Search NASA⌕ Search

SEARCH · Search NASA

Results for “Peak load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

A systematic literature review on residential demand response with a focus on opportunities for low-income communities

Demand Response improves efficiency and grid stability, reducing peak load and total system costs. It can potentially contribute to other societal aspects, including mitigating climate change and improving air quality, health, stress levels, and comfort. This paper reviewed the literature on residential demand response programs in the United States, through the lens of the five energy justice principles, identifying and categorizing a set of 165 papers from 1960 to 2024. As a result, we observe significant progress in distributive justice, however, mostly focused on increasing participation rather than attending specific needs of historically marginalized communities. Concordantly, recognition and procedural justice dimensions are lagging, while cosmopolitan justice studies are scarce, underscoring a need to improve the measurement of impacts resulting from the implementation of demand response programs. Future research opportunities include the consolidation of standardized definitions and metrics, to better understand burdens and needs of diverse residential users. In terms of policy, collection and transparent access to standardized data is required as a condition to the design of flexible, customizable, transparent, and easy to navigate demand response programs. As a result, a better understanding of and engagement with customers has the potential to increase adoption rates, persistence in the program, and overall impacts for the system, households, and society.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Density Thermal Energy Storage by Highly Stable Glauber’s Salt Composites with Low Supercooling for Building-Scale Application

Phase change materials (PCM) are a promising candidate for thermal energy storage in building infrastructure, enabling grid-integrated peak load shaving by utilizing energy production in off-peak hours. Glauber’s salt (Na2SO4.10H2O, Sodium sulfate hydrate) are highly attractive due to their high energy storage capacity and low cost but Glauber’s salt suffers from long-standing challenges including high supercooling ( > 15oC) and low thermal cyclic stability, which is a major setback for practical building-scale energy storage applications. Here, we developed a unique ionic molecular nucleating agent for Glauber’s salt which reduced the supercooling temperature to less than 5oC. By combining this nucleated SSD with a polymer, phase segregation of salt hydrate for over 100 thermal cycles without degradation was achieved. Key was that the polymer confined the SSD crystals, preventing phase separation. In addition, we applied our stable Glauber’s salt composite in a miniatured building model and demonstrate that our PCM composite can be utilized for real-world building infrastructure.

additives↗

Demand Response in Residential Energy Code: Technical Brief

As buildings account for over 75% of U.S. electricity use, effectively managing their loads can greatly facilitate the transition towards a clean, reliable grid. Grid-interactive efficient buildings (GEBs) combine efficiency and demand flexibility with smart technologies and communication to provide occupant comfort and productivity while serving the grid as a distributed energy resource (DER). In turn, GEBs can play a key role in ensuring access to an affordable, reliable, sustainable, and modern U.S. electric power system. Their national adoption could provide $\$$100-200 billion in U.S. electric power system cost savings over the next two decades. The associated reduction in CO 2 emissions is estimated at 6% per year by 2030 (DOE 2021). Building codes represent standard design practice in the construction industry and continually evolve to include advanced technologies and innovative practices. Historically, national model energy codes establish minimum efficiency requirements for new construction (ICC 2020). Expanding codes to support GEB capabilities is a pivotal step towards realizing demand flexibility in support of a clean grid by addressing capabilities to improve interoperability between smart building systems, the grid, and renewable energy resources. Realizing GEBs requires buildings with automated demand response (DR) capabilities that enable standardized communication with or control of, subject to explicit consumer consent, energy smart appliances or home energy management systems. This is achieved through direct or indirect (i.e., via an aggregator) communication between appliances and the electric grid. Energy codes can also support DR communication standardization and advance the deployment of building-integrated DERs such as energy storage, generation, and electric vehicles (EVs). Incorporating automated DR capabilities in energy codes provides many benefits to the consumers. Specifically, it aligns building electric load demand with intermittent renewable energy source availability, decreases peak load on the electric grid, allows buildings to respond to utility price signals, supports electrical network reliability and market growth of products and processes aligned with clean economic growth. The incorporation of DR into the model residential energy codes was considered for both the 2021 and 2024 International Energy Conservation Code (IECC) code development cycles. The approved DR measures in the 2021 cycle were removed in response to appeals (ICC 2020). Updated language was presented for consideration again for the 2024 IECC, where it was negotiated and again approved, and again removed in response to appeals (ICC 2024). This resulted in many sections, including sections on demand responsive controls, being moved to the credits options or an appendix as a voluntary application. This technical brief updates the proposed DR components such that they can be considered by states and local governments for direct incorporation into their codes, as well as for future IECC energy code development. The proposal refinements are intended to support consistency in approach and provide a degree of certainty for building owners, designers, contractors, manufacturers, and building and fire safety professionals. The scope of this technical brief includes three strategies for DR in residential buildings: 1) smart thermostats with demand-responsive control, 2) electric water heating incorporating demand-responsive controls and communication and 3) grid Integrated solar and energy storage systems.

