Search NASA⌕ Search

SEARCH · Search NASA

Results for “PI control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fault diagnosis and fault tolerant control for T-S fuzzy stochastic distribution systems subject to sensor and actuator faults

The problem of fault diagnosis (FD) and fault tolerant control (FTC) for a class of Takagi-Sugeno (T-S) fuzzy stochastic distribution control (SDC) systems subject to sensor and actuator faults is discussed in this paper. First, fuzzy logic models are used to approximate the output probability density function (PDF). Next, an adaptive augmented state/fault diagnosis observer is proposed to estimate the system state, sensor and the actuator faults simultaneously. New expected weights based on the sensor fault estimation information and a PI-type fuzzy feedback fault tolerant (FT) controller are designed to compensate the effect of sensor fault and actuator fault simultaneously. When the sensor fault occurs, the expected objective is redesigned to compensate the sensor fault. Meanwhile, the PI controller can compensate the effect of actuator fault, and the output PDF of the system can still track the desired PDF after the fault occurs. Finally, an example of quality distribution control in chemical reaction process is given to confirm the effectiveness of the algorithm.

42 ENGINEERING↗

Modified Adaptive Control for Region 3 Operation in the Presence of Wind Turbine Structural Modes

Many challenges exist for the operation of wind turbines in an efficient manner that is reliable and avoids component fatigue and failure. Turbines operate in highly turbulent environments resulting in aerodynamic loads that can easily excite turbine structural modes, possibly causing component fatigue and failure. Wind turbine manufacturers are highly motivated to reduce component fatigue and failure that can lead to loss of revenue due to turbine down time and maintenance costs. The trend in wind turbine design is toward larger, more flexible turbines that are ideally suited to adaptive control methods due to the complexity and expense required to create accurate models of their dynamic characteristics. In this paper, we design an adaptive collective pitch controller for a high-fidelity simulation of a utility-scale, variable-speed horizontal axis wind turbine operating in Region 3. The objective of the adaptive pitch controller is to regulate generator speed, accommodate wind gusts, and reduce the excitation of structural modes in the wind turbine. The control objective is accomplished by collectively pitching the turbine blades. The adaptive collective pitch controller for Region 3 was compared in simulations with a baseline classical Proportional Integrator (PI) collective pitch controller. The adaptive controller will demonstrate the ability to regulate generator speed in Region 3, while accommodating gusts, and reducing the excitation of certain structural modes in the wind turbine.

Frost, Susan Alane↗

Augmented Adaptive Control of a Wind Turbine in the Presence of Structural Modes

Wind turbines operate in highly turbulent environments resulting in aerodynamic loads that can easily excite turbine structural modes, potentially causing component fatigue and failure. Two key technology drivers for turbine manufacturers are increasing turbine up time and reducing maintenance costs. Since the trend in wind turbine design is towards larger, more flexible turbines with lower frequency structural modes, manufacturers will want to develop methods to operate in the presence of these modes. Accurate models of the dynamic characteristics of new wind turbines are often not available due to the complexity and expense of the modeling task, making wind turbines ideally suited to adaptive control. In this paper, we develop theory for adaptive control with rejection of disturbances in the presence of modes that inhibit the controller. We use this method to design an adaptive collective pitch controller for a high-fidelity simulation of a utility-scale, variable-speed wind turbine operating in Region 3. The objective of the adaptive pitch controller is to regulate generator speed, accommodate wind gusts, and reduce the interference of certain structural modes in feedback. The control objective is accomplished by collectively pitching the turbine blades. The adaptive pitch controller for Region 3 is compared in simulations with a baseline classical Proportional Integrator (PI) collective pitch controller.

Frost, Susan A.↗

Laboratory plasma interactions experiments: Results and implications to future space systems

The experimental results discussed show the significance of the effects caused by spacecraft plasma interactions, in particular the generation of Electromagnetic Interference. As the experimental results show, the magnitude of the adverse effects induced by Plasma Interactions (PI) will be more significant for spacecraft of the next century. Therefore, research is needed to control possible adverse effects. Several techniques to control the selected PI effects are discussed. Tests, in the form of flight experiments, are needed to validate these proposed ideas.

Leung, Philip↗

A New Class of Nonlinear PID Controllers

This paper introduces a new class of simple nonlinear PID-type controllers comprised of a sector-bounded nonlinear gain in cascade with a linear fixed-gain P, PD, PI, or PID controller.

