At least 127 records · Page 7

Experimental studies of the two-step scheme with an intense radioactive 132 Sn beam for next-generation production of very neutron-rich nuclei

The study of nuclei in the yet-unexplored, very neutron-rich, mid- to heavy-mass region of the nuclear chart, comprising perhaps half of all nuclei predicted to exist, is leading to new and/or upgraded facilities, as well as to research into the underlying production processes. In the present study, the usefulness of the two-step scheme, an alternate method to produce very neutron-rich nuclei, by a combination of an isotope-separation online (ISOL) system as a first step, and in-beam fragmentation of re-accelerated radioactive isotopes (RIs) as a second step, was investigated with a 132 Sn beam. In this work, very neutron-rich RIs around the neutron-rich neutron number N = 82 region were produced from the 278-MeV/nucleon 132 Sn beam impinging on a 5.97-mm Be target, and their production cross sections were measured. Yields were then estimated for the two-step scheme with the 132 Sn beam relative to the ones by a one-step scheme, in-flight fission of a 238 U beam, for 1-MW proton and 238 U beams at respective RI-beam facilities. This comparison suggests that the two-step scheme with the 132 Sn beam provides yields >40-times higher than those with the one-step scheme for the very neutron-rich N = 82 region. Moreover, by using various RI beams over the nuclear chart from ISOL, certain kinds of very neutron-rich RIs around the supernova r-process path can be produced with greater yields than by the one-step approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Theory Manual for the Fuel Cycle Analysis Code REBUS

REBUS is a system of programs designed for the fuel cycle analysis of fast reactors and accelerator-driven systems. The first version of REBUS was developed in 1970 for calculating the equilibrium operating conditions of liquid metal fast breeder reactors. During the past five decades, various extensions and refinements have been made in the simulation of material motions in fuel cycle facilities and the solution of the neutronics and isotopic transmutation equations that govern the reactor behavior. The latest version complies with the standard code practices and interface dataset specifications of the committee on computer code coordination (CCCC). This report provides a detailed description of the physical processes and their mathematical models and solution methods of the current production version of REBUS. The models of the facilities and physical processes involved in fast reactor fuel cycle are first discussed. Then the mathematical formulation of these physical models is presented, followed by detailed discussions of solution methods of the resulting set of equations. Finally the output edit quantities are discussed along with their definitions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies↗

Observation of New Isotopes in the Fragmentation of Pt 198 at FRIB

Five previously unknown isotopes ( 182,183 Tm, 186,187 Yb, 190 Lu) were produced, separated, and identified for the first time at the Facility for Rare Isotope Beams (FRIB) using the Advanced Rare Isotope Separator (ARIS). The new isotopes were formed through the interaction of a 198 Pt beam with a carbon target at an energy of 186 MeV/u and with a primary beam power of 1.5 kW. Event-by-event particle identification of A, Z, and q for the reaction products was performed by combining measurements of the energy loss, time of flight, magnetic rigidity Bρ, and total kinetic energy. The ARIS separator has a novel two-stage design with high resolving power to strongly suppress contaminant beams. Finally, this successful new isotope search was performed less than one year after FRIB operations began and demonstrates the discovery potential of the facility which will ultimately provide 400 kW of primary beam power.

07 ISOTOPE AND RADIATION SOURCES↗

Business Plan for a Domestic Supply of Superconducting Radiofrequency Cavities

Superconducting radiofrequency (SRF) cavities are critical components of modern particle accelerators. The industrialization of SRF technology in the U.S. has a long history, with several companies becoming interested in the technology in the past 30 years. However, there is currently no U.S. manufacturer with the capability to produce fully assembled, ready-to-test SRF cavities. A majority of these companies have either left the field or shut their doors. As a result, government-sponsored SRF accelerator projects in the U.S. largely rely on European vendors for the cavity supply. This presents not only a supply chain risk for scientific use cases, but also severely limits the commercialization of accelerator-based technologies. SRF accelerators have a range of strategic applications, including environmental remediation, semiconductor lithography, medical isotope production, and irradiation/sterilization. The nurturing of a domestic SRF industry is critical to maintaining U.S. economic competitiveness.

