Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Performance of a 2-micrometer coherent Doppler lidar for wind measurements

Measurements of boundary layer winds are presented using a 2-micrometer coherent Doppler lidar and the optimal performance of the maximum likelihood estimator. The systematic error for single-shot estimates was estimated as 3.6 cm/s using measurements from a stationary hard target. The estimation error for measurements of the radial component of the wind field was determined, as well as the fraction of the estimates that are randomly distributed over the velocity search space, when the signal power is low and speckle fading is important. The results from actual data are compared with the results from ideal simulations. The first direct estimation of the spatial structure function of the radial wind field and of the energy dissipation rate is presented for both horizontal and vertical directions of propagation. The rms estimation error of the velocity estimates is found to be within 30% of ideal performance based on simulation.

Frehlich, Rod↗

Performance of a focused cavity aerosol spectrometer for measurements in the stratosphere of particle size in the 0.06-2.0-micrometer-diameter range

A focused cavity aerosol spectrometer aboard a NASA ER-2 high-altitude aircraft provided high-resolution measurements of the size of the stratospheric particles in the 0.06-2.0-micrometer-diameter range in flights following the eruption of Mount Pinatubo in 1991. Effects of anisokinetic sampling and evaporation in the sampling system were accounted for by means adapted and specifically developed for this instrument. Calibrations with monodisperse aerosol particles provided the instrument's response matrix, which upon inversion during data reduction yielded the particle size distributions. The resultant dataset is internally consistent and generally shows agreement to within a factor of 2 with comparable measurements simultaneously obtained by a condensation nuclei counter, a forward-scattering spectrometer probe, and aerosol particle impactors, as well as with nearby extinction profiles obtained by satellite measurements and with lidar measurements of backscatter.

Jonsson, H. H.↗

Non-local thermodynamic equilibrium limb radiance from O3 and CO2 in the 9-11 micrometer spectral region

Satellite remote sensing of mesospheric and thermospheric O3 abundance in the terrestrial atmosphere often uses 9-11 micrometer thermal emission. In this paper, we apply a line-by-line non-local thermodynamic equilibrium (non-LTE) radiance model to this spectral region and investigate the conditions of LTE breakdown and the effect that this has on the limb radiance measured by an i.r. sounder. Monochromatic and band-integrated radiance calculations have been performed for limb view tangent heights between 55 and 105 km under daytime and nighttime conditions. Non-LTE emission from both O3 and CO2 are shown to be important with the divergence of radiance from LTE values and the diurnal variation being band dependent. We have shown that the contribution of the CO2 bands to the Limb Infrared Monitor of the Stratosphere O3 channel is significant for daytime conditions at tangent heights above about 60 km. A study has been made to choose O3 sounding channel spectral passbands for the High Resolution Dynamics Limb Sounder. High resolution calculations are required to determine those spectral intervals that will filter radiance from selected bands and characterize their non-LTE behavior. This will allow for improved O3 retrievals above 70 km and non-LTE studies.

Edwards, David P.↗

Thermal emission measurements 2000-400/cm (5-25 micrometers) of Hawaiian palagonitic soils and their implications for Mars

The thermal emision of two palagonitic soils, common visible and near infrared spectral analogs for bright soils on Mars, was measured over the wavelength range of 5 to 25 micrometers (2000 to 400/cm) for several partical size separates. All spectra exhibit emissivity features due to vibrations associated with H2O and SiO. The maximum variability of emissivity is approximately 20% in the short wavelength region (5 to 6.5 mirometers, 2000 to 1500/cm), and is more subdued, less than 4%, at longer wavelengths. The strengths of features present in the infrared spectra of Mars cannot be solely provided by emissivity variations of palagonite; some other material or mechanism must provide additional absorptions(s).

