Results for “Infrared Sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Observtion of Carbon Monoxide and Ozone from 2019-2020 Australia Fires Using Thermal Infrred and Near-Infrared Satellite Sensors

The Single Field-of-View (SFOV) retrieval products from CrIS on SNPP have a spatial resolution of 14 km. These products include temperature, water vapor, clouds and trace gases, such as ozone (O3) and carbon monoxide (CO). Such high-resolution sounder products enable us to make process-oriented analysis of CO emission and transport from Australia’s unprecedented wildfires as well as the O3 production along the transport of fire plumes in the end of 2019 to early 2020. Comparisons of CO with other satellite products, such as AIRS, TROPOMI and MOPPIT, show a good agreement of CO from these space-borne observations. The mean difference SFOV total CO with TROPOMI CO is 0.22%14.0% (R=0.92) and 1.1%17.6% (R=0.87) using data on December, 30, 2019 and January 1, 2020, respectively. This study also demonstrates the advantage of the SFOV CO in capturing the feature of CO transport for air quality study.

Xiaozhen Xiong↗

Observation of Carbon Monoxide and Ozone from 2019-2020 Australia Fires Using Thermal Infrared and Near-Infrared Satellite Sensors

The Single Field-of-view Sounder Atmospheric Products (SiFSAP), including ozone (O3) and carbon monoxide (CO), from CrIS on SNPP have a spatial resolution of about 14 km. Such high-resolution sounder products enable us to make process-oriented analysis of CO emission and transport from biomass burning as well as the O3 production along the transport of fire plumes from large wildfires. An analysis of SiFSAP CO from Australia’s unprecedented wildfires in the end of 2019 to early 2020 and comparison with other satellite products, such as TROPOMI and MOPPIT, demonstrate a good agreement of CO observations among these space-borne sensors. This study also demonstrates the advantage of the SiFSAP CO in capturing the feature of CO transport and O3 production from wildfires, which will benefit air quality study.

Xiaozhen Xiong↗

Photoelectric sensor output controlled by eyeball movements

The difference between the infrared absorption of the iris and infrared reflectivity of the eyeball controls the operation of a device consisting of an infrared source and amplifier, a cadmium selenide infrared sensor, and an infrared filter.

Source record↗

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry↗

Satellite remote sensing of the ocean

A concise description of the principles and applications of several selected instruments that have been utilized most frequently in remote sensing of the ocean from satellites is presented. Emphasis is placed on the current progress in oceanographic applications and the outlook of the instruments in future oceanographic satellite missions is discussed. The instruments under discussion are placed into three groups: active microwave sensors, passive ocean color and infrared sensors, and passive microwave sensors.

Fu, Lee-Lueng↗

Measured Boundary Layer Transition and Rotor Hover Performance at Model Scale

An experiment involving a Mach-scaled, 11:08 f t: diameter rotor was performed in hover during the summer of 2016 at NASA Langley Research Center. The experiment investigated the hover performance as a function of the laminar to turbulent transition state of the boundary layer, including both natural and fixed transition cases. The boundary layer transition locations were measured on both the upper and lower aerodynamic surfaces simultaneously. The measurements were enabled by recent advances in infrared sensor sensitivity and stability. The infrared thermography measurement technique was enhanced by a paintable blade surface heater, as well as a new high-sensitivity long wave infrared camera. The measured transition locations showed extensive amounts, x=c>0:90, of laminar flow on the lower surface at moderate to high thrust (CT=s > 0:068) for the full blade radius. The upper surface showed large amounts, x=c > 0:50, of laminar flow at the blade tip for low thrust (CT=s < 0:045). The objective of this paper is to provide an experimental data set for comparisons to newly developed and implemented rotor boundary layer transition models in CFD and rotor design tools. The data is expected to be used as part of the AIAA Rotorcraft SimulationWorking Group

Overmeyer, Austin D.↗

Design and Requirements Creep In A Build-To-Print Mission

Build-to-Print designs, or rebuilds of flight proven designs, are attractive to mission stakeholders, as they give the appearance of minimal engineering development cost, risk, and schedule. The reality is that seldom is a project an exact duplicate of a predecessor. Mission reclassification, improvements in hardware, and science objective changes can all serve as a source of requirements and design creep and have ramifications often not fully anticipated during initial proposals. The Thermal Infrared Sensor Instrument (TIRS) was a late addition to the LandSat-8 program to provide infrared imaging to measure evapotranspiration for water cycle management. To meet the launch requirements for LandSat-8, instrument design life requirements were relaxed, the sensor development expedited, and technology development was minimized. Consequently, TIRS was designed as a higher risk instrument, with less redundancy than an instrument critical to mission success. After the successful LandSat-8 launch in 2013 and instrument performance, a rebuild of the instrument for the next LandSat spacecraft was included in the baseline mission success criteria. This paper discusses the technical challenges encountered during the rebuild of the TIRS-2 (Thermal Infrared Sensor 2) instrument and the resultant impacts on the thermal system design.

