Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIQUID LEVEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Large Scale Production of Densified Hydrogen to the Triple Point and Below

Recent demonstration of advanced liquid hydrogen storage techniques using Integrated Refrigeration and Storage technology at NASA Kennedy Space Center led to the production of large quantities of densified liquid and slush hydrogen in a 125,000 L tank. Production of densified hydrogen was performed at three different liquid levels and LH2 temperatures were measured by twenty silicon diode temperature sensors. Overall densification performance of the system is explored, and solid mass fractions are calculated. Experimental data reveal hydrogen temperatures dropped well below the triple point during testing, and were continuing to trend downward prior to system shutdown. Sub-triple point temperatures were seen to evolve in a time dependent manner along the length of the horizontal, cylindrical vessel. The phenomenon, observed at two fill levels, is detailed herein. The implications of using IRAS for energy storage, propellant densification, and future cryofuel systems are discussed.

Hydrogen↗

Return to Service of a Liquid Hydrogen Storage Sphere

One, of two, 850,000 gallon liquid hydrogen storage spheres, at NASA's Kennedy Space Center, was decommissioned in 2010. This tank had an abnormally high heat leak that was investigated and determined to be the result of a large void in the perlite insulation. The insulation void was subsequently filled, and the tank was refurbished for its planned use in the Space Launch Systems (SLS) program. Return to service of this tank began in December of 2017 with a partial liquid hydrogen fill. Since that time, routine measurement of the liquid level have been recorded in order to establish a new boiloff rate and associated heat leak. This data shows the perlite top off activities have resulted in a much reduced, and within design specification, heat leak.

air leak↗

Return to Service of a Liquid Hydrogen Storage Sphere

One, of two, 850,000 gallon liquid hydrogen storage spheres, at NASA's Kennedy Space Center, was decommissioned in 2010. This tank had an abnormally high heat leak that was investigated and determined to be the result of a large void in the perlite insulation. The insulation void was subsequently filled, and the tank was refurbished for its planned use in the Space Launch Systems (SLS) program. Return to service of this tank began in December of 2017 with a partial liquid hydrogen fill. Since that time, routine measurement of the liquid level have been recorded in order to establish a new boiloff rate and associated heat leak. This data shows the perlite top off activities have resulted in a much reduced, and within design specification, heat leak.

Krenn, A. G.↗

Upgrades to the International Space Station Urine Processor Assembly

The ISS Urine Processor Assembly (UPA) began operations in November 2008. Though the UPA has successfully generated distillate from crew urine, several modifications and upgrades have been implemented to improve overall system performance throughout the years. Current and future upgrades to the UPA will continue to focus on improved system performance and reliability, focusing primarily on the Distillation Assembly and upgrades to the UPA vacuum pump. Work towards a flight demonstration experiment of a vacuum pump utilizing scroll pump technologies has also continued forward. The following paper discusses progress on these various concepts, including the implementation of a more reliable drive belt, improved methods for managing condensate in the stationary bowl of the Distillation Assembly, installation of improved centrifuge bearings, implementation of a liquid level sensor, and upgrades to the UPA vacuum pump.

Williamson, Jill P.↗

Multi-Node Modeling of Cryogenic Tank Pressurization System using Generalized Fluid System Simulation Program

This paper presents a multi-node model of autogenous pressurization of cryogenic propellant in a flight tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code developed at NASA/Marshall Space Flight Center. Tests were conducted to measure the pressure and temperatures at the various axial locations of the stratified ullage at 75% and 45% fill level. Liquid nitrogen was pressurized by gaseous nitrogen from a supply tank while the drain valve from the tank remained closed during the pressurization process. The ullage was discretized into 25 uniformly distributed nodes: 5 in the radial direction and 5 in the axial direction assuming the flow to be axisymmetric. Heat and mass transfer between the liquid and vapor has been modeled at the liquid vapor interface. Heat transfer between wall and vapor at the ullage has been accounted for by assuming heat transfer occurs by natural convection. The model also accounts for heat leak to the tank through the insulation and metal wall by heat conduction. The predicted pressures and temperatures are compared with the measured data.

