Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reflective Solar Bands”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Products of the SNPP VIIRS SD Screen Transmittance and the SD BRDFs From Both Yaw Maneuver and Regular On-Orbit Data

To ensure data quality, the Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly performs on-orbit radiometric calibration of its 22 spectral bands. The primary radiance source for the calibration of the VIIRS reflective solar bands (RSBs) is a sunlit onboard solar diffuser (SD).During the calibration process, sunlight goes through a perforated plate (the SD screen) and then strikes the SD. The sunlight, scattered off the SD of near-Lambertian property, is used for the calibration. Consequently, the spectral radiance of the scattered sunlight is proportional to the product of the SD screen transmittance and the SD bidirectional reflectance distribution function (BRDF) value at the observation direction. The BRDF value is decomposed to the product of its initial value at launch and a numerical degradation factor that quantifies the decrease from the initial value. The degradation factor is determined by an onboard SD stability monitor (SDSM). During the BRDF degradation factor determination process, the SDSM receives the SD scattered sunlight and the sunlight that goes through another perforated plate at almost the same time. The ratio of the signal strengths from the two observations is used to determine the BRDF degradation factor. Consequently, the RSB radiometric calibration requires the accurate knowledge of the product of the SD screen transmittance and the initial BRDF value as sensed by the RSB and the SDSM detectors. We use both yaw maneuver and a small portion of regular on-orbit data to determine the products.

Lei, Ning↗

Impact of MODIS SWIR Band Calibration Improvements on Level-3 Atmospheric Products

The spectral reflectance measured by the MODIS reflective solar bands (RSB) is used for retrieving many atmospheric science products. The accuracy of these products depends on the accuracy of the calibration of the RSB. To this end, the RSB of the MODIS instruments are primarily calibrated on-orbit using regular solar diffuser (SD) observations. For lambda < 0.94 microns the SDs on-orbit bi-directional reflectance factor (BRF) change is tracked using solar diffuser stability monitor (SDSM) observations. For lambda > 0.94 microns, the MODIS Characterization Support Team (MCST) developed, in MODIS Collection 6 (C6), a time-dependent correction using observations from pseudo-invariant earth-scene targets. This correction has been implemented in C6 for the Terra MODIS 1.24 micron band over the entire mission, and for the 1.375 micron band in the forward processing. As the instruments continue to operate beyond their design lifetime of six years, a similar correction is planned for other short-wave infrared (SWIR) bands as well. MODIS SWIR bands are used in deriving atmosphere products, including aerosol optical thickness, atmospheric total column water vapor, cloud fraction and cloud optical depth. The SD degradation correction in Terra bands 5 and 26 impact the spectral radiance and therefore the retrieval of these atmosphere products. Here, we describe the corrections to Bands 5 (1.24 microns) and 26 (1.375 microns), and produce three sets (B5, B26 correction on/on, on/off, and off/off) of Terra-MODIS Level 1B (calibrated radiance product) data. By comparing products derived from these corrected and uncorrected Terra MODIS Level 1B (L1B) calibrations, dozens of L3 atmosphere products are surveyed for changes caused by the corrections, and representative results are presented. Aerosol and water vapor products show only small local changes, while some cloud products can change locally by > 10%, which is a large change.