TIRS-2 Thermal Design↗

High resolution infrared measurements

Sample ground based cloud radiance data from a high resolution infrared sensor are shown and the sensor characteristics are presented in detail. The purpose of the Infrared Analysis Measurement and Modeling Program (IRAMMP) is to establish a deterministic radiometric data base of cloud, sea, and littoral terrain clutter to be used to advance the design and development of Infrared Search and Track (IRST) systems as well as other infrared devices. The sensor is a dual band radiometric sensor and its description, together with that of the Data Acquisition System (DAS), are given. A schematic diagram of the sensor optics is shown.

Kessler, B.↗

Landsat 9 TIRS-2 Performance Results Based on Subsystem-Level Testing

Landsat 9 is the next in the series of Landsat satellites and has a complement of two pushbroom imagers: Operational Land Imager-2 (OLI-2) that samples the solar reflective spectrum with nine channels and Thermal Infrared Sensor-2 (TIRS-2) samples the thermal infrared spectrum with two channels. The first builds of these sensors, OLI and TIRS, were launched on Landsat 8 in 2013 and Landsat 9 is expected to launch in December 2020. TIRS-2 is designed and built to continue the Landsat data record and satisfy the needs of the remote sensing community. There are two sets of requirements considered for planning the component, subsystem and instrument level tests for TIRS-2: performance requirements and Special Calibration Test Requirements (SCTR). The performance requirements specify key spectral, spatial, radiometric, and operational parameters of TIRS-2 while the SCTRs specify parameters of how the instrument is tested. Several requirements can only be verified at the instrument level, but many performance metrics can be assessed earlier in prelaunch testing at the subsystem level. A test program called TIRS Imaging Performance and Cryoshell Evaluation (TIPCE) was developed to characterize TIRS-2 spectral, spatial, and scattered-light rejection performance at the telescope and detector subsystem level. There were three thermal vacuum campaigns in TIPCE that occurred from November 2017 to March 2018. This work shows results of TIPCE data analysis which provide confidence that key requirements will be met at instrument level with a few minor waivers. A full complement of performance testing will be done at the TIRS-2 instrument level for final verification in late 2018 through Spring 2019.

scatter↗

Highly automated optical characterization with FTIR spectrometry

The procedure for evaluating the characteristics of II-VI semiconducting infrared sensor materials with a Fourier Transform Infrared (FTIR) spectrometer system will be discussed. While the method of mapping optical characteristics with a spectrometer has been employed previously, this system is highly automated compared to other systems where the optical transmission data are obtained using a FTIR system with a small stationary aperture in the optical path and moving the specimen behind the aperture. The hardware and software, including an algorithm developed for extracting cut-on wavelengths of spectra, as well as several example results, are described to illustrate the advanced level of the system. Additionally, data from transverse slices and longitudinal wafers of the aforementioned semiconductors will be used to show the accuracy of the system in predicting trends in materials such as shapes of growth interfaces and compositional uniformity.

Perry, G. L. E.↗

Gaps in Thermal Design Guidelines in the Goddard Space Flight Center GOLD Rules

The GSFC (Goddard Space Flight Center) GOLD Rules (Goddard Open Learning Design; GSFC-STD-1000) provide a reasonably comprehensive list of guidelines for the design and testing of spacecraft and instruments based on the long heritage of successful GSFC missions. In general, all GSFC missions are required to comply with the GOLD Rules across a number of subsystems or to seek waivers to particular GOLD rules where compliance is not practical, either due to the risk posture of a mission or the cost and/or schedule associated with compliance. In thermal subsystems, GOLD Rules are applied to design margins throughout the project life cycle and include temperature margins, heater power margins, and two-phase transport margins. However, no explicit guidance is provided for two thermal design aspects: heater control authority (for stability requirements) and cryogenic design margins (which are often not reasonable to express in terms of temperatures). This can lead to ambiguity and inconsistency among projects when demonstrating GOLD Rules compliance. Two current GSFC projects, TIRS-2 (Thermal InfraRed Sensor 2) and WFIRST (Wide Field InfraRed Survey Telescope), are both missions with cryogenic aspects and active thermal control for stability. This paper seeks to outline the characterization of cryogenic margins during the design process for TIRS-2 and WFIRST as well as the project derived guidelines for heater control authority margin. This effort serves as potential first steps for updating the GOLD Rules to address these two areas in guiding thermal designs at GSFC.

Modeling↗

Layered Internal-Photoemission Sensor

High quantum efficiency achieved without multiple layer contacts. Proposed infrared sensor based on photoemission from multiple layers of metal silicide sandwiched between layers of silicon. Suitable for use in focal-plane arrays. Layered internal-photoemission sensor has positive/intrinsic/negative structure modified by inclusion of layers or islands of metal silicide. Holes photo-excited from silicide regions and swept to detection by reverse-bias electric field in intrinsic silicon. Easier to make because internal layers allowed to "float" electrically, contact being made with only two outer semiconductor layers.

