Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resource Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Data Analytics Methods to Measure Plant Outage Resilience

Every 18 or 24 months nuclear power plants (depending on plant configuration, pressurized or boiling water reactor respectively) undergo a period of outage where the plant is taken offline and a large number of maintenance and surveillance activities (that cannot be performed while plant is running) are performed in typically 2–3 weeks. Planning of a plant outage is very challenging since all the activities are required to be performed in the shortest amount of time given available resources (typically contractor crews hired for the duration of the outage). Consequently, plant outages can be costly due the actual loss of power generation and crew costs and, because of it, there is a need to maximize resource usage in the outage planning phase and reduce the risk of outage delays. This paper is addressing these needs by providing a set of analytical methods designed to analyze plant outage schedule and identify critical elements based on available resources (time and crews). These methods are based on natural language processing and optimization algorithms. In this respect, two classes of methods have been developed: one that focuses on the time resource and how variability in the time to complete outage tasks may impact outage delays, and one that minimizes the risk of outage delays by integrating available resources to assess when daily activities should be performed.

97 - MATHEMATICS AND COMPUTING↗

An Architectural Survey of the U12G Tunnel Historic District, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to demolish six buildings and three storage areas located at the U12g Tunnel portal area in Area 12 of the Nevada National Security Site (NNSS). The buildings are 12-358 (Signal Vault); 12-201800 (Storage Quonset Hut); 12-202555 (Walker Shack); 12-868 (Pipe Assembly); 12-B100933 (Electrical Shop); 12-B100944 (Conference Room); and Storage Area 1; Storage Area 2; and Storage Area 3. The buildings and storage areas were selected for demolition as part of the DOE’s Real Property Efficiency Plan to reduce the footprint of unused and non-operational facilities on the NNSS. They are all vacant and have no proposed uses for current or upcoming NNSS missions. Demolition activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800. Identification efforts began with resources proposed for demolition in federal Fiscal Year (FY) 23. Four buildings were proposed to be demolished in FY23 (12-358, 12-868, 12-201800, and 12-202555). These buildings and the U12g Tunnel Historic District (SHPO No. D444) were recorded in Identification, Evaluation, and Finding of Adverse Effect for the Proposed Demolition of Five Buildings in Area 12, Nevada National Security Site, Nye County, Nevada (Menocal et al. 2023). Identification efforts indicated three buildings (12-358, 12-201800, and 12-868) supported nuclear testing in the U12g Tunnel. The fourth building post-dated the use of U12g Tunnel for nuclear testing activities. The report recommended that three of the four buildings (12-358, 12-201800, 12-868) and the U12g Tunnel Historic District may be eligible for the National Register of Historic Places (NRHP). The report also found that the undertaking would have an adverse effect on the three buildings and on the historic district. The Nevada State Historic Preservation Office (SHPO) concurred with the report’s findings (Reed 2023). The U12g Tunnel was determined eligible as a historic district under the Secretary of the Interior’s (SOI) Significance Criterion A, at the local level, in the context of the Cold War as an underground testing environment for the development of nuclear weapons and to assess the effects of a nuclear explosion on materials and equipment with a period of significance from 1959 to 1971. It was also determined eligible under Significance Criterion C for embodying the distinctive characters of a horizontal tunnel complex used for nuclear testing and as a significant and distinguishable entity. The three buildings were determined to be contributing elements of the district. The undertaking was expanded with the addition of two buildings and three storage areas proposed to be demolished and located within U12g Tunnel Historic District in FY24. These five resources (12-B100933, 12-B100944, and Storage Areas 1, 2, and 3) were recorded in Supplemental Identification, Evaluation, and Finding of Effect for Additional Proposed Demolition at U12g Tunnel, Area 12, Nevada national Security Site, Nye County, Nevada (Brannan et al. 2024). Identification efforts indicated that the two buildings and Storage Area 1 supported nuclear testing in the U12g Tunnel. Storage Area 1 and Storage Area 2 post-dated the nuclear testing activities at U12g Tunnel and were not recommended as contributing elements to the district. The report also found that the undertaking would have an adverse effect on the newly identified buildings and one storage area and on the historic district. The SHPO concurred that the expanded undertaking would result in adverse effects to historic properties (Reed 2025). To resolve these adverse effects, NNSA/NFO, in consultation with the SHPO, is following standard mitigation as stipulated in the 2024 Programmatic Agreement DE-GM58-22NA25554 Among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (hereafter referred to as the NNSS PA). The standard mitigation measures are outlined in Appendix D of the NNSS PA. As such, this architectural survey has been prepared in accordance with Appendix D of the NNSS PA and follows the report format outlined in Appendix F. It includes a historic context that describes the district’s origin, history, and support functions, its significance in the context of nuclear testing on the NNSS, and identifies contributing and non-contributing elements within the district. The report is accompanied by Architectural Resource Assessment (ARA) forms for individual resources and a Historic District Resource Assessment (HDRA) for the U12g Tunnel Historic District. In total, this architectural report identified 32 primary resources within the district boundary. Six of the primary resources were previously identified as contributing elements. An additional 17 resources are recommended as contributing elements to the district for a total of 23 contributing elements. The other nine resources identified are recommended as non-contributing elements to the district.