PID Contollers nonlinear gains↗

Designing of smart home automation system based on Raspberry Pi

Locally networked or remotely controlled home automation system becomes a popular paradigm because of the numerous advantages and is suitable for academic research. This paper proposes a method for an implementation of Raspberry Pi based home automation system presented with an android phone access interface. The power consumption profile across the connected load is measured accurately through programming. Users can access the graph of total power consumption with respect to time worldwide using their Dropbox account. An android application has been developed to channelize the monitoring and controlling operation of home appliances remotely. This application facilitates controlling of operating pins of Raspberry Pi by pressing the corresponding key for turning “on” and “off” of any desired appliance. Systems can range from the simple room lighting control to smart microcontroller based hybrid systems incorporating several other additional features. Smart home automation systems are being adopted to achieve flexibility, scalability, security in the sense of data protection through the cloud-based data storage protocol, reliability, energy efficiency, etc.

42 ENGINEERING↗

A New Approach to Robot Motor Control

This poster details the motor control improvements to Fermilab's Remote Viewing Robot (RVR). It is a robot tasked with remotely investigating issues within the accelerator tunnels at Fermilab. Initially controlled by a single Raspberry Pi that housed all the robot s operations, the RVR will now use a Raspberry Pi Pico W for its motor control. This was achieved using Pulse Width Modulation (PWM) to allow for precise speed and torque control for the robot. This enhances the robot s reliability. By addressing the challenge of navigating high radiation environments, the upgrade helps assist the RVR s goal of decreasing the need for human intervention in accelerator tunnels.

Lopez, Jacob↗

A New Approach to Robot Motor Control

This essay details the motor control improvements to Fermilab's Remote Viewing Robot (RVR). It is a robot tasked with remotely investigating issues within the accelerator tunnels at Fermilab. Initially controlled by a single Raspberry Pi that housed all the robot s operations, the RVR will now use a Raspberry Pi Pico W for its motor control. This was achieved using Pulse Width Modulation (PWM) to allow for precise speed and torque control for the robot. This enhances the robot s reliability. By addressing the challenge of navigating high radiation environments, the upgrade helps assist the RVR s goal of decreasing the need for human intervention in accelerator tunnels.

Lopez, Jacob↗

Towards an intuitive application of WEC control co-design

A simple co-design example in a reduced parameter space is presented for an oscillating flap device. Initially, the WEC geometry and mass properties are considered along with drivetrain gear ratio, inertia, motor constant and stiffness under both PI and optimal control. This parameter space is reduced to those to which performance is most sensitive for a fixed geometry. The gear ratio, drivetrain stiffness, and flap mass are found to be the most impactful design criteria as they can create orders of magnitude variations in power performance. The performance of the optimized system is compared with several sub-optimal variants in terms of electrical and mechanical power capture, transmission coefficients, and transducer power gain. Notably, though substantial power capture improvements are demonstrated when an optimal controller is employed, this power capture remains sensitive to appropriate selections of drivetrain and flap design parameters, implying that control co-design procedures remain necessary for high-performing WECs. Furthermore, a number of practical caveats and extensions to the presented co-design methodology are suggested, including the characterization of system static friction, especially in the presence of high gear ratios.

Control co-design↗

Sensor-Based Collision Avoidance: Theory and Experiments

A new on-line control strategy for sensor-based collision avoidance of manipulators and supporting experimental results are presented in this article. This control strategy is based on nullification of virtual forces applied to the end-effector by a hypothetical spring-plus-damper attached to the object's surface. In the proposed approach, the real-time arm control software continuously monitors the object distance measured by the arm-mounted proximity sensors. When this distance is less than a preset threshold, the collision avoidance control action is initiated to inhibit motion toward the object and thus prevent collision. This is accomplished by employing an outer feedback loop to perturb the end-effector nominal motion trajectory in real-time based on the sensory data. The perturbation is generated by a proportional-plus-integral (PI) collision avoidance controller acting on the difference between the sensed distance and the preset threshold. This approach is computationally very fast, requires minimal modification to the existing manipulator positioning system, and provides the manipulator with an on-line collision avoidance capability to react autonomously and intelligently. A dexterous RRC robotic arm is instrumented with infrared proximity sensors and is operated under the proposed collision avoidance strategy. Experimental results are presented to demonstrate end-effector collision avoidance both with an approaching object and while reaching inside a constricted opening.

