Statistical Characterization of Environmental Error Sources Affecting Electronically Scanned Pressure Transducers

Minimization of uncertainty is essential to extend the usable range of the 15-psid Electronically Scanned Pressure [ESP) transducer measurements to the low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources inducing much of this uncertainty requires a well defined and controlled calibration method. Employing such a controlled calibration system, several studies were conducted that provide quantitative information detailing the required controls needed to minimize environmental and human induced error sources. Results of temperature, environmental pressure, over-pressurization, and set point randomization studies for the 15-psid transducers are presented along with a comparison of two regression methods using data acquired with both 0.36-psid and 15-psid transducers. Together these results provide insight into procedural and environmental controls required for long term high-accuracy pressure measurements near 0.01 psia in the hypersonic testing environment using 15-psid ESP transducers.

Green, Del L.↗

Lunar Advanced Volatile Analysis Subsystem: Pressure Transducer Trade Study

In Situ Resource Utilization (ISRU) is a key factor in paving the way for the future of human space exploration. The ability to harvest resources on foreign astronomical objects to produce consumables and propellant offers potential reduction in mission cost and risk. Through previous missions, the existence of water ice at the poles of the moon has been identified, however the feasibility of water extraction for resources remains unanswered. The Resource Prospector (RP) mission is currently in development to provide ground truth, and will enable us to characterize the distribution of water at one of the lunar poles. Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) is the primary payload on RP that will be used in conjunction with a rover. RESOLVE contains multiple instruments for systematically identifying the presence of water. The main process involves the use of two systems within RESOLVE: the Oxygen Volatile Extraction Node (OVEN) and Lunar Advanced Volatile Analysis (LAVA). Within the LAVA subsystem, there are multiple calculations that depend on accurate pressure readings. One of the most important instances where pressure transducers (PT) are used is for calculating the number of moles in a gas transfer from the OVEN subsystem. As a critical component of the main process, a mixture of custom and commercial off the shelf (COTS) PTs are currently being tested in the expected operating environment to eventually down select an option for integrated testing in the LAVA engineering test unit (ETU).

Kang, Edward Shinuk↗

Acceleration-compensated pressure transducer has fast response

Flush-diaphragm transducer accurately measures small dynamic pressures when it is subjected to high accelerations and severe temperature environments. The transducer uses piezoelectric crystals for measuring the pressure and balancing out acceleration forces.

Source record↗

Response of a piezoelectric pressure transducer to IR laser beam impingement

The non-pressure response of a PCB Model 113A transducer to a far infrared radiation impulse from a carbon dioxide laser was investigated. Incident radiation was applied both to the bare transducer diaphragm and to coated diaphragms. Coatings included two common ablative materials and a reflective gold coating. High-flux radiation impulses induced an immediate brief negative output followed by a longer-duration positive output. Both timing and amplitude of the responses will be discussed, and the effects of coatings will be compared. Bursts of blackbody radiation from a 1500 K source produced qualitatively similar responses.

Smith, William C.↗

Measurement and Control of the Variability of Scanning Pressure Transducer Measurements

This paper describes the new wall pressure measurement system and data-quality monitoring software installed at 14x22 Ft subsonic tunnel at the NASA Langley Research Center. The monitoring software was developed to enable measurement and control of the variability of the reference pressures and approximately 400 tunnel wall pressure measurements. Variability of the system, based upon data acquired over a year of wind tunnel tests and calibrations, is presented. The level of variation of the wall pressure measurements is shown to be predictable.

Kuhl, David D.↗

Reliable, Low Mass, Non-Invasive Pressure Transducers

Mass is a major driver for future spacecraft and missions exposed to high radiation levels (i.e. Europa Orbiter) present even more challenge. A variety of non-invasive measurement techniques are in development that enables determination of pressures within a propulsion network.

low mass non-invasive pressure transducers radiati↗

High-sampling-rate pressure transducer has in situ calibration

High-data-rate pressure sensor module can be calibrated after it is attached to an experimental setup. Electrically multiplexed sensor is designed for use in wind-tunnels and other applications requiring accurate measurement of many pressures in a short period of time.

Gross, C.↗

A high-temperature wideband pressure transducer

A condenser microphone AM carrier system, which has been developed to measure pressure fluctuations at elevated temperatures, consists of the following components: a condenser microphone designed for operation at elevated temperatures; existing carrier electronics developed under two previous research grants but adapted to meet present requirements; a 6 m cable operating as a half-wavelength transmission line between the microphone and carrier electronics; and a voltage-controlled oscillator used in a feedback loop for automatic tuning control. Both theoretical and practical aspects of the development program are considered. The three predominant effects of temperature changes are changes in the membrane-backplate gap, membrane tension, and air viscosity. The microphone is designed so that changes in gap and membrane tension tend to have compensating effects upon the microphone sensitivity.

Zuckerwar, A. J.↗

Trielectrode capacitive pressure transducer

Capacitive transducer eliminates adverse effects of temperature and humidity; it is especially suited for measuring pressure changes in high-temperature environment. Transducer basically is three-electrode device.

Coon, G. W.↗

Electronically scanned multichannel pressure transducer system for cryogenic environments

Research into the application of custom doped piezoresistive silicon pressure sensors has led to a multichannel pressure sensor design that will operate accurately and reliably at cryogenic temperatures. The thermal effects upon multichannel pressure sensors are mapped by thermal calibrations and are represented by sets of nth order coefficients specific to each sensor. The thermal offset and sensitivity variations are corrected by computer algorithms which scan the sensors, recall correction coefficients from thermally induced sensor variations, and apply these to correct the sensor's output measurement uncertainty to within 0.5 percent of full scale output for combined offset and sensitivity. A prototype sensor system has been fabricated, and performance test data are presented.

Chapman, John J.↗

An advanced solid state pressure transducer for high reliability SSME application

New methods to advance the state-of-the-art of pressure sensors for the Space Shuttle Main Engine were demonstrated. The results of the feasibility and breadboard demonstration phase and the current status of the research development prototype follow-on phase are presented. A technology breakthrough utilizing silicon piezoresistive technology was achieved in the first phase. A transducer design concept for the SSME application utilizes packaging materials with similar thermal coefficients of expansion and maintains the transducer seals primarily in compression. The silicon chip design will provide dual sensing outputs with laser trimmable integrated compensating electronics. The silicon resistor ion implant dose was customized for the SSME temperature requirement. A basic acoustic modeling software program was developed to evaluate the frequency response characteristics for the package design.

Johnson, R. L.↗

Test and development of inflatable spheres instrumented with miniaturized thermistors, accelerometers and pressure transducers

Instrumentation was developed for the high altitude inflatable sphere to measure its skin temperature, acceleration and internal pressure. The sphere without instrumentation has routinely been used over the past 10 years to provide measurements of winds, density, temperature and pressure between 100 Km and 30 Km altitude. With the miniaturized instrumentation package onboard, the system offers the potential for providing meteorological information as well as a better understanding of sphere performance and dynamics during its descent. Of the six launches of instrumented spheres only one provided telemetry data. However, many of the objectives of the program were achieved.

Luers, J. K.↗

Improved gas-pressure transducer

Optically-selective, acoustically-resonant, gas-detecting device is used to measure intensity of radiation-induced pressure variations. Use of diaphragm improves sensitivity and immunity to background noise.

Dimeff, J.↗