Search NASA⌕ Search

SEARCH · Search NASA

Results for “Polymer solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Additive Manufacturing of Poly(phenylene Sulfide) Aerogels via Simultaneous Material Extrusion and Thermally Induced Phase Separation

Abstract Additive manufacturing (AM) of aerogels increases the achievable geometric complexity, and affords fabrication of hierarchically porous structures. In this work, a custom heated material extrusion (MEX) device prints aerogels of poly(phenylene sulfide) (PPS), an engineering thermoplastic, via in situ thermally induced phase separation (TIPS). First, pre‐prepared solid gel inks are dissolved at high temperatures in the heated extruder barrel to form a homogeneous polymer solution. Solutions are then extruded onto a room‐temperature substrate, where printed roads maintain their bead shape and rapidly solidify via TIPS, thus enabling layer‐wise MEX AM. Printed gels are converted to aerogels via postprocessing solvent exchange and freeze‐drying. This work explores the effect of ink composition on printed aerogel morphology and thermomechanical properties. Scanning electron microscopy micrographs reveal complex hierarchical microstructures that are compositionally dependent. Printed aerogels demonstrate tailorable porosities (50.0–74.8%) and densities (0.345–0.684 g cm −3 ), which align well with cast aerogel analogs. Differential scanning calorimetry thermograms indicate printed aerogels are highly crystalline (≈43%), suggesting that printing does not inhibit the solidification process occurring during TIPS (polymer crystallization). Uniaxial compression testing reveals that compositionally dependent microstructure governs aerogel mechanical behavior, with compressive moduli ranging from 33.0 to 106.5 MPa.

Chemistry↗

Bottlebrush Polymers at Liquid Interfaces: Assembly Dynamics, Mechanical Properties, and All-Liquid Printed Constructs

Bottlebrush polymer surfactants (BPSs), formed by the interfacial interactions between bottlebrush polymers (BPs) with poly(acrylic acid) side chains dissolved in an aqueous phase and amine-functionalized ligands dissolved in the oil phase, assemble and bind strongly to the fluid-fluid interface. The ratio between N BB (backbone degree of polymerization) and N SC (side chain degree of polymerization) defines the initial assembly kinetics, interface packing efficiency, and stress relaxation. The equilibrium interfacial tension (γ) increases when N BB < N SC , but decreases when N BB $\gg$ N SC , correlating to a pronounced change in the effective shape of the BPs from being spherical to worm-like structures. The apparent surface coverage (ASC), i.e., the interfacial packing efficiency, decreases as N BB increases. The dripping-to-jetting transition of an injected polymer solution, as well as fluorescence recovery after photobleaching experiments, revealed faster initial assembly kinetics for BPs with higher N BB . Furhter, Euler buckling of BPS assemblies with different N BB values was used to characterize the stress relaxation behavior and bending modulus. The stress relaxation behavior was directly related to the ASC, reflecting the strong influence of macromolecular shape on packing efficiency. The bending modulus of BPSs decreases for N BB < N SC , but increased when N BB $\gg$ N SC , showing the effect of molecular architecture and multisite anchoring. All-liquid printed constructs with lower N BB BPs yielded more stable structured liquids, underscoring the importance of macromolecular packing efficiency at fluid interfaces. Overall, this work elucidates fundamental relationships between nanoscopic structures and macroscopic properties associated with various bottlebrush polymer architectures, which translate to the stabilization of all-fluidic printed constructs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linear Reciprocating Tribometer for In Situ Neutron Reflectometry of Soft Matter

Neutron reflectometry is a technique for measuring structure near planar interfaces that has been previously used to non-destructively characterize the polymer density of hydrated, dilute, and soft materials. Previous investigations have conducted neutron reflectometry measurements of liquids, gels, emulsion, and polymer solutions at rest, in compression, and subject to shear stress. However, correlating structure with tribological properties of soft materials presents significant experimental challenges for prior instruments due to wall slip, sample thickness, and structural heterogeneity (e.g., depth-wise gradients). A linear reciprocating tribometer offers several advantages for in situ neutron reflectometry studies, including uniform velocity profiles, constant shear stress over large regions of interest, and independent control of normal force and sliding velocity during measurements. This work outlines basic considerations for the design of a custom linear reciprocating tribometer that operates in a neutron beamline and includes commissioning measurements. The tribometer is designed to compress soft and hydrated materials against linearly reciprocating silicon disks. The three key design considerations for this tribometer are (1) safety, (2) neutron transmission, and (3) sample positioning. This instrument design will enable in situ studies of soft matter and illuminate the role of interfacial structure on tribological phenomena.

