Search NASA⌕ Search

SEARCH · Search NASA

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Image Analysis for Plug Bubbles in Horizontal Flow

Horizontal plug flow is different from horizontal slug flow in that relatively few small bubbles exist in plug flow, whereas slug flow is characterized by highly aerated liquid slugs and liquid films. While the nose position and nose propagation velocity of plug bubbles may provide physical insights in understanding the flow regime transition mechanism between the plug and slug flows, few systematic investigations on these parameters have been performed in previous research. In view of this, this paper presents the development of an image processing method for the purpose of (a) obtaining data for nose position and nose propagation velocity of plug bubbles and (b) benchmarking local four-sensor conductivity probe measurements of time-averaged bubble velocity and void fraction. (authors)

42 ENGINEERING↗

Neutronics Analysis for ITER Diagnostic Generic Upper Port Plug

This paper presents new results of neutronics analysis performed for the updated design of the ITER Diagnostic Generic Upper Port Plug (DGUPP). Such analysis is performed regularly during the development of the ITER Ports design. Neutronics analysis is an important step in support of the development of ITER components irradiated by 14 MeV neutrons generated in D-T fusion thermonuclear reactions. The neutrons are born in the ITER tokamak plasma chamber and then impinge on the surrounding blanket and port plugs, after that they diffuse through shielding material of vacuum vessel components or could stream through the diagnostic channels and assembly gaps far away from plasma up to the bio-shield and in a small amount beyond it. While ITER machine is in operation it is inaccessible, after the shut-down it is planned to provide personnel access to the Upper Port Inter-Space Structure (UP ISS) behind the Port Plug via the corridors. Neutrons activate the ITER materials and those radioactive materials emit decay gammas during the shut-down causing a Shut-Down Dose Rate (SDDR) field distributed all around the activated materials. Decay gammas could also stream through the void channels. That emphasizes the need for calculation of decay gamma transport in evaluations of SDDR, which is reflected in the use of transport - activation interface code described in Section of Computational Modelling. The assessment of radiation environment (fluxes and SDDR) at DGUPP was focused on the port back-side area of UP ISS, where personnel access is planned along the ISS maintenance corridors. Minimization of SDDR at the front part of the ISS maintenance corridors was the target value for optimization of the DGUPP shielding and analysis of related neutronics effects. Following the dose ALARA (As Low As Reasonably Achievable) principle, every possibility to reduce SDDR should be investigated, emphasizing the importance of this analysis. The challenges of such analysis are inextricably connected with the engineering complexity of the ITER machine, with integration of many diagnostics systems having channels and gaps inside the ITER ports. Those gaps result in radiation streaming and negatively affect the shielding performance of the port plugs. The computational complication is caused by the need to model precisely the ITER geometry and then to run deep penetrating radiation transport in the substantially heterogenic toroidal geometry of ITER large-size tokamak, with 30 m height and diameter of its bio-shield. The whole mass of Upper Port Plug (UPP) could be up to 25 tons and it must be very precisely positioned inside the port opening in blanket and Vacuum Vessel. Facing the engineering challenges for the assembly of DGUPP, there were proposed two Project Change Requests (PCRs) No. 439 and 709 concerning the design updates of UPP/blanket interface and its remote handling.

61 RADIATION PROTECTION AND DOSIMETRY↗

Plug-Load Control and Behavioral Change Research in GSA Office Buildings

The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-load energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Plug-In Electric Vehicle Infrastructure Analysis

This document describes a study conducted by the National Renewable Energy Laboratory quantifying the charging station infrastructure required to serve the growing U.S. fleet of plug-in electric vehicles (PEVs). PEV sales, which include plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs), have surged recently. Most PEV charging occurs at home, but widespread PEV adoption will require the development of a national network of non-residential charging stations. Installation of these stations strategically would maximize the economic viability of early stations while enabling efficient network growth as the PEV market matures. This document describes what effective co-evolution of the PEV fleet and charging infrastructure might look like under a range of scenarios. To develop the roadmap, NREL analyzed PEV charging requirements along interstate corridors and within urban and rural communities. The results suggest that a few hundred corridor fast-charging stations could enable long-distance BEV travel between U.S. cities. Compared to interstate corridors, urban and rural communities are expected to have significantly larger charging infrastructure requirements. About 8,000 fast-charging stations would be required to provide a minimum level of coverage nationwide. In an expanding PEV market, the total number of non-residential charging outlets or 'plugs' required to meet demand ranges from around 100,000 to more than 1.2 million. Understanding what drives this large range in capacity requirements is critical. For example, whether consumers prefer long-range or short-range PEVs has a larger effect on plug requirements than does the total number of PEVs on the road. The relative success of PHEVs versus BEVs also has a major impact, as does the number of PHEVs that charge away from home. This study shows how important it is to understand consumer preferences and driving behaviors when planning charging networks.