Bandyopadhyay, Alak↗

Evaluation of a High-Resolution Numerical Weather Prediction Model’s Simulated Clouds Using Observations from CloudSat, GOES-13 and in Situ Aircraft

This study aimed to assess tropical cloud properties predicted by Environment and Climate Change Canada’s Global Environmental Multiscale (GEM)modelwhen run with the Milbrandt–Yau double-moment cloud microphysical scheme and one-way nesting that culminated at a (∼300 km)2 inner domain with 0.25 km horizontal grid spacing. The assessment utilized satellite and in situ data collected during the High Ice Water Content (HIWC) and High Altitude Ice Crystals (HAIC) projects for a mesoscale convective system on 16May 2015 over French Guiana.Data fromCloud- Sat’s cloud-profiling radar and GOES-13’s imager were compared to data either simulated directly by GEM or produced by operating on GEM’s cloud data with both the CFMIP (Cloud Feedback Model Intercomparison Project) Observation Simulator Package (COSP) instrument simulator and a three-dimensional Monte Carlo solar radiative transfer model. In situ observations were made from research aircraft – Canada’s National Research Council Convair-580 and the French SAFIRE Falcon-20 – whose flight paths were aligned with CloudSat’s ground-track. Spatial and temporal shifts of clouds simulated by GEM compared well to GOES-13 imagery. There are, however, differences between simulated and observed amounts of high and low cloud. While GEM did well at predicting ranges of ice-water content (IWC) near 11 km altitude (Falcon-20), it produces too much graupel and snow near 7 km (Convair-580). This produced large differences between CloudSat’s and COSP-generated radar reflectivities and two-way attenuations. On the other hand, CloudSat’s inferred values of IWC agree well with in situ samples at both altitudes. Generally, GEM’s visible reflectances exceeded GOES-13’s on account of having produced too much low-level liquid cloud. It is expected that GEM’s disproportioning of cloud hydrometeors will improve once it includes a better representation of secondary ice production.

Qu, Zhipeng↗

Upgrades to the International Space Station Urine Processor Assembly

Since November 2008, the ISS Urine Processor Assembly (UPA) has successfully generated distillate from crew urine. Several rounds of modifications and upgrades have also been implemented to improve overall system performance throughout the years. The Distillation Assembly (DA) is the latest upgraded unit available, installed in September 2020. This unit has shown immediate performance improvements and redesign success. Most significant upgrades have been a redesigned drive train to eliminate belt slips, improved sealing to reduce leak paths and improve wear, and a redesigned liquid level sensor. The Purge Pump and Separator Assembly (PPSA) technology demonstration is the next available upgraded unit and has finished ground assembly and testing and is targeted for ISS delivery within the coming year. Most recent ground studies have identified areas to focus future UPA upgrade considerations with exploration missions in mind, specifically for better fault detection and isolations approaches as well as potential hardware redesigns to facilitate successful dormancy operations.

Urine Processor Assembly↗

Electronic circuit provides automatic level control for liquid nitrogen traps

Electronic circuit, based on the principle of increased thermistor resistance corresponding to decreases in temperature provides an automatic level control for liquid nitrogen cold traps. The electronically controlled apparatus is practically service-free, requiring only occasional reliability checks.

Turvy, R. R.↗

Effect of Liquid Penetrant Sensitivity on Probability of Detection

The objective of the task is to investigate the effect of liquid penetrant sensitivity level on probability of detection (POD) of cracks in various metals. NASA-STD-5009 currently requires the use of only sensitivity level 4 liquid penetrants for NASA Standard Level inspections. This requirement is based on the fact that the data used to establish the reliably detectable flaw sizes penetrant inspection was from studies performed in the 1970s using penetrant deemed to be equivalent only to modern day sensitivity level 4 penetrants. However, many NDE contractors supporting NASA Centers routinely use sensitivity level 3 penetrants. Because of the new NASA-STD-5009 requirement, these contractors will have to either shift to sensitivity level 4 penetrants or perform formal POD demonstration tests to qualify their existing process. We propose a study to compare the POD generated for two penetrant manufactures, Sherwin and Magnaflux, and for the two most common penetrant inspection methods, water washable and post emulsifiable, hydrophilic. NDE vendors local to GSFC will be employed. A total of six inspectors will inspect a set of crack panels with a broad range of fatigue crack sizes. Each inspector will perform eight inspections of the panel set using the combination of methods and sensitivity levels described above. At least one inspector will also perform multiple inspections using a fixed technique to investigate repeatability. The hit/miss data sets will be evaluated using both the NASA generated DOEPOD software and the MIL-STD-1823 software.

