Search NASA⌕ Search

SEARCH · Search NASA

Results for “PYROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Aerodynamic levitator for in situ x-ray structure measurements on high temperature and molten nuclear fuel materials

An aerodynamic levitator with carbon dioxide laser beam heating was integrated with a hermetically sealed controlled atmosphere chamber and sample handling mechanism. The system enabled containment of radioactive samples and control of the process atmosphere chemistry. The chamber was typically operated at a pressure of approximately 0.9 bars to ensure containment of the materials being processed. Samples 2.5-3 mm in diameter were levitated in flowing gas to achieve containerless conditions. Levitated samples were heated to temperatures of up to 3500 °C with a partially focused carbon dioxide laser beam. Sample temperature was measured using an optical pyrometer. The sample environment was integrated with a high energy (100 keV) x-ray synchrotron beamline to enable in situ structure measurements to be made on levitated samples as they were heated, melted, and supercooled. The system was controlled from outside the x-ray beamline hutch by using a LabVIEW program. Measurements have been made on hot solid and molten uranium dioxide and binary uranium dioxide-zirconium dioxide compositions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heavy Ion Fusion Science Virtual National Laboratory 4th Quarter 2009 Milestone Report: Measure and simulate target temperature and dynamic response in optimized NDCX-I configurations with initial diagnostics suite

This milestone has been met. The effort contains two main components: (1) Experimental results of warm dense matter target experiments on optimized NDCX-I configurations that include measurements of target temperature and transient target behavior. (2) A theoretical model of the target response to beam heating that includes an equilibrium heating model of the target foil and a model for droplet formation in the target for comparison with experimental results. The experiments on ion-beam target heating use a 300-350-keV K{sup +} pulsed beam from the Neutralized Compression Drift Experiment (NDCX-I) accelerator at LBNL. The NDCX-I accelerator delivers an uncompressed pulse beam of several microseconds with a typical power density of >100 kW/cm{sup 2} over a final focus spot size of about 1 mm. An induction bunching module the NDCX-I compresses a portion of the beam pulse to reach a much higher power density over 2 nanoseconds. Under these conditions the free-standing foil targets are rapidly heated to temperatures to over 4000 K. We model the target thermal dynamics using the equation of heat conduction for the temperature T(x,t) as a function of time (t) and spatial dimension along the beam direction (x). The competing cooling processes release energy from the surface of the foil due to evaporation, radiation, and thermionic (Richardson) emission. A description of the experimental configuration of the target chamber and results from initial beam-target experiments are reported in our FY08 4th Quarter and FY09 2nd Quarter Milestone Reports. The WDM target diagnostics include a high-speed multichannel optical pyrometer, optical streak camera, VISAR, and high-speed gated cameras. The fast optical pyrometer is a unique and significant new diagnostic which provides valuable information on the temperature evolution of the heated target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detecting keyhole porosity and monitoring process signatures in additive manufacturing: an in situ pyrometry and ex situ X-ray radiography correlation

Creation of pores and defects during laser powder bed fusion (LPBF) can lead to poor mechanical properties and thus must be minimized. Post-build inspection is required to ensure the printed parts contain acceptably low defect concentrations. These inspections are time consuming and costly, especially for large or complex parts. As a potential solution, in situ process monitoring can be used to detect the creation of defects, characterize local material behavior and predict expected component properties. However, the precise relationship between pore creation and in situ process monitoring still needs to be understood. In this work, high-speed infrared diode-based pyrometry and high-speed optical imaging signals were used to monitor LPBF printing of 446 stainless steel 316 L single tracks with varying laser power and velocity. Results indicate an increase in pyrometer signal and melt pool dimensions with increasing laser power and decreasing velocity in agreement with previous work. In addition, careful analysis of pyrometer signal reveals a distinct signature of the conduction-to-keyhole mode transition which was confirmed by metallography. Critically, pore defect initiation as characterized by ex situ X-ray radiography was correlated with in situ thermal monitoring signals to derive the probability of defect creation. Our results show that, in principle, a probabilistic prediction of pore formation can be achieved based on in situ high-speed pyrometry monitoring of the LPBF melt pool.

