Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Owner”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Moving Beyond Data Paralysis to Effective use of Building Analytics

As digital controls and smart meters become commonplace in commercial buildings, facilities teams have access to overwhelming amounts of data. This data does not typically lead to insights and corrective actions unless it is analyzed and prioritized in automated ways. Analytic software has been commercially available for over 20 years, but only recently have these tools seen increased adoption. This monitoring infrastructure helps uncover hidden operational opportunities, which is enticing for decision makers looking for short paybacks. Rather than single project savings, monitoring-based commissioning (MBCx) provides tools and processes to implement persistent, continuous improvement. What was formerly a data onslaught is now becoming a controlled resource for improved energy management. In 2016, a Research and Industry Partnership program was launched to support the use of analytics and diagnostics technologies and MBCx practices. This program couples technical assistance to owners to help increase adoption with a data collection effort to inform industry. It includes the most comprehensive data available nationally on analytics installation and use. The first-year results are in, with data from 46 organizations representing over 185 million square feet and 2,300 buildings. These organizations have achieved a median year-over-year energy savings of $0.20/sq ft with a median first year technology implementation cost of $0.12/sq ft. The paper summarizes attributes of successful analytics and MBCx installations, and cost-effectiveness results. The research provides insight for utilities considering adopting analytics technologies into incentive programs, for analytics developers to improve the performance of their solutions, and for commercial building facility staff considering these technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Front-End Engineering Design for Piperazine with the Advanced Stripper

This Department of Energy (DOE) funded project was executed with the goal of preparing a Front-End Engineering Design (FEED) for the capture and compression of 90% of the CO2 that would normally be emitted from an existing natural gas combined cycle (NGCC) plant. The FEED focused on the application of the piperazine advanced stripper (PZAS) process at Mustang Station of the Golden Spread Electric Cooperative (GSEC), which consists of two gas turbines with common heat recovery steam generator (HRSG). The University of Texas at Austin (UT) served as the prime contractor, and subcontracted AECOM Technical Services and Trimeric Corporation to support FEED development. This project team has worked together to advance PZAS for more than a decade. ExxonMobil, Chevron, and Total provided project co-funding. The objectives of this work included: 1. To advance engineering design such that a comprehensive estimate for the total installed cost of a full-scale PZAS CO2 Capture Plant with CO2 compression can be developed on an existing NGCC power plant. a. These detailed costs can also be used to qualify PZAS and other related second generation (2G) amine scrubbing processes for use on cogeneration facilities in refineries and chemical plants that use gas turbines with HRSGs to produce steam. b. These detailed costs will help qualify 2G amine scrubbing for use on NGCC power plants and establish a more accurate baseline cost to be used as a target by other capture technologies. 2. To provide cost details to be used in the economic optimization of the process features of PZAS and other 2G amine scrubbing processes. 3. To provide DOE with a more detailed understanding of carbon capture costs in a commercial application, enabling DOE to better design its R&D program to improve the economics for carbon capture. 4. To provide the host site and cost share partners with the information necessary to determine whether a commercial project to capture and use CO2 for enhanced oil recovery (EOR) or for sequestration can be justified (when accounting for the 45Q tax credit). A key component of the FEED is the estimated total installed cost, which provides a basis for the likely capital investment necessary to implement the PZAS carbon capture process at this location and scale. In combination with the included economic analysis, which accounts for potential revenue from the produced CO2, potential avenues to profitability are explored. The major findings of the FEED are as follows: The Mustang Station PZAS CO2 Capture Plant estimated total project cost of $698 MM of which $384 MM was direct costs. The annual operating costs were $32.6 MM. The total investment for a PZAS facility at Mustang Station is $725 MM. This estimate includes owner’s cost of $25 million and a contingency of $110 MM. • The study estimated the CO2 capture plant at Mustang Station would generate CO2 at $110/tonne for EOR, assuming a 12% IRR (internal rate of return) and an 85% capacity factor. For CO2 storage, the same case would achieve a 12% IRR at about $114/tonne. At a capacity factor of 52%, the storage and EOR cases would break even when carbon is priced ~$150/tonne. The economic analysis determined that the capacity factor and utility pricing, among other variable factors, had a significant effect on the economics and will need additional studied. • The energy penalty of the PZAS plant would be about 46 MW in connected power and 35 MW in operating load. The natural gas requirement (for the Gas Boiler package) would be about 354 MMBTU/hr. • The FEED revealed no major risks in process maturity. However, some areas were outlined for further engineering during detailed design, which included the Gas Boiler system, general arrangement and site layout, air coolers, schedule development, and optimization of the process for higher CO2 removal. • If PZAS were to be implemented at another host site, additional opportunities for cost reduction for would include cost reduction through use of cooling water and steam extraction.