Parker, Bradford H.↗

Effect of Liquid Penetrant Sensitivity on Probability of Detection

The objective of the task is to investigate the effect of liquid penetrant sensitivity level on probability of crack detection (POD). NASA-STD-5009 currently requires the use of only sensitivity level 4 liquid penetrants. This requirement is based on the fact that the data generated in the NTIAC Nondestructive Evaluation (NDE) Capabilities Data Book was produced using only sensitivity level 4 penetrants. Many NDE contractors supporting NASA Centers routinely use sensitivity level 3 penetrants. Because of the new NASA-STD-5009 requirement, these contractors will have to either shift to sensitivity level 4 penetrants or perform formal POD demonstration tests to qualify their existing process.

Parker, Bradford H.↗

Using Si Diodes To Detect H2 Liquid/Vapor Interfaces

Commercially available silicon-diode temperature sensors used to detect interfaces between hydrogen liquid and hydrogen vapor at steady-state saturation conditions. Sensors mounted at short intervals along rod to form rake-like array. Array inserted in tank with rod oriented vertically, where it senses level of liquid hydrogen to resolution equal to interval between sensors. Basic idea to measure voltage across sensor while supplying small electric current that heats sensor. Because vapor cools sensor less effectively than liquid does, sensor's steady-state temperature greater when sensor surrounded by vapor than when immersed in liquid. Voltage output decreases as temperature increases for silicon diodes. Thus, temperature (voltage) reading used to determine whether liquid level above or below sensor.

Dempsey, Paula Jean↗

Fiber-Optic Continuous Liquid Sensor for Cryogenic Propellant Gauging

An innovative fiber-optic sensor has been developed for low-thrust-level settled mass gauging with measurement uncertainty <0.5 percent over cryogenic propellant tank fill levels from 2 to 98 percent. The proposed sensor uses a single optical fiber to measure liquid level and liquid distribution of cryogenic propellants. Every point of the sensing fiber is a point sensor that not only distinguishes liquid and vapor, but also measures temperature. This sensor is able to determine the physical location of each point sensor with 1-mm spatial resolution. Acting as a continuous array of numerous liquid/vapor point sensors, the truly distributed optical sensing fiber can be installed in a propellant tank in the same manner as silicon diode point sensor stripes using only a single feedthrough to connect to an optical signal interrogation unit outside the tank. Either water or liquid nitrogen levels can be measured within 1-mm spatial resolution up to a distance of 70 meters from the optical interrogation unit. This liquid-level sensing technique was also compared to the pressure gauge measurement technique in water and liquid nitrogen contained in a vertical copper pipe with a reasonable degree of accuracy. It has been demonstrated that the sensor can measure liquid levels in multiple containers containing water or liquid nitrogen with one signal interrogation unit. The liquid levels measured by the multiple fiber sensors were consistent with those virtually measured by a ruler. The sensing performance of various optical fibers has been measured, and has demonstrated that they can survive after immersion at cryogenic temperatures. The fiber strength in liquid nitrogen has also been measured. Multiple water level tests were also conducted under various actual and theoretical vibration conditions, and demonstrated that the signal-to-noise ratio under these vibration conditions, insofar as it affects measurement accuracy, is manageable and robust enough for a wide variety of spacecraft applications. A simple solution has been developed to absorb optical energy at the termination of the optical sensor, thereby avoiding any feedback to the optical interrogation unit

Xu. Wei↗

Liquid propellant reorientation in a low-gravity environment

An existing empirical analysis relating to the reorientation of liquids in cylindrical tanks due to propulsive settling in a low gravity environment was extended to include the effects of geyser formation in the Weber number range from 4 to 10. Estimates of the minimum velocity increment required to be imposed on the propellant tank to achieve liquid reorientation were made. The resulting Bond numbers, based on tank radius, were found to be in the range from 3 to 5, depending upon the initial liquid fill level, with higher Bond number required for high initial fill levels. The resulting Weber numbers, based on tank radius and the velocity of the liquid leading edge, were calculated to be in the range from 6.5 to 8.5 for cylindrical tanks having a fineness ratio of 2.0, with Weber numbers of somewhat greater values for longer cylindrical tanks. It, therefore, appeared to be advantageous to allow small geysers to form and then dissipate into the surface of the collected liquid in order to achieve the minimum velocity increment. The Bond numbers which defined the separation between regions in which geyser formation did and did not occur due to propulsive settling in a spherical tank configuration ranged from 2 to 9 depending upon the liquid fill level.

