Search NASASearch

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data

Characterization of SimulCam, a standoff Raman system for scientific support of SuperCam operations on Mars

During the development activities of SuperCam Calibration Target, target intended for one of the two first Raman instruments to be deployed on another planetary body, our group developed a laboratory instrument that could simulate to some extent the Raman capabilities of one of such instruments and could provide data with similar quality. The use of this kind of laboratory instruments has demonstrated its utility in the evaluation of potential calibration targets or anticipating the science outcome that an instrument could provide. The present work describes our laboratory setup to support SuperCam, evaluating similarities between both instruments, despite of differences in the hardware. Evaluation of data gathered by SuperCam on Mars and the availability of one replica of SuperCam’s Calibration Target allowed the comparison on the same set of targets, demonstrating how similar Signal-to-Noise Ratio (SNR) could be achieved from both instruments. The higher energy per pulse on SimulCam is compensated by a greater analytical footprint and the use of smaller collection optics. The results show how spectra obtained at representative distances of SuperCam are comparable. Operational principles are also comparable in terms of time resolution, and close in terms of spectral resolution. This similarity has allowed different science support works using SimulCam data, as well as the support to Mars detections using our setup. We provide examples of this support that will be shared with the community in different papers, as well as examples of possible operations activities that could benefit from experiments performed with SimulCam. We show how this setup can complement the two laboratory replicas in Los Alamos and Toulouse in providing support data to different experiments.

47 OTHER INSTRUMENTATION

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations

The upgraded summing NaI(Tl) (SuN++) absorption spectrometer

Simulations of astrophysical processes require a plethora of nuclear physics input. In particular, models of neutron-capture nucleosynthesis like the s, i, and r processes require β-decay information and experimentally constrained neutron-capture reaction rates. Past experiments with the 4π Summing NaI(Tl) (SuN) total absorption spectrometer have provided these physics quantities. Here, we outline an upgrade of SuN to SuN++, where 20 new segments (12 NaI(Tl) and 8 CeBr 3 ) have been integrated into the pre-existing SuN total absorption spectrometer to provide increased energy and time resolution in β-decay experiments. The details of the newly upgraded SuN++ total absorption spectrometer are discussed with results from the commissioning experiment at the Facility for Rare Isotope Beams (FRIB) utilizing a 70 Cu beam.

CeBr3

All hard X-ray transient grating spectroscopy

Optical-domain transient grating (TG) spectroscopy is the ideal tool to investigate transport phenomena in gases, liquids and solids, but it is limited to typically micron-size grating periods. Extreme-Ultraviolet TG has represented a major leap forward to access the mesoscopic scales. Hard X-ray TGs open access in principle to the nanoscale. Hard X-ray TGs were recently generated using the Talbot effect and probed by optical pulses, but these hinder exploiting the advantages of the nanoscale gratings. Here, we present an all-X-ray TG study, in which few-femtosecond hard X-ray pulses are used both for excitation and probing. Our experiment was performed on an amorphous film of an FeGd alloy and on a thin silicon single crystal. The results show a manifestation of the TG induced by the X-ray pump and probe pulses in the form of Talbot carpets, as well as temporal evolution of the grating in crystalline silicon showing coherent optical phonons. Ultrafast all-X-ray TG spectroscopy has the potential to study fundamental excitations with femtosecond time resolution and nanometer spatial sensitivity.

Ferrari, Eugenio [Deutsches Elektronen-Synchrotron

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION

Excellent Timing Cherenkov Light Detection for Dual-readout High-granularity Calorimetry

We are developing a Cherenkov detector aiming for applications in the next-generation calorimetry. It is a calorimetry that combines dual-readout and high-granularity with excellent timing capability. This work is to prove the concept of the Cherenkov detector utilizing a resistive plate chamber (RPC) with Diamond-Like Carbon as resistive electrode. The first prototype was tested with β-rays and cosmic-rays. This paper discusses the behavior of the charge spectrum and the time resolution of the first prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Structure and ultrafast dynamics of tri-nuclear Ag-/Tl–Pt 2 POP 4 complexes in solution

The energetics and dynamics of ion assembly in solution has broad influence in nanomaterials and inorganic synthesis. To investigate the fundamental processes involved, we present a time-resolved x-ray solution scattering (TR-XSS) study of the trinuclear silver and thallium complexes of the diplatinum ion PtPOP [Pt 2 (H 2 P 2 O 5 )$_4^{4−}$] in aqueous solution. These complexes, their structural properties, and their electronic structure are not well understood and afford a unique opportunity to study the metal–metal bond formation that influences molecular and material assembly in solution. We present model-independent analysis of the observed dynamics as well as an analysis incorporating time-resolved structural refinements of key bond lengths with $<$100 fs time resolution. We find that upon photoexcitation, the Pt atoms contract ∼0.25 Å toward the center of both the Ag- and the Tl-PtPOP complexes, as previously observed for the PtPOP anion. For the AgPtPOP system, an ultrafast Ag-Pt bond expansion of ∼0.2 Å is observed, whereas in contrast, the TlPtPOP system exhibits a Tl-Pt bond contraction of ∼0.3 Å upon photoexcitation. For both complexes, the change in electronic state leads to coherent (“wave-packet”) oscillations along the metal–Pt coordinates. Based on these structural dynamics, we propose an electronic structure model that describes the metal–metal bonding behavior in both the ground and excited state for both complexes.