33 ADVANCED PROPULSION SYSTEMS↗

Conceptual Design of an Improved Sodium Plugging Loop

Based upon lessons learned in operating the initial sodium portion of the Sodium Plugging Phenomena Loop that itself became plugged and could not be unplugged, a set of improved design features have been identified for a new sodium loop that is less prone to inadvertent plugging. The new design features include a new sodium vessel that combines the functionalities of an expansion tank and a cold trap, increasing the loop tubing diameter/size, improving the thermal designs of the pump and flow meter, improved heater zoning, and an improved temperature distribution strategy along the loop. A new plugging loop conceptual design implementing these features has been developed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Porous Plug Phase Separator and Superfluid Film Flow Suppression System for the Soft X-Ray Spectrometer Onboard Hitomi

When using superfluid helium in low gravity environments, porous plug phase separators are commonly used to vent boiloff gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ~ 30 ug/s, equivalent to ~ 0.7 mW heat load. It is therefore critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 ug/s, corresponding to a loss of cooling capacity of <40 uW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. In this paper, design, on-ground testing results and in-orbit performance are described.

Porous↗

Engaging Tenants in Reducing Plug Load Energy Use

Plug and Process Loads (PPLs) account for an increasingly large percentage of commercial building energy use in the U.S. due to the rising number of energy intensive plug-in devices. In addition, buildings are becoming more and more efficient and plug load energy use has become an increasingly pertinent component to achieving aggressive energy targets and netzero energy status. For multi-tenant buildings, controlling plug loads in tenant spaces can be a significant challenge. Luckily, there are a number of PPL reduction strategies, best practices, and lessons learned from numerous commercial real estate and higher education leaders who have successfully engaged building occupants and tenants in reducing PPL energy use. This paper provides actionable PPL reduction strategies and best practices that building owners and managers can immediately apply to their own buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Plug-In Electric Vehicle Infrastructure Analysis

This presentation describes a study conducted by the National Renewable Energy Laboratory quantifying the charging station infrastructure required to serve the growing U.S. fleet of plug-in electric vehicles (PEVs). PEV sales, which include plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs), have surged recently. Most PEV charging occurs at home, but widespread PEV adoption will require the development of a national network of non-residential charging stations. Installation of these stations strategically would maximize the economic viability of early stations while enabling efficient network growth as the PEV market matures. This document describes what effective co-evolution of the PEV fleet and charging infrastructure might look like under a range of scenarios. To develop the roadmap, NREL analyzed PEV charging requirements along interstate corridors and within urban and rural communities. The results suggest that a few hundred corridor fast-charging stations could enable long-distance BEV travel between U.S. cities. Compared to interstate corridors, urban and rural communities are expected to have significantly larger charging infrastructure requirements. About 8,000 fast-charging stations would be required to provide a minimum level of coverage nationwide. In an expanding PEV market, the total number of non-residential charging outlets or 'plugs' required to meet demand ranges from around 100,000 to more than 1.2 million. Understanding what drives this large range in capacity requirements is critical. For example, whether consumers prefer long-range or short-range PEVs has a larger effect on plug requirements than does the total number of PEVs on the road. The relative success of PHEVs versus BEVs also has a major impact, as does the number of PHEVs that charge away from home. This study shows how important it is to understand consumer preferences and driving behaviors when planning charging networks.