42 ENGINEERING↗

Polyhalohydrins: Investigating Vicinal Functionalities by Ring-Opening of Epoxides on Polyolefins

Halohydrins are functional groups that are underexplored in polymer science. This study synthesized and examined structure–property relationships of halohydrin-functionalized polymers derived from polycyclooctene (PCOE), which was obtained via ring-opening metathesis polymerization (ROMP). The polyhalohydrins, including polychlorohydrin, polybromohydrin, and polyiodohydrin, were produced through a two-step process involving epoxidation of PCOE followed by epoxide ring-opening using hydrochloric, hydrobromic, or hydroiodic acid. These stereoirregular and regioirregular polymers are amorphous as measured by differential scanning calorimetry and X-ray scattering. Lap joint shear testing revealed an enhanced adhesive performance in polychlorohydrin and polybromohydrin, with the former demonstrating nearly three times the ultimate shear stress compared to a model polyethylene, hydrogenated PCOE. Additionally, contact angle measurements and surface free energy analysis showed an increase in hydrophilicity and polarity from iodine- to bromine- to chlorine-functionalized polyhalohydrins, aligning with trends in adhesion strength. Furthermore, these results underscore the potential of halohydrin functionalization as a versatile approach for tuning surface properties, offering new opportunities for polymer-to-polymer transformations.

Functional groups↗

Adverse Effect of Polyelectrolyte Complexation on the CO 2 Permeability of Polyvinylamine Copolymers

Polyvinylamine (PVAm) is one of the most studied polymers for facilitated transport membranes (FTMs) in CO 2 separation applications. In this study, poly(N-vinylformamide) (PNVf) was hydrolyzed to prepare a range of PNVf-PVAm copolymer compositions and the effect of PVAm fraction on CO 2 permeability and CO 2 /N 2 selectivity these polymers examined. The most permeable film was the polymer containing 52 mol% PVAm units with a CO 2 permeability of 353 Barrer and CO 2 /N 2 selectivity of 96, when tested at 60°C with humidified 14/86 CO 2 /N 2 mixed gas. Despite containing a higher loading of amines to act as CO 2 carriers, higher PVAm contents yielded significantly lower CO 2 permeability, without a loss of selectivity. This trend was not due to polymer crystallization since none of the PVAm films exhibited crystallinity in X-ray diffraction analysis. The loss of gas permeability at high PVAm content was instead due to strong polyelectrolyte interactions between polymer chains formed when PVAm reacts with CO 2 . Since only the PVAm units are ionized upon reaction with CO 2 , with the PNVf units remaining neutral, the density of these ionic effects increased as PVAm content increased, leading to increased resistance to gas permeation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stress-controlled medium-amplitude oscillatory shear (MAOStress) of PVA–Borax

We report the first-ever complete measurement of MAOStress material functions, which reveal that stress can be more fundamental than strain or strain rate for understanding linearity limits as a function of Deborah number. The material used is a canonical viscoelastic liquid with a single dominant relaxation time: polyvinyl alcohol (PVA) polymer solution cross-linked with tetrahydroborate (Borax) solution. We outline experimental limit lines and their dependence on geometry and test conditions. These MAOStress measurements enable us to observe the frequency dependence of the weakly nonlinear deviation as a function of stress amplitude. The observed features of MAOStress material functions are distinctly simpler than MAOStrain, where the frequency dependence is much more dramatic. The strain-stiffening transient network model was used to derive a model-informed normalization of the nonlinear material functions that accounts for their scaling with linear material properties. Moreover, we compare the frequency dependence of the critical stress, strain, and strain-rate for the linearity limit, which are rigorously computed from the MAOStress and MAOStrain material functions. While critical strain and strain-rate change by orders of magnitude throughout the Deborah number range, critical stress changes by a factor of about 2, showing that stress is a more fundamental measure of nonlinearity strength. This work extends the experimental accessibility of the weakly nonlinear regime to stress-controlled instruments and deformations, which reveal material physics beyond linear viscoelasticity but at conditions that are accessible to theory and detailed simulation.

Mechanics↗

CO 2 -Responsive Fracturing Fluids for Enhanced Geothermal Systems (Final Report)

