Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238 U and 239 Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two-fold approach was used to address the high-rate challenge in used nuclear fuel assay based on photofission technique. First, a standard HPGe preamplifier was modified to improve its capabilities in high-rate pulsed photofission environment. Second, advanced pulse processing algorithms were shown to greatly improve throughput rate without large sacrifice in energy resolution at ultra-high input count rate. Two customized gamma spectroscopy systems were also developed in real-time on FPGAs. They were shown to have promising performance matching available commercial units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Dose Neutron Detector Development Using 10 B Coated Cells

During FY16 the boron-lined parallel-plate technology was optimized to fully benefit from its fast timing characteristics in order to enhance its high count rate capability. To facilitate high count rate capability, a novel fast amplifier with timing and operating properties matched to the detector characteristics was developed and implemented in the 8” boron plate detector that was purchased from PDT. Each of the 6 sealed-cells was connected to a fast amplifier with corresponding List mode readout from each amplifier. The FY16 work focused on improvements in the boron-10 coating materials and procedures at PDT to significantly improve the neutron detection efficiency. An improvement in the efficiency of a factor of 1.5 was achieved without increasing the metal backing area for the boron coating. This improvement has allowed us to operate the detector in gamma-ray backgrounds that are four orders of magnitude higher than was previously possible while maintaining a relatively high counting efficiency for neutrons. This improvement in the gamma-ray rejection is a key factor in the development of the high dose neutron detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Stilbene Neutron Collar

A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation of list mode neutron correlation data on various fuel assemblies including some with neutron absorbers (burnable Gd poisons). Calibration curves (doubles vs 235 U linear mass density) are presented for both thermal and fast (with Cd lining) modes of operation. It is shown that the stilbene collar meets or exceeds the current capabilities of He-3 based neutron collars. A self-consistent assay methodology, uniquely suited to the stilbene collar, using triples is described which complements traditional assay based on doubles calibration curves.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Duplicating MC-15 Output with Python and MCNP

Two Python scripts have been written that process the output files of MCNP6 into a format that mimics the list-mode output of Los Alamos National Laboratory’s MC-15 and NPOD neutron detection systems. This report details the methods implemented in these scripts and instructions on their use.

97 MATHEMATICS AND COMPUTING↗

Fiscal Year (FY) 2017 Activities for the Spent Fuel Nondestructive Assay Project

The main focus of research in the NA-241 spent fuel nondestructive assay (NDA) project in FY17 has been completing the fabrication and testing of two prototype instruments for upcoming spent fuel measurements at the Clab interim storage facility in Sweden. One is a passive instrument: Differential Die-away Self Interrogation-Passive Neutron Albedo Reactivity (DDSI), and one is an active instrument: Differential Die-Away-Californium Interrogation with Prompt Neutron (DDA). DDSI was fabricated and tested with fresh fuel at Los Alamos National Laboratory in FY15 and FY16, then shipped to Sweden at the beginning of FY17. Research was performed in FY17 to simplify results from the data acquisition system, which is complex because signals from 56 different 3He detectors must be processed using list mode data. The DDA instrument was fabricated at the end of FY16. New high count rate electronics better suited for a spent fuel environment (i.e., KM-200 preamplifiers) were built specifically for this instrument in FY17, and new Tygon tubing to house electrical cables was purchased and installed. Fresh fuel tests using the DDA instrument with numerous configurations of fuel rods containing depleted uranium (DU), low enriched uranium (LEU), and LEU with burnable poisons (Gd) were successfully performed and compared to simulations.1 Additionally, members of the spent fuel NDA project team travelled to Sweden for a “spent fuel characterization and decay heat” workshop involving simulations of spent fuel and analysis of uncertainties in decay heat calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dual-Particle Imaging System with Neutron Spectroscopy for Safeguard Applications

A dual-particle imager (DPI) has been designed that is capable of detecting gamma-ray and neutron signatures from shielded SNM. The system combines liquid organic and NaI(Tl) scintillators to form a combined Compton and neutron scatter camera. Effective image reconstruction of detected particles is a crucial component for maximizing the performance of the system; however, a key deficiency exists in the widely used iterative list-mode maximum-likelihood estimation-maximization (MLEM) image reconstruction technique. For MLEM a stopping condition is required to achieve a good quality solution but these conditions fail to achieve maximum image quality. Stochastic origin ensembles (SOE) imaging is a good candidate to address this problem as it uses Markov chain Monte Carlo to reach a stochastic steady-state solution. The application of SOE to the DPI is presented in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quarterly Report 24.1.3.1

We are measuring freshly separated uranium samples using modern list mode (event-by-event) electronics with high resolution HPGe detectors to study the in-growth behaviors of uranium daughters’ gamma-rays. These data will show how we can use gamma-ray spectroscopy to determine the separation date for processed uranium. With this knowledge, one can obtain proper uranium isotope ratios using standard safeguards accountability software such as U-235 or MGAU.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