2021 IECC↗

Deformation and damage of composite laminates under impact loading

An analysis was conducted of quasi-isotropic graphite/epoxy plates 8-ply and 16-ply thick clamped around a circumference, subjected to central impact loading. The imparted energy, load history, and transient strains at various locations through the thickness were obtained. The dynamic load history for the thin laminate demonstrates a higher peak load of shorter duration than for the thick laminate, whereas the load record for the thick laminate shows more pronounced fluctuations than for the thin laminate, related to more extensive damage development and flexural oscillations in the former.

Daniel, I. M.↗

Comparison Testing and Analysis of Braided Cords Constructed from Varying Kevlar Fiber Types

Material advancements move quickly, resulting in material obsolescence issues that require parachute engineers to understand how the material properties change with a material upgrade and if there are expected impacts to overall performance of the parachute. The objective of this test was to measure the elongation of different Kevlar types at both the cord-level and at the yarn-level to determine if a change in Kevlar type impacted parachute performance. An Instron machine with a pin-to-pin connection was used to measure load and displacement time histories for various Kevlar cord and yarn samples in a cyclic load profile. Twenty-four cord samples and twenty-four yarn samples were tested; each sample was cycled five times to the relevant maximum load (either to breaking strength or to the 30% peak load expected in flight). In addition to the Instron measurements, a photogrammetric technique was also implemented to measure elongation of the samples using button targets. Modulus test data shows approximately a 10% difference in elongation between Kevlar 29AP and Kevlar 129, and another 10% difference in elongation between Kevlar 29 and Kevlar 29AP. Although this is a measurable change in modulus, the effect on parachute performance is likely small, particularly for non-primary structure elements of relatively small length. This test campaign provides an example of the type of testing and analysis that parachute engineers could do to understand how material upgrades affect performance of their systems.

Parachutes↗

Comparison Testing and Analysis of Braided Cords Constructed from Varying Kevlar Fiber Types

Material advancements move quickly, resulting in material obsolescence issues that require parachute engineers to understand how the material properties change with a material upgrade and if there are expected impacts to overall performance of the parachute. The objective of this test was to measure the elongation of different Kevlar types at both the cord-level and at the yarn-level to determine if a change in Kevlar type impacted parachute performance. An Instron machine with a pin-to-pin connection was used to measure load and displacement time histories for various Kevlar cord and yarn samples in a cyclic load profile. Twenty-four cord samples and twenty-four yarn samples were tested; each sample was cycled five times to the relevant maximum load (either to breaking strength or to the 30% peak load expected in flight). In addition to the Instron measurements, a photogrammetric technique was also implemented to measure elongation of the samples using button targets. Modulus test data shows approximately a 10% difference in elongation between Kevlar 29AP and Kevlar 129, and another 10% difference in elongation between Kevlar 29 and Kevlar 29AP. Although this is a measurable change in modulus, the effect on parachute performance is likely small, particularly for non-primary structure elements of relatively small length. This test campaign provides an example of the type of testing and analysis that parachute engineers could do to understand how material upgrades affect performance of their systems.