12-201800↗

Empirical Assessment of Interregional Coordination to Support Resource Adequacy [Slides]

This study examines where interregional transmission could most effectively support resource adequacy in the contiguous United States. We use hourly load, renewable generation, and real-time price data from 2016–2023 for 18 planning subregions to identify periods of elevated adequacy risk, defined as the top 100 annual hours of net load and wholesale prices in each region. We then measure the temporal coincidence of these peak periods between adjacent regions and compare price patterns to assess the potential for capacity sharing. Results show that NorthernGrid West, a winter-peaking region, has low coincidence of peak net load with its summer-peaking neighbors, indicating high potential for interregional support. In contrast, regions in the Northeast have highly coincident peak periods, suggesting limited adequacy benefits from additional transmission. Price-based analysis shows peak-hour differences in the Midwest and between ERCOT and neighboring regions, indicating potential economic benefits from increased transfers. The findings provide an empirical screening of where transmission may offer the greatest reliability benefits without adding new generation capacity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Deliverable 6.7-Final Technical Report: Development Summary and Evaluation of the Solar Uncertainty Integrator (SUNI) Software

The Data Quality and Uncertainty Integration Project was a three-year effort to address stakeholder needs for assessing solar radiation resource data quality based on existing tools for estimating radiometer measurement uncertainties and assessing post-measurement data quality. The annual research objectives for the project addressed a logical progression of effort needed to achieve the ultimate project goal of developing the Solar Uncertainty Integrator (SUNI) software. This final technical report summarizes the development process for achieving these key research objectives and addresses the outreach and code development efforts in the final year of the project to develop a new solar irradiance data uncertainty integration software package.

14 SOLAR ENERGY↗

Simple Wins: Driving Effective Implementation of Energy Efficiency Projects

Small- and medium-sized manufacturers (SMMs) in the United States, making up over 98% of manufacturing firms, account for 48.3% of the sector’s energy consumption. Despite access to energy assessments and technical resources, such as those from the US Department of Energy’s Better Plants program and Industrial Training and Assessment Centers, implementation rates for identified energy-saving measures remain lower than expectations, averaging 47%. Some barriers were identified by other researchers as limited workforce capacity, inadequate training, and time constraints hinder progress. This article studied the development of customized checklists together with the energy assessment report as a practical solution to improve implementation rates for energy efficiency projects among SMMs. The framework for the checklists was grounded in five principles: short, precise, actionable, relevant, and codeveloped (SPARC). A case study of a 500,000-squarefoot SMM demonstrates how tailored checklists targeting significant energy users—such as heating, ventilating and air conditioning (HVAC), lighting, and compressed air systems for this facility—can simplify the process for staff to do facility walkthroughs to monitor best practices and track the progress of energy efficiency project implementation.