36 MATERIALS SCIENCE↗

Experiments and simulations of isochorically heated warm dense carbon foam at the Texas Petawatt Laser

An experimental and simulation study of warm dense carbon foams at ambient density (n e ~10 21 cm –3 ) is presented. This study of isochorically heated foams is motivated by their potential application in carbon-atmosphere white-dwarf envelopes, where there are modeling uncertainties due to the equation of state. The foams are heated on an approximately picosecond time scale with a laser-accelerated proton beam. The cooling and expansion of the heated foams can be modeled with appropriately initialized radiation-hydrodynamics codes; xRAGE code is used in this work. The primary experimental diagnostic is the streaked optical pyrometer, which images a narrow band of radiation from the rear surface of the heated material. Presented are xRAGE modeling results for both solid aluminum targets and carbonized resorcinol-formaldehyde foam targets, showing that the foam appears to cool slowly on the pyrometer because of partial transparency. So that simulations of cooling foam are processed properly, it is necessary to account for finite optical depth in the photosphere calculation, and the methods for performing that calculation are presented in depth.

36 MATERIALS SCIENCE↗

Driving Down HB-LED Costs. Implementation of Process Simulation Tools and Temperature Control Methods of High Yield MOCVD Growth

The overall objective of this multi-faceted program is to develop epitaxial growth systems that meet a goal of 75% (4X) cost reduction in the epitaxy phase of HB-LED manufacture. A 75% reduction in yielded epitaxy cost is necessary in order to achieve the cost goals for widespread penetration of HB-LED's into back-lighting units (BLU) for LCD panels and ultimately for solid-state lighting (SSL). To do this, the program will address significant improvements in overall equipment Cost of Ownership, or CoO. CoO is a model that includes all costs associated with the epitaxy portion of production. These aspects include cost of yield, capital cost, operational costs, and maintenance costs. We divide the program into three phases where later phases will incorporate the gains of prior phases. Phase one activities are enabling technologies. In collaboration with Sandia National Laboratories we develop a Fluent-compatible chemistry predictive model and a set of mid-infrared and near-ultraviolet pyrometer monitoring tools. Where previously the modeling of the reactor dynamics were studied within FLUENT alone, here, FLUENT and Chemkin are integrated into a comprehensive model of fluid dynamics and the most advanced transport equations developed for Chemkin. Specifically, the Chemkin model offered the key reaction terms for gas-phase nucleation, a key consideration in the optimization of the MOCVD process. This new predictive model is used to design new MOCVD reactors with optimized growth conditions and the newly developed pyrometers are used monitor and control the MOCVD process temperature to within 0.5°C run-to-run and within each wafer. This portion of the grant is in collaboration with partners at Sandia National Laboratories. Phase two activities are continuous improvement projects which extend the current reactor platform along the lines of improved operational efficiency, improved systems control for throughput, and carrier modifications for increased yield. Programmatically, improvements made in Phase I are applied to developments of Phase II when applicable. Phase three is the culmination of the individual tasks from both phases one and two applied to proposed production platforms. We selectively combine previously demonstrated tasks and other options to develop a high-volume production-worthy MOCVD system demonstrating >3x throughput, 1.3x capital efficiency, and 0.7x cost of ownership. In a parallel demonstration we validate the concept of an improved, larger deposition system which utilizes the predictive modeling of chemistry-based flow analysis and extensions of the improvements demonstrated on the current platforms. This validation includes the build and testing of a prototype version of the hardware and demonstration of 69% reduction in the cost of ownership. Also, in this phase we present a stand-alone project to develop a high-temperature system which improves source efficiency by 30% while concurrently increasing growth rate by 1.3x. The material quality is held to the same material quality specifications of our existing baseline processes. The merits of other line item tasks in phase three are discussed for inclusion on next-generation platforms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

low-Cost, High-Performance Alternatives for Target Temperature Monitoring Using the Near-Infrared Spectrum