03 NATURAL GAS↗

Integration Study of Converter-Interfaced Combined Heat and Power Plants

Combined Heat and Power (CHP) systems, as a proven technology, provide numerous benefits to the plant owner by saving electricity bill, reducing carbon dioxide emissions, and improving electricity service reliability. However, their integration into the distribution grid faces many barriers including the complexity of grid code requirements and the lack of technical expertise in commercial and small industrial plants to interface with the utility and accelerate the interconnection process. To solve these issues, this study proposes a converter-interfaced solution for CHP integration. Simulations including various fault scenarios and load flow under different grid conditions are carried out to compare technical performances of the proposed solution with directly-coupled CHP. Results show that the generator size of converter-interfaced CHP can be reduced by approximately 25% and it also provides advantageous features such as reduced stress level under fault conditions and a better dynamic stability margin. In addition, a power factor controller is designed and reactive power from CHP is dispatched in such a way that the CHP plant is compliant with power factor requirements from utilities under all operating conditions.

Converter, Combined heat and power, Distributed en↗

The computer simulation of automobile use patterns for defining battery requirements for electric cars

A Monte Carlo simulation process was used to develop the U.S. daily range requirements for an electric vehicle from probability distributions of trip lengths and frequencies and average annual mileage data. The analysis shows that a car in the U.S. with a practical daily range of 82 miles (132 km) can meet the needs of the owner on 95% of the days of the year, or at all times other than his long vacation trips. Increasing the range of the vehicle beyond this point will not make it more useful to the owner because it will still not provide intercity transportation. A daily range of 82 miles can be provided by an intermediate battery technology level characterized by an energy density of 30 to 50 watt-hours per pound (66 to 110 W-hr/kg). Candidate batteries in this class are nickel-zinc, nickel-iron, and iron-air. The implication of these results for the research goals of far-term battery systems suggests a shift in emphasis toward lower cost and greater life and away from high energy density.

Schwartz, H. J.↗

Emerging Trends and Systemic Issues Influencing Today’s U.S. Electric Grid

With increasing shifts from vertically integrated to horizontally structured operations and from centralized to distributed electric power delivery, today’s electric power grid (the “grid”) operators and designers face the challenge of creating an architecture that accommodates a host of diverse requirements. The grid’s modes of operation must address concerns of reliability and stability, new deployments of renewable energy sources, threats from cyber-attacks and natural disasters, and increasingly distributed system operations. Grid modernization calls for a reliable, affordable, sustainable, agile, secure, and resilient grid. However, the modernization of the U.S. power grid is hampered by mounting complexity and diverging objectives from owners and operators and is consequently risky and fraught with potential missteps. Flawed architecture, design, and implementation will lead to stranded investments and lost opportunities. A principled approach to minimize risk and develop a robust grid of the future is to begin with a sound architecture for the grid to inform the design process. Architecture development starts with the context of influencing factors that provide constraints as well as driving goals. This report provides the context of emerging trends and cross-cutting systemic issues in the U.S. electric power grid and serves as a vital input for grid architecture development.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tank Waste LDR Organics Data Summary for Sample-and-Send (Rev.1A)