Calibration↗

NPP VIIRS On-Orbit Calibration and Characterization Using the Moon

The Visible Infrared Imager Radiometer Suite (VIIRS) is one of five instruments on-board the Suomi National Polar orbiting Partnership (NPP) satellite that launched from Vandenberg Air Force Base, Calif., on Oct. 28, 2011. VIIRS has been scheduled to view the Moon approximately monthly with a spacecraft roll maneuver after its NADIR door open on November 21, 2011. To reduce the uncertainty of the radiometric calibration due to the view geometry, the lunar phase angles of the scheduled lunar observations were confined in the range from -56 deg to -55 deg in the first three scheduled lunar observations and then changed to the range from -51.5 deg to -50.5 deg, where the negative sign for the phase angles indicates that the VIIRS views a waxing moon. Unlike the MODIS lunar observations, most scheduled VIIRS lunar views occur on the day side of the Earth. For the safety of the instrument, the roll angles of the scheduled VIIRS lunar observations are required to be within [-14 deg, 0 deg] and the aforementioned change of the phase angle range was aimed to further minimize the roll angle required for each lunar observation while keeping the number of months in which the moon can be viewed by the VIIRS instrument each year unchanged. The lunar observations can be used to identify if there is crosstalk in VIIRS bands and to track on-orbit changes in VIIRS Reflective Solar Bands (RSB) detector gains. In this paper, we report our results using the lunar observations to examine the on-orbit crosstalk effects among NPP VIIRS bands, to track the VIIRS RSB gain changes in first few months on-orbit, and to compare the gain changes derived from lunar and SD/SDSM calibration.

Sun, J.↗

Earthshine as an Illumination Source at the Moon

Earthshine is the dominant source of natural illumination on the surface of the Moon during lunar night, and at some locations within permanently shadowed regions (PSRs) near the poles that never receive direct sunlight. As such, earthshine has the potential to enable the scientific investigation and exploration of conditions in areas of the Moon that are either temporarily or permanently hidden from the Sun. Earthshine has also been used to refer to Earthlight reflected from the lunar surface, but in this study we use it to refer specifically to Earthlight incident at the Moon. Under certain circumstances, the heat flux from earthshine could also influence the transport and cold-trapping of volatiles present in the very coldest areas within PSRs. In this study, Earth's spectral irradiance, as it would appear at the Moon in the solar reflectance band (0.3–3.0 µm) and at thermal emission wavelengths (3–50 µm), is examined with a suite of model image cubes and whole-disk spectra created using the Virtual Planetary Laboratory (VPL) three-dimensional (latitude, longitude and altitude) modeling capability. At the Moon, the broadband, hemispherical irradiance from Earth at full-phase is approximately 0.15 W m−2 with comparable contributions from solar reflectance and thermal emission; for context, this about 0.01% that of solar irradiance and has an equivalent temperature of around 40 K. Over the simulated timeframe, spanning two lunations, Earth's thermal irradiance shows very little net change (less than a few mW m−2 resulting from cloud variability and the south-to-north motion of the sub-observer latitude on Earth). In the solar band, Earth's diurnally averaged light curve at phase angles g ≤ 60° is well-fit using a Henyey–Greenstein integral phase function. At wavelengths longward of about 0.7 µm, near the well-known vegetation “red edge”, Earth's reflected solar radiance shows significant diurnal modulation as a result of the broad maximum in projected landmass at terrestrial longitudes between 60°W and 0°, as well as from the distribution of clouds. A simple formulation with adjustable coefficients is presented, condensed from the VPL model grid, for estimating Earth's hemispherical irradiance at the Moon as a function of wavelength, phase angle and sub-observer coordinates (terrestrial latitude and longitude). Uncertainties in any one prediction are estimated to be 10–12% at 0.3 µm, rising to >25% near 2.5 µm as a result of the increasing relative brightness and unpredictable influence of clouds. Although coefficient values are derived from a suite of spring equinox models, the approximation appears to be valid for all seasons, to within the stated uncertainties. It is demonstrated that earthshine is sufficiently bright to serve as a natural illumination source for optical measurements on a robotic lander/rover, allowing the identification of water ice mixed with regolith at the percent-level of fractional area.

