Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Absolute and angular efficiencies of a microchannel-plate position-sensitive detector

This paper presents a characterization of a commercially available position-sensitive detector of energetic ions and neutrals. The detector consists of two microchannel plates followed by a resistive position-encoding anode. The work includes measurement of absolute efficiencies of H(+), He(+), and O(+) ions in the energy range between 250 and 5000 eV, measurement of relative detection efficiencies as a function of particle impact angle, and a simple method for accurate measurement of the time at which a particle strikes the detector.

Gao, R. S.↗

A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

NASA Center HQS↗

Micro-machined planar field asymmetric ion mobility spectrometer as a gas chromatographic detector

A planar high field asymmetric waveform ion mobility spectrometer (PFAIMS) with a micro-machined drift tube was characterized as a detector for capillary gas chromatography. The performance of the PFAIMS was compared directly to that of a flame ionization detector (FID) for the separation of a ketone mixture from butanone to decanone. Effluent from the column was continuously sampled by the detector and mobility scans could be obtained throughout the chromatographic analysis providing chemical inforrmation in mobility scans orthogonal to retention time. Limits of detection were approximately I ng for measurement of positive ions and were comparable or slightly better than those for the FID. Direct comparison of calibration curves for the FAIMS and the FID was possible over four orders of magnitude with a semi-log plot. The concentration dependence of the PFAIMS mobility scans showed the dependence between ion intensity and ion clustering, evident in other mobility spectrometers and atmospheric pressure ionization technologies. Ions were identified using mass spectrometry as the protonated monomer and the proton bound dimer of the ketones. Residence time for column effluent in the PFAIMS was calculated as approximately 1 ms and a 36% increase in extra-column broadening versus the FID occurred with the PFAIMS.

NASA Discipline Life Sciences Technologies↗

Ion tracking in an electrostatic potential distribution

An ion tracking system utilizing a single detector was designed to resolve two dimensional potential distributions in a vacuum. The ion detector consisted of a continuous dynode electron multiplier tube mounted behind a series of aperture plates. The detector was located on a track below a wedge shaped structure used to produce the desired potential distribution. A 150 volt electron beam aimed at selected regions, ionized the residual gas in the chamber. The ions were ejected from their source points by electrostatic forces causing them to drift downward toward the detector. Measurements of particle energy, detector position, and entry angle of the incoming particle flux were used to initialize a computer trajectory-tracing program. The program assumes a known theoretically calculated potential distribution near the wedge for computation of particle trajectories, providing a basis for evaluating the data. Special attention was given to characterization of the ion detector.

Ross, D. P.↗

Energy distribution functions of kilovolt ions in a modified Penning discharge

The distribution function of ion energy parallel to the magnetic field of a Penning discharge was measured with a retarding potential energy analyzer. Simultaneous measurements of the ion energy distribution function perpendicular to the magnetic field were made with a charge-exchange neutral detector. The ion energy distribution functions are approximately Maxwellian, and their kinetic temperatures are equal within experimental error. This suggests that turbulent processes previously observed Maxwellianize the velocity distribution along a radius in velocity space, and result in an isotropic energy distribution. The kinetic temperatures are on the order of kilovolts, and the tails of the ion energy distribution functions are Maxwellian up to a factor of 7 e-folds in energy. When the distributions depart from Maxwellian, they are enhanced above the Maxwellian tail. Above densities of about 10 to the 10th power particles/cc, this enhancement appears to be the result of a second, higher temperature Maxwellian distribution. At these high particle energies, only the ions perpendicular to the magnetic field lines were investigated.

Roth, J. R.↗

Energy distribution functions of kilovolt ions parallel and perpendicular to the magnetic field of a modified Penning discharge

The distribution function of ion energy parallel to the magnetic field of a modified Penning discharge has been measured with a retarding potential energy analyzer. These ions escaped through one of the throats of the magnetic mirror geometry. Simultaneous measurements of the ion energy distribution function perpendicular to the magnetic field have been made with a charge exchange neutral detector. The ion energy distribution functions are approximately Maxwellian, and the parallel and perpendicular kinetic temperatures are equal within experimental error. These results suggest that turbulent processes previously observed in this discharge Maxwellianize the velocity distribution along a radius in velocity space and cause an isotropic energy distribution. When the distributions depart from Maxwellian, they are enhanced above the Maxwellian tail.

Roth, R. J.↗

Energy distribution functions of kilovolt ions in a modified Penning discharge.

The distribution function of ion energy parallel to the magnetic field of a modified Penning discharge has been measured with a retarding potential energy analyzer. These ions escaped through one of the throats of the magnetic mirror geometry. Simultaneous measurements of the ion energy distribution function perpendicular to the magnetic field have been made with a charge-exchange neutral detector. The ion energy distribution functions are approximately Maxwellian, and the parallel and perpendicular kinetic temperatures are equal within experimental error. These results suggest that turbulent processes previously observed in this discharge Maxwellianize the velocity distribution along a radius in velocity space, and result in an isotropic energy distribution.

Roth, J. R.↗

Energy distribution functions of kilovolt ions in a modified Penning discharge.