The presence of organic chemicals regulated under the Resource Conservation and Recovery Act (RCRA) Land Disposal Restrictions (LDR) adds complexity to treating and disposing of the low activity fraction of Hanford tank waste if a low temperature treatment method such as grouting is used (SRNL-STI-2020-00228). The complexity arises from the fact that the baseline vitrification method is considered by the Washington State Department of Ecology (Ecology) as providing adequate thermal treatment for organics; a status not automatically extended to a lowtemperature process, such as solidifying the waste in a cementitious waste form. In addition, the Environmental Protection Agency (EPA) LDR program is intended to ensure that wastes are properly treated prior to disposal. Proper treatment makes hazardous waste less harmful to groundwater by reducing the mobility and/or toxicity of the hazardous constituents in the waste. EPA guidance indicates that stabilization/solidification of waste for organics could be considered impermissible dilution under the LDR dilution prohibition. In addition, waste storage activities at Hanford have required transferring and blending waste within the tank system and these activities have potentially altered the concentrations of the hazardous constituents. The LDR dilution prohibition found in 40 Code of Federal Regulations (CFR) 268.3 states that “… no generator, transporter, handler, or owner or operator of a treatment, storage, or disposal facility shall in any way dilute a restricted waste or the residual from treatment of a restricted waste as a substitute for adequate treatment …”. Hence, if LAW is to be treated using low temperature stabilization (such as cementation), then it is important to demonstrate both how past storage activities have contributed to the removal (by vacuum evaporation), or destruction (by in situ decomposition) of the LDR organics and how future retrieval and waste feed preparation will contribute to their removal (by filtration and ion exchange). Demonstrating these processes helps validate that cementation without additional organic treatment does not necessarily represent impermissible dilution. To aid in implementing cementitious solidification of Low Activity Waste (LAW), WRPS has been developing a regulatory and processing LDR treatment variance strategy termed “Sampleand-Send” that relies, in part, on demonstrating that in situ decomposition reactions along with historic evaporation of tank waste has destroyed or removed most of the LDR organics possibly associated with Hanford Tank Waste (SRNL-STI-2020-00582, SRNL-STI-2021-00453, SRNL-STI-2022-00391). Under the Sample-and-Send concept, Hanford tank waste would be retrieved, processed through a Tank-Side Cesium Removal-like system, and staged as a candidate feed that would then be sampled to confirm the waste acceptance criteria is met for solidification in an LAW cementitious treatment facility. If it can be shown that LDR organics are at concentrations below the waste acceptance criteria (WAC) for cementitious stabilization and have been sufficiently removed (by historic evaporation or by filtration and ion exchange during Cs removal), destroyed (by historic in situ decomposition), or are not soluble in LAW above the WAC then additional organic treatment is not needed prior to creating a cementitious final waste form and the concept of Sample-and-Send would be proposed to establish a non-rulemaking site-specific treatment variance using the specified method of treatment “STABL” to remove sampling requirements of the waste form after treatment. Waste not meeting the WAC could either be routed to the Hanford Waste Treatment and Immobilization Plant for LAW vitrification, or further processed by evaporation or chemical oxidation before solidifying in a cementitious waste form. A key component in implementing the Sample-and-Send strategy is identifying which of the 207 LDR organic compounds associated with the RCRA Part A permit application waste codes for the Double Shell Tanks (DSTs) and Single Shell Tanks (SSTs) and any applicable Underlying Hazardous Constituents (UHCs) from 40 CFR 268.48 should be considered as potentially present and thus subject to regulation. In addition, it is also necessary to understand the solubility volatility, and reactivity of these compounds in LAW to identify which of the potentially present LDR organic compounds are not soluble above regulatory levels or are likely to have been removed by historic evaporation or destroyed by in situ decomposition reactions. If there are potentially present LDR organic compounds that have not been removed or destroyed and are soluble above regulatorily significant concentrations then a treatability variance may be needed for these species to eliminate any concerns pertaining to impermissible dilution. The spreadsheet accompanying this calculation report contains the data and logic computations needed to screen the list of 207 LDR organics associated with Hanford tank waste to identify those potentially present and to indicate which compounds may need to be included in a treatability variance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Modern Methodologies with Maintenance Software