Surface↗

Status of Terra MODIS Operation, Calibration, and Performance

Since launch in December 1999, Terra MODIS has successfully operated for nearly 15 years, making continuous observations. Data products derived from MODIS observations have significantly contributed to a wide range of studies of key geophysical parameters of the earth's eco-system of land, ocean, and atmosphere, and their changes over time. The quality of MODIS data products relies on the dedicated effort to monitor and sustain instrument health and operation, to calibrate and update sensor parameters and properties, and to improve calibration algorithms. MODIS observations are made in 36 spectral bands, covering wavelengths from visible to long-wave infrared. The reflective solar bands (1-19 and 26) are primarily calibrated by a solar diffuser (SD) panel and regularly scheduled lunar observations. The thermal emissive bands (20-25 and 27- 36) calibration is referenced to an on-board blackbody (BB) source. On-orbit changes in the sensor spectral and spatial characteristics are monitored by a spectroradiometric calibration assembly (SRCA). This paper provides an overview of Terra MODIS on-orbit operation and calibration activities and implementation strategies. It presents and summarizes sensor on-orbit performance using nearly 15 years of data from its telemetry, on-board calibrators, and lunar observations. Also discussed in this paper are changes in sensor characteristics, corrections applied to maintain MODIS level 1B (L1B) data quality, and efforts for future improvements.

Terra↗

Assessment of MODIS On-orbit Polarization Impact on Detector Relative Calibration

The Moderate-Resolution Imaging Spectroradiometer (MODIS) has been maintained its nominal operations since it was launched in December 1999 on Terra and May 2002 on Aqua spacecraft, respectively. MODIS is a scanning radiometer with a two-sided mirror that scans the Earth over an angular range from -55° to +55° off nadir and covers a wavelength range from 0.4 to 14.4 μm in 36 spectral bands. The sensitivity to polarization was fully characterized during prelaunch characterization for each reflective solar band (RSB), detector and mirror side as a function of scan angle. It was observed that while on-orbit polarization sensitivity for Aqua MODIS has been stable over the course of mission, the Terra MODIS polarization sensitivity at a few short wavelengths showed a significant increase near the end of scan angle after a few years in the mission. Our previous study examined the impact of polarization on the measured top-of-atmosphere reflectances obtained over the pseudo-invariant desert sites. There are up to 25% change in gain and 30% seasonal variation in select Terra RSBs due to the increase in polarization sensitivity. In this study, we examine relative changes in the polarization sensitivity of detectors within a band. Results from prelaunch tests indicate that there is a noticeable detector dependent polarization sensitivity and it is expected that such a dependency could change on orbit, particularly for Terra MODIS. Results of this study provide useful information on polarization impact and implementation of the correction algorithm.

MODIS↗

MODIS Solar Diffuser Attenuation Screen Modeling Results

On-orbit calibration of the reflected solar bands on the EOS Moderate Resolution Imaging Spectroradiometer (MODIS) is accomplished by have the instrument view a high reflectance diffuse surface illuminated by the sun. For some of the spectral bands this proves to be much too bright a signal that results in the saturation of detectors designed for measuring low reflectance (ocean) surfaces signals. A mechanical attenuation device in the form of a pin hole screen is used to reduce the signals to calibrate these bands. The sensor response to solar illumination of the SD with and without the attenuation screen in place will be presented. The MODIS detector response to the solar diffuser is smooth when the attenuation screen is absent, but has structures up to a few percent when the attenuation screen is present. This structure corresponds to non-uniform illumination from the solar diffuser. Each pin hole produces a pin-hole image of the sun on the solar diffuser, and there are very many pin hole images of the sun on the solar diffuser for each MODIS detector. Even though there are very many pin-hole images of the sun on the solar diffuser, it is no longer perfectly uniformly illuminated. This non-uniformly illuminated solar diffuser produces intensity variation on the focal planes. The results of a very detailed simulation will be discussed which show how the illumination of the focal plane changes as a result of the attenuation, and the impacts on the calibration will be discussed.