Guo, Wei [Oak Ridge National Laboratory (ORNL), Oa↗

Carbon Transport and Storage Planning and Viability Support Tools

The EDX disCO2ver Carbon Transport and Storage Planning and Viability Support Tools are made up of the Carbon Storage Planning Inquiry Tool (CS PlanIT, Justman et al. 2024) and the Carbon Storage Technical Viability Approach Support Tool (CS TVA). Together, these tools support data access to support understanding data availability to support planning efforts for carbon transport and storage. The Carbon Storage Planning Inquiry Tool (CS PlanIT) is an online web mapping application designed to help users explore, query, and evaluate multiple data layers to support and accelerate carbon storage resource and feasibility assessments and planning efforts. CS PlanIT currently contains a range of datasets associated with geologic, technical, and infrastructure factors. The data sets can be filtered geographically for an area of interest to update statistics and charts within the dashboard. The dashboard is divided into different sections called widgets, relating to different steps in the carbon storage planning process. The resources in this submission include a link to PlanIT, as well as a data catalog and link to user documentation. The original citation for the CS PlanIT tool, which has now been integrated into the toolset here, was: - Devin Justman, Scott Pantaleone, Maneesh Sharma, Lucy Romeo, Paige Morkner, CS PlanIT (Carbon Storage Planning Inquiry Tool) , 6/28/2024, https://edx.netl.doe.gov/dataset/cs-planit-carbon-storage-planning-inquiry-tool, DOI: 10.18141/2377953 The Carbon Storage Technical Viability Approach Support (CS TVA) Tool displays spatial data availability for the many components of Geologic Carbon Storage (GCS) technical viability assessment (Creason al 2025). Identifying sites suitable for GCS requires evaluating the intersection of myriad factors, including reservoir conditions, subsurface and surface hazards, infrastructure requirements, and energy community metrics. The technical viability of a site can only be confirmed for instances where all these factors have data available, and where those data support viability. Additional Resources related to the Technical Viability Assessment Tool: - Julia Mulhern, Casey White, Araceli Lara, Neyda Cordero Rodriguez, Zachary Jackson, Jacob Shay, Gabriel Creason, MacKenzie Mark-Moser, Paige Morkner, Kelly Rose, Carbon Storage Technical Viability Approach (CS TVA) Database, 3/26/2025, https://edx.netl.doe.gov/dataset/edx4ccs-carbon-storage-technical-viability-approach-database , DOI:10.18141/1984655 - Julia Mulhern, MacKenzie Mark-Moser, Gabriel Creason, Casey White, Araceli Lara, Neyda Cordero Rodriguez, Zach Jackson, Paige Morkner, Kelly Rose, Carbon Storage Technical Viability Approach (CS TVA) Matrix, 3/27/2025, https://edx.netl.doe.gov/dataset/carbon-storage-technical-viability-approach-cs-tva-matrix , DOI: 10.18141/2539979 - Gabriel Creason, Zach Jackson, Neyda Cordero Rodriguez, Julia Mulhern, Casey White, Araceli Lara, MacKenzie Mark-Moser, Paige Morkner, Kelly Rose, Carbon Storage Technical Viability Approach (CS TVA) Data Availability Results Database, 3/27/2025, https://edx.netl.doe.gov/dataset/carbon-storage-technical-viability-approach-cs-tva-data-availability-results-database, DOI:10.18141/2538557

Carbon storage↗

A Refined Method to Translate Solar Data Quality Assessment Flags to Estimated Measurement Uncertainty

Integrating solar resource uncertainties due to radiometer measurement performance and operational data quality assessment can provide improved estimates of economic bankability, system design performance, and compliance of solar energy conversion systems. Estimating radiometer measurement uncertainty is an established procedure consistent with recognized best practices and international guidelines. SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report, the fourth of six for the Data Quality and Uncertainty Integration Project, presents a refined algorithm description for software to translate solar resource data quality assessment results into estimated uncertainty values in a Solar Resource Operational Uncertainty Integrator (SROUI) application. This algorithm requires three-component solar irradiance measurements - global horizontal irradiance, direct normal irradiance, and diffuse horizontal irradiance - collected at 1- to 60-minute intervals, as described in the previous deliverables. The development of this report as Deliverable 6.4 was an iterative process that included reviews and feedback from the project team on initial drafts designed to refine how the new software could best support determining solar resource data uncertainty. The results of this effort will contribute to the final software system development by National Renewable Energy Laboratory staff.

14 SOLAR ENERGY↗

CARILEC Resilient Energy Community CoP for Cybersecurity Workshop Series: Cybersecurity Assessment Tools [Slides]

For the last several years and in collaboration with CARILEC, USAID and NREL have been working to support cyber resilience at power sector utilities in Latin America and the Caribbean. Direct technical assistance with regional utilities has been a key component of USAID-NREL Partnership activities, and technical assistance has typically included a foundational cybersecurity assessment using NREL's Distributed Energy Resource Cybersecurity Framework (DER-CF) tool. The DER-CF allows organizations to benchmark and evaluate their cybersecurity posture across the areas of Governance, Technical Management, and Physical Security. To complement the activities of the newly created CAREC IT/OT and Cybersecurity Team, this webinar on cybersecurity assessment tools includes an overview of the DER-CF tool and a discussion with regional stakeholders and NREL experts on the DER-CF assessment process and other resources for cybersecurity assessments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The National Climate Data Base (NCDB): A Bias-Corrected High-Resolution Climate Dataset