Jet Propulsion Laboratory uses multi-mission software produced by the Mission Planning and Sequencing (MPS) team to process, simulate, translate, and package the commands that are sent to a spacecraft. MPS works under the auspices of the Multi-Mission Ground Systems and Services (MGSS). This software consists of nineteen applications that are in maintenance. The MPS software is classified as either class B (mission critical) or class C (mission important). The scheduling of tasks is difficult because mission needs must be addressed prior to performing any other tasks and those needs often spring up unexpectedly. Keeping track of the tasks that everyone is working on is also difficult because each person is working on a different software component. Recently the group adopted the Scrum methodology for planning and scheduling tasks. Scrum is one of the newer methodologies typically used in agile development. In the Scrum development environment, teams pick their tasks that are to be completed within a sprint based on priority. The team specifies the sprint length usually a month or less. Scrum is typically used for new development of one application. In the Scrum methodology there is a scrum master who is a facilitator who tries to make sure that everything moves smoothly, a product owner who represents the user(s) of the software and the team. MPS is not the traditional environment for the Scrum methodology. MPS has many software applications in maintenance, team members who are working on disparate applications, many users, and is interruptible based on mission needs, issues and requirements. In order to use scrum, the methodology needed adaptation to MPS. Scrum was chosen because it is adaptable. This paper is about the development of the process for using scrum, a new development methodology, with a team that works on disparate interruptible tasks on multiple software applications.

Scrum↗

Preparing the FUSRAP Colonie Interim Storage Site for Transfer Back to the US Department of Energy Office of Legacy Management - 19215

The Formerly Utilized Sites Remedial Action Program (FUSRAP) Colonie Interim Storage Site was transferred from the US Department of Energy (US DOE) to the US Army Corps of Engineers (USACE) in 1997. The USACE initiated remediation efforts at the Site under FUSRAP. The Site was separated into three distinct operable units (OU) to more efficiently manage the remedial process: 1) Groundwater OU, 2) Main Site Soils OU, and 3) Vicinity Property OU. The USACE has completed remedial actions at each of these three OUs and has advanced the OU remedies at the Site to the long-term stewardship stage to be executed by the US DOE Office of Legacy Management (LM). The US DOE LM is the current real property owner of record of the Colonie Main Site. A summary of each OU and the activities needed to prepare for site transfer follows: OU 1 - USACE issued the Colonie Groundwater OU Record of Decision (ROD) (USACE 2010a) on April 9, 2010. The Groundwater ROD remedy is monitored natural attenuation (MNA) and long-term monitoring (LTM) of groundwater after source removal completion. Results of groundwater monitoring indicate reductions in concentrations of contaminants of concern (COC). Based on the marked progress to date, USACE has optimized the groundwater LTM program (USACE, 2014) by reducing the well network, sampling frequency, and analytical parameters, and by abandoning wells that are no longer needed. A Groundwater ROD Five-Year Review report was submitted to the New York State Department of Environmental Conservation (NYSDEC) for review in 2018. NYSDEC agreed that MNA is still an appropriate remedial method although it is progressing at a slower rate than predicted. OU 2 - From 1999 to 2007, USACE completed the large-scale removal of soil at the Main Site, which included the adjacent Town of Colonie Vicinity Property. Radioactively contaminated soil along with accessible metals-contaminated soil and soil containing volatile organic compounds (VOC) were removed during this effort. A total of 103,402 cubic meters (m{sup 3}) of soil was excavated and disposed offsite. On March 26, 2015, USACE signed the Main Site Soils OU ROD (USACE, 2015a). The ROD remedy included provisions for Land Use Controls (LUC) consisting of institutional controls (IC) through an Environmental Easement for management of three small and discrete inaccessible locations within three of the 27 Final Status Survey units of the Main Site. The Environmental Easement provides a means of protection based on both current and future land use by placing restrictions on soil excavation and reuse. The easement and a supporting Site Management Plan (SMP) will be finalized by LM in coordination with NYSDEC. OU 3 - the Vicinity Property OU ROD was signed on 20 September 2017. This ROD declared No Action (NA) for dust and No Further Action (NFA) for soil and other media for the Vicinity Properties. Prior to the ROD, USACE performed dust sampling and other characterization activities at representative commercial and residential Vicinity Property locations. These efforts were reported in the Colonie FUSRAP Site Vicinity Property Operable Unit Remedial Investigation Summary Report (USACE, 2016). A Site Closeout Report (SCOR) was issued to NYSDEC and approved in 2018. The approval of this report starts the transfer process back to the LM. Ongoing and future transfer activities include records retention and management, preparation and filing of real estate records, physical site management (fencing, landscape maintenance, well abandonment) and coordination with state regulators and LM staff. This presentation is intended to make all stakeholders aware of the necessary steps for site transfer from the USACE back to the LM. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Navigating Cybersecurity Implications of Smart Outlets