25 ENERGY STORAGE↗

Utah FORGE: Optimization of a Plug-and-Perf Stimulation (Fervo Energy)

Information around the plug-and-perf treatment design at Utah FORGE by Fervo Energy. Objective and Purpose: - Develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS system: i) Achieving sufficient injectivity to support high cross-well flow rates ii) Distributing flow evenly across the wellbore and reservoir to maximize heat mining efficiency, ensure sustained heat transfer, and mitigate thermal breakthrough iii) Overcoming the effects of stress heterogeneity, stress shadowing, and variations in natural fracture properties during the stimulation treatment, leading to a more predictable stimulated reservoir volume and offset well placement - The following activities will be performed: i) Design, plan, and execute a multistage plug-and-perf stimulation treatment at a Fervo site with data acquisition and well testing activities aimed at addressing key technical aspects of the issues above ii) Perform data processing and interpretation of field results to translate the results form the Fervo site to a site-specific design at the Utah FORGE site iii) Design, plan, and execute a multistage plug-and-perf stimulation treatment design at the Utah FORGE site Methods and Approach: - Design a detailed data acquisition plan to maximize learning around: i) DFIT testing ii) Petrophysical logging, image logging iii) Permanent DAS/DTS fiber optic monitoring iv) Deep borehole microseismic monitoring v) Shallow borehole induced seismicity monitoring vi) Injection/production testing (RTA analysis, tracer testing) vii) Integrated numerical modeling and production forecasting

15 GEOTHERMAL ENERGY↗

Emerging Plug Load Management Technologies that Save Energy and Time

This fact sheet introduces two emerging technologies that could streamline plug load management (PLM) for increased energy savings for building owners: learning behavior algorithms (LBA) and automatic and dynamic load detection (ADLD). Plug loads are responsible for 47% of the energy consumed in commercial buildings, yet their distributed and ever-changing nature makes them challenging to manage. PLM systems exist today that use smart plugs to meter and control devices at the outlet level, but their uptake has been relatively slow in part because of the significant labor required for installation and maintenance. LBA and ADLD may address these challenges and provide additional energy efficiency and nonenergy benefits.

Plug and process loads, PPL, plug loads, plug load↗

Flow‐to‐fracture transition in a volcanic mush plug may govern normal eruptions at Stromboli

Abstract Stromboli is a model volcano for studying eruptions driven by degassing. The current paradigm posits that Strombolian eruptions represent the bursting of gas slugs ascending through melt‐filled conduits, but petrological observations show that magma at shallow depth is crystalline enough to form a three‐phase plug consisting of crystals, bubbles, and melt. We combine a 1‐D model of gas flushing a crystalline mush with a 3‐D stress model. Our results suggest that localized gas segregation establishes hot conduits of mobile magma within a stagnant plug. The plug is prone to tensile failure controlled by gas overpressure and tectonic stress, with failure most likely beneath the observed vent locations. We hence argue that Strombolian eruptions are related to plug failure rather than flow. Our proposed three‐phase model of the shallow plumbing system may provide a promising framework for integrating geophysical, petrological, and morphological observations at Stromboli and in open‐system volcanism more generally.

Suckale, J.↗

Solvent viscosity mismatch between the solute plug and the mobile phase: Considerations in the applications of two-dimensional HPLC

Understanding the nature of viscosity contrast induced flow instabilities is an important aspect in the design of two-dimensional HPLC separations. When the viscosity contrast between the sample plug and the mobile phase is sufficiently large, the phenomenon known as viscous fingering can be induced. Viscous fingering is a flow instability phenomenon that occurs at the interface between two fluids with different viscosities. In liquid chromatography, viscous fingering results in the solute band undergoing a change in form as it enters into the chromatography column. Moreover, even in the absence of viscous fingering, band shapes change shape at low viscosity contrasts. These changes can result in a noticeable change in separation performance, with the result depending on whether the solvent pushing the solute plug has a higher or lower viscosity than the solute plug. These viscosity induced changes become more important as the solute injection volume increases and hence understanding the process becomes critical in the implementation of multidimensional HPLC techniques, since in these techniques the sample injection plug into the second dimension is an order of magnitude greater than in one-dimensional HPLC. This review article assesses the current understanding of the viscosity contrast induced processes as they relate to liquid chromatographic separation behaviour.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast production of large {sup 23}Na Bose-Einstein condensates in an optically plugged magnetic quadrupole trap

