends our understanding of palladin's role in promoting cancer metastasis through the regulation of actin dynamics.

Sargent, Rachel [Department of Chemistry and Bioch↗