Roush, Ted L.↗

Sixteen micrometer Infrared Hot Electron Transistor

ABSTRACT. We have demonstrated a bound to continuum state GaAs/Al(x)Ga(1-x)As infrared hot electron transistor which has a peak response at lambda(sub p) = 16.3 micrometers. An excellent photo-current transfer ratio of alpha(sub p) = 0.12 and very low dark current transfer ratio of alpha(sub d) = 7.2 x 10(exp 5) is achieved at a temperature of T = 60 K.

Gunapala, S. D.↗

13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers

A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.

NASA Discipline Life Sciences Technologies↗

Chemical sensing with pulsed QC-DFB lasers operating at 15.6 micrometers

Pulsed thermoelectrically cooled QC-DFB lasers operating at 15.6 micrometers were characterized for spectroscopic gas sensing applications. A new method for wavelength scanning based on repetition rate modulation was developed. A non-wavelength-selective pyroelectric detector was incorporated in the sensor configuration giving the advantage of room-temperature operation and low cost. Absorption lines of CO2 and H2O were observed in ambient air, providing information about the concentration of these species.

NASA Discipline Life Sciences Technologies↗

Single photon infrared emission spectroscopy: a study of IR emission from UV laser excited PAHs between 3 and 15 micrometers

Single-photon infrared emission spectroscopy (SPIRES) has been used to measure emission spectra from polycyclic aromatic hydrocarbons (PAHs). A supersonic free-jet expansion has been used to provide emission spectra of rotationally cold and vibrationally excited naphthalene and benzene. Under these conditions, the observed width of the 3.3-micrometers (C-H stretch) band resembles the bandwidths observed in experiments in which emission is observed from naphthalene with higher rotational energy. To obtain complete coverage of IR wavelengths relevant to the unidentified infrared bands (UIRs), UV laser-induced desorption was used to generate gas-phase highly excited PAHs. Lorentzian band shapes were convoluted with the monochromator-slit function in order to determine the widths of PAH emission bands under astrophysically relevant conditions. Bandwidths were also extracted from bands consisting of multiple normal modes blended together. These parameters are grouped according to the functional groups mostly involved in the vibration, and mean bandwidths are obtained. These bandwidths are larger than the widths of the corresponding UIR bands. However, when the comparison is limited to the largest PAHs studied, the bandwidths are slightly smaller than the corresponding UIR bands. These parameters can be used to model emission spectra from PAH cations and cations of larger PAHs, which are better candidate carriers of the UIRs.

Non-NASA Center↗

Deposition and dispersion of 1-micrometer aerosol boluses in the human lung: effect of micro- and hypergravity

We performed bolus inhalations of 1-micrometer particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (microG) and in approximately 1.6 G. Boluses of approximately 70 ml were inhaled at different points in an inspiration from residual volume to 1 liter above functional residual capacity. The volume of air inhaled after the bolus [the penetration volume (Vp)] ranged from 200 to 1,500 ml. Aerosol concentration and flow rate were continuously measured at the mouth. The deposition, dispersion, and position of the bolus in the expired gas were calculated from these data. For Vp >/=400 ml, both deposition and dispersion increased with Vp and were strongly gravity dependent, with the greatest deposition and dispersion occurring for the largest G level. At Vp = 800 ml, deposition and dispersion increased from 33.9% and 319 ml in microG to 56.9% and 573 ml at approximately 1.6 G, respectively (P < 0.05). At each G level, the bolus was expired at a smaller volume than Vp, and this volume became smaller with increasing Vp. Although dispersion was lower in microG than in 1 G and approximately 1.6 G, it still increased steadily with increasing Vp, showing that nongravitational ventilatory inhomogeneity is partly responsible for dispersion in the human lung.

