Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Intensity Gamma-Ray Source(HIγS) Radiographic Experiments

High Intensity Gamma-ray Source (HIGS) is a Free-Electron Laser (FEL) based Compton back-scattering γ-ray source. The HIGS facility is located on the campus of Duke University and operated by Triangle Universities Nuclear Laboratory (TUNL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overcoming Barriers to Radiopharmaceutical Therapy (RPT): An Overview From the NRG-NCI Working Group on Dosimetry of Radiopharmaceutical Therapy

Radiopharmaceutical therapy (RPT) continues to demonstrate tremendous potential in improving the therapeutic gains in radiation therapy by specifically delivering radiation to tumors that can be well assessed in terms of dosimetry and imaging. Dosimetry in external beam radiation therapy is standard practice. This is not the case, however, in RPT. This NRG (acronym formed from the first letter of the 3 original groups: National Surgical Adjuvant Breast and Bowel Project, the Radiation Therapy Oncology Group, and the Gynecologic Oncology Group)-National Cancer Institute Working Group review describes some of the challenges to improving RPT. The main priorities for advancing the field include (1) developing and adopting best practice guidelines for incorporating patient-specific dosimetry for RPT that can be used at both large clinics with substantial resources and more modest clinics that have limited resources, (2) establishing and improving strategies for introducing new radiopharmaceuticals for clinical investigation, (3) developing approaches to address the radiophobia that is associated with the administration of radioactivity for cancer therapy, and (4) solving the financial and logistical issues of expertise and training in the developing field of RPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

A novel data gaps filling method for solar PV output forecasting

This study proposes a modified gaps filling method, expanding the column mean imputation method and evaluated using randomly generated missing values comprising 5%, 10%, 15%, and 20% of the original data on power output. The XGBoost algorithm was implemented as a forecasting model using the original and processed datasets and two sources of solar radiation data, namely, Shortwave Radiation (SWR) from Advanced Himawari Imager 8 (AHI-8) and Surface Solar Radiation Downward (SSRD) from ERA5 global reanalysis data. Further, the accuracy of the two sets of forecasted power output was evaluated using Root Mean Square Error (RMSE) and Mean Absolute Error (MAE). Results show that by applying the proposed gap filling method and using SWR in forecasting solar photovoltaic (PV) output, the improvement in the RMSE and MAE values range from 12.52% to 24.30% and from 21.10% to 31.31%, respectively. Meanwhile, using SSRD, the improvement in the RMSE values range from 14.01% to 28.54% and MAE values from 22.39% to 35.53%. To further evaluate the accuracy of the proposed gap-filling method, the proposed method could be validated using different datasets and other forecasting methods. Future studies could also consider applying the said method to datasets with data gaps higher than 20%.

Energy & Fuels↗

Toward “super-scintillation” with nanomaterials and nanophotonics

Abstract Following the discovery of X-rays, scintillators are commonly used as high-energy radiation sensors in diagnostic medical imaging, high-energy physics, astrophysics, environmental radiation monitoring, and security inspections. Conventional scintillators face intrinsic limitations including a low extraction efficiency of scintillated light and a low emission rate, leading to efficiencies that are less than 10 % for commercial scintillators. Overcoming these limitations will require new materials including scintillating nanomaterials (“nanoscintillators”), as well as new photonic approaches that increase the efficiency of the scintillation process, increase the emission rate of materials, and control the directivity of the scintillated light. In this perspective, we describe emerging nanoscintillating materials and three nanophotonic platforms: (i) plasmonic nanoresonators, (ii) photonic crystals, and (iii) high-Q metasurfaces that could enable high performance scintillators. We further discuss how a combination of nanoscintillators and photonic structures can yield a “super scintillator” enabling ultimate spatio-temporal resolution while enabling a significant boost in the extracted scintillation emission.

Carr Delgado, Hamish↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Increased AGE Cross-Linking Reduces the Mechanical Properties of Osteons

Abstract The osteon is the primary structural component of bone, contributing significantly to its unique toughness and strength. Despite extensive research on osteonal structure, the properties of osteons have not been fully investigated, particularly within the context of bone fragility diseases like type 2 diabetes mellitus (T2DM). This study aims to isolate osteons from bovine bone, simulate the effects of increased advanced glycation end-products (AGEs) in T2DM through ribosylation, and evaluate the mechanical properties of isolated osteons. Osteons extracted from the posterior section of bovine femur mid-diaphysis were processed to achieve a sub-millimeter scale for microscale imaging. Subsequently, synchrotron radiation micro-computed tomography was employed to precisely localize and isolate the osteon internally. While comparable elastic properties were observed between control and ribosylated osteons, the presence of AGEs led to decreased strain to failure. Young’s modulus was quantified (9.9 ± 4.9 GPa and 8.7 ± 3 GPa, respectively), aligning closely with existing literature. This study presents a novel method for the extraction and isolation of osteons from bone and shows the detrimental effect of AGEs at the osteonal level.

Materials Science↗

Charge collection efficiency of diamond and silicon sensors irradiated with alpha particles

To evaluate the viability of using semiconductors as sensor materials in a detector for the Associated Particle Imaging technique, the radiation hardness of silicon and diamond diodes to alpha particles has been assessed. Here, the detector lifetimes for both silicon and diamond sensors were measured under the prolonged exposure to alpha particles emitted by an 241 Am source. The silicon detector was exposed to alpha radiation for approximately two months, reaching an accumulated fluence of ~ 1.5 x 10 12 α cm –2 . Additionally, by using a high purity single-crystal diamond with coplanar electrodes operating with full charge collection, the diamond detector response was measured over approximately ten months reaching an accumulated fluence of over 6 x 10 12 α cm –2 cm.

47 OTHER INSTRUMENTATION↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