Plug and process loads (PPLs) consume approximately one third of U.S. buildings' energy budget. As other equipment becomes more efficient, and plug-in devices diversify in the market, the percentage of PPL energy consumption is forecasted to grow. To help combat this growth, new wireless metering and control technologies (also known as 'smart outlets') are helping building owners to collect plug load data, understand usage patterns, and implement controls. Adoption of these new connected technologies motivates serious cybersecurity consideration. Because these new technologies are developing at such a rapid pace, the aim of this paper is to inform thinking about cybersecurity issues and the risks that they impose. Through this lens, we explore the pros and cons of plug load controllers, provide a framework for assessing cybersecurity of connected devices such as plug load controllers, and offer an example of how commercial building owners could use this framework to minimize their cybersecurity risks when adopting smart products. In providing this framework, this paper aims to remove some barriers to implementation of these energy efficient technologies in the built environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insider Threat Cybersecurity Framework Webtool & Methodology: Defending Against Complex Cyber-Physical Threats

The paper demonstrates how the Insider Threat Cybersecurity Framework (ITCF) web tool and methodology help provide a more dynamic, defense-in-depth security posture against insider cyber-physical threats. ITCF includes over 30 cyber-physical security best practices to help organizations identify, protect, detect, respond and recover to sophisticated insider threats and vulnerabilities. The following paper tests the efficacy of this approach and helps validate and verify ITCF’s capabilities and features through various insider attacks use-cases. Three different investment scenarios and explored to determine how an organization can most efficiently leverage ICTF to increase their overall security posture against insider attacks. ITCF also facilitates implementation of the goals outlined in Presidential Executive Order (EO) on Strengthening the Cybersecurity of Federal Networks and Critical Infrastructure (May 2017): To help owners and operators of critical infrastructure identify, protect, detect, respond, and recover cyber threats. ITCF helps organizations with the following features: provides an easy to use rapid assessment tool to perform an insider threat self-assessment; determines the current insider threat cybersecurity posture; defines investment based goals to achieve a target state; connects the cybersecurity posture with business processes, functions, and continuity; and finally, helps develop plans to answer critical organizational cybersecurity questions. In this paper, the webtool and its core capabilities are depicted by performing an extensive comparative assessment over two different high-profile insider threat incidents.