Waluschka, Eugene↗

Overview of Aqua MODIS 10-year On-orbit Calibration and Performance

Since launch in May 2002, Aqua MODIS has successfully operated for nearly 10 years, continuously collecting global datasets for scientific studies of key parameters of the earth's land, ocean, and atmospheric properties and their changes over time. The quality of these geophysical parameters relies on the input quality of sensor calibrated radiances. MODIS observations are made in 36 spectral bands with wavelengths ranging from visible (VIS) to longwave infrared (LWIR). Its reflective solar bands (RSB) are calibrated using data collected from its on-board solar diffuser and regularly scheduled lunar views. The thermal emissive bands (TEB) are calibrated using an on-board blackbody (BB). The changes in the sensor's spectral and spatial characteristics are monitored by an on-board spectroradiometric calibration assembly (SRCA). This paper presents an overview of Aqua MODIS 10-year on-orbit operation and calibration activities, from launch to present, and summarizes its on-orbit radiometric, spectral, and spatial calibration and characterization performance. In addition, it will illustrate and discuss on-orbit changes in sensor characteristics and corrections applied to continuously maintain the sensor level 1B (L1B) data quality, as well as lessons learned that could benefit future calibration efforts.

Xiong, X.↗

Determination of the SNPP VIIRS SDSM Screen Relative Transmittance From Both Yaw Maneuver and Regular On-Orbit Data

The Visible Infrared Imaging Radiometer Suiteaboard the Suomi National Polar-orbiting Partnership (SNPP) satellite performs radiometric calibration of its reflective solar bands primarily through observing a sunlit onboard solar diffuser (SD). The SD bidirectional reflectance distribution function(BRDF) degradation factor is determined by an onboard SD stability monitor (SDSM), which observes the Sun through a pinhole screen and the sunlit SD. The transmittance of the SDSM pinhole screen over a range of solar angles was determined prelaunch and used initially to determine the BRDF degradation factor.The degradation-factor-versus-time curves were found to have a number of very large unphysical undulations likely due to the inaccuracy in the prelaunch determined SDSM screen transmittance.To refine the SDSM screen transmittance, satellite yaw maneuvers were carried out. With the SDSM screen relative transmittance determined from the yaw maneuver data, the computed BRDFdegradation factor curves still have large unphysical ripples, indicating that the projected solar horizontal angular step size in the yaw maneuver data is too large to resolve the transmittance at a fine angular scale. We develop a methodology to use both the yaw maneuver and a small portion of regular on-orbit data to determine the SDSM screen relative transmittance at a fine angular scale. We determine that the error standard deviation of the calculated relative transmittance ranges from 0.00030 (672 nm) to 0.00092 (926 nm). With the newly determined SDSM screen relative transmittance, the computed BRDF degradation factor behaves much more smoothly over time.

Lei, Ning↗

Comparison of MODIS Solar Diffuser Stability Monitor Calibration Results for Different Operational Configurations

The MODIS instruments on the Terra and Aqua spacecraft use a sunlit solar diffuser (SD), with an optional SD attenuation screen (SDS), to calibrate the reflective solar bands. A solar diffuser stability monitor (SDSM) is used to track the SD reflectance degradation on orbit, by taking a ratio of the detector response when viewing the SD compared to the response when viewing the sun. The MODIS SDSMs have been operated both with and without the SDS in place. The SDSMs have also been operated in both a fixed and an alternating mode. In the alternating mode, the SDSM detectors view the SD, sun, and a dark background in an alternating pattern with the view changing on every MODIS scan within a single orbit. In the fixed mode, the SDSM detectors are fixed on the sun view for one orbit, and then are fixed on the SD view for the following orbit. This paper reviews the history of the SDSM operational configurations used throughout the MODIS missions and discusses the differences in the SD degradation results, which may be due to differences in sun-satellite geometry, SD signal level, and stray light effects. We highlight Aqua SDSM results from two recent dates in October 2017 and July 2019, where both the fixed and alternating mode calibrations were run on the same day, providing clear examples of the calibration differences. Additionally, we show how mixing the results from calibrations done with and without the SDS for Aqua MODIS can provide more stable results.