Modulus Testing↗

Thermally anisotropic composites for thermal management in building environments

An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.

Shrestha, Som S.↗

Space station common module thermal management: Design and construction of a test bed

In this project, a thermal test bed was designed, simulated, and planned for construction. The thermal system features interior and exterior thermal loads and interfacing with the central-radiator thermal bus. Components of the test bed include body mounted radiator loop with interface heat exchangers (600 Btu/hr); an internal loop with cabin air-conditioning and cold plates (3400 Btu/hr); interface heat exchangers to the central bus (13,000 Btu/hr); and provisions for new technology including advanced radiators, thermal storage, and refrigeration. The apparatus will be mounted in a chamber, heated with lamps, and tested in a vacuum chamber with LN2-cooled walls. Simulation of the test bed was accomplished using a DEC PRO 350 computer and the software package TK! olver. Key input variables were absorbed solar radiation and cold plate loads. The results indicate temperatures on the two loops will be nominal when the radiation and cold plate loads are in the range of 25% to 75% of peak loads. If all loads fall to zero, except the cabin air system which was fixed, the radiator fluid will drop below -100 F and may cause excessive pressure drop. If all loads reach 100%, the cabin air temperature could rise to 96 F.

Barile, R. G.↗

Experimental investigation on phase change material–based finned tube heat exchanger for thermal energy storage and building envelope thermal management

Phase change materials (PCMs) are attractive solutions for thermal energy storage (TES) applications by absorbing and releasing large amounts of latent heat during solid–liquid phase transitions. However, their relatively low thermal conductivity requires novel heat exchanger–based solutions to improve the power density and overall energy storage efficiency of the TES system. This work presents the design and experimental results of a finned tube heat exchanger to store collected natural thermal energy from a building envelope in a latent-based TES and to release it later for building heating/cooling applications. We experimentally evaluate the finned tube heat exchanger and evaluate the performance of TES in reducing building heating and cooling loads over 3–4 h of desired time of operation (e.g., peak load). The optimized design allows for maximum energy density by minimizing the heat exchanger volume, and the system is evaluated experimentally using commercially available heat exchanger materials and an organic PCM. Here, the experimental results reveal that the TES system is able to charge and discharge stored latent energy within 3–4 h, matching peak building electricity demand duration under an average fluid flow rate of 0.136 kg/s and temperature difference of 5.55 °C. Importantly, such optimized designs illuminate a path toward TES designs that are low-cost, scalable, and optimized for thermal energy and power availability under the desired time of operation.

25 ENERGY STORAGE↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Irrigation Modernization Task 4: Accelerating Energy Solutions (FY2022 Final Report)