43 PARTICLE ACCELERATORS↗

Neutron Source Facility of the National Science Center “Kharkiv Institute of Physics and Technology” at Kharkiv, Ukraine

Argonne National Laboratory developed, designed, and supported the construction of a state-of-the-art Neutron Source Facility (NSF) at the Kharkov Institute of Physics and Technology (KIPT) in Kharkov Ukraine, under the U.S. DOE NNSA Russian Research Reactor Fuel Return (RRRFR) program. Ukraine approved the return of all highly enriched uranium in the country to Russia prior to the 2012 Nuclear Security Summit in return for the RRRFR program to fund the development, the design, and the construction of the NSF. The facility is designed to produce medical isotopes, train nuclear professionals, support the Ukrainian nuclear industry, and provide experimental capabilities for performing reactor physics, materials, and basic science research. The NSF was successfully started and operated in August 2021. The NSF is the first facility of this type in the world, and it will be used to understand the physics of driven systems for energy production and the disposal of spent nuclear fuels. The NSF consists of a subcritical assembly using low enriched uranium (LEU) fuel driven with an electron accelerator. The NSF target design utilizes tungsten or natural uranium for producing neutrons through photonuclear reactions using 100-MeV electrons. The accelerator power is 100 KW, which produces 3x10 14 neutrons per second from the uranium target. The subcritical assembly is designed to obtain the highest possible neutron flux intensity with an effective neutron multiplication factor of less than 0.98. Passive safety, reliability, and environmental considerations were included in the NSF design. The NSF utilization study shows that this neutron source has the capability of producing different medical isotopes. Several horizontal neutron channels are incorporated for performing applied and basic research. The NSF is configured to accommodate future design upgrades and new missions. The facility design was approved by the Ukraine Academy of Sciences before starting the NSF construction. The construction, the equipment installation, and the operation of the different systems of the NSF were completed and approved by the Ukrainian regulators. In July 2020, the State Nuclear Regulatory Inspectorate of Ukraine (SNRIU) issued a license for the physical startup of the NSF. The construction of facility was completed in early 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis in Support of Disposition of Tank 48 Legacy Material

This report contains the characterization of six 200-mL Tank 48H samples: HTF-48-21-74, HTF-48-21-75, HTF-48-21-76, HTF-48-21-81, HTF-48-21-82, and HTF-48-21-83. The effort supports a Systems Engineering Evaluation (SEE) recommendation involving a Tank 48H decantation strategy that would remove liquid volume and grout the solids. The first three Tank 48H samples were surface samples taken after a quiescent period in the tank. The quiescent period allowed settling of the solids, these being mostly potassium tetraphenylborate. These three surface samples had no measurable solids, though a settling haze could be seen. The latter three samples were taken at 48, 25, and 10 inches from the bottom of Tank 48H immediately after tank mixing pumps had been run. Those samples contained measurable insoluble solids that were readily visible. All six samples were analyzed to provide chemical and radionuclide concentrations as defined as the "Limit" and "Target" in the Saltstone Production Facility (SPF) Waste Acceptance Criteria (WAC) and per the compliance strategy in the Tank Farm Waste Compliance Plan (WCP). Samples were analyzed by many methods to determine pH, density/specific gravity, radioactive isotopes, soluble and insoluble elements, total solids, total insoluble solids, organic and inorganic mercury, volatile and semi-volatile chemicals, and anions. Photographs of the settling of small samples were taken over time and are displayed in this report. The extent of settling was very significant, showing that surface sample liquids are similar to filtrates. However, Cs-137 measurements exceeded WAC limits in all surface samples (1.1E+07 vs. 1.3E+06). The solids were found to contain very high cesium activity, measured as high as 1.1E+10 dpm/gram. Sodium was in the range of 4.24 to 4.74 M for all samples, so the solids would tend to settle with time and would not be at risk of floating without air entrainment. No organic mercury was detected in this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis in Support of Disposition of Tank 48 Legacy Material

This report contains the characterization of six 200-mL Tank 48H samples: HTF-48-21-74, HTF-48-21-75, HTF-48-21-76, HTF-48-21-81, HTF-48-21-82, and HTF-48-21-83. The effort supports a Systems Engineering Evaluation (SEE) recommendation involving a Tank 48H decantation strategy that would remove liquid volume and grout the solids. The first three Tank 48H samples were surface samples taken after a quiescent period in the tank. The quiescent period allowed settling of the solids, these being mostly potassium tetraphenylborate. These three surface samples had no measurable solids, though a settling haze could be seen. The latter three samples were taken at 48, 25, and 10 inches from the bottom of Tank 48H immediately after tank mixing pumps had been run. Those samples contained measurable insoluble solids that were readily visible. All six samples were analyzed to provide chemical and radionuclide concentrations as defined as the "Limit" and "Target" in the Saltstone Production Facility (SPF) Waste Acceptance Criteria (WAC) and per the compliance strategy in the Tank Farm Waste Compliance Plan (WCP). Samples were analyzed by many methods to determine pH, density/specific gravity, radioactive isotopes, soluble and insoluble elements, total solids, total insoluble solids, organic and inorganic mercury, volatile and semi-volatile chemicals, and anions. Photographs of the settling of small samples were taken over time and are displayed in this report. The extent of settling was very significant, showing that surface sample liquids are similar to filtrates. However, Cs-137 measurements exceeded WAC limits in all surface samples (1.1E+07 vs. 1.3E+06). The solids were found to contain very high cesium activity, measured as high as 1.1E+10 dpm/gram. Sodium was in the range of 4.24 to 4.74 M for all samples, so the solids would tend to settle with time and would not be at risk of floating without air entrainment. No organic mercury was detected in this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessing high fidelity multi-component models to facilitate safeguards at Gas Centrifuge Enrichment Plants