Seraji, Homayoun↗

System dynamic model and charging control of lead-acid battery for stand-alone solar PV system

The lead-acid battery which is widely used in stand-alone solar system is easily damaged by a poor charging control which causes overcharging. The battery charging control is thus usually designed to stop charging after the overcharge point. This will reduce the storage energy capacity and reduce the service time in electricity supply. The design of charging control system however requires a good understanding of the system dynamic behaviour of the battery first. In the present study, a first-order system dynamics model of lead-acid battery at different operating points near the overcharge voltage was derived experimentally, from which a charging control system based on PI algorithm was developed using PWM charging technique. The feedback control system for battery charging after the overcharge point (14 V) was designed to compromise between the set-point response and the disturbance rejection. The experimental results show that the control system can suppress the battery voltage overshoot within 0.1 V when the solar irradiation is suddenly changed from 337 to 843 W/m{sup 2}. A long-term outdoor test for a solar LED lighting system shows that the battery voltage never exceeded 14.1 V for the set point 14 V and the control system can prevent the battery from overcharging. The test result also indicates that the control system is able to increase the charged energy by 78%, as compared to the case that the charging stops after the overcharge point (14 V). (author)

14 SOLAR ENERGY↗

Breakdown of partial conservation of axial current in diffractive neutrino interactions

We test the hypothesis of partially conserved axial current in high-energy diffractive neutrino production of pions. Since the pion pole contribution to the Adler relation (AR) is forbidden by conservation of the lepton current, the heavier states, like the a{sub 1} pole, {rho}-{pi} cut, etc., control the lifetime of the hadronic fluctuations of the neutrino. We evaluate the deviation from the AR in diffractive neutrino production of pions on proton and nuclear targets. At high energies, when all the relevant time scales considerably exceed the size of the target, the AR explicitly breaks down on an absorptive target, such as a heavy nucleus. In this regime, close to the black disk limit, the off-diagonal diffractive amplitudes vanish, while the diagonal one, {pi}{yields}{pi}, which enters the AR, maximizes and saturates the unitarity bound. At lower energies, in the regime of short lifetime of heavy hadronic fluctuations the AR is restored, i.e., it is not altered by the nuclear effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Era for Modern Bubble Chamber Technology: Cooling and Real-Time Control for the MAMBA Neutrino Bubble Chamber∗

Future neutrino experiments such as DUNE will be limited less by statistics than by how well neutrino--nucleus interactions are understood, and the cleanest way to improve that understanding is to measure interactions with light nuclei such as hydrogen or deuterium. The detector best suited to the job, the bubble chamber, has not been built for a neutrino beam in about fifty years. MAMBA (Modern Adaptive Modular Bubble chamber Archetype) is a small prototype at Fermilab intended to bring the technology back with modern cryogenics and automation, cycling continuously at 1~Hz. This paper summarizes my work on two of its subsystems during a summer internship. A new solid copper thermal link brought the coldhead to 21.3~K in a commissioning cooldown, near the 20~K operating target. An Industrial Shields Raspberry Pi programmable logic controller (PLC) running OpenPLC was characterized at a median round-trip response of 0.64~ms over 20,000 trials, with 0.66\% of trials exceeding 1~ms. Both results support continuous cycling.

Williams, Nicholas [Fermilab; DuPage Coll.]↗

Considerations for testing full-scale wind turbine nacelles with hardware-in-the-loop

In this paper, pole placement control techniques are utilized to compensate for variations in the torsional dynamics resulting from the different boundary conditions experienced by a wind turbine nacelle when mounted on a test bench. Simulation case studies are used to understand the baseline torsional characteristics of the nacelle coupled to the test bench versus that coupled to the rotor. It was found that the frequency shifts by up to 200% and 400% for the first and second torsional modes, respectively. The feasibility of utilizing pole placement technique to match the torsional characteristics of the turbine on the test bench is investigated using PI and PID controllers. Here, the performance of the tuned controller is then verified under two test scenarios: Low Voltage Ride Through (LVRT), and a highly dynamic turbulent wind input. It is demonstrated that tuning the test bench speed controller can effectively shift the poles of the closed-loop system to match the desired first and second modes of the full turbine and replicate transient field events on the test bench.

17 WIND ENERGY↗

Reduced-Order Aggregate Model for Parallel-Connected Single-Phase Inverters

This paper outlines a reduced-order aggregate dynamical model for parallel-connected single-phase grid-connected inverters. For each inverter, we place no restrictions on the converter topology and merely assume that the ac-side switch-averaged voltage can be controlled via pulsewidth modulation. The ac output of each inverter interfaces through an LCL filter to the grid. The closed-loop system contains a phase locked loop for grid synchronization, and real- and reactive-power control are realized with inner and outer PI current- and power-control loops. We derive a necessary and sufficient set of parametric relationships to ensure that a reduced-order aggregated state-space model for an arbitrary number of such paralleled inverters has the same model order and structure as any single inverter. We also present reduced-order models for the settings where the real- and reactive-power setpoints are different and where the inverters have different power ratings. We anticipate the proposed model being useful in analyzing the dynamics of large collections of parallel-connected inverters with minimal computational complexity. The aggregate model is validated against measurements obtained from a multi-inverter experimental setup consisting of three 750-VA paralleled grid-connected inverters, hence establishing robustness of the analytical result to parametric variations seen in practice.

24 POWER TRANSMISSION AND DISTRIBUTION↗