Mylrea, Michael E.↗

Development of the Technical Basis of a Unified Viscoplastic Model of 316H Stainless Steel for Incorporation into ASME Division 5

This report describes the development of a unified viscoplastic model describing the deformation of 316 stainless steel. The model was developed for incorporation into Section III, Division 5 of the ASME Boiler and Pressure Vessel Code covering the design and fabrication of Class A high temperature nuclear reactor components. The current version of the Code does not provide reference inelastic models, leaving the responsibility of defining an adequate model up to either the plant owner or designer. This approach represents a substantial barrier to using the ASME design by inelastic analysis methods. As historical practice demonstrates these methods produce much more efficient designs, compared to the design by elastic analysis methods, eliminating this barrier could result in safer, more effective, and more efficient structural designs thereby lowering the cost of future advanced reactors. This report summarizes the process of gathering experimental data, calibrating the candidate inelastic model against that data, and validating the model. The report also summarizes work on a new method of calculating the sensitivities of history dependent nonlinear constitutive models that was used to calibrate the 316H model using gradient-based optimization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Economic Assessment of Nuclear Hybrid Energy Systems: Nuclear-Renewable-Water Integration in Arizona

One of the goals of the Nuclear-Renewable Hybrid Energy Systems (N-R HES) modeling and simulation (M&S) project is to assess the economic viability of N-R HES in a market that contains Variable Renewable Energy (VRE) sources like solar. The N-R HES M&S project is a multi-laboratory effort, led by Idaho National Laboratory (INL) and supported by Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL). Development of the N-R HES software framework was initiated at INL in 2016 [1] and has reached some level of maturity such that it can be applied to more than simple demonstration cases, e.g. real industry problems. Nevertheless, more capabilities are constantly added to accommodate the special needs of challenging, real-life problems. The N-R HES framework is built on the Risk Analysis Virtual ENvironment (RAVEN) code [2], which it uses as a driver and workflow manager for all calculations. There are four main cornerstones of the N-R HES simulation framework: 1) The generation of stochastic synthetic time series. 2) A set of probabilistic analysis and optimization algorithms available in RAVEN. 3) A set of models for representing the physical behavior of N-R HES. These can be reduced-order models or high-fidelity Modelica [3] models. 4) The RAVEN plug-in called CashFlow [4] that maps physical performance into economic performance. Within this framework, a broad spectrum of questions related to N-R HES can be addressed. One of the challenges currently of high interest is the increasing penetration of VRE altering the profile of the net demand (demand after removing all non-curtailable renewable energy sources, e.g. rooftop solar). The N-R HES software framework is capable of analyzing the potential feasibility of mitigating the resultant volatility in the net electricity demand. One possible solution to manage net demand volatility is adding stabilizing loads to the grid. These loads can be external industrial processes that are able to ramp production up and down quickly, or for regulated markets, adding variable internal loads that will effectively increase the baseload of the power plant and therefore reduce the risk of internal demand that is lower than the capacity of the power plant. The latter is a possible solution currently being considered by Arizona Public Service (APS), the operating owner of the Palo Verde (PV) Nuclear Power Plant (NPP).

97 MATHEMATICS AND COMPUTING↗

Energy Efficiency and the Real Estate Lifecycle: Stakeholder Perspectives

This report characterizes opportunities and pitfalls for leveraging key building lifecycle “events” as intervention points to enhance energy efficiency in real estate portfolios. It is based primarily on 33 interviews conducted with key industry stakeholders, including commercial real estate owners, operators, tenants, investors, developers, vendors, architecture/engineering firms, and construction managers. We focus on the following key events in the real estate life cycle because they are likely to present an opportunity for energy efficiency improvements: a) purchase or sale of a property; b) renovation; c) major equipment replacement; d) lease turnover or renewal; and e) refinancing. The stakeholder interviews covered business roles and processes, priorities, and sensitivities in these commercial real estate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data Processing Pipeline To Extract A Knowledge Graph From Heterogeneous Data For Socio-technical Analysis Of Critical Infrastructure Influence