We report that the International Atomic Energy Agency (IAEA) inspectors routinely carry out environmental sampling (ES) as a verification method. Collection of environmental swipe samples at various locations in Gas Centrifuge Enrichment Facilities (GCEPs) is an important process in detecting misuse of a declared facility and possibly the existence of undeclared nuclear material. These samples are measured for isotopic composition in uranium containing particles by Thermal Ionization Mass Spectrometry (TIMS) or Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Even though ES is highly effective in detecting the absolute value of enrichments and their deviations from the declared values, it cannot explain the cause of those changes. Several potential explanations can serve as possibilities for particles detected above or other than the declared enrichment. These include normal and non-malicious events such as the design of the enrichment cascades, unintentional failures of the machines, or overshoot during startup of a cascade. It can also be the result of deliberate misuse by the facility operators. The primary objective of this work is to understand how these factors affect the enrichments produced by a cascade and quantify anticipated multi-isotopic concentrations for each case. The following methodology is employed to determine signatures at a particular facility. 1) Utilize a new two-dimensional multi-component diffusion code to obtain centrifuge performance data and use that information to design and perform cascade analysis. Compare and contrast the results with previous 1-D radially averaged solutions from the Pancake code. 2) Design a GCEP cascade with the production goal of 19.75% 235 U for each set of machine data above. Investigate two cascade scenarios that include enrichment of natural uranium (NU) feed to 19.75% 235U in a single cascade compared to a two-step process of NU to 5% and then 5% to 19.75%. 3) Simulate the intentional vs. unintentional off-normal scenarios in the cascades to assess the differences in isotopic concentrations. A non-ideal squared-off cascade model developed at the University of Virginia is used to calculate flow rates and isotopic concentrations of the process gas. The analysis is performed using the Rome machine model operated at 600 m/s rotor speed. The upper and lower bounds of normal and abnormal enrichments in a typical facility are used in conjunction with ES results to understand the root causes of such observations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

An isotope harvesting beam blocker for the National Superconducting Cyclotron Laboratory

Harvesting isotopes from beam stops and other activated materials at accelerator facilities is a promising source of environmentally, scientifically and socially important radionuclides. At the Facility for Rare Isotope Beams (FRIB), a multitude of short- and long-lived radionuclides will be collected in a synergistic manner by dumping unused beams into a flowing-water beam stop. Ongoing exploratory research at the National Superconducting Cyclotron Laboratory (NSCL) with an analogous beam blocker aims towards obtaining the necessary radiochemical expertise for this endeavor. Herein we present a beam blocker and an isotope harvesting system which allows collection of a wide variety of aqueous and gaseous radionuclides. The water which flows through the beam blocker functions as an isotope production target and concurrently transports the newly formed radionuclides to collection sites. The system includes analytical instruments for online measurements of conductivity, dissolved oxygen, temperature, pressure and for detection of radiolytic products. To limit the levels of radiolytically produced hydrogen peroxide, a stainless-steel based degradation system was designed and implemented. Here, the suitability of the constructed system for the anticipated radionuclide harvesting project was demonstrated by offline tests and under irradiation with 140 MeV/u 48 Ca 20+ ions at the NSCL Coupled Cyclotron Facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Design of Micro Flux Monitors for Neutron Fluence Measurements

Measuring neutron flux is critical to understanding the characteristics of nuclear reactors and can provide information on the energy spectrum, total neutron fluence, and operational history of a facility. Such measurements are typically performed by irradiating high-purity materials in an operating reactor for a known length of time. By measuring and identifying activation products in the irradiated materials and referencing the energy-dependent cross section of each isotope, the neutron energy spectrum and total fluence can be determined. Historical techniques use a variety of small, individually pressed foils or wires for dosimeter devices, which can result in excessively high levels of radioactivity and complications in handling after irradiation. The present work describes a new neutron dosimetry concept, named the micro flux monitor, that uses semiconductor device fabrication processes to deposit thin films of flux monitoring materials in precise geometries onto a SiC wafer. This approach allows multiple dosimetry materials to be located on a single device, simplifying irradiation and subsequent analysis. The geometry, and therefore mass, of each material can be custom-tailored for a specific application—considering the expected neutron flux, duration of irradiation, and device retrieval time of a facility. Additionally, hundreds of identical dosimetry monitors can be produced simultaneously, reducing fabrication costs. Finally, the extremely thin metal dimensions of these devices could improve the fidelity of neutron fluence measurements by reducing neutron self-shielding and gamma self-attenuation effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LANSCE Capabilities

For more than 40 years the Los Alamos Neutron Science Center (LANSCE) has provided the scientific underpinnings in nuclear physics and material science needed to ensure the safety and surety of the nuclear stockpile into the future. In addition to national security research, the LANSCE User Facility has a vibrant research program in fundamental science, providing the scientific community with intense sources of neutrons and protons to perform experiments supporting civilian research and the production of medical and research isotopes.