Parabolic Flight↗

Pluto-Charon: Infrared Reflectance from 3.6 to 8.0 Micrometers

We have measured the spectral reflectance of the Pluto-Charon pair at 3.6, 4.5, 5.8, and 8.0 micrometers with the Infrared Array Camera (IRAC) (G. G. Fazzio et al. Ap.J.Supp. 154, 10-17, 2004) on the Spitzer Space Telescope (STS), at eight different longitudes that cover a full rotation of the planet. STS does not have sufficient resolution to separate the light from the planet and the satellite. The image of the Pluto-Charon pair is clearly visible at each of the four wavelengths. We will discuss the spectral reflectance in terms of models that include the known components of Pluto and Charon s surfaces, and evidence for diurnal variations.

Cruikshank, Dale P.↗

10-30 micrometer Maps of the Central 5 parsecs of the Galaxy: Heating of the Cavity and Neutral-Gas Disk

Maps are presented for 10, 20, and 30 micrometers of the central 60' X 90' (RA X Dec) of the galaxy made at approximately 4' resolution with the MSFC bolometer array. The maps are the first to show the thermal emission from dust particles in both the ionized cavity and the neutral-gas ring with high sensitivity and an angular resolution as good as several arcsec.

galaxies galaxy center infrared astronomy↗

Long Wavelength INGaAs/InGaAsP Quantum Well Lasers at [approximately] 2.0 micrometers

InGaAs/InGaAsP strained quantum well buried heterostructure and distributed feedback lasers emitting at wavelengths as long as 2.06 micrometers with low internal loss and threshold currents have been demonstrated for the first time. The room and high temperature characteristics and the threshold gain are discussed.

quantum well lasers indium gallium↗

16 Micrometer Infrared Hot Electron Transistor

We have demonstrated a bound to continuum state GaAs/Al_xGa_(1-x)As infrared hot electron transistor which has a peak response at theta_p = 16.3 micrometers. An excellent photo-current transfer ratio of alpha_p = 0.12 and very low dark current transfer ratio of alpha_d = 7.2x10^(-5) is achieved at a temperature of T = 60 K.

Gunapala, S. D.↗

Aluminum Foils of the Stardust Interstellar Collector: The Challenge of Recognizing Micrometer-sized Impact Craters made by Interstellar Grains

Preliminary Examination (PE) of the Stardust cometary collector revealed material embedded in aerogel and on aluminium (Al) foil. Large numbers of sub-micrometer impact craters gave size, structural and compositional information. With experience of finding and analyzing the picogram to nanogram mass remains of cometary particles, are we now ready for PE of the Interstellar (IS) collector? Possible interstellar particle (ISP) tracks in the aerogel are being identified by the stardust@home team. We are now assessing challenges facing PE of Al foils from the interstellar collector.

Kearsley, A. T.↗

High-Energy 2-Micrometers Doppler Lidar for Wind Measurements

High-energy 2-micrometer wavelength lasers have been incorporated in a prototype coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Calibration tests and sample atmospheric data are presented on wind and aerosol profiling.

Koch, Grady J.↗

Spatially Resolved Imaging at 350 Micrometers of Cold Dust in Nearby Elliptical Galaxies

Continuum observations at 350 micrometers of seven nearby elliptical galaxies for which CO gas disks have recently been resolved with interferometry mapping are presented. These SHARC II mapping results provide the first clearly resolved far-infrared (FIR)-to-submillimeter continuum emission from cold dust (with temperatures 31 K is approximately greater than T approximately greater than 23 K) of any elliptical galaxy at a distance greater than 40 Mpc. The measured FIR excess shows that the most likely and dominant heating source of this dust is not dilute stellar radiation or cooling flows, but rather star formation that could have been triggered by an accretion or merger event and fueled by dust-rich material that has settled in a dense region cospatial with the central CO gas disks. The dust is detected even in two cluster ellipticals that are deficient in H (sub I), showing that, unlike H (sub I), cold dust and CO in ellipticals can survive in the presence of hot X-ray gas, even in galaxy clusters. No dust cooler than 20 K, either distributed outside the CO disks or cospatial with and heated by the entire dilute stellar optical galaxy (or very extended H (sub I)), is currently evident.

photometry↗