Our group has recently developed StimuFrac, a non-toxic stimuli-responsive fracturing fluid consisting of a CO 2 -reactive polymer which has shown at the lab-scale to consistently fracture rock cores at significantly lower net pressures in a range of representative geothermal pressure/temperature conditions. However, until now the mechanism/s responsible for more effective fracturing, of critical importance to optimize fracturing performance as well as strategize injection methodologies for field deployment, was not understood. In this document, we report (1) on the two main mechanisms responsible for fracturing rock at lower net pressures with StimuFrac; (2) the phase behavior of StimuFrac/CO 2 under geothermal wellbore conditions; and (3) based on high-temperature true triaxial stimulations, detailed evidence that StimuFrac/CO 2 is the best performing stimulation fluid under EGS T/P conditions as compared to water, waterless CO 2 , and CO 2 /water fracturing fluids. This is because i) it requires significantly lower volumes of CO 2 due to its reduced leak off into the formation by the crosslinked polymer solution; ii) large fractures can be generated reproducibly at both low and high CO 2 injection flow rates, and iii) the reversible (previously reported) viscosity increase of StimuFrac could be beneficial to transport proppants when they become available for EGS. These results were particularly evident for hot nearly dry rock as well as partially and nearly fully water-saturated granitic rock. GTO requires StimuFrac to be evaluated in fully water-saturated rock to determine whether the above-described performance applies under these conditions. Since (1) GTO considers there is no enough evidence for Sa different StimuFrac formulation to work below 90C (where full water-saturation in an open system is possible) and (2) no polyaxial loading frame larger than a few centimeters that can do hydraulic fracturing tests while maintaining the rock sample fully saturated with water at 200 C exists; PNNL concludes that the only way to determine if StimuFrac represents an advanced fracturing fluid alternative for EGS, is to perform a stimulation in an actual EGS reservoir.

15 GEOTHERMAL ENERGY↗

Hydrodynamic stability of viscoelastic fluids - Importance of fluid model, overstability, and form of disturbance.

A linearized stability analysis has been applied to a fluid flowing in a gravity field between horizontal planes in Couette flow under conditions such that the temperature of the bottom plane exceeds that of the top. It is shown that, under conditions likely to be encountered with polymer solutions, oscillatory instabilities will not be controlling. Criteria are offered for ascertaining when an analysis based upon a second-order fluid model may be expected to yield physically meaningful results. It is also shown that, for the fluid model considered, critical conditions for stability are not changed when disturbances which vary in the flow direction are substituted for those which are a function of the coordinate transverse to the flow.

Mcintire, L. V.↗

Finite amplitude dynamic motion of viscoelastic materials.

It is shown that an integral constitutive relation containing a memory function depending on strain tensor invariants can describe the rheological behavior of finite amplitude oscillatory motion of polymer solutions both qualitatively and quantitatively. Values of the material constants are obtained by a numerical technique of simultaneously curve fitting simple shearing viscosity, first normal stress difference, and small amplitude oscillatory motion data.

Yen, H.-C.↗

Effects of viscoelasticity on cavitation in drag reducing fluids

To study cavitation inception in polymer solutions, a blow-down water tunnel with short running times was used. Tests were made using 1/4 and 1/2 inch diameter models of hemispherical-nose cylinders. To accurately detect the inception of cavitation, a reliable technique was developed using a continuously operating He-Ne gas laser. The laser beam was adjusted to grazing incidence with the model at the minimum pressure point where cavitation inception was to be expected. A sensitive photocell was placed at ninety degrees to detect the beam. As incipient cavitation occurred, the bubbles caused scattering of the laser beam which was picked up by the photocell. Static pressure near the model in the working section of the tunnel was measured using a solid-state pressure pick-up. The signals from the photocell and the pressure pick-up were recorded on an oscillograph. Velocity field visualization was achieved using one microsecond duration light pulses scattered by small polystryrene latex spheres in the flow.

Ting, R. Y.↗

Non-Newtonian effects on flow-generated cavitation and on cavitation in a pressure field

Observations are presented which show that the stresses in a flow field of very dilute polymer are not well enough described by the Navier-Stokes equations to accurately predict cavitation. The contitutive equation for the particular polymer and concentration used is needed. The second-order fluid form in which accelerations are relatively important appears capable of explaining observed cavitation suppression by changing the pressure field due to flow. Bubble dynamics in stationary dilute polymer solutions are also examined and found to be little different from those in water.

Ellis, A. T.↗

Infrared emission spectra from operating elastohydrodynamic sliding contacts

Infrared emission spectra from an operating EHD sliding contact were obtained through a diamond window for an aromatic polymer solute present in equal concentration in four different fluids. Three different temperature ranges, three different loads, and three different speeds for every load were examined. Very sensitive Fourier spectrophotometric (Interferometric) techniques were employed. Band Intensities and band intensity ratios found to depend both on the operating parameters and on the fluid. Fluid film and metal surface temperatures were calculated from the spectra and their dependence on the mechanical parameters plotted. The difference between these temperatures could be plotted against shear rate on one curve for all fluids. However, at the same shear rate the difference between bulk fluid temperature and diamond window temperature was much higher for one of the fluids, a traction fluid, than for the others.

Lauer, J. L.↗

Relating viscosity to polymer concentration

Equation developed by VanDijk and first applied to viscosity of Newtonian suspension of rigid particles by Eilers is rearranged to yield intrinsic viscosity as explicit function of polymer concentration in polymer solvent system. Experiments have shown relationship valid for polymer solutions having relative viscosities ranging from 1 to 100.

Fedors, R. F.↗