This report offers insights on energy solutions for irrigation modernization that serve the needs of farmers as well as residents and industry in the local community. Solutions are found in the irrigation districts where local generation from renewable energy sources – solar, hydro, and wind – can be combined with energy storage and customer loads. These combined resources configured in microgrids can lower costs during peak loads and provide resiliency by maintaining electricity supply during outages. The goal of this project, as stated in the FY2022 AOP, is to promote realization of energy solutions that are tailored to physical location, community, infrastructure, and energy value streams. Further, it is to develop examples of how to increase value of, and overcome barriers to, energy solutions in the context of irrigation modernization. In pursuit of that goal, the project looked at options for: 1) Reducing the cost of energy consumed in irrigation systems, 2) Increasing the revenue from surplus power generation, and 3) Deploying new power generation configured as part of a local microgrid. Potential solutions to reducing energy costs and increasing surplus power revenue revolve around addressing regulatory and legal constraints tied to how power is purchased by and sold to the irrigator or irrigation district. Some headway was made in identifying barriers and ways to push utilities to be more accommodating to distributed energy sources; however, for the most part, real progress hinges on changes at the regulatory and legislative level. Deployment of local, renewable generation systems can be implemented provided the economics of the project and the location are favorable. In concert with Famers Conservation Alliance and Energy Trust of Oregon, a number of approaches were studied in the past year, including off-grid solar powered pumps, grid-tied community solar projects, and in-conduit canal hydropower systems. Ultimately three viable projects were identified: 1) North Unit Irrigation District/City of Redmond, Oregon Critical Facility Microgrid – offers combined in-conduit hydro and solar power generation. 2) Wallowa County/Joseph, Oregon Irrigation System Upgrades – centered on upgrades to a non-powered dam that will add a turbine as well as in-conduit power in canal feeders downstream. 3) Medford, Oregon Wastewater Treatment Plant Biogas Cogeneration System – centered on building out biogas storage and grid upgrades to power the plant, sell excess power, and provide emergency backup power (supplanting a diesel generator). Each of these projects has characteristics that broaden the understanding of the value of microgrids employing renewable energy to achieve resiliency and net-zero carbon goals. The first two projects are centered on new hydropower systems. Although the Medford project is only tangentially tied to an irrigation district, it was selected for study analysis as it was the only one mature enough (with sufficient data) to complete an analysis within this project year. Thus, we chose to move forward developing a case study, in concert with the Community Water-Power Resilience project, to demonstrate a method for evaluating such projects. Essentially, this case study serves as a template for studies to be carried out next year that more directly involve irrigation system hydropower, e.g., the project at the Wallowa County/Joseph, Oregon Irrigation System. Lastly, it is recognized that the locations and case studies in this report are all located in Oregon. We recognize this as a limitation. While the intent is not to ignore other states or regions, this result is driven by the fact that we have cultivated a collaboration with non-profit entities in Oregon that focus on these topics – Farmers Conservation Alliance and Energy Trust of Oregon. These partners were central to identifying projects that may be good fits for this program. A goal in the coming year is to establish collaboration with entities in other states/regions that, similarly, can connect us to potential projects in their geographic area. The potential benefits from the WPTO’s support for demonstration projects as energy solutions in irrigation districts include: (1) Alternative power supplies for communities and farms using renewable, carbon-free energy resources, (2) Cost savings for electricity for communities and farms, (3) Resiliency of power supplies for critical loads when electricity from the grid is not available, (4) Resiliency of power supplies for critical infrastructure in the event of catastrophic events, and (5) Demonstration of irrigation modernization projects that provide resilience and a reduced carbon footprint to irrigation districts and nearby communities. These deployments can serve as vanguards/archetypes spurring similar projects in other districts and states.

13 HYDRO ENERGY↗

Scheduling and Control of Flexible Building Loads for Grid Services Based on a Virtual Battery Model

This paper presents a framework for modeling, scheduling, and controlling residential thermostatically controlled loads (TCLs) to provide multiple grid services, such as energy shifting, peak load reduction, and ancillary services. A modeling method is proposed to characterize the aggregate flexibility from heterogeneous TCLs using a battery-equivalent model. Based on the flexibility model, a multi-period optimal scheduling formulation is developed to best utilize the flexibility from building loads and maximize total benefits from stacked value streams. An algorithm is proposed to control individual TCLs to follow the desired power consumption in real-time. The proposed methods are illustrated and validated through simulations.

Wu, Di↗

Factors Influencing Grid-connected Heat Pump Water Heater Performance in the Southeast U.S.

Grid-connected heat pump water heaters (HPWH) can shift electrical load while minimizing impacts to hot water availability for occupants. This capability provides a flexible grid resource to utilities seeking to manage peak loads Such load control also can feasibly improve renewable utilization within the utility electric production mix, for instance using off-peak generation during periods with high renewable energy generation. It also offers lower electric bills to customers through increased energy efficiency of HPWH and cuts greenhouse gas emissions. In particular, the Southeast U.S. due to its high penetration of electric water heating presents a promising opportunity for grid-connected HPWHs. This paper builds upon the results of an extensive HPWH load shifting field study conducted in 51 occupied homes in Florida using EcoPort technology (Butzbaugh et al, 2022). In 2022, only an initial evaluation was available. Here, long term load results are available as well as examination of various control strategies and influences. Analysis is conducted for HPWH energy use and load shifting performance based on home occupancy (i.e., low and high) and water heater location (i.e., conditioned and unconditioned) across different temperature profiles. An unexpected outcome of this analysis was the poor performance of HPWHs located in conditioned spaces, possibly because of inadequate air volume from improper installation. We did find higher demand reductions from 2-hour load ups and slightly improved for critical peak signals in the afternoon control periods. As expected, higher occupancy households showed great load reductions.