The distribution function of ion energy parallel to the magnetic field of a modified Penning discharge has been measured with a retarding potential energy analyzer. These ions escaped through one of the throats of the magnetic mirror geometry. Simultaneous measurements of the ion energy distribution function perpendicular to the magnetic field have been made with a charge-exchange neutral detector. The ion energy distribution functions are approximately Maxwellian, and the parallel and perpendicular kinetic temperatures are equal within experimental error. These results suggest that turbulent processes previously observed in this discharge Maxwellianize the velocity distribution along a radius in velocity space, and result in an isotropic energy distribution.

Roth, J. R.↗

Observations of low-energy plasma composition from the ISEE-1 and SCATHA satellites

This brief review is concerned with some of the initial measurements of low-energy ion properties conducted with the aid of ion composition detectors aboard the ISEE-1 and SCATHA satellites. ISEE-1 was launched in October 1977 into a highly elliptical orbit, while SCATHA was launched in January 1979 into a near geosynchronous orbit. Attention is given to the origin of low-energy plasma, the energization of ionospheric ions, the transport of ionospheric ions, and the loss of low-energy plasma from the magnetosphere. According to results obtained during the past several years, including the present ISEE-1 and SCATHA results, there are significant, and occasionally dominant, concentrations of He(+) and O(+) in various locations within the magnetosphere.

Horwitz, J. L.↗

Dosimetry of heavy ions by use of CCD detectors

The design and the atomic composition of Charge Coupled Devices (CCD's) make them unique for investigations of single energetic particle events. As detector system for ionizing particles they detect single particles with local resolution and near real time particle tracking. In combination with its properties as optical sensor, particle transversals of single particles are to be correlated to any objects attached to the light sensitive surface of the sensor by simple imaging of their shadow and subsequent image analysis of both, optical image and particle effects, observed in affected pixels. With biological objects it is possible for the first time to investigate effects of single heavy ions in tissue or extinguished organs of metabolizing (i.e. moving) systems with a local resolution better than 15 microns. Calibration data for particle detection in CCD's are presented for low energetic protons and heavy ions.

Schott, J. U.↗

Lunar mass spectrometer test program

The procedures used and the results are described, which were obtained in a test program to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The instrument consists of a cold cathode ion source, a small quadrupole mass analyzer, and an off-axis electron multiplier ion-counting detector. Instrument resolution, sensitivity, and S/N ratio were demonstrated over the mass range 0-150 amu and over a partial pressure range from ntorr to ptorr. The subject analyzer was also prepared for extended testing, in conjunction with two other candidate instruments, in a large molecular beam vacuum facility.

Torney, F. L.↗

Lunar mass spectrometer test program

The procedures are described along with results obtained in a test program conducted to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The subject instrument consists of a cold cathode ion source, a small quadrupole mass analyzer and an off axis electron multiplier ion counting detector. The major program emphasis was placed on demonstrating instrument resolution, sensitivity and S/N ratio over the mass range 0-150 amu and over a partial pressure range from 10 to the minus 9th power to 10 to the minus 13th power torr. Ultrahigh vacuum tests were conducted and the minimum detectable partial pressure for neon, argon, krypton and xenon was successfully determined for the spectrometer using isotopes of these gases. With the exception of neon, the minimum detectable partial pressure is approximately 4 x 10 to the minus 14th power torr for the above gases.

Torney, F. L.↗

Soft X-ray flare spectra

Large solar flares produce intense soft X-ray emission, indicating the existence of high temperature plasmas that coexist in time with the plasmas responsible for the normally observed brightenings in H-alpha. The time behavior of the X-ray flux, as revealed, for example, by ion chamber detectors on the series of Solrad monitoring satellites, appears to roughly mimic the intensity-time behavior of the H-alpha flare, insofar as start times, times of maximum flux, and approximate decay times are concerned. In recent years, soft X-ray spectra of both active regions and solar flares have been obtained by instruments flown on spacecraft such as the Orbiting Solar Observatory (OSO) series. The disbursing elements used were Bragg crystals, and in the 8 Angstrom region the resolution is typically approximately 1200. This paper discusses the observed characteristics of X-ray flare spectra and spectroscopic diagnostics for determining electron temperatures, electron densities, and departures from ionization equilibrium within the soft X-ray emitting plasma.

Doschek, G. A.↗

Lignin Sensor Based On Flash-Pyrolysis Mass Spectrometry

New lignin sensor takes only few minutes to measure lignin content of specimen of wood, pulp, paper, or similar material. Includes flash pyrolizer and ion-trap detector that acts as mass spectrometer. Apparatus measures amount of molecular fragments of lignin in pyrolysis products of samples. Helpful in controlling digestors in paper mills to maintain required lignin content, and also in bleaching plants, where good control of bleaching becomes possible if quick determination of lignin content made.

Kwack, Eug Y.↗

Fourth workshop on Experiments and Detectors for a Relativistic Heavy Ion Collider

We present a description of an experiment which can be used to search for effects of strong electromagnetic fields on the production of e(sup +) e(sup -) pairs in the elastic scattering of two heavy ions at the Relativistic Heavy Ion Collider (RHIC). A very brief discussion of other possible studies of electromagnetic phenomena at RHIC is also presented.

Fatyga, M.↗