Search NASA⌕ Search

SEARCH · Search NASA

Results for “Plasma Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Plasma dynamics in a discharge produced by a pulsed dual frequency inductively coupled plasma source

Using a Langmuir probe, time resolved measurements of plasma parameters were carried out in a discharge produced by a pulsed dual frequency inductively coupled plasma source. The discharge was sustained in an argon gas environment at a pressure of 10 mTorr. The low frequency (P{sub 2} {sub MHz}) was pulsed at 1 kHz and a duty ratio of 50%, while high frequency (P{sub 13.56} {sub MHz}) was maintained in the CW mode. All measurements were carried out at the center of the discharge and 20 mm above the substrate. The results show that, at a particular condition (P{sub 2} {sub MHz} = 200 W and P{sub 13.56} {sub MHz }= 600 W), plasma density increases with time and stabilizes at up to ∼200 μs after the initiation of P{sub 2} {sub MHz} pulse at a plasma density of (2 × 10{sup 17} m{sup −3}) for the remaining duration of pulse “on.” This stabilization time for plasma density increases with increasing P{sub 2} {sub MHz} and becomes ∼300 μs when P{sub 2} {sub MHz} is 600 W; however, the growth rate of plasma density is almost independent of P{sub 2} {sub MHz}. Interestingly, the plasma density sharply increases as the pulse is switched off and reaches a peak value in ∼10 μs, then decreases for the remaining pulse “off-time.” This phenomenon is thought to be due to the sheath modulation during the transition from “pulse on” to “pulse off” and partly due to RF noise during the transition period. The magnitude of peak plasma density in off time increases with increasing P{sub 2} {sub MHz}. The plasma potential and electron temperature decrease as the pulse develops and shows similar behavior to that of the plasma density when the pulse is switched off.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionisation response in semiconductor structures exposed to the X-ray radiation of a femtosecond laser-plasma source

The possibilities of applying a femtosecond laser-plasma source of X-ray radiation for modelling the effect of single nuclear particles based on the principle of equivalent charge generation are analysed. The parameters of femtosecond X-ray radiation for the experimental modelling of individual radiation effects are validated. The experimental setup forming the X-ray radiation is described. The results of comparative ionisation response modelling in simple electronic devices using the FLUKA and FEANT codes are presented. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma sources for spacecraft neutralization

The principles of the operation of plasma sources for the neutralization of the surface of a spacecraft traveling in the presence of hot plasma are discussed with special attention given to the hollow-cathode-based plasma contactors. Techiques are developed that allow the calculation of the potentials and particle densities in the near environment of a hollow cathode plasma contactor in both the test tank and the LEO environment. The techniques and codes were validated by comparison of calculated and measured results.

Davis, V. A.↗

A plasma source driven predator-prey like mechanism as a potential cause of spiraling intermittencies in linear plasma devices

Three-dimensional global drift fluid simulations are carried out to analyze coherent plasma structures appearing in the NAGDIS-II linear device (nagoya divertor plasma Simulator-II). The numerical simulations reproduce several features of the intermittent spiraling structures observed, for instance, statistical properties, rotation frequency, and the frequency of plasma expulsion. The detailed inspection of the three-dimensional plasma dynamics allows to identify the key mechanism behind the formation of these intermittent events. The resistive coupling between electron pressure and parallel electric field in the plasma source region gives rise to a quasilinear predator-prey like dynamics where the axisymmetric mode represents the prey and the spiraling structure with low azimuthal mode number represents the predator. This interpretation is confirmed by a reduced one-dimensional quasilinear model derived on the basis of the findings in the full three-dimensional simulations. The dominant dynamics reveals certain similarities to the classical Lotka-Volterra cycle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of the electron density and radiative energy losses in a calcium plasma source based on an electron cyclotron resonance discharge

The parameters of a calcium plasma source based on an electron cyclotron resonance (ECR) discharge were calculated. The analysis was performed as applied to an ion cyclotron resonance system designed for separation of calcium isotopes. The plasma electrons in the source were heated by gyrotron microwave radiation in the zone of the inhomogeneous magnetic field. It was assumed that, in such a combined trap, the energy of the extraordinary microwave propagating from the high-field side was initially transferred to a small group of resonance electrons. As a result, two electron components with different transverse temperatures-the hot resonance component and the cold nonresonance component-were created in the plasma. The longitudinal temperatures of both components were assumed to be equal. The entire discharge space was divided into a narrow ECR zone, where resonance electrons acquired transverse energy, and the region of the discharge itself, where the gas was ionized. The transverse energy of resonance electrons was calculated by solving the equations for electron motion in an inhomogeneous magnetic field. Using the law of energy conservation and the balance condition for the number of hot electrons entering the discharge zone and cooled due to ionization and elastic collisions, the density of hot electrons was estimated and the dependence of the longitudinal temperature T{sub e Parallel-To} of the main (cold) electron component on the energy fraction {beta} lost for radiation was obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Negative ion production in the RF multiaperture surface-plasma source