Twedt, Kevin A.↗

On-Orbit Tracking of Sub-Sample Gain Differences in SNPP and NOAA-20 VIIRS Imagery Bands

The VIIRS instruments on board the SNPP and NOAA-20 (N20) satellites have 14 reflective solar bands covering a spectral range from 412 nm to 2250 nm. Three of these are imaging bands (I bands) with a nadir spatial resolution of 375 m and 11 are moderate resolution bands (M bands) with a resolution of 750 m. The higher resolution in the I bands is achieved by a combination of more detectors, with the I bands having twice as many detectors of half the size for every M band detector, and a higher data rate, with the I bands having two sub-samples for every sample of M band data. To ensure calibration accuracy, any systematic difference in the response of the two sub-samples needs to be monitored and corrected in the calibrated products. In this paper, we use the solar diffuser calibrations to monitor the gain differences between the two sub-samples of the I bands both as a function of time and signal level. We find gain differences of about 0.1% for I1, 0.3% for I2, and <0.1% for I3 that are mostly constant over the range of signal values available in the SD calibration. These values are mostly consistent throughout the mission for both instruments. The results are remarkably similar for the two VIIRS instruments, including a slightly out-of-family behavior seen in a few detectors. We discuss possible causes for the difference and the impact on the aggregated Earth view images.

On-orbit↗

Assessment of VIIRS on-orbit polarization sensitivity and its impact on CLARREO pathfinder inter-calibration

The primary objective of the CLARREO Pathfinder (CPF) mission is to demonstrate essential measurement technologies to enable highly accurate decadal change observations traceable on-orbit to SI standards. Another important objective of the CPF is to demonstrate inter-calibration with the VIIRS sensor and to show that such high-accuracy reference inter-calibration is achievable. To satisfy this requirement, it is important to understand and quantify uncertainties in VIIRS sensor measurements. Based on prelaunch test results, the reflective solar bands of both SNPP and NOAA-20 VIIRS have exhibited polarization sensitivities in the shortest wavelength bands, with an unexpectedly larger sensitivity observed for NOAA-20 VIIRS, particularly in bands M1 to M4. In this study, we use VIIRS Level-1B reflectance data collected over the Pseudo-Invariant Calibration Sites over North African desert region to examine the polarization associated uncertainty for these four bands. Impact due to BRDF on the reflectance data is considered by comparing baseline results obtained from the same viewing and solar zenith angles under relatively low polarization sensitivity. Impact due to detector relative difference in polarization sensitivity is examined by normalizing reflectances by the value of the middle detector. Results of this study provide useful information on VIIRS uncertainty contribution due to polarization when conducting CPF and VIIRS inter-calibration.

VIIRS↗

An Overview of MODIS Calibration and Characterization and Lessons Learned

The Moderate Resolution Imaging Spectroradiometer (MODIS) is a key instrument for NASA's EOS missions. Two nearly identical copies have flown on the Terra and Aqua spacecraft for more than 9 years and 6 years since their launch in December 1999 and May 2002, respectively. MODIS observations and associated data products have been widely used by the science community and users worldwide for studies of Earth's system of land, oceans, and atmosphere. MODIS was developed based on the desire of the science community to extend and enhance heritage sensors' data records. It was designed with enhancements made over its heritage sensors in terms of its spectral, spatial, and radiometric characteristics. It is a cross-track scanning radiometer, that uses a two-sided scan mirror, collecting data in 36 spectral bands covering spectral regions of visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). The VIS, NIR, and SWIR bands (bands 1-19 and 26), which make measurements of daytime surface reflected radiances, are referred to as the reflective solar bands (RSB). The MWIR and LWIR bands (20-25 and 27-36), which measure both the daytime and nighttime scene emissive radiances, are thus referred to as the thermal emissive bands (TEB). In this paper, we provide an overview of MODIS instrument calibration and characterization methodologies, activities, and results from pre-launch to post launch, with emphasis on the lessons learned from its design to on-orbit operation. Currently, both instruments are operated normally and all the on-orbit calibration activities are performed on a regular basis with some at slightly reduced frequencies. The TEB responses have been extremely stable with less than 0.3% change per year. For the RSB, the changes are wavelength and scan angle dependent with the largest changes in the VIS spectral bands. As both Terra and Aqua MODIS continue to operate beyond their prime missions, constant effort is still needed to maintain instrument and calibration and data product quality. This paper shows that the lessons from Terra MODIS design, test, and operation, have greatly benefitted Aqua MODIS. Because of this, Aqua MODIS overall performance is better than Terra MODIS. It is not surprising that lessons from MODIS calibration and characterization, from methodologies to on-orbit implementation, have also provided valuable information for the design and development of future earth observing missions/sensors, such as VHRS on the NPP and NPOESS, ABI on GOES-R, OLI on LDCM, and the reflective solar sensor on CLARREO.