43 PARTICLE ACCELERATORS↗

Spontaneous fission of the odd- Z isotope 255 Db

Experiments conducted at Lawrence Berkeley National Laboratory's 88-Inch Cyclotron Facility aimed to produce and study the decay of the previously unobserved isotope 255 Db. This isotope was produced in the 206 Pb( 51 V, 2⁢n) 255 Db reaction, separated from unreacted beam material and reaction by-products with the Berkeley Gas-filled Separator, and then implanted into a double-sided silicon-strip detector at the BGS focal plane. Decay properties of 255 Db were determined from the analysis of evaporation residue (EVR) fission and EVR-α–α correlations. The properties of this new isotope of dubnium differ dramatically from those of its neighboring Db isotopes. 255 Db was found to decay primarily by spontaneous fission (SF) with a small α-decay branch, where the average half-life of the observed decays was t 1/2 = 2.6$^{+0.4}_{– 0.3}$ ms. Theoretical calculations were performed using the Wentzel-Kramers-Brillouin approximation, with parameters calculated within a self-consistent microscopic approach, to see if these unique properties could be reproduced. A SF half-life estimate is obtained that closely matches the measured value, while simultaneously pointing out the sensitivities that need to be further constrained in future work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Improved high-gradient performance for medium-velocity superconducting half-wave resonators: Surface preparation and trapped flux mitigation

A development effort to improve the performance of superconducting radio-frequency half-wave resonators (SRF HWRs) is underway at the Facility for Rare Isotope Beams (FRIB), where 220 such resonators are in operation. Our goal was to achieve an intrinsic quality factor (𝑄 0 ) of ≥ 2 × 10 10 at an accelerating gradient (𝐸 acc ) of 12 MV/m. FRIB production resonators were prepared with buffered chemical polishing. First trials of electropolishing (EP) and post-EP low-temperature baking of FRIB HWRs allowed us to reach higher gradient (15 MV/m, limited by quench) with a higher quality factor at high gradient, but 𝑄 0 was still below our goal. Trapped magnetic flux during the Dewar test was found to be a source of 𝑄 0 reduction. Three strategies were used to reduce the trapped flux: (i) adding a local magnetic shield (LMGS) to supplement the “global” magnetic shield around the Dewar for reduction of the ambient magnetic field; (ii) performing a “uniform cooldown” (UC) to reduce the thermoelectric currents; and (iii) using a compensation coil to further reduce the ambient field with active field cancellation (AFC). The LMGS improved the 𝑄 0 , but not enough to reach our goal. With UC and AFC, we exceeded our goal, reaching 𝑄 0 = 2.8 ×10 10 at 𝐸 acc = 12 MV/m.

Cryogenics & vacuum technology↗

High Flux Isotope Reactor (HFIR)

Oak Ridge National Laboratory’s High Flux Isotope Reactor (HFIR) is the highest-flux reactor-based neutron source in the United States. HFIR’s intense neutron flux and state-of-the-art facilities result in world-class capabilities, including neutron scattering, radioisotope production, materials irradiation, and neutron activation analysis. HFIR’s multimission capabilities are attributed to its versatile high-power-density core design consisting of a series of concentric regions, including a flux trap target region, an inner fuel element, an outer fuel element, a control element region, and a beryllium reflector. The pressurized, light-water-cooled research reactor operates at 85 MW and is fueled by 9.4 kg 235U.

Chandler, David↗

MINOS Infrasound Analysis Synopsis

This report was written as a guide to working with infrasound data collected as part of the Multi-Informatics for Nuclear Operations Scenarios (MINOS)project, an NA-22 funded venture. The main purpose of overall MINOS project is the combination of multiple, disparate data modalities to characterize the operations at a nuclear facility, specifically instrumenting and studying the High-Flux Isotope Reactor (HFIR) and Radiochemical Engineering Development Center (REDC) locate at Oak Ridge National Laboratory in Oak Ridge, TN. HFIR is an 85 MW research reactor and is used primarily for production of medical radioisotopes, material irradiation experiments, neutron activation, and neutron scattering. Targets for the reactor are constructed, processed, and dissolved at REDC. REDC also hosts other glove-box and hot-cell type activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