Lenzen, Philipp [Technical Univ. of Denmark, Lyngb

Wehnelt photoemission in an ultrafast electron microscope: Stability and usability

We tested and compared the stability and usability of three different cathode materials and configurations in a thermionic-based ultrafast electron microscope: (1) on-axis thermionic and photoemission from a custom 100 μm diameter LaB 6 source with a graphite guard ring, (2) off-axis photoemission from the Ni aperture surface of the Wehnelt electrode, and (3) on-axis thermionic and photoemission from a custom 200 μm diameter polycrystalline Ta source. For each cathode type and configuration, including the Ni Wehnelt aperture, we illustrate how the photoelectron beam-current stability is deleteriously impacted by simultaneous cooling of the source following thermionic heating. Furthermore, we demonstrate usability via collection of parallel- and convergent-beam electron diffraction patterns and by formation of the optimum probe size. We find that usability of the off-axis Ni Wehnelt-aperture photoemission is at least comparable to on-axis LaB 6 thermionic emission, as well as to on-axis photoemission [the heretofore conventional approach to ultrafast electron microscopy (UEM) in thermionic-based instruments]. However, the stability and achievable beam currents for off-axis photoemission from the Wehnelt aperture were superior to that of the other cathode types and configurations, regardless of the electron-emission mechanism. Beam-current stability for this configuration was found to be ±1% (one standard deviation from the mean) for 70 min (longest duration tested), and steady-state beam current was reached within the sampling-time resolution used here (~1 s) for 15 pA beam currents (i.e., 460 electrons per packet for a 200 kHz repetition rate). Repeatability and robustness of the steady-state condition were also found to be within ±1% of the mean. We discuss the implications of these findings for UEM imaging and diffraction experiments, for pulsed-beam damage measurements, and for practical switching between optimum conventional TEM and UEM operation within the same instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION

Investigating the ultraviolet photodissociation of bromocyclopropane with ultrafast electron diffraction

We have studied the photodissociation of gas-phase bromocyclopropane by 200 nm wavelength ultraviolet radiation using ultrafast electron diffraction. Bromocyclopropane is a prototypical molecule in the study of organobromides, a class of molecules that have a significant impact on atmospheric ozone depletion through their photochemistry. Here, previous studies have revealed two possible reaction pathways for the photodissociation of bromine from bromocyclopropane; either the C–Br bond dissociates, leaving behind a cyclopropyl ring, or there is a concerted opening of the cyclopropyl ring along with the C–Br bond dissociation. In this work, both our experimental and simulation results indicate that the majority of the UV-photoexcited BCP molecules (88% ± 11% in the experiment) follow the first reaction pathway, in which the cyclopropyl ring remains closed after homolytic C–Br bond cleavage. This direct bond dissociation occurs within the experimental time resolution of 270 fs. In order to differentiate between the possible reaction end-products, both of which have diffraction signals dominated by the bromine atom, a new analysis method has been employed, which is more sensitive to the structure of the end-products.

Atmospheric chemistry

Real-time observation of toroidal current redistributions induced by three-dimensional MHD phenomena triggering vertical displacement events in tokamak plasmas

Three-dimensional MHD instabilities, including edge-localized modes (ELMs) and internal reconnection events (IREs), have been observed to precipitate loss of vertical stability in tokamak plasmas, resulting in vertical displacement events (VDEs). This vertical destabilization can occur due to toroidal current redistributions and/or shape changes resulting from these phenomena. Using a recently introduced method for rapidly reconstructing the two-dimensional toroidal plasma current density profile in real-time, results are presented that demonstrate the specific current distribution changes that occur during ELMs (on KSTAR) and IREs (on MAST-U) that lead to loss of vertical control. The method most efficiently reconstructs the toroidal current density profile by doing so on a basis of principal components of historical profiles. These principal components isolate dominant current profile dynamics, improving interpretability, increasing speed, and reducing dimensionality of the profile computation. On KSTAR, this computation is executed in the real-time plasma control system at a rate of 10 kHz (limited by available CPU cycle times), allowing the current profile evolution to be assessed at several times over the course of each ELM event. Further, by incorporating the reconstructions into a novel vertical stability metric, the contribution of specific current profile dynamics to the loss of vertical stability can be assessed in real-time for VDE avoidance and improved understanding of the causal relationship between three-dimensional MHD phenomena and VDEs. The success of this method in approximating toroidal current density profiles from kinetic equilibrium reconstructions is also presented ($R^2=0.990$), along with its capability to produce other equilibrium quantities of interest in real-time at high time resolution.

