Search NASA⌕ Search

SEARCH · Search NASA

Results for “ULTRAVIOLET FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

NASA Technologies that Benefit Society

Applications developed on Earth of technology needed for space flight have produced thousands of spinoffs that contribute to improving national security, the economy, productivity and lifestyle. Over the course of it s history, NASA has nurtured partnerships with the private sector to facilitate the transfer of NASA-developed technology. For every dollar spent on research and development in the space program, it receives back $7 back in the form of corporate and personal income taxes from increased jobs and economic growth. A new technology, known as Liquid-metal alloy, is the result of a project funded by NASA s Jet Propulsion Lab. The unique technology is a blend of titanium, zirconium, nickel, copper and beryllium that achieves a strength greater than titanium. NASA plans to use this metal in the construction of a drill that will help for the search of water beneath the surface of Mars. Many other applications include opportunities in aerospace, defense, military, automotive, medical instrumentation and sporting goods.Developed in the 1980 s, the original Sun Tigers Inc sunlight-filtering lens has withstood the test of time. This technology was first reported in 1987 by NASA s JPL. Two scientists from JPL were later tasked with studying the harmful effects of radiation produced during laser and welding work. They came up with a transparent welding curtain that absorbs, filters and scatters light to maximize protection of human eyes. The two scientists then began doing business as Eagle Eye Optics. Each pair of sunglasses comes complete with ultraviolet protection, dual layer scratch resistant coating, polarized filters for maximum protection against glare and high visual clarity. Sufficient evidence shows that damage to the eye, especially to the retina, starts much earlier than most people realize. Sun filtering sunglasses are important. Winglets seen at the tips of airplane wings are among aviations most visible fuel-saving, performance enhancing technology. Aerodynamics centers on two majors forces-lift and drag. Lift enables the plane to fly and drag is the resistance encountered while moving through the air. The air coming off the end of a standard wing, in a vortex, causes significant drag and turbulence, forcing the spacing between takeoffs. A Langley engineer for NASA published finding in 1976 and verified by test in 1977 that winglets produce a 7 percent increase in lift-drag ratio with a 20 percent decrease in drag. This configuration reduces emissions, allows for greater range and carry more payload and the planes fly more quietly. Winglet technology has saved 2 billion gallons of jet fuel worldwide in 2010. Aerogel represents what technology experts believe to be the best insulation material ever invented. It is very light, flexible and can withstand temperatures of minus 3000 deg F. Aerogel products will be found in everything from clothing, to building insulation to space vehicles. Corpo Nove incorporated the Spaceloft version of the NASA-developed aerogel material into this jacket which was test during an Antarctic expedition.

Griffin, Amanda↗

SKIRT Space Shuttle glow experiment

This paper describes a spectrometer/radiometer experiment to obtain infrared, visible, and ultraviolet measurements of Space Shuttle glow. The payload, Spacecraft Kinetic Infrared Test (SKIRT), is a cryogenic circular variable filter infrared spectrometer with a number of infrared, visible, and ultraviolet radiometers covering the spectral range of 0.2-5.4 microns and 9.9-10.3 microns. It will measure Shuttle glow as a function of mission elapsed time, orbiter attitude, temperature, and orbiter events such as thruster firings. The measured data should have sufficient spectral resolution and sensitivity to identify molecular species contributing to Shuttle glow emissions. SKIRT is manifested on STS-39.

Ahmadjian, M.↗

Very wide field camera

The study of galactic and faint extragalactic extended sources and peculiar ultraviolet objects by a very wide field of view camera, operated in the ultraviolet photometric and spectrometric modes is discussed. The photometric mode is direct photography through filters for observation of the following sources: (1) large scale distribution of ultraviolet radiation in the Milky Way; (2) diffusion of the galactic light above the galactic plane and in front of the large absorbing clouds; (3) the optical emission of the interstellar matter; (4) stars, and starlike objects with diameters less than 3 arc minutes. In the spectrometric mode (nebular spectrograph) the light from the center of the photometric field is concentrated on a slit covering 10 degrees by 10 arc minutes on the sky.

Courtes, G.↗

ASTRO-2 Spacelab Instrument Pointing System mission performance

This paper reports the performance of the Instrument Pointing System (IPS) that flew on the National Aeronautics and Space Administration (NASA) ASTRO-2 Spacelab mission aboard the Space Shuttle Endeavour in March 1995. The IPS provides a stabilizing platform for the ASTRO-2 instrument payload complement that consists of three main experiments (telescopes). The telescopes observe stellar targets in the universe within the ultraviolet portion of the electromagnetic spectrum that must be observed from beyond the earth's atmospheric filtering effects. The three main experiments for observation are the Hopkins Ultraviolet Telescope (HUT), the Ultraviolet Imaging Telescope (UIT), and the Wisconsin Ultraviolet Photo-Polarimetry Experiment (WUPPE). The HUT uses spectroscopy to obtain the structure and chemical makeup of ultraviolet targets. UIT is responsible for wide field photographing to capture the hidden view of the ultraviolet universe. The WUPPE gathers data on the polarization of the ultraviolet electromagnetic energy coming from the astronomical targets. The capability of IPS enables the experiments to 'see' faint celestial objects. A brief explanation of the IPS is given followed by a review of engineering efforts to improve IPS performance over the ASTRO-1 mission. The main focus of improvements was on enhancing the star acquisition capability through improved guide star selection, lab simulations, computer upgrades, data display systems improvements, and software modifications. A star simulator was developed in the lab to enable IPS to be simulated on the ground pre-mission with flight hardware and software in the loop. The paper concludes with results from the ASTRO-2 mission. The number of targets acquired and the IPS pointing accuracy/stability is reported along with recommendations for the future use of the Instrument Pointing System.