Fenaughty, Karen↗

Energy, power, and infrastructure demands from electrifying airport ground support equipment at United States airports

As the airline industry seeks to reduce costs and transition to clean energy, electric ground support equipment is emerging as a favorable option. The integration of electric ground support equipment into airport operations requires careful planning for vehicle deployment, charging infrastructure, and grid impacts. We develop a flexible, bottom-up modeling framework to assess energy and infrastructure needs across more than 300 U.S. airports. Our analysis estimates site-specific power and energy demand, equipment counts by type, charger requirements, and costs. Here we quantify the magnitude of new electrical loads created by the electrification of airport ground support equipment, finding that peak power demand at the largest airports can reach up to 20 megawatts, with annual electricity consumption approaching 51,000 megawatt-hours. We further show that behind-the-meter battery energy storage systems and solar photovoltaic systems can reduce peak load and lower total system costs by as much as 10 million dollars.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The influence of modifications of a fatigue loading history program on fatigue lifetime

Rectangular specimens of 7075 and 2014 aluminum alloys with two holes (stress concentration factor of 3.24) have been tested under axial fatigue loading on a six-rod test bed with modifications of the loading program, the surface particulars, and the frequency. The length of the precrack stage was investigated by use of a new crack detector. In most cases the two alloys behaved similarly, with similar life to crack start under the same loading. Some overloads lengthened the life. Truncation by omission of the lowest peak loads should be limited to about 20 percent of the ultimate load. Simplifying counting methods gave misleading results. Very thin surface layers of anodizing, protection by vinyl, dry nitrogen atmosphere, as well as stepwise reaming or grinding the surface of the holes, lengthened the life; thick anodized layers shortened the life. Compressing the hole surface by rolling had no influence. Frequencies at about 210 to 240 cpm produced shorter lives than those at 40 cpm. At 5.4 cpm the life was considerably longer. A model to better understand the precrack-stage fatigue mechanism is discussed.

Branger, J.↗

Studies of aerothermal loads generated in regions of shock/shock interaction in hypersonic flow

Experimental studies were conducted to examine the aerothermal characteristics of shock/shock/boundary layer interaction regions generated by single and multiple incident shocks. The presented experimental studies were conducted over a Mach number range from 6 to 19 for a range of Reynolds numbers to obtain both laminar and turbulent interaction regions. Detailed heat transfer and pressure measurements were made for a range of interaction types and incident shock strengths over a transverse cylinder, with emphasis on the 3 and 4 type interaction regions. The measurements were compared with the simple Edney, Keyes, and Hains models for a range of interaction configurations and freestream conditions. The complex flowfields and aerothermal loads generated by multiple-shock impingement, while not generating as large peak loads, provide important test cases for code prediction. The detailed heat transfer and pressure measurements proved a good basis for evaluating the accuracy of simple prediction methods and detailed numerical solutions for laminar and transitional regions or shock/shock interactions.

Holden, Michael S.↗

Impacts of Renewable and Storage Technologies on Resource Adequacy

This presentation kicked off the 2020 Austin Electricity Conference, Panel 1: Impacts of Low-Carbon Technologies on Resource Adequacy. This short presentation provided a brief introduction to resource adequacy and then highlighted a few illustrative examples for how increasing penetrations of variable renewable energy and storage is changing how we think about and model resources adequacy. Key themes were how all hours of the year matter (with particular importance on peak net load instead of peak load) and how greater operational detail needs to be included in resource adequacy modeling.

41 EE - Solar Energy Technologies Office (EE-4S)↗