The code is written in Python and consists of the following pipeline that is implemented in Apache Airflow. This pipeline intends to understand the companies that are directly or indirectly involved with a type of critical infrastructure system at some point in that system's lifecycle. The pipeline takes a configuration file that specifies a list of initial companies to consider, a geographic region of interest, and a set of SEC form types as well as other data sources (e.g. CrunchBase) from which to extract entities and relations. There are four main components to this pipeline as currently implemented: Entity Extraction, Network Construction, Analysis, and Visualization. First, Entity Extraction, is implemented as the `topear-extract_organizations` Apache Airflow workflow. Given an initial query that specifies a geographic region of interest and a time interval, the software will extract CI facilities of interest and organizations that have a direct influence relationship to those facilities (e.g. ownership). During the course of the LDRD, we focused on Electric Vehicle charging stations and this information is available via the Department of Energy (DOE) database on fueling stations maintained by NREL. Within the context of the DOE CESER project, we have focused on Battery Energy Storage Systems (BESS). Second, the Network Extraction component will iteratively construct a social network graph given the set of organizations and people extracted in the previous step. Organizations (and eventually People if desired) are then fed as a query to the `topgear-construct_social_network` Apache Airflow workflow which given a set of initial companies and data sets (e.g. SEC EDGAR form types, OpenCorporates, Crunchbase). This Airflow workflow will iteratively query such data sources to discover relationships with new organizations and people. For example, this module can iteratively query SEC EDGAR for metadata that documents the number of each type of form for the given set of companies and their location. This forms metadata represents a catalog of data sources from SEC EDGAR for the extracted social network knowledge graph. The pipeline then downloads these forms from the website and saves them in a build directory for further processing. These documents are then parsed for entities and relations. Again, we note that in additional to SEC data sources, this step can also pull in information on organizations via API services such as CrunchBase and OpenCorporates or bulk data sources. At the end of this step, the resultant social network, the Critical Infrastructure network, and the edges that encode relationships between organizations and CI facilities, form the Adversarial Socio-Technical Network (ASTN) that informs the analysis. Third, the Analysis component processes these generated ASTN. Previously, that has included the ability to compare prevalence of different vendors for a given infrastructure component type across different regions as well as identify common public and private investors across those vendors. This was demonstrated for EV Charging Stations across several different metropolitan areas within an IEEE PES GridEdge publication. More recently, we have looked at ways to identify infrastructure owners and operators of BESS with the most nameplate capacity across different states as well as other indictors of risk resulting from changes in ownership over time. Finally, the Visualization component consists of an HTML/CSS/JS framework by which users can interact geospatial, operational, and organizational relationships across a given portfolio of Critical Infrastructure facilities. The objective is to provide a library of UI/UX modules that can be repurposed for stakeholder-specific dashboards. All of the modules are related via a common event model that enables UI actions in one view to percolate across the other views.

Weaver, Gabriel [Idaho National Laboratory (INL), ↗

Concentrating Solar Power Best Practices Study

The primary objective of this Concentrating Solar Power Best Practices Study is to publish best practices and lessons learned from the engineering, construction, commissioning, operations, and maintenance of existing concentrating solar power (CSP) parabolic trough and power tower systems. To accomplish this objective, information was solicited from many owners, operators, and engineering, procurement, and construction (EPC) contractors, independent engineers, and other stakeholders of parabolic trough and central receiver plants (also commonly referred to as power towers). Information was gathered through in-person or online meetings, site visits, and questionnaires sent to participants. The project team held about 50 information-gathering sessions with participants over the course this effort; and in the process, it collected information from participants representing nearly 80% of CSP plants operating worldwide.