Wessling, Francis C., III↗

Measuring Spatially Varying Transmittance Of A Filter

Focusing/collimating-and-scanning apparatus adapts spectro-photometer to spectral transmittance of optical filter as function of position on filter. Mounted in sample chamber of spectrophotometer. All-reflective microscope objectives focus quasi-collimated light onto desired spot and recollimate diverging light emerging from filter. Measurements made in infrared, visible, or ultraviolet.

Labaw, Clayton C.↗

Xenon lighting adjusted to plant requirements

Xenon lamps are available as low and high power lamps with relatively high efficiency and a relatively long lifetime up to several thousand hours. Different construction types of short-arc and long-arc lamps permit a good adaptation to various applications in projection and illumination techniques without substantial changes of the spectral quality. Hence, the xenon lamp was the best choice for professional technical purposes where high power at simultaneously good spectral quality of the light was required. However, technical development does not stand still. Between the luminous efficacy of xenon lamps of 25-50 lm/W and the theoretical limit for 'white light' of 250 lm/W is still much room for improvement. The present development mainly favors other lamp types, like metal halide lamps and fluorescent lamps for commercial lighting purposes. The enclosed sections deal with some of the properties of xenon lamps relevant to plant illumination; particularly the spectral aspects, the temporal characteristics of the emission, and finally the economy of xenon lamps will be addressed. Due to radiation exceeding the natural global radiation in both the ultraviolet (UV) and the infrared (IR) regions, filter techniques have to be included into the discussion referring to the requirements of plant illumination. Most of the presented results were obtained by investigations in the GSF phytotron or in the closed Phytocell chambers of the University of Erlangen. As our experiences are restricted to area plant illumination rather than spot lights our discussion will concentrate on low pressure long-arc xenon lamps which are commonly used for such plant illuminations. As the spectral properties of short-arc lamps do not differ much from those of long-arc lamps most of our conclusions will be valid for high pressure xenon lamps too. These lamps often serve as light sources for small sun simulators and for monochromators which are used for action spectroscopy of plant responses.

Koefferlein, M.↗

Compact X-Ray And Extreme-Ultraviolet Monochromator

Monochromator for x-ray and extreme-ultraviolet radiation provides higher spectral resolution than achieved with thin-metal-foil broad-band-pass filters. Uses Bragg reflection to band-pass-filter radiation from high-intensity, broad-spectrum source. Operates over much broader x-ray and extreme-ultraviolet spectrum than devices based upon natural crystals. Intended to filter continuum radiation from sources like synchrotrons, laser plasma sources, free-electron lasers, and wigglers to produce monochromatic beams for testing and analysis of x-ray and extreme-ultraviolet telescopes and microscopes, for calibration of photographic films and detectors, for biological and biomedical research, for x-ray lithography, for processing of materials, and for research in properties of materials.

Hoover, Richard B.↗

Ultraviolet photometry of planetary nebulae

Nine of the planetary nebulae observed by the Wisconsin filter photometers are compared with 15 Monocerotis in the spectral region 1430-4250 A. The data are corrected for the degradation of the filters of stellar photometer number four with time. Comparisons with simple models indicate that most of the observed nebulae are subject to some interstellar extinction in the far ultraviolet. However, NGC 246 and NGC 1360 appear to be nearly unreddened. Thus far no unexpected features have been found in the observations.

Holm, A. V.↗

Documentation for the machine-readable version of OAO 2 filter photometry of 531 stars of diverse types

A magnetic tape version of the ultraviolet photometry of 531 stars observed with the Wisconsin Experiment Package aboard the Orbiting Astronomical Observatory (OAO 2) is described. The data were obtained with medium band interference filters and were reduced to a uniform magnitude system. They represent a subset of partially reduced data currently on file at the National Space Science Data Center. The document is intended to enable users of the tape file to read and process data without problems or guesswork. For technical details concerning the observations, instrumentation limitations, and interpretation of the data the reference publication should be consulted. This document was designed for distribution with any machine-readable version of the OAO 2 photometric data.

Warren, W. H., Jr.↗

Stratospheric instruments and analyses

The Instruments are divided into two groups, ground based instruments and satellite-borne instruments. The ground based instruments include a Dobson ozone spectrophotometer, a filter ozonometer, and ozonesondes. The satellite-borne instruments include: a backscatter ultraviolet spectrometer, a high resolution infrared radiation sounder, a infrared interferometer spectrometer, a limb radiance inversion radiometer, and multichannel filter radiometer. A list of investigations using stratospheric satellite data is presented.