Xiong, Xiaxiong↗

MODIS Solar Diffuser Degradation Determination and Its Spectral Dependency

This study presents a modeling approach to improve solar diffuser (SD) degradation determination from SD stability monitor (SDSM) measurements. The MODIS instrument uses a SDto calibrate its reflective solar bands (RSBs) on-orbit. Due to the imperfectly designed SDSM sun view screen, the SD reflectance tracked by SDSM has large noise. The SDSM measurements noise is spectrally coherent and can be minimized by normalizing measurements to the least degradeddetector 9 (936 nm). In this study, a SD degradation model is used to determine the SDdegradation's wavelength dependency and the detector 9 degradation is estimated by the model solution.The results show the SD degradations measured at 6 SDSM detectors (554 _ 936 nm) have stable relationships, where the degradation is inversely proportion to 1/wavelength^4. The model estimated SD degradation at SDSM detector 9 wavelength (936 nm) is ~0.9% from 2002 to 2018.Based on the SD degradation model solution, the SD degradation at short/mid wave bands are estimated to improve short/mid wave bands calibration. The model can also be used to improve interpolating SD degradation at SDSM detectors to RSB wavelengths. Compared to linear interpolation, bands 9 and 10 show the largest differences of up to 0.3 and 0.4% respectively. These differences directly impact the calibration coefficients of these bands.

radiometric calibration↗

Comparison of Terra and Aqua MODIS VIS Bands On-Orbit Response

The Moderate Resolution Imaging Spectroradiometer (MODIS) has 36 spectral bands with a total of 490 detectors, covering spectral regions in the visible (VIS), near-infrared (NIR), short-wave infrared (SWIR), mid-wave infrared (MWIR), and long-wave infrared (LWIR). MODIS is a cross-track scanning radiometer which collects data using a rotating scan mirror (both sides) over a wide range of scan angles. The VIS, NIR, and SWIR bands (bands 1-19 and 26) make measurements of daytime surface reflected radiances, thus are referred to as the reflective solar bands (RSB). MODIS was built with a complete set of on-board calibrators, capable of providing radiometric, spatial, and spectral calibration and characterization during its entire mission. The RSB on-orbit calibration is primarily provided using a solar diffuser (SD) and a solar diffuser stability monitor (SDSM). The SD and SDSM calibration system is operated on a regular (weekly to bi-weekly) basis. The spectro-radiometric calibration assembly (SRCA) is another on-hoard calibrator that also provides RSB radiometric calibration support. For this purpose, the SRCA is operated in a radiometric mode on a monthly basis. A complete SRCA radiometric calibration is performed using different lamp configurations, or different radiance levels, to cover the range of RSB gain. Two additional SRCA modes with slightly different configurations are designed and operated for sensor on-orbit spectral and spatial characterization. In addition to its on-hoard calibrators, each MODIS makes monthly lunar observations to monitor RSB radiometric calibration stability. The MODIS lunar observations are made through its space view (SV) port at nearly the same lunar phase angles via spacecraft roll maneuvers. The SD, SRCA, and lunar measurements are made at different scan angles and data samples are collected for all spectral bands and detectors using both sides of the scan minor. Since launch, Terra and Aqua MODIS have operated successfully for more than 8 years and 6 years, respectively. Many SD/SDSM, SRCA, and lunar observations have been made by each instrument and used to derive RSB on-orbit calibration parameters, enabling corrections for sensor response changes and changes of the response versus scan angle (RVS). In general, the RSB calibration parameters are updated regularly into the MODIS Level 1B (LIB) code in support of continuous data processing for all MODIS science data products. This paper provides a brief description of MODIS RSB calibration methodologies and approaches, and summarizes on-orbit changes of their responses (gains), particularly for the VIS spectral bands.