We demonstrate a fast production of large {sup 23}Na Bose-Einstein condensates in an optically plugged magnetic quadrupole trap. A single global minimum of the trapping potential is generated by slightly displacing the plug beam from the center of the quadrupole field. With a dark magneto-optical trap and a simple rf evaporation, our system produces a condensate with N{approx_equal}10{sup 7} atoms every 17 s. The Majorana loss rates and the resultant heating rates for various temperatures are measured with and without plugging. The average energy of a spin-flipped atom is almost linearly proportional to temperature and determined to be about 60% of the average energy of a trapped atom. We present a numerical study of the evaporation dynamics in a plugged linear trap.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wall-plug efficiency and beam dynamics in free-electron lasers using energy recovery linacs

In a high average power free-electron laser (FEL) the wall-plug efficiency is of critical importance in determining the size, complexity, and cost of the overall system. The wall-plug efficiency for the FEL oscillator and amplifier (uniform and tapered wiggler) is strongly dependent on the energy recovery process. A theoretical model for electron beam dynamics in the energy recovery linac is derived and applied to the acceleration and deceleration of nano-Coulomb electron bunches for a tapered FEL amplifier. For the tapered amplifier, the spent electron beam exiting the wiggler consists of trapped and untrapped electrons. Decelerating these two populations using different phases of the radio-frequency wave in the recovery process enhances wall-plug efficiency. For the parameters considered here, the wall-plug efficiency for the tapered amplifier can be {approx}10% using this approach.

43 PARTICLE ACCELERATORS↗

Mitigation of Syngas Cooler Plugging and Fouling

This Final Report summarizes research performed to develop a technology to mitigate the plugging and fouling that occurs in the syngas cooler used in many Integrated Gasification Combined Cycle (IGCC) plants. The syngas cooler is a firetube heat exchanger located downstream of the gasifier. It offers high thermal efficiency, but its’ reliability has generally been lower than other process equipment in the gasification island. The buildup of ash deposits that form on the fireside surfaces in the syngas cooler (i.e., fouling) lead to reduced equipment life and increased maintenance costs. Our approach to address this problem is that fouling of the syngas cooler cannot be eliminated, but it can be better managed. The research program was funded by DOE using two budget periods: Budget Period 1 (BP1) and Budget Period 2 (BP2). The project used a combination of laboratory scale experiments, analysis of syngas cooler deposits, modeling and guidance from industry to develop a better understanding of fouling mechanisms and to develop and evaluate strategies to mitigate syngas cooler fouling and thereby improve syngas cooler performance. The work effort in BP 1 and BP 2 focused on developing a better understanding of the mechanisms that lead to syngas cooler plugging and fouling and investigating promising concepts to mitigate syngas cooler plugging and fouling. The work effort focused on the following: • analysis of syngas cooler deposits and fuels provided by an IGCC plant collaborating with this project; • performing Jet cleaning tests in the University of Utah Laminar Entrained Flow Reactor to determine the bond strength between an ash deposit to a metal plate, as well as implementing planned equipment modifications to the University of Utah Laminar Entrained Flow Reactor and the one ton per day, pressurized Pilot Scale Gasifier; • performing Computational Fluid Dynamic modeling of industrially relevant syngas cooler configurations to develop a better understanding of deposit formation mechanisms; • performing Techno-Economic-Analysis for a representative IGCC plant to investigate the impact on plant economics, in particular the impacts on the Cost of Electricity (COE), due to plant shutdowns caused by syngas cooler plugging and fouling and potential benefits to plant economics of developing strategies to mitigate syngas cooler fouling; and • performing modeling and pilot scale tests to investigate the potential benefits of using a sorbent (fuel additive) to capture the vaporized metals that result in syngas cooler fouling. All project milestones for BP 1 and BP 2 were achieved. DOE was provided a briefing on our accomplishments in BP1 and BP2 and our proposed plans for Budget Period 3 (BP 3). Based on our research the mitigation technology selected to investigate in BP 3 was the use of a sorbent that can be injected into the gasifier with the fuel slurry to capture vaporized metals that lead to the deposit formation in the syngas cooler. The work effort proposed for BP 3 would have focused on addressing concerns raised by gasification industry personnel for the impacts on gasifier performance of sorbent injection, so that at the end of BP 3 the use of sorbent injection would be at “pre-commercial” stage and ready for use in a Field Demonstration that could be funded by industry or DOE. A Budget Continuation Application (BCA) was submitted to obtain funding for BP3 DOE but DOE chose to not fund the proposed BP3 effort.