IER-407 CED-3b Rev-1: Experiment Execution Report for the Inherently Safe Subcritical Assembly (ISSA) Subcritical Measurements

This set of benchmark subcritical multiplicity experiments was conducted at the ISSA experiment center of Lawrence Livermore National Laboratory. The purpose of these subcritical experiments, as described in the ISSA final design report, was to measure fission neutrons by collecting time-tagged data corresponding to a maximum multiplication of approximately 20. The fission source for this experiment was Materials Test Reactor (MTR)-type highly enriched uranium fuel assembly, which is composed of nineteen fuel plates. One, two, four, six and nine ISSA fuel assemblies were closely packed and loaded inside a support fixture assembly and immersed in water. Four 3 He proportional counters were placed around the fuel assemblies, and list-mode experimental data was taken. Additionally, efficiency calibration measurements with calibrated neutron sources were conducted. The LLNL developed codes BIGFIT and OSANTI RESTART will be used to evaluate the measured data and calculate the experimental multiplication.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

CRADA: Data Acquisition and Tomographic Software Development

Dr. Raymond R. Raylman, Professor and Vice Chair for Research, Radiology Department at WVU was the Principal Investigator for the project. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and the chief contact with WVU. The responsibility of Jefferson Lab was to facilitate optimization of data acquisition software, conversion of JLab Fortran iterative positron emission mammography computer code to C++ and to act as a computer code repository. During the two year project interactions and exchange of information was directed by Dr. Raylman and Dr. Wesienberger. WVU provided the expertise that allowed JLab to continue development of the current JLab data acquisition software referred to as JDAQ. JDAQ is a highly flexible Java language based data acquisition tool that helps to minimize software induced dead-time while maintaining the highest possible data rates from a JLab built FPGA based analog-to-digital convertor (ADC). JDAQ interfaces directly with the FPGA based multi-channel ADCs. Using JDAQ it is possible process data from a number of different detector types such as the PET systems at WVU. Because of the inherent flexibility of our processing software, we are also able adjust detector readout parameters during operation to provide the best possible data presentation and calibration parameters. To accommodate the high rate nature of PET detector systems JDAQ was designed to be scalable across an Ethernet network as well as for multi-cpu computer systems, and it also has the capability to synchronize many ADCs connected to multiple computers. During the project WVU will provided iterative reconstruction algorithm expertise and Fortran programming assistance to facilitate the conversion to C++ of a JLab developed Fortran positron emission mammography (PEM) reconstruction code. Also WVU provided acceptance testing of the new C++ based PEM reconstruction code. The PEM code is a maximization (MLEM) image reconstruction program that created images from the list-mode data acquired from the PET system.

97 MATHEMATICS AND COMPUTING↗

Prototype Stilbene Neutron Collar II

A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation, using a custom LLNL developed MCNPX, of list mode neutron correlation data on various fuel assemblies. Some of these fuel assemblies have neutron absorbers (burnable Gd poisons) and partial defect s (DU, Fe, Pb pins). Calibration curves (doubles vs 235 U linear mass density) are presented for fast (with Cd lining) mode of operation. The modeling incorporates LLNL developed neutron crosstalk correction algorithms and stilbene light output detector response quench function. Pileup issues are addressed using the LLNL code GamGen / RadSrc to estimate the flux of alpha decay gammas from the fuel assemblies on the stilbene cells with and without Pb shielding. One panel of the prototype collar using 10 high-efficiency 4”x2” stilbene cells from Inrad Optics, using LLNL developed technology, has been constructed and calibrated for optimal PSD and data acquisition electronics. Several sources (AmLi, AmBe, Cf, DD, and DT) have been measured with the single panel and the measured data is consistent with the modeling. A novel part of our work was to determine the light output (LO) quench function for the Inrad 4” x 2” stilbene crystals through a LLNL-MCNPX simulation based optimized fitting of the measured LO data.

42 ENGINEERING↗

PF-4 Seismic Performance Reassessment Project (P-SPRaP), Interim Risk Methodology and Deliverables [Slides]

Background: Interim Risk was added to P-SPRaP (SPR Phase 2) to produce intermediate results which build confidence, exercise methodology, develop early insights, and (most importantly) mitigate LANL pit production program risk. Status: SPR Phase 2 is actively underway, has P-SPRaP project team priority focus, and is targeting completion in FY21 (September 2021). Deliverable: Presentation of interim risk results (loss of confinement for screened in failure modes), list of potential criticisms of Interim Risk approach / methodology that intervenors could raise, cost and schedule for completion of Final Risk.