Sumner, I. E.↗

Self-pressurization of a spherical liquid hydrogen storage tank in a microgravity environment

Thermal stratification and self-pressurization of partially filled liquid hydrogen (LH2) storage tanks under microgravity condition is studied theoretically. A spherical tank is subjected to a uniform and constant wall heat flux. It is assumed that a vapor bubble is located in the tank center such that the liquid-vapor interface and tank wall form two concentric spheres. This vapor bubble represents an idealized configuration of a wetting fluid in microgravity conditions. Dimensionless mass and energy conservation equations for both vapor and liquid regions are numerically solved. Coordinate transformation is used to capture the interface location which changes due to liquid thermal expansion, vapor compression, and mass transfer at liquid-vapor interface. The effects of tank size, liquid fill level, and wall heat flux on the pressure rise and thermal stratification are studied. Liquid thermal expansion tends to cause vapor condensation and wall heat flux tends to cause liquid evaporation at the interface. The combined effects determine the direction of mass transfer at the interface. Liquid superheat increases with increasing wall heat flux and liquid fill level and approaches an asymptotic value.

Lin, C. S.↗

Self-pressurization of a spherical liquid hydrogen storage tank in a microgravity environment

Thermal stratification and self-pressurization of partially filled liquid hydrogen (LH2) storage tanks under microgravity condition is studied theoretically. A spherical tank is subjected to a uniform and constant wall heat flux. It is assumed that a vapor bubble is located in the tank center such that the liquid-vapor interface and tank wall form two concentric spheres. This vapor bubble represents an idealized configuration of a wetting fluid in microgravity conditions. Dimensionless mass and energy conservation equations for both vapor and liquid regions are numerically solved. Coordinate transformation is used to capture the interface location which changes due to liquid thermal expansion, vapor compression, and mass transfer at liquid-vapor interface. The effects of tank size, liquid fill level, and wall heat flux on the pressure rise and thermal stratification are studied. Liquid thermal expansion tends to cause vapor condensation and wall heat flux tends to cause liquid evaporation at the interface. The combined effects determine the direction of mass transfer at the interface. Liquid superheat increases with increasing wall heat flux and liquid fill level and approaches an asymptotic value.

Lin, C. S.↗

Two-Phase Accumulator

Two-phase accumulator maintains pressure and temperature in thermal-bus system within predetermined range during variations in heat load on system. Stores liquid and vapor ammonia. Exchanges liquid ammonia with condenser to adjust level of liquid in condenser. Prototype has capacity of 13 gallons (49 liters). Simple and highly reliable. Responds quickly, restoring pressure and temperature to proper values within minutes. Low in cost and requires little further development. Used to dispose of waste heat, such as that from electronic equipment or power-plant.

Kalb, Charles E.↗

Propulsion Risk Reduction Activities for Non-Toxic Cryogenic Propulsion

The Propulsion and Cryogenics Advanced Development (PCAD) Project s primary objective is to develop propulsion system technologies for non-toxic or "green" propellants. The PCAD project focuses on the development of non-toxic propulsion technologies needed to provide necessary data and relevant experience to support informed decisions on implementation of non-toxic propellants for space missions. Implementation of non-toxic propellants in high performance propulsion systems offers NASA an opportunity to consider other options than current hypergolic propellants. The PCAD Project is emphasizing technology efforts in reaction control system (RCS) thruster designs, ascent main engines (AME), and descent main engines (DME). PCAD has a series of tasks and contracts to conduct risk reduction and/or retirement activities to demonstrate that non-toxic cryogenic propellants can be a feasible option for space missions. Work has focused on 1) reducing the risk of liquid oxygen/liquid methane ignition, demonstrating the key enabling technologies, and validating performance levels for reaction control engines for use on descent and ascent stages; 2) demonstrating the key enabling technologies and validating performance levels for liquid oxygen/liquid methane ascent engines; and 3) demonstrating the key enabling technologies and validating performance levels for deep throttling liquid oxygen/liquid hydrogen descent engines. The progress of these risk reduction and/or retirement activities will be presented.

Smith, Timothy D.↗