edge-localized modes

Investigation of pedestal parameters and divertor heat fluxes in small ELM regimes in DIII-D

Abstract Divertor heat flux and its correlation with pedestal parameters within various small edge localized mode (ELM) regimes, including high beta poloidal, type-II and ELMs with negative triangularity H-modes were investigated in DIII-D. The parallel energy fluences of type-II and high beta poloidal small ELM regimes fall below the linear scaling with pedestal electron pressure for type-I ELMs put forward in Eich et al 2017 ( Nucl. Mater. Energy 12 84–90). The negative triangularity of H-mode ELMs follow the Eich scaling for type-I ELMs. The parallel heat flux and total heat loads to the divertor were determined using high-time resolution infrared thermography, while pedestal parameters were obtained through self-consistent kinetic equilibrium reconstructions. Linear regressions for the type-II and high beta poloidal regimes demonstrate that an equivalent 7.5 MA small ELM scenario in ITER would fall below the ~5 MJ m − 2 leading edge melting limit for tungsten (Gunn et al 2017 Nucl. Fusion 57 046025). Utilizing fast thermography, the scrape-off layer power fall-off length for both inter-ELM and intra-ELM was determined and compared to the Eich scaling with poloidal magnetic field in Eich et al (ASDEX Upgrade Team and JET EFDA Contributors 2013 Nucl. Fusion 53 093031). Except for the high beta poloidal scenario, all the small ELM regimes during both inter- and intra-ELM periods had power fall-off lengths ( λ q ) larger then would be expected from the B pol , MP − 1 scaling associated with type-I ELMs, signifying their potential in managing heat loads and offering a solution for core–edge integration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Characterizing core and edge turbulence regimes with fluctuation imaging diagnostics in Wendelstein 7-X

Two density fluctuation imaging systems, phase contrast imaging (PCI) and gas puff imaging (GPI) measure spatially resolved density fluctuations with high time resolution throughout the core plasma (PCI) and in the scrape-off layer (GPI) of the Wendelstein 7-X (W7-X) stellarator. Both systems combined give a comprehensive overview of overall fluctuation levels, spectral properties such as their distribution in frequency and wavenumber space as well as their spatial distribution. These tools are used to assess changes in density turbulence in three representative discharges that transition into stable divertor detachment by different strategies (impurity seeding, density ramping and power starvation). Several general trends are identified when the radiated power fraction is systematically increased: In the plasma edge, the line emission observed by GPI shifts radially inward with a drop in electron temperature, and normalized intensity fluctuation profiles follow this inward shift. Skewness and kurtosis of these edge fluctuations are reduced, indicating a reduction of large intermittent transport events, and poloidal phase velocities decrease in magnitude. These observations are consistent with a reduced power input into the plasma edge and a general reduction of turbulent activity. Core density fluctuation levels remain nearly constant in the impurity seeding scenario, indicating that detachment does not significantly impact turbulence there. However, a strong reduction in the dominant outboard fluctuation phase velocity is observed that deviates from the previous interpretation of neoclassical radial electric field changes, showing that the core plasma is not completely unaffected. In the density ramp and power starvation scenarios, undesirable and irregular large-scale events arise clearly in both diagnostic systems as the radiative fraction is increased. Impurity seeding therefore seems to be a promising strategy on W7-X to achieve detachment without significantly altering core turbulence, especially when targeting a specific operating point in core density and heating power.

Wendelstein 7-X

Characterization of runaway electron impact on instrumented sacrificial limiters on DIII-D

Instrumented sacrificial limiter heads, both domed (proud) and flat (flush) are used in DIII-D runaway electron (RE) wall strikes to study the wall impact dynamics with high spatial and time resolution. The approximate structure of the RE wetted area and heating depth on the domed limiter heads were predicted qualitatively using orbit-tracking simulations, although a strong left–right asymmetry (about the magnetic field direction) was not captured well by the simulations. It is hypothesized that this difference is perhaps due to the local 3D magnetic field perturbation of the dome limiter head. The average kinetic energy K and pitch angle θ of REs striking the limiter head were estimated from the spatial distribution of local HXR emission and were estimated to be roughly K ≈ 4 MeV and θ ≈ 0.2 rad. These values are roughly consistent with in-plasma values estimated before the loss event, indicating that RE kinetic energy and pitch angle are not drastically altered when transporting to the wall. Large shot–shot variations (1–10 kJ) in energy deposition into the limiter head were observed and were explained by shot–shot variations in locked magneto-hydrodynamics mode toroidal phase. For the largest deposited energies (10 kJ), graphite material failure and explosive dust release was observed, and the depth of material failure at higher energy deposition was successfully reproduced using modelling of volumetric energy deposition and brittle failure. The presence of energetic (keV) level ion impact during the RE wall strike was confirmed by three different surface analysis techniques. The ratio of energetic ion to RE flux appears to be larger on flat surfaces within the RE wetted area, although the energetic ion flux and total energy flux due to energetic ions have not yet been quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS