Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

A microscopic realization of dS$_3$

We propose a precise duality between pure de Sitter quantum gravity in 2+1 2 + 1 dimensions and a double-scaled matrix integral. This duality unfolds in two distinct aspects. First, by carefully quantizing the gravitational phase space, we arrive at a novel proposal for the quantum state of the universe at future infinity. We compute cosmological correlators of massive particles in the universe specified by this wavefunction. Integrating these correlators over the metric at future infinity yields gauge-invariant observables, which are identified with the string amplitudes of the complex Liouville string [S. Collier et al., arXiv: 2409.17246]. This establishes a direct connection between integrated cosmological correlators and the resolvents of the matrix integral dual to the complex Liouville string, thereby demonstrating one aspect of the dS _3 3 /matrix integral duality. The second aspect concerns the cosmological horizon of the dS static patch and the Gibbons-Hawking entropy it is conjectured to encode. We show that this entropy can be reproduced exactly by counting the entries of the matrix.

Collier, Scott (ORCID:0000000286476653)↗

Microscopic 3D Graphene for High-Performance Supercapacitors with Ultra-High Areal Capacitance

Despite graphene being considered as an ideal supercapacitor electrode material, its use in commercial devices is limited because few methods exist to produce high-quality graphene at large scale and low-cost. We report a simple method to synthesize 3D graphene by graphenization of coal tar pitch with a K2CO3 catalyst. This produces 3D graphenes with high specific surface areas up to 2113 m2 g-1 and exceptional crystallinity (Raman ID/IG as low as ~ 0.15). The material has an outstanding specific capacitance of 182.6 F g-1 at a current density of 1.0 A g-1. This occurs at mass loading of 30 mg cm-2 which is 3 times higher than commercial requirements, yielding an ultra-high areal capacitance of 5.48 F cm-2. Moreover, the K2CO3 is recycled and reused over 10 cycles. The synthesis method and resulting electrocapacitive performance properties create new opportunities for using 3D graphene more broadly in practical supercapacitor devices.

Pham, Viet Hung↗

Synthesis of Microscopic 3D Graphene for High-Performance Supercapacitors with Ultra-High Areal Capacitance

This presentation was given at the 2024 AIChE Annual Meeting, San Diego, CA, October 27-31, 2024. This presentation describes a low-cost and scalable method to convert coal tar pitch into high-quality 3D graphene with high surface area, hierarchical pore size distribution, and high electrical conductivity which allows for the creation of supercapacitor electrodes with ultra-high mass loading (30 mg/cm2), leading to ultra-high areal capacitance.

Pham, Viet Hung↗

Microscopic Measurement: Need for Nuclear Material Sample Specimen Characterization Capability

The Surveillance, Fabrication, and Off-Site Operations team at Lawrence Livermore National Laboratory is beginning an update to the nuclear material machining lab in Superblock. Plutonium and other nuclear materials tend to accelerate the aging process for equipment and machines that would otherwise be maintainable for long lives. They have their lifespans shortened from deteriorated seals, embrittled polymer components, accelerated corrosion, and damage to electronics from exposure to radioactive materials. The cost of installation of equipment into a glove box (GB) tends to outstrip the cost of the equipment itself. Due to the magnification of cost, the historical approach to equipment installs has been to purchase and install the highest-quality and most robust equipment available to maximize time between failures and updates. To make room for the installation of a new lathe, the inspection GB is being moved to a different location within the machining lab. As part of the overall effort, the equipment within the inspection GB is being revisited. Current measurement capabilities are antiquated and starting to become problematic due to age. Advances in metrology are sought for more comprehensive characterization of scientific samples. This document aims to identify several options for the replacement of current measurement equipment and identify a system for purchase and eventual installation. The intention is not to select the cheapest system, but rather to identify a system that best meets the needs of both the operators and principal investigators (PI). Following the convention of the SYSM-5620 Design Thinking and System Engineering, it was determined that a laser confocal measurement system from Keyence is the most suitable option for our programmatic need. Form factor, capability, and maintainability were considered. Along with stakeholder input, to ensure the best decision for the Nuclear Material Technology Program.

36 MATERIALS SCIENCE↗

An Advanced Microscopic Energy Consumption Model for Automated Vehicle:Development, Calibration, Verification

The automated vehicle (AV) equipped with the Adaptive Cruise Control (ACC) system is expected to reduce the fuel consumption for the intelligent transportation system. This paper presents the Advanced ACC-Micro (AA-Micro) model, a new energy consumption model based on micro trajectory data, calibrated and verified by empirical data. Utilizing a commercial AV equipped with the ACC system as the test platform, experiments were conducted at the Columbus 151 Speedway, capturing data from multiple ACC and Human-Driven (HV) test runs. The calibrated AA-Micro model integrates features from traditional energy consumption models and demonstrates superior goodness of fit, achieving an impressive 90% accuracy in predicting ACC system energy consumption without overfitting. A comprehensive statistical evaluation of the AA-Micro model's applicability and adaptability in predicting energy consumption and vehicle trajectories indicated strong model consistency and reliability for ACC vehicles, evidenced by minimal variance in RMSE values and uniform RSS distributions. Conversely, significant discrepancies were observed when applying the model to HV data, underscoring the necessity for specialized models to accurately predict energy consumption for HV and ACC systems, potentially due to their distinct energy consumption characteristics.

Ma, Ke↗

Spectro-Microscopic Investigation of the Aerosol Impact on Hydrological Processes

This project investigated physico-chemical characteristics of atmospheric particles collected during DOE ARM field campaigns and how they are involved in the hydrological cycle. Our efforts were focused on multi-modal chemical imaging and molecular characterization of atmospheric particles and snow samples collected during the Surface-Atmosphere Integrated Field Laboratory (SAIL) campaign and particle samples from the Tracking Aerosol Convection Interactions ExpeRiment (TRACER) campaign.

54 ENVIRONMENTAL SCIENCES↗

Optimal Geometry for Focused Ion Beam-Milled Samples for Direct-Pull Micro-Tensile Testing Performed In Situ in a Scanning Electron Microscope

A thorough procedure was developed to efficiently manufacture dogbone samples using focused ion beam (FIB) milling for micro-tensile testing. A Bruker PI 89 PicoIndenter, Billerica, MA, USA, was used as a case study, although the analysis and results are applicable to other micro-mechanical testing systems capable of mounting a standard, Ø12.7 mm × Ø3.2 mm pin, scanning electron microscopy (SEM) pin stub (Ted Pella, Redding, CA, USA). Nine dogbones were made from an Fe-45Cu alloy additively manufactured using powder-fed laser-directed energy deposition (DED-LB). Testing showed that fracture was confined to the gauge section for all dogbones and that the fracture mode, ductile vs. brittle, was entirely dependent on the grain orientation relative to the loading direction. The analysis showed that the measured plastic strain to failure can vary from >11% (optimal geometry) to <1% (non-optimal geometry) in micro-tensile testing of high-tensile-strength (>1 GPa) metallic materials. Subsequently, a finite element analysis (FEA) was conducted to identify the improved dogbone geometries. A total of ten thousand dogbone geometries were tested, and their dimensions were defined by a set of four adjustable parameters (corner radius, load surface angle, load surface length, and dogbone head length). The gauge width and gauge length were fixed to 4 µm and 10 µm, respectively. Three-dimensional surface plots of the stress concentration as a function of two parameters were used to identify the optimal ranges of parameter values. The addition of maximum width and length constraints, measuring 25 µm and 30 µm, respectively, allowed us to identify an optimal geometry at load surface angles of 30° and 45°. Their respective dimensions (corner radius, load surface length, and dogbone head length) are, in µm, 12, 6, and 7 and 10, 7, and 7. Testing these two optimal geometries with a range of gauge lengths from 4 to 20 µm showed that smaller gauge lengths only slightly reduced the detrimental stress concentration outside the gauge section. However, smaller gauge lengths will notably improve the FIB surface polishing step as tapering is reduced with smaller dogbone lengths.

Chemistry↗

Workflow Using a Cryogenic Coincident Fluorescence, Electron, and Ion Beam Microscope for Targeted Milling of Cells

This workflow enables lamella production targeting fluorescently labeled biological structures that are small (<1 μm in axial extent) and rare (1 copy per cell) using a cryogenic tri-coincident imaging platform. In conclusion, this platform integrates fluorescence microscopy, focused ion beam milling, and scanning electron microscopy at a single focal position and enables simultaneous fluorescence microscopy while milling.

Wang, Jue [California Institute of Technology (Cal↗

Microscopic Derivation of Transition-state Theory for Complex Quantum Systems

The decay of quantum complex systems through a potential barrier is often described with transition-state theory, also known as RRKM theory in chemistry. Here we derive the basic formula for transition-state theory based on a generic Hamiltonian as might be constructed in a configuration-interaction basis. Two reservoirs of random Hamiltonians from Gaussian orthogonal ensembles are coupled to intermediate states representing the transition states at a barrier. Under the condition that the decay of the reservoirs to open channels is large, an analytic formula for reaction rates is derived. Here, the transition states act as independent Breit–Wigner resonances which contribute additively to the total transition probability, as is well known for electronic conductance through resonant tunneling states. It is also found that the transition probability is independent of the decay properties of the states in the second reservoir over a wide range of decay widths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The 3D Quantum Microscope

Explore the source record for details and available documents.

Biological and medical sciences, Optics and optica↗