Fathauer, Robert W.↗

Radiometric Calibration and Stability of the Landsat-8 Operational Land Imager (OLI)

Landsat-8 and its two Earth imaging sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) have been operating on-orbit for 2 1/2 years. The OLI radiometric calibration, which is monitored using on-board lamps, on-board solar diffusers, the moon and vicarious calibration techniques has been stable to within 1% over this period of time. The Coastal Aerosol band, band 1, shows the largest change at about 1% over the period; all other bands have shown no significant trend. OLI bands 1- 4 show small discontinuities in response (+0.1% to 0.2%) beginning about 7 months after launch and continuing for about 1 month associated with a power cycling of the instrument, though the origin of the recovery is unclear. To date these small changes have not been compensated for, but this will change with a reprocessing campaign that is currently scheduled for Fall 2015. The calibration parameter files (each typically covering a 3 month period) will be updated for these observed gain changes. A fitted response to an adjusted average of the lamps, solar and lunar results will represent the trend, sampled at the rate of one value per CPF.

radiometric stability↗

Radiometric Calibration and Stability of the Landsat-8 Operational Land Imager (OLI)

Landsat-8 and its two Earth imaging sensors, the Operational Land Imager (OLI) and Thermal Infrared Sensor (TIRS) have been operating on-orbit for 2 1/2 years. The OLI radiometric calibration, which is monitored using on-board lamps, on-board solar diffusers, the moon and vicarious calibration techniques has been stable to within 1% over this period of time. The Coastal Aerosol band, band 1, shows the largest change at about 1% over the period; all other bands have shown no significant trend. OLI bands 1- 4 show small discontinuities in response (+0.1% to 0.2%) beginning about 7 months after launch and continuing for about 1 month associated with a power cycling of the instrument, though the origin of the recovery is unclear. To date these small changes have not been compensated for, but this will change with a reprocessing campaign that is currently scheduled for Fall 2015. The calibration parameter files (each typically covering a 3 month period) will be updated for these observed gain changes. A fitted response to an adjusted average of the lamps, solar and lunar results will represent the trend, sampled at the rate of one value per CPF.

radiometry↗

LANDSAT 9: Mission Status and Prelaunch Instrument Performance Characterization and Calibration

Landsat 9 is currently under development as a joint effort between NASA and the United States Geological Survey (USGS). Landsat 9 is largely a rebuild of Landsat 8 and has the same two sensors, an Operational Land Imager (OLI) and a Thermal InfraRed Sensor(TIRS). The OLI-2 on Landsat 9, being built by Ball Aerospace, has completed its pre-launch characterization and calibration and is scheduled to be delivered in the summer of 2019. The TIRS-2, with improved stray light performance and increased redundancy for improved reliability, is being built by Goddard Space Flight Center. TIRS-2is undergoing testing through Spring 2019 and is also scheduled for summer2019 delivery. Several improvements to the characterization of both instruments have been incorporated into the testing plan, including improved spectral and radiometric characterization. The instruments will then be integrated onto the spacecraft being built by Northrop Grumman Innovation Systems (NGIS). The mission is targeted to launch as early as December 2020 on an Atlas V.

Landsat↗

Landsat-8 TIRS Thermal Radiometric Calibration Status

The Landsat-8 Thermal Infrared Sensor (TIRS) has been acquiring two-band thermal infrared images of the Earth’s surface since 2013. The calibration of the two-band system has been monitored using the on-board calibrator and validated with vicarious calibration performed by NASA/JPL and RIT since launch. Soon after launch, it was discovered that the instrument had a significant stray light effect that was affecting the radiometric calibration. The stray light was corrected in the processing system in 2017. Since then, it has become apparent that there was an additional radiometric error, based on the vicarious calibration results. With a failure within the primary electronic system and subsequent switch to the redundant electronic system, the TIRS instrument effectively has two separate calibration regimes. The vicarious calibration found a statistically significant calibration error, primarily a constant over time, in Band 11 on the primary electronics (Feb 11,2013 through March 5,2015) of about -0.6K at 300K. The calibration error in Band 10 was smaller though still statistically significant at about 0.2K at 300K. On the redundant side(March 5,2015 to present), the calibration error is more signal dependent than time dependent. Both bands are affected, with Band 10 having an error between 1K and -0.4K (between 273-320K) and Band 11 having an error between 0.8K and -1.44K (between 273-320K).This calibration error will be corrected within the USGS Landsat Product Generation System with the release of Landsat Collection-2 products. The Collection-2 release also includes a correction to the relative radiometric calibration of TIRS data. Striping as a result of poor detector-to-detector normalization has been increasing in the imagery since launch. The TIRS relative radiometric calibration will be updated based on internal calibrator data to remove the stripes on a quarterly basis. The visible stripes are generally at 0.1-0.2% level, though there are some detectors in each band that have changed by 1% or more. The Collection-2 release will result in much more uniform TIRS images.

Julia A Barsi↗