Assessing renewable energy resources under future climate scenarios has been highlighted in recent years to analyze and understand potential impacts of future change in renewable generation on the power sector. Solar energy is well-known as the most plentiful among various renewable resources and usually converted to electricity using photovoltaics (PV) technologies, and the global deployment of PV technology has increased rapidly in recent decades. In this study, we develop a statistical technique to downscale the future projection of solar irradiance for PV energy-related applications. A set of Regional Climate Model (RCM)-based projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) are used as inputs to statistical methods to generate high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). The main steps of the statistical downscaling method include (1) regridding RCM output (0.22 degree and daily resolutions) to handle the modeled-observed data sets on a common grid, (2) correcting bias of RCM GHI using satellite-derived observation, and (3) implementing temporal and spatial downscaling to generate GHI at 8-km and hourly resolution. Basically, complex physical processes and interactions between solar radiation and various atmospheric constituents lead solar irradiance to be highly variable and uncertain. Underrepresentation of clouds from the RCM parameterizations is the main source of error and uncertainty in modeling solar irradiance. Thus, we adapt and use the high-quality satellite-derived data from the National Solar Radiation Database (NSRDB) to analyze the bias and error of RCM GHI as well as estimate the statistical parameters for spatial and temporal downscaling. This presentation will summarize the comprehensive analysis conducted to produce and assess the results under two climate scenarios (RCP4.5 and RCP8.5). We will also present a detailed validation demonstrating the strengths of the proposed downscaling method and future extension of this research.

climate data↗

Assessment of Climate Change Impacts on Renewable Energy Resources in Western North America

We examine a 25 km resolution climate model dataset to evaluate how regional climate change impacts solar and wind energy under a high-emission scenario. Our study considers the Western Electricity Coordinating Council (WECC) region, which covers the western United States and southwestern Canada, focusing specifically on locations with existing solar and wind infrastructure. First, we conduct a historical model comparison of solar and wind energy capacity factors to highlight model uncertainties across the study area. Using future climate projections, we then assess the seasonal patterns of solar and wind capacity factors for three timeframes: historical, mid-century, and end of century. Additionally, we estimate the frequency of solar and wind resource droughts during these periods for the entire WECC and its five operational subregions, finding that certain subregions are more susceptible to energy droughts due to limited renewable resources. Finally, we present day-ahead capacity factor forecasts to support energy storage planning and provide estimates of offshore wind energy capacity within the WECC. Our results indicate that offshore wind capacity factors are nearly twice as high as onshore values, with less seasonal variation, which suggests that offshore wind could offer a more consistent renewable energy supply in the future.

climate change↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Ecologically inspired metrics for transitioning to a sustainable and resilient circular economy with application to multilayer plastic films

Current Circular Economy (CE) frameworks applied to product chains exhibit notable shortcomings. These include neglecting the resilience and robustness of design, requiring detailed economic and environmental data for impact assessment, and relying on qualitative rather than quantitative metrics capturing certain CE design aspects. In the current contribution, we addressed these shortcomings by developing an Ecologically inspired (Eco-inspired) Framework using the mathematical foundations of Ecological Network Analysis (ENA). While ENA metrics have previously found application in designing circular economies, particularly in Industrial Symbiosis (IS) networks, our adaptation tailors these metrics for use in product-level CE, recognizing the inherent distinctions between product-level CE and IS. Our Eco-inspired Framework comprises three key categories to provide holistic and granular-level metrics for designing product-level CE. The first set of metrics assesses circularity and resource efficiency. The second set gauges network intensity and robustness as complementary indicators ensuring a CE is both sustainable and resilient. The third group of metrics evaluates enhancement potential of CE strategies through introducing quantitative metrics for measuring the degree of closed-loop strategies and average circularity level of a CE design. The three comprehensive set of indicators within the Eco-inspired Framework uniquely captures various facets of circular design, whether originating from technological innovations and recovery improvement at the end of life (EoL), shifts in human consumption patterns, alterations in product design, or changes in business models. The framework’s application is tested in designing a CE for multilayer Polyethylene-Polyamide (PE-PA) films. Using the Eco-inspired Framework, we identified the best strategy for designing a resilient and sustainable CE for PE-PA films. A diverse set of EoL strategies along with a reduction in product consumption can improve circularity and resilience by 650% and 255%, respectively, and mitigate greenhouse gas emissions by 90%. The framework minimizes trade-offs between sustainability and circularity goals and offers insights on how to enhance each strategy for achieving a resilient and sustainable CE for products.