58 GEOSCIENCES↗

Optimization of Binning Parameters in the Feynman Variance-to-Mean Method for Delayed Neutron Reinterrogation [Poster]

The purpose of this work is to determine the optimal input parameters for analyzing active interrogation data that utilizes the physics of the delayed neutron re-interrogation technique. This work compares the signature from an active neutron measurement of a highly enriched uranium (HEU) system to an active background measurement (i.e., without the HEU item in place). In addition, varying analyses of the NoMAD list-mode detector data are performed to determine whether it is preferential to use a particular analysis bin size for producing Feynman histograms, selection of pulses to prevent discrepancies from buildup, or window of time during the pulsed neutron interrogation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments Execution Plan (IER-518 CED-3a)

As part of the experiment design and planning, the critical experiment design team (CEDT), as well as additional stakeholders, convened a series of meetings to discuss the goals and requirements of execution for this experiment. The slides from these meetings are attached in Appendix A. The following sections summarize the outcome of those discussions and present the planned experimental configurations and measurements. The stated goals of this experiment are as follows: 1) Measure time-tagged list-mode data for configurations exceeding neutron multiplication of 100; 2) Provide intercomparison between LLNL, LANL, and IRSN detector systems and methodologies; 3) Generate experiment execution report(s) useful to a fundamental physics benchmark for the ICSBEP; 4) Leverage existing critical experiment and detector system benchmarks to limit required modeling and uncertainty analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

DAQs Quick Start Guide

DAQs is a Windows® computer app designed to communicate with the Advanced List Mode Module (ALMM), MC-15, and instrumentation based off these platforms. The ALMM communicates with DAQS over the Ethernet using TCP/IP. If you register the IPv4 address of the ALMM on the local network the ALMM can be operated remotely. However, if the ALMM is not connected to the local network then the computer running DAQs will need to be connected directly to the ALMM or an additional Ethernet adapter will need to be installed on the acquisition computer. The IPv4 address can be changed in the rei.ini file located on the µSD card. Please see the appendices for more information on the rei.ini file. This document is intended to be a quick start guide on how to get an ALMM connected to a computer and how to start a data acquisition. DAQs has much more capability than is presented in this document.

97 MATHEMATICS AND COMPUTING↗

Coincidence/Multiplicity Photofission Measurements

An series of experiments using the Idaho National Laboratory (INL) photonuclear inspection system and a Los Alamos National Laboratory (LANL)-supplied, list-mode data acquisition method have shown enhanced performance utilizing pulsed photofission-induced, neutron coincidence counting between pulses of an up-to-10-MeV electron accelerator for nuclear material detection and identification. The enhanced inspection methodology has applicability to homeland security, treaty-related support, and weapon dismantlement applications. For the latter, this technology can directly support of Department of Energy/NA241 programmatic mission objectives relative to future Rocky Ridge-type testing campaigns for active inspection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Variance Preserving Spectral Subsampling

Generating statistically faithful short-duration gamma-ray spectra from a single long measurement is essential in nuclear safeguards, supporting tasks such as algorithm development and machine-learning applications, especially when list-mode data are unavailable. Existing subsampling methods often distort the statistical characteristics of genuine short-duration measurements, leading to biased or unreliable analytical outcomes and thereby undermining downstream tasks. In this work, we compare five subsampling approaches using a benchmark set of 156 genuine replicate spectra collected with a high-purity germanium detector. We evaluate each method with respect to run-to-run variance, channel-to-channel variance, and preservation of total counts (losslessness). Across a wide range of subsampling ratios, only binomial subsampling without replacement consistently reproduces the statistical properties of genuine short-duration spectra, maintaining proper dispersion even in sparse spectral regions and perfectly preserving total counts. These results provide a mathematically principled and practically validated framework for generating synthetically shortened spectra when true short-duration measurements are unavailable.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Space Place Prime

Space Place Prime is public engagement and education software for use on iPad. It targets a multi-generational audience with news, images, videos, and educational articles from the Space Place Web site and other NASA sources. New content is downloaded daily (or whenever the user accesses the app) via the wireless connection. In addition to the Space Place Web site, several NASA RSS feeds are tapped to provide new content. Content is retained for the previous several days, or some number of editions of each feed. All content is controlled on the server side, so features about the latest news, or changes to any content, can be made without updating the app in the Apple Store. It gathers many popular NASA features into one app. The interface is a boundless, slidable- in-any-direction grid of images, unique for each feature, and iconized as image, video, or article. A tap opens the feature. An alternate list mode presents menus of images, videos, and articles separately. Favorites can be tagged for permanent archive. Face - book, Twitter, and e-mail connections make any feature shareable.

Fitzpatrick, Austin J.↗

Enhanced Photofission-based, Coincidence/Multiplicity Inspection Measurements

An enhanced active interrogation system has been developed that integrates a transportable Idaho National Laboratory (INL) photonuclear inspection system, using a pulsed bremsstrahlung source and a reconfigurable neutron detection system, with a Los Alamos National Laboratory (LANL) list-mode data acquisition system. A series of active interrogation experiments have shown enhanced nuclear material detection and identification utilizing pulsed photofission-induced, neutron coincidence/multiplicity counting between pulses of an up-to-10-MeV electron accelerator. This paper describes the integrated inspection system and presents some key shielded and unshielded nuclear material inspection results. The enhanced inspection methodology has applicability to homeland security and possible nuclear weapon dismantlement treaties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