14 SOLAR ENERGY↗

The Value of Being a Trustworthy Repository

Today, NASA's Earth Observing System Data and Information System (EOSDIS), a system ofactive archives is attaching the CoreTrustSeal to its websites signifying that it merits theconfidence of its user community. But what value does being a trustworthy repository impart to auser? What does it mean to the owners and operators of repositories? What will it mean in thefuture? EOSDIS was started in the 1990s based on a framework of discipline-oriented, geographicallydistributed centers of expertise, named Distributed Active Archive Centers (DAACs). The functionof EOSDIS is to collect Earth Science data sensor measurements (principally those created andneeded by NASA) and manage the data and many derived digital products. EOSDIS providesmany services, including processing, curating, documenting, disseminating, and enabling datadiscovery as well as efficient use of the data. The EOSDIS has been operational over 25 years andmany lessons have been learned relative to the TRUST principles. During the tenure of EOSDIS,many changes have occurred as we have increased the size of the collection from gigabytes totens of petabytes and the distribution of the data to millions of users. We have had severalstages of system evolution that have improved EOSDIS in order to meet both stakeholder andcustomer expectations. This type of evolution is an on-going process to ensure that ourrepositories remain trustworthy. It is also important that our own community of data managersand system engineers add value in being trustworthy. This paper will discuss approaches to change within a large system of Earth Science data and services, while remaining a trustworthyrepository.

Behnke, Jeanne↗

Innovation in Radiological Security, Part 2 of 2 – Insights into Developing a Cloud-hosted Security Technology

A Sentry Remote Monitoring System (Sentry-RMS) is a stand-alone security system that provides detection, assessment, and communication of priority alarms as an additional means of thwarting internal and external threats to sites that maintain radiological material. The SEntry-RMS CommUnications and REsponse (Sentry-SECURE) platform is an optional feature of the Sentry-RMS that relays priority alarm information to the identified response stakeholders. Sentry-SECURE is hosted in a cloud environment that abstracts the data owner’s and data consumer’s platforms to allow for greater information sharing. This promotes situational awareness amongst authorized users and enables future innovation among modern response platforms. When securely architecting a cloud solution such as this, the use of design paradigms can be an effective tool to increase the accuracy and reliability of cyber- and information-security-related decisions made throughout the development process. This approach also supports the categorization of design considerations into three levels: industry concepts, project approaches, and data protections for digital processes. Industry concepts consist of the notional underpinnings that guide or motivate a security process, system, or design but often lack any tangible attributes. Project approaches represent decisions made during the design and development process to prioritize a solution, method, or practice above another that may provide a comparable functional output but lacks a desired security benefit. Data protections for digital processes represent the selection, integration, and implementation of specific controls for a given asset. This paper will explore specific examples of how Sentry-SECURE has been designed to account for considerations at each of these three levels, while balancing the operational intent of the platform with the security enhancements necessary to maintain data integrity, availability, and confidentiality.

assessment, RMS, security, physical, cloud, Cyber ↗

A method for processing the Confidential Carload Waybill Sample for railroad freight analysis

Freight transportation research is often constrained by the availability of appropriate data. Within the context of freight rail research, use of traditional freight datasets present some critical challenges. Aggregating freight data to geographic areas diminishes the ability to perform nuanced analysis. More challenging, the complexity of railroad operations limits the usability of publicly available freight flow data which do not account for which rail company is economically and legally responsible for the movement of the goods or for the contractual arrangements between infrastructure owners and carriers. Finally, detailed data are usually privately owned and not readily-accessible for analysis outside the individual rail companies. As part of their regulatory authority, the Surface Transportation Board has developed the Confidential Carload Waybill Sample, a stratified sample representing 1% to 3% of all rail traffic in the United States for a particular year. While the sample is rich with data, it is limited in spatial information as well as in its implementation in geospatial analysis. This paper introduces a methodology for geospatially enabling the Confidential Carload Waybill Sample which can then be used to generate rail routes based on a topological representation of the U.S. railroad network. As a result, this methodology is applied using two case studies, a freight diversion analysis and transporting hazardous materials.

42 ENGINEERING↗