54 ENVIRONMENTAL SCIENCES↗

Bias Correction and Statistical Downscaling of Future Solar Irradiance Projections Using the NSRDB

Assessing renewable energy resources under future climate scenarios has been highlighted to understand potential impacts of future climate change in renewable generation on the power sector. Climate model projection has been recognized by the renewable energy community as a useful data set to analyze the impacts of future climate change on renewable resources. However, future climate projections generated from general circulation models (GCMs) contain inherent biases that need to be corrected for accurate analysis of future projections of climate variables. In addition, the coarse spatiotemporal resolution of GCMs needs to be improved for regional climate studies. In this work, we develop statistical methods to downscale future projections of global horizontal irradiance (GHI) in a computationally efficient way. Our approach builds statistical downscaling models that correct bias of climate projection of GHI and downscale the future GHI projection from daily-scale to hourly-scale. The National Solar Radiation Database (NSRDB) is used to calibrate the statistical models and validate the downscaled GHI projections across the contiguous United State (CONUS). Preliminary results show that the statistical approach efficiently downscales climate projections of GHI with a nBIAS of 3%, nMAE of 34 % and nRMSE of 46% calculated against NSRDB for CONUS. This study describes the implemented methodology and initial results as well as future research to create high-resolution climate data sets for solar energy applications.

analytical models↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2023

Pacific Northwest National Laboratory (PNNL), one of the U.S. Department of Energy (DOE) Office of Science’s 10 national laboratories, provides innovative science and technology development in the areas of energy and the environment, fundamental and computational science, and national security. There are three DOE offices within the Richland area. Two are responsible for the Hanford Site, whereas the Pacific Northwest Site Office oversees PNNL. PNNL prepares an Annual Site Environmental Report to meet the requirements of DOE Order 231.1B, Environment, Safety and Health Reporting, and DOE Order 458.1, Radiation Protection of the Public and the Environment, thus assuring that the public is informed of any PNNL-Richland campus or PNNL-Sequim campus event that could adversely affect the health and safety of the public, site staff, or the environment. The report provides a synopsis of ongoing environmental management performance and compliance activities for operations that occur at the PNNL-Richland campus in Richland, Washington, and at the PNNL-Sequim campus near Sequim, Washington. It describes the location of and background for each facility; addresses compliance with applicable DOE, federal, state, and local regulations, and site-specific permits; documents environmental monitoring efforts and their status; presents potential radiation doses to staff and the public in the surrounding areas; and describes DOE-required data quality assurance methods used for data verification. The ASER report describes Compliance with Federal, State, and Local Laws and Regulations in 2023, Environmental Sustainability, Environmental monitoring and dose assessment, Natural and Cultural Resource Management, and Quality Assurance activities that took place during Calendar Year 2023.

40 CFR 61 Subpart H↗

Geothermal Power Systems Analysis: Outcome of Industry Stakeholders Workshop

Geothermal cost and performance evaluation implemented via techno-economic assessment (TEA) modeling is critical for the U.S. Department of Energy (DOE) and other geothermal industry stakeholders in assessing the current state of geothermal technologies and to identify existing hurdles to commercially viable geothermal development. The Geothermal Electricity Technology Evaluation Model (GETEM) is a major TEA tool used in estimating the economic feasibility and levelized cost of energy (LCOE) of conventional hydrothermal systems and enhanced geothermal systems (EGS). Since 2021, GETEM has been transitioning from an intricate spreadsheet model to a user-friendly tool within the System Advisor Model (SAM) developed by the National Renewable Energy Laboratory (NREL). Apart from enabling an expanded visibility of the geothermal model among other renewable resources, having GETEM in SAM has the advantage of simulation automation, better usability, updates tracking, active user inputs/feedback, and extended financial modeling. GETEM is used in developing supply curves for NREL's Annual Technology Baseline (ATB), which provides inputs to the Renewable Energy Potential (reV) and the Regional Energy Deployment System (ReEDS) models. The geothermal module in NREL's reV model assesses the geothermal energy potential in the conterminous United States by defining the geospatial intersection of geothermal resources with existing grid infrastructure within the constraint of land use characteristics. The ReEDS model is a capacity expansion model used for simulating the long-term build-out and operation of the U.S. generation and transmission system based on current energy costs and policies. To ensure enhanced representation of current industry trends in our model transitions and development, we organized a two-day virtual workshop to elicit geothermal industry stakeholder input and recommendations on our current approaches and assumptions on techno-economic, resource assessment, and deployment scenarios modeling of geothermal technologies. Participants included developers, operators, investors, regulatory agencies, system modelers, national laboratory researchers, consultants, and other stakeholders. In this workshop, we gained stakeholder insights on current geothermal plant performance (i.e., capacity factors), updated drilling costs and learning curves, and next-generation technologies such as closed-loop and superhot rock geothermal. Other outcomes from this workshop and its impact on future geothermal development feasibility, resource availability, and capacity expansion studies are compiled and discussed.

annual technology baseline↗