47 OTHER INSTRUMENTATION↗

SAM Plug-in Development (Phase I Final Report)

The DOE Office of Nuclear Energy (NE) has created an extensive set of advanced modeling and simulation tools for nuclear engineering analysis. The advanced capabilities of these newer analysis codes require more in-depth training, skills, and knowledge in order to effectively utilize them for the design, analysis, and licensing of advanced nuclear systems and experiments. A high learning curve for inexperienced users may deter organizations from incorporating these tools into their internal processes. This project involved development of a plug-in to the Symbolic Nuclear Analysis Package (SNAP) for the System Analysis Module (SAM) tool. SAM is an advanced system analysis tool for reactor transient analyses being developed at Argonne National Laboratory under the U.S. DOE Office of Nuclear Energy’s Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. SAM utilizes an object-oriented application framework (MOOSE), and its underlying meshing and finite-element library (libMesh) and linear and non-linear solvers (PETSc), to leverage modern advanced software environments and numerical methods. SNAP provides a highly flexible framework for creating, modifying and documenting input for engineering analysis codes such as SAM as well as extensive functionality for submitting, monitoring, and interacting with the codes through an intuitive graphical user interface (GUI). The common user interface provided by SNAP minimizes the learning curve for engineers starting with a new analysis code and provides an intuitive framework for transitioning between different analysis codes. SNAP provides a powerful but intuitive interface to facilitate access to advanced modeling and simulation tools for inexperienced users. Unlike many “form based” GUI’s, SNAP maps each engineering code’s component input to an internal database which manages all component input parameters along with component interconnections. This level of abstraction permits SNAP to support several advanced capabilities such as renodalization, model validation and consistency checks, embedded documentation, model notebook generation, data ownership and reviewer tracking, and variable assignment for inputs to name a few. SNAP includes a built-in Python interpreter and is interfaced to several commercial and open source packages including CPython, MATLAB/OCTAVE, Microsoft Office, Open Office, and SANDIA’s DAKOTA package which provides Uncertainty Quantification analysis through the SNAP plug-ins. Phase I of this project involved development a fully functional basic SAM plug-in to SNAP. This plug-in provides the ability to import existing models, graphically construct, edit and submit models using SNAP’s extensive functionality.

99 GENERAL AND MISCELLANEOUS↗

Alabama Department of Environmental Management Plugging and Abandonment Report [Well Name/ID: D9-7]

The D 9-7#2 is a UIC Class V injection well (ADEM permit number ALSI9949664), located in Citronelle Oil Field, Citronelle Alabama. The purpose of the well was to inject CO2 into the upper Paluxy formation in an experiment to investigate the potential underground CO2 storage in a deep saline reservoir. A total of 114,104 metric tonnes of CO2 were injected through the D 9-7#2 between August 20, 2012 and September 1, 2014. A minimum three-year post injection site care period began on September 1, 2014. This report summarizes the permanent plugging and abandonment of the D-9-7#2 well. Following the demonstration of CO2 containment and non-endangerment (ref acknowledgement letter from ADEM dated September 27, 2017), Denbury developed a plugging and abandonment (PA) plan for the well. This plan was approved by the Alabama Oil and Gas Board and complies with Denbury’s environmental, health and safety guidelines. The D-9-7#2 well was spud in December 2011 and was drilled to a total depth of 11,790 ft. Prior to the well plugging operations a cement retainer was set in the well casing at 9,336 feet to isolate the injection zone and a 10-feet cement plug was set at 10,790 feet to isolate the oil reservoir, the ‘Donovan’ formation which lies underneath the Paluxy.

01 COAL, LIGNITE, AND PEAT↗

Wall plug efficiency analysis of a compact SRF industrial accelerator [Poster]

Superconducting radiofrequency cavities offer extremely high (>90%) RF-to-beam energy conversion efficiency. Recent breakthroughs in the Nb 3 Sn SRF cavity technology, successful demonstration of the conduction cooling technique, and the availability of high cooling capacity cryocoolers has made possible the use of SRF for industrial particle accelerators. However, the overall wall plug-to-beam efficiency of such an SRF accelerator can be limited by the wall plug-to-RF power efficiency of the RF source powering this accelerator. The present study quantifies the wall plug-to-beam efficiency of a conduction-cooled SRF accelerator considering several different choices of the RF power source. The study concludes that the wall plug efficiency of the accelerator is indeed limited by that of the power source.

43 PARTICLE ACCELERATORS↗