Xiong, Xiaoxiong↗

Determination of the solar angular dependence of the NOAA-20 VIIRS solar diffuser BRDF change factor

When fully illuminated by the Sun, the solar diffuser (SD) onboard of the NOAA-20 Visible Infrared Imaging Radiometer Suite (VIIRS) instrument provides a radiance source to allow for radiometric calibration of the VIIRS’s reflective solar bands (RSBs). Once on-orbit, due to solar bombardment and the space environment, the SD’s bidirectional reflectance distribution function (BRDF) changes its value. The change is denoted by a factor, known as the H-factor, that is time and wavelength dependent, as well as both incident and out-going angle dependent. Here, we use regular on-orbit solar diffuser stability monitor (SDSM) data to determine the solar angular dependence for the H-factor along the SD-to-SDSM direction. We compare the dependence with that for the VIIRS on the Suomi National Polar-orbiting Partnership satellite and apply the dependence ratio to obtain the N20 VIIRS SD H-factor along the SD-telescope direction.

N20 VIIRS↗

Improvements in the on-orbit response versus scan-angle characterization for the MODIS ocean color bands

On-orbit characterization of the response versus scan-angle (RVS) is one of the most challenging aspects of the reflective solar band (RSB) calibration for the MODIS instruments onboard the Terra and Aqua spacecraft. The degradation of the solar diffuser, together with the lack of onboard calibrators (OBCs) to cover additional scan angles, other than the one for the lunar observations, has resulted in the use of Earth view responses from the pseudo-invariant desert sites to track the on-orbit RVS changes. This approach has been implemented in Collection 6 (C6) and C6.1 for bands 1-4, 8 and 9 of both instruments and also band 10 of Terra MODIS. As the missions continue to operate over a decade beyond their designed life and the instrument optics continue to degrade, it is expected that the OBC based RVS currently applied to other bands, specifically the high-gain ocean bands, will be inadequate to maintain the long-term calibration stability. An interband calibration approach is formulated and implemented in this paper. The proposed approach relies on the use of a spectrally matching stable reference band to evaluate the long-term calibration stability of the high-gain ocean bands that typically saturate while viewing the selected calibration deserts. Results from this approach indicate a noticeable drift for Terra MODIS bands 11 and 12 whereas the Aqua bands continue to show excellent temporal stability. These results are consistent with the corrections derived by the NASA Ocean Biology Processing Group (OBPG) and are expected to have minimum impacts on the downstream science products.

MODIS↗

Applications and Results of MODIS Lunar Observations

Both Terra and Aqua MODIS have been making periodic lunar observations since their launch in December 1999 and May 2002, respectively. The primary objective of the MODIS lunar observations is to monitor on-orbit response changes for the reflective solar bands (RSB) and to track long-term radiometric calibration stability. The Moon is an extremely stable surface reflectance reference and, together with the lunar radiometric model developed recently by the US Geological Survey (USGS), the applications of lunar observations for Earth remote sensing missions have been greatly enhanced and expanded. In particular, calibration inter-comparisons among sensors on different platforms and operated in different time frames have been enabled in the VIS/NIR/SWIR spectral regions. In this paper, we discuss various applications of MODIS lunar observations, such as monitoring the RSB radiometric stability and calibration consistency between the two sensors, evaluating the calibration differences among detectors within the same spectral band, and tracking the on-orbit changes of band-to-band registration (BBR). Other applications designed for the thermal emissive bands (TEB) and special sensor characterization purposes are also illustrated. Results from multi-year Terra and Aqua MODIS lunar observations demonstrate clearly that the two sensors have been calibrated consistently to within 1% for most RSB compared to the 2% radiometric calibration requirement. In addition the spatial characterization results derived from lunar observations are in good agreement with those derived from the instrument's on-board calibrator. The applications and results of MODIS lunar observations presented in this paper provide useful references for other sensors that also make use of lunar surface observations.

Xiong, X.↗