The experiments on negative hydrogen ion beam production in a multi-aperture long-pulse surface-plasma source are described. H- ions are produced on the surface of a plasma grid covered by cesium and illuminated by fast plasma particles. The source uses a radio-frequency driver to generate plasma. A composite magnet system made of external permanent magnets confines and filters electrons in the plasma region, and deflects them in the extraction area. A multiaperture, multi-electrode ion optical system is used for beam formation. The electrode heating and cooling during long pulses is accomplished by circulating a heat transfer fluid through channels drilled in the electrodes bodies. H- ions extraction through a single aperture and 21 apertures was performed and studied. A stable H- beam with the current up to 0.7 A, energy up to 74 kV, and pulse duration up to 7 s was routinely obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Surface Plasma Source Electrode Activation by Surface Impurities

In experiments with RF saddle antenna surface plasma sources (SPS), the efficiency of H{sup -} ion generation was increased by up to a factor of 5 by plasma electrode 'activation', without supplying additional Cs, by heating the collar to high temperature for several hours using hot air flow and plasma discharge. Without cracking or heating the cesium ampoule, but likely with Cs recovery from impurities, the achieved energy efficiency was comparable to that of conventionally cesiated SNS RF sources with an external or internal Cs supply. In the experiments, optimum cesiation was produced (without additional Cs) by the collection and trapping of traces of remnant cesium compounds from SPS surfaces. Such activation by accumulation of impurities on electrode surfaces can be a reason for H{sup -} emission enhancement in other so-called 'volume' negative ion sources.

43 PARTICLE ACCELERATORS↗

Femtosecond-Laser-Driven Cluster-Based Plasma Source for High-Resolution Ionography

The intense isotropic source of multicharged ions, with energy above 300 keV, was produced by femtosecond Ti:Sa laser pulses irradiation (intensity of approx4x10{sup 17} W/cm{sup 2}) of the He and CO{sub 2} gases mixture expanded in supersonic jet. High contrast ionography images have been obtained for 2000 dpi metal mesh, 1 mum polypropylene and 100 nm Zr foils, as well as for different biological objects. Images were recorded on 1 mm thick CR-39 ion detector placed in contact with back surface of the imaged samples, at the distances 140-160 mm from the plasma source. The obtained spatial resolution of the image was approx600 nm. A 100 nm object thickness difference was resolved very well for both Zr and polymer foils. The multicharged ion energy for Carbon and Oxygen ions passing through the 1 mum polypropylene foil is estimated to give the energy of more than 300 keV. An almost equal number of ions were measured with total number of about 10{sup 8} per shot at a different direction from plasma source. Easy production of different sub-MeV ions in wide space angle, recognizes femtosecond-laser-driven-cluster-based plasma as a well-suited bright source for novel type of submicron ionography to image different media, including nanofoils, membranes, and other low-contrast objects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coaxial microwave plasma source

Physical principles underlying the operation of a pulsed coaxial microwave plasma source (micro-wave plasmatron) are considered. The design and parameters of the device are described, and results of experimental studies of the characteristics of the generated plasma are presented. The possibility of application of this type of plasmatron in gas-discharge physics is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transformer coupled toroidal wave-heated remote plasma sources operating in Ar/NF 3 mixtures

Remote plasmas are used in semiconductor device manufacturing as sources of radicals for chamber cleaning and isotropic etching. In these applications, large fluxes of neutral radicals (e.g. F, O, Cl, H) are desired with there being negligible fluxes of potentially damaging ions and photons. One remote plasma source (RPS) design employs toroidal, transformer coupling using ferrite cores to dissociate high flows of moderately high pressure (up to several Torr) electronegative gases. In this paper, results are discussed from a computational investigation of moderate pressure, toroidal transformer coupled RPS sustained in Ar and Ar/NF 3 mixtures. Operation of the RPS in 1 Torr (133 Pa) of argon with a power of 1.0 kW at 0.5 MHz and a single core produces a continuous toroidal plasma loop with current continuity being maintained dominantly by conduction current. Operation with dual cores introduces azimuthal asymmetries with local maxima in plasma density. Current continuity is maintained by a mix of conduction and displacement current. Operation in NF 3 for the same conditions produces essentially complete NF 3 dissociation. Electron depletion as a result of dissociative attachment of NF 3 and NF x fragments significantly alters the discharge topology, confining the electron density to the downstream portion of the source where the NFx density has been lowered by this dissociation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A double-plasma source of continuous bipolar ion-ion beam