A process is being developed for commercial production of the medical isotope Mo-99 through a photo-nuclear reaction on a Mo-100 target using a highpower electron accelerator. This process requires temperature monitoring of the window through which a high-current electron beam is transmitted to the target. For this purpose, we evaluated two near infrared technologies: the OMEGA Engineering iR2 pyrometer and the Ocean Optics Maya2000 spectrometer with infrared-enhanced charge-coupled device (CCD) sensor. Measuring in the near infrared spectrum, in contrast to the long-wavelength infrared spectrum, offers a few immediate advantages: (1) ordinary glass or quartz optical elements can be used; (2) alignment can be performed without heating the target; and (3) emissivity corrections to temperature are typically less than 10%. If spatial resolution is not required, the infrared pyrometer is attractive because of its accuracy, low cost, and simplicity. If spatial resolution is required, we make recommendations for near-infrared imaging based on our data augmented by calculations

47 OTHER INSTRUMENTATION↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

Ignition phenomena of bulk aluminum alloy as a function of oxygen pressure

An ignition phenomena of 6061 aluminum alloy was investigated as a function of oxygen pressure. Cylindrical aluminum alloy specimens were ignited in a pure oxygen environment by a focused CW CO2 laser beam. The experiments were conducted at oxygen pressures ranging from 0.084 to 2.413 MPa. The temperature history of the entire upper surface of the specimen and of a 0.5 mm diameter spot located initially at the center of the specimen top surface was recorded by using a commercial two-color ratio pyrometer and a fast-response, narrow-band, two-color pyrometer. Mass, brightness, and interior temperatures (for certain experiments) were also recorded throughout the experiment. The results show that the surface temperatures at ignition of the alloy obtained from the temperature curves are below the melting temperature of the aluminum oxide and are slightly dependent on oxygen pressure. The data indicate that the ignition mechanism is complex and probably composed of several phenomena acting both separately and in conjunction with each other.

Nguyen, K.↗

Fast optical pyrometry

Design and operation of accurate millisecond and microsecond resolution optical pyrometers developed at the National Bureau of Standards during the last two decades are described. Results of tests are presented and estimates of uncertainties in temperature measurements are given. Calibration methods are discussed and examples of applications of fast pyrometry are given. Ongoing research in developing fast multiwavelength and spatial scanning pyrometers are summarized.

Cezairliyan, Ared↗

Noncontact temperature pattern measuring device

This invention relates to a noncontact imagine pyrometer system for obtaining the true temperature image of a given substance in a contactless fashion without making assumptions about localized emissivity of the substance or the uniformity of the temperature distribution. Such a contactless temperature imaging system has particular application in the study and production of many materials where the physical contact required to make a conventional temperature measurement drastically effects or contaminates the physical process being observed. Two examples where accurate temperature profiles are of critical interest are: (1) the solid-liquid phase change interface in the production of electronic materials and (2) metastable materials in the undercooling region. The apparent novelty resides in the recognition that an active pyrometer system may be advantageously adapted to perform contactless temperature imaging so that an accurate temperature profile can be obtained.

Elleman, D. D.↗

Non-contact heat flux measurement using a transparent sensor

A working non-contact heat flux sensor was demonstrated using a transparent material (sapphire) and a multiwavelength pyrometer. The pyrometer is used to measure the temperatures of the two surfaces of the sensor from the spectrum of radiation originating from them. The heat conducted through the material is determined from the temperature difference of the two surfaces and the thermal conductivity of the material. The measured heat flux is equal to the incident heat flux within experimental error indicating that no calibration would be necessary. A steady state heat flux of 100 kW/sq m was easily achieved.