Source record↗

Filter Enhances Fluorescent-Penetrant-Inspecting Borescope

Slip-on eyepiece for commercial ultraviolet-light borescope reduces both amount of short-wave ultraviolet light that reaches viewer's eye and apparent intensity of unwanted reflections of white light from surfaces undergoing inspection. Fits on stock eyepiece of borescope, which illuminates surface inspected with intense ultraviolet light. Surface, which is treated with fluorescent dye, emits bright-green visible light wherever dye penetrates - in cracks and voids. Eyepiece contains deep-yellow Wratten 15 (G) filter, which attenuates unwanted light strongly but passes yellow-green fluorescence so defects seen clearly.

Molina, Orlando G.↗

GaAsP Photodiodes As X-Ray Detectors

Tests show commercial G1126-02 GaAsP photodiodes designed as ultraviolet detectors modified easily for use as x-ray detectors. Have quartz windows. When used to measure ultraviolet fluxes, windows or other apertures in optical paths covered with optical filters. To modify one of these photodiodes for x-ray application, one removes quartz window and replaces with aluminum foil, which blocks ultraviolet and visible radiation. GaAsP cells cost less than Si cells do and less damaged by radiation.

Laue, Eric G.↗

Characterization of lateral amorphous selenium photodetectors for low-photon and VUV detection at cryogenic temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies ≥80% and area under the curve (AUC) ≥ 0.85 using as few as ∼ 6800 incident 401 nm photons, corresponding to ∼ 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

Amorphous selenium↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

FOS: Physical sciences↗

Simultaneous measurement of three atmospheric pollutants

Method enables simultaneous concentration monitoring of atmospheric SO2, NO, and NO2. Fluorescing pollutant gases in sample are excited by visible output of dye laser and its second-harmonic ultraviolet frequencies. Three photomultipliers, each with suitable optical filters, view fluorescence. Method tests ambient air, stack emissions, and highway automotive exhausts.

Sinha, M. P.↗

The Large Area Pulsed Solar Simulator (LAPSS)

A Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, California, occupies an area measuring about 3 meters wide by 12 meters long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than +/- 2 percent uniformity of irradiance at the test plane and better than +/- 0.3 percent measurement repeatability after warm-up. Glass absorption filters are used to reduce the level of ultraviolet light emitted from the xenon flash lamps. This provides a close match to standard airmass zero and airmass 1.5 spectral irradiance distributions. The 2 millisecond light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices.

Mueller, R. L.↗

A Treatment of Measurements of Heptane Droplet Combustion Aboard MSL-1

Results of measurements on the burning of free n-heptane droplets (that is, droplets without fiber supports) performed in Spacelab during the flights of the first Microgravity Science Laboratory (MSL-1) are presented. The droplet combustion occurred in oxidizing atmospheres which were at an ambient temperature within a few degrees of 300 K. A total of 34 droplets were burned in helium-oxygen atmospheres having oxygen mole fractions ranging from 20 to 50 percent, at pressures from 0.25 to 1.00 bar. In addition, four droplets were burned in air at 1.00 bar, bringing the total number of droplets for which combustion data were secured to 38; two of these four air tests were fiber-supported to facilitate comparisons with other fiber-support experiments, results of which also are given here. Initial diameters of free droplets ranged from about 1 to 4 mm. The primary data obtained were histories of droplet diameters, recorded in backlight on 35 mm film at 80 frames per second, and histories of flame diameters, inferred from emissions through a narrow-band interference filter centered at the 310 micron OH chemiluminescent ultraviolet band, recorded at 30 frames per second by a intensified-array camera. These data are reported here both in raw form and in a smoothed form with estimated error bars. In addition, summaries are presented of measured burning-rate constants, final droplet diameters, and final flame diameters. Both diffusive and radiative extinctions were exhibited under different conditions. Although some interpretations are reported and conclusions drawn concerning the combustion mechanisms, the principal intent of this report is to provide a complete, documented data set for future analysis.

Ackerman, M. D.↗

Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and dark-field mi-croscope designed to meet key objectives defined in the NASA Europa Lander Study Report, includ-ing the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In-situ Research (FLAIR) im-ager, designed and built at NASA Ames Research Center, for the autonomous study of microbial bi-ology in low Earth orbit. For the ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line filter sets to capture successively smaller particles on 10, 1.0, and 0.1 µm pore-size filters for imaging. For darkfield imaging, ELM uses ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect structural and chemical biosignatures as small as 0.2 µm in size is achieved by imaging native fluorescence and us-ing fluorescence microscopy stains to identify key molecular and structural indicators of microbial life (proteins, lipids, nucleic acids). To excite fluorescence, ELM uses LEDs with wavelengths centered near 265, 370, 470, and 530 nm and five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging not only enables the detection of different molecular species, but also their rough classification. Excitation at 265 nm allows for the detection of smaller polyaromatic hydrocarbons (PAHs; 1-5 rings), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures (e.g., coronene) and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and sep-arated from organic fluorescence, allowing the recognition and in some cases classification, of miner-als and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Microscope↗