A double-plasma source capable of the generation of a continuous bipolar ion-ion beam is described. The quasi-neutral ion-ion flow to an extraction electrode is formed in the system containing primary inductively coupled plasma separated from a secondary plasma by an electrostatic grid-type filter. The total current of each ion species to the 250 mm diameter extraction electrode is about 80 mA; the electron current does not exceed 30% of the ion current. Method of positive/negative ion current ratio control is proposed, allowing the ion currents ratio variation in wide range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discharge Characteristics of the Penning Plasma Source

The results of investigation of discharge characteristics of the Penning plasma source are presented. Volt-ampere characteristics (VAC), energy distribution, and mass-charge composition of ions emitted from the discharge under different modes of its combustion were measured. The connection between the discharge current bursts and increase in the potential drop (up to 50% of the anode voltage) is established. The measured VACs agree well with the theoretical dependencies. It is shown that the content of atomic hydrogen ions increases from 5 to 10% with an increase in the anode voltage from 1 to 3.5 kV and the power applied in the discharge (from 0.2 to 3 W).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Waveguide slot-excited long racetrack electron cyclotron resonance plasma source for roll-to-roll (scanning) processing

We present a SLot-excited ANtenna (SLAN) long racetrack ECR plasma source that is utilized for roll-to-roll plasma processing such as thin film encapsulation of large-area OLED (organic light emitting diode) panel or modification of fabric surfaces. This source is designed to be long, and to operate under high density uniform plasma with sub-milli-torr pressures. The above features are accomplished by a slot-excited long racetrack resonator with a toroidal geometry of magnetic field ECR configuration, and reinforced microwave electric distributions along the central region of plasma chamber. Also, a new feature has been added to the source. This is to employ a tail plunger, which allows the microwave electric field and the uniformity of the plasma profile to be easily adjustable. We have successfully generated Ar plasmas operating with the microwave power of 0.5–3 kW in the pressure range of 0.2–10 mTorr. The plasma is uniform (<10%) in the direction of the straight track and has a Gaussian profile in the roll-to-roll (scanning) direction. In addition, it is shown that the tail plunger could adjust the plasma profile in order to obtain plasma uniformity. Furthermore, based on the results, we suggest a newly designed up-scaled racetrack-SLAN source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchronization between two coupled direct current glow discharge plasma sources

Experimental results on the nonlinear dynamics of two coupled glow discharge plasma sources are presented. A variety of nonlinear phenomena including frequency synchronization and frequency pulling are observed as the coupling strength is varied. Numerical solutions of a model representation of the experiment consisting of two coupled asymmetric Van der Pol type equations are found to be in good agreement with the observed results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large area plasma source

An all permanent magnet Electron Cyclotron Resonance, large diameter (e.g., 40 cm) plasma source suitable for ion/plasma processing or electric propulsion, is capable of producing uniform ion current densities at its exit plane at very low power (e.g., below 200 W), and is electrodeless to avoid sputtering or contamination issues. Microwave input power is efficiently coupled with an ionizing gas without using a dielectric microwave window and without developing a throat plasma by providing a ferromagnetic cylindrical chamber wall with a conical end narrowing to an axial entrance hole for microwaves supplied on-axis from an open-ended waveguide. Permanent magnet rings are attached inside the wall with alternating polarities against the wall. An entrance magnet ring surrounding the entrance hole has a ferromagnetic pole piece that extends into the chamber from the entrance hole to a continuing second face that extends radially across an inner pole of the entrance magnet ring.

Foster, John↗

Electron cyclotron resonance ion source plasma chamber studies using a network analyzer as a loaded cavity probe

A method and first results utilizing a network analyzer as a loaded cavity probe to study the resonance properties of a plasma filled electron cyclotron resonance ion source (ECRIS) plasma chamber are presented. The loaded cavity measurements have been performed using a dual port technique, in which two separate waveguides were used simultaneously. One port was used to ignite and sustain the plasma with a microwave source operating around 11 GHz and the other was used to probe the cavity properties with the network analyzer using a frequency range around 14 GHz. The first results obtained with the JYFL 14 GHz ECRIS demonstrate that the presence of plasma has significant effects on the resonance properties of the cavity. With plasma the frequency dependent behavior is strongly damped and this trend strengthens with increasing microwave power.

43 PARTICLE ACCELERATORS↗

Normalization schemes for ultrafast x-ray diffraction using a table-top laser-driven plasma source

We present an experimental setup of a laser-driven x-ray plasma source for femtosecond x-ray diffraction. Different normalization schemes accounting for x-ray source intensity fluctuations are discussed in detail. We apply these schemes to measure the temporal evolution of Bragg peak intensities of perovskite superlattices after ultrafast laser excitation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