Ng, Daniel↗

Correction-free radiometry on specular spheres for containerless processing in microgravity

An analysis is presented that establishes how correction-free radiance measurements or pyrometry can be performed on targets in furnaces where there may be significant additional radiance from heated furnace walls or from reflecting surfaces close to the target. These configurations are common in microgravity and containerless processing applications where a specular target is radiantly heated in a hot-wall furnace, or inductively heated from the fields arising from nearby closely spaced electromagnetic coils. Proper design requires that the pyrometer does not view any images of the background features in the specular target so that stray radiation will not be reflected into the viewing optics of the pyrometer. To analyze the problem, conventional paraxial optics analysis is shown to be significantly in error. Instead a method of nonparaxial ray tracing, based on the derivatives of the ray paths, shows how the images must be located. This leads to analytical results that can be used to design such systems. The findings are applied to the furnace geometries that are presently being considered for flight in LEO.

Thomas, A. S. W.↗

Pyrometric Gas and Surface Temperature Measurements

A multiwavelength pyrometer possessing advantages over the one- and two-wavelength designs is described. Results of its application to surface temperature measurements of ceramics is presented. Also described is a probe suitable for gas temperature measurements to temperatures > 2600 K. The design of the probe includes a multiwavelength pyrometer with fiber optic input.

Fralick, Gustave↗

Broadband IR Measurements for Modis Validation

The primary objective of this research was the development and deployment of autonomous shipboard systems for infrared measurement of ocean surface skin temperature (SST). The focus was on demonstrating long-term, all-weather capability and supplying calibrated skin SST to the MODIS Ocean Science Team (MOCEAN). A secondary objective was to investigate and account for environmental factors that affect in situ measurements of SST for validation of satellite products. We developed and extensively deployed the Calibrated, InfraRed, In situ Measurement System, or CIRIMS, for at-sea validation of satellite-derived SST. The design goals included autonomous operation at sea for up to 6 months and an accuracy of +/- 0.1 C. We used commercially available infrared pyrometers and a precision blackbody housed in a temperature-controlled enclosure. The sensors are calibrated at regular interval using a cylindro-cone target immersed in a temperature-controlled water bath, which allows the calibration points to follow the ocean surface temperature. An upward-looking pyrometer measures sky radiance in order to correct for the non-unity emissivity of water, which can introduce an error of up to 0.5 C. One of the most challenging aspects of the design was protection against the marine environment. A wide range of design strategies to provide accurate, all-weather measurements were investigated. The CIRIMS uses an infrared transparent window to completely protect the sensor and calibration blackbody from the marine environment. In order to evaluate the performance of this approach, the design incorporates the ability to make measurements with and without the window in the optical path.

Jessup, Andrew T.↗

Thermal Conductivity Change Kinetics of Ceramic Thermal Barrier Coatings Determined by the Steady-State Laser Heat Flux Technique

A steady-state laser heat flux technique has been developed at the NASA Glenn Research Center at Lewis Field to obtain critical thermal conductivity data of ceramic thermal barrier coatings under the temperature and thermal gradients that are realistically expected to be encountered in advanced engine systems. In this study, thermal conductivity change kinetics of a plasma-sprayed, 254-mm-thick ZrO2-8 wt % Y2O3 ceramic coating were obtained at high temperatures. During the testing, the temperature gradients across the coating system were carefully measured by the surface and back pyrometers and an embedded miniature thermocouple in the substrate. The actual heat flux passing through the coating system was determined from the metal substrate temperature drop (measured by the embedded miniature thermocouple and the back pyrometer) combined with one-dimensional heat transfer models.

Zhu, Dongming↗

Thermal History Mapping Technology for Turbine Engine Diagnostics

The infusion of ceramic matrix composites (CMCs) in next generation gas turbines represents daunting challenges as the failure of protective coating, known as Environmental Barrier Coating (EBC), means little remnant life of CMC components. Consequently reliable lifing is critical to the success of CMC components. Accurate thermal mapping of EBC in rig and engine test is of paramount importance because temperature is the most critical variable for EBC life. Current temperature measurement technologies include thermocouples, pyrometers, IR cameras, and thermal paints. Thermocouples require a passage to access the components and pyrometers and IR cameras require line-of-sight. Thermal paints are based on color-sensitive pigments that visually indicate the temperature that a component experienced. Thermal paints do not require line-of-sight, however, they have a low resolution and a limited temperature capability (~1400°C). Thermal history coating is based on oxide ceramic which luminesces when excited with a light source. The luminescence changes when the material's structure changes triggered by heat impact. The maximum temperature to which the material was exposed can be determined from the luminescence change. This paper describes the principles of this new technique and demonstrates its capabilities for EBCs exposed to excess of 1500°C.

Lee, Kang N.↗

Development and Validation of MALAMUTE model for Electric Field Assisted Sintering of Structural Materials

Fusion power plant designs feature extreme material performance requirements for structural material candidates. In addition to conventional alloys, more advanced composites and oxide dispersion strengthened (ODS) alloys are being explored, however, achieving the desired microstructures to maximize performance using traditional manufacturing methods can be challenging. The advanced manufacturing (AM) electric field-assisted sintering (EFAS) technique offers improved control over the final microstructure through higher heating and cooling rates and moderate pressures. Modeling and simulation tools show promise in elucidating the process-structure-property-performance (PSPP) correlation for AM-produced parts, including the EFAS process. An inherently multiscale process, the EFAS technique aligns well with the multiscale modeling capability of the open-source Multiphysics Object-Oriented Simulation Environment (MOOSE)[cite]. We present here an electro-thermo-mechanical approach to modeling the EFAS process using the MOOSE Application Library for Advanced Manufacturing UTilitiEs (MALAMUTE) code. Prediction of the field and gradient distributions across the EFAS tooling is required to accurately describe the conditions for the lower-scale microstructural evolution models. In this work we present the MALAMUTE model developed to predict the electrical potential, temperature, and mechanical stress distribution across the EFAS graphite tooling and part at the larger engineering-scale. Validation of the MALAMUTE engineering-scale model is completed using data from experimental densification and pre-densified runs of iron powder via EFAS at 1000oC. These runs were conducted using a Thermal Technology DCS-5 EFAS system. Data collected during the experiment runs include the direct current (DC) supplied to the graphite tooling, the temperature of the graphite tooling as measured with a pyrometer, and the force applied to the top of the graphite tooling stack, and the data were recorded every 10 seconds. Our validation approach used the current and force data from the EFAS run as boundary condition inputs to the MAMALUTE simulation; the temperature data were used to evaluate the MALAMUTE EFAS model prediction. Results of the MALAMUTE simulations are employed to connect the external pyrometer temperature measurement to the temperature profile across the part undergoing consolidation. We investigate the impact of material property variation and mesh deformation on the temperature profile as predicted by MALAMUTE. We conclude by highlighting projects where the MALAMUTE EFAS modeling and simulation capabilities will be used to assist experimental design.

36 - MATERIALS SCIENCE↗

Diffusion of Magnesium in Led Structures with InGaN/GaN Quantum Wells at True Growth Temperatures 860–980°C of p-GaN

The results of an investigation of Mg diffusion in blue LED structures with InGaN/GaN quantum wells are presented for various growth temperatures of the p-GaN layer. The values of the diffusion coefficient estimated for true growth temperatures of 860, 910, and 980°C were 7.5·10{sup –17}, 2.8·10{sup –16}, and 1.2·10{sup –15} cm{sup 2}/s, respectively. The temperature values given in the work were measured on the surface of the growing layer in situ using a pyrometer. The calculated activation energy for the temperature dependence of the diffusion coefficient was 2.8 eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