Search NASASearch

SEARCH · Search NASA

Results for “anion-exchanged membranes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

125 records · Page 7

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Hybrid biophysical systems for atmospheric CO 2 capture

Negative emissions technologies will be essential for limiting anthropogenic global temperature increases to 2 °C in the later years of the 21st century. Carbonic anhydrase (CA) metalloenzymes catalyze the otherwise slow conversion of CO 2 into carbonic acid (H 2 CO 3 ), suggesting their utility in the rapid hydration and downstream capture of dissolved CO 2 in aqueous media for a variety of CO 2 capture methods, such as thermal and pH swings and mineralization. The possibility of driving the rapid capture of CO 2 by catalyzing the CO 2 hydration bottleneck carries real potential for realizing efficient direct air capture (DAC) and direct ocean capture (DOC) systems. However, scaled application of CAs will be dependent on some way of economically sourcing the enzymes at volumes relevant to scaled DAC/DOC operations. In this perspective, we consider the prospect of catalyzing CO 2 hydration using a CA that is bound to the outer membrane of a cyanobacterial host, engineered constructs we call CyCAMs. Coupling extracellular CA expression to a marine, photosynthetic cyanobacterial host results in a CO 2 hydration catalyst that is continuously refreshed during the bacterial growth cycle, without the need for enzyme purification or harvesting steps. In the case of marine cyanobacteria, sunlight and the solutes native to seawater provide the respective energy, nutrients and sources of inorganic carbon essential to maintaining the bacterial population. We consider the potential impact of CA-mediated CO 2 hydration on a variety of DAC processes, with CO 2 mineralization explored as a primary use case.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

A physically interpretable precursor framework for sub-seasonal prediction of Northern Hemisphere flash flourishing

Flash flourishing describes rapid vegetation increases that can quickly reshape land–atmosphere exchanges and impacts on ecosystem, yet its large-scale precursors, circulation context, and sub-seasonal predictability remain poorly understood. Here, we identified onset-stage circulation regimes across northern extratropical latitudes (NEL; >30°N) using 200 and 1000 hPa geopotential height, and examined their regional expressions over eastern Asia, western North America, and Europe. Flash flourishing onset in East Asian was associated with a baroclinic circulation regime and was preceded by a North Atlantic sea surface temperature (SST) precursor at a four-pentad lead. In contrast, onset in western North American and European preferentially occurred under barotropic regimes, preconditioned by Great Plains soil moisture at three-pentad lead and North Atlantic SST at a four-pentad lead, respectively. Ridge regression forecasts revealed regime-dependent sub-seasonal predictability, with mean out-of-sample R 2 exceeding 0.3 up to lead times of two pentads in East Asia, three pentads in western North America, and four pentads in Europe. Together, these findings established a mechanistic and regionally specific framework for anticipating rapid vegetation greening at sub-seasonal timescales.

Kong, Xiangxu [Nanjing Univ. of Information Scienc

Trust-Based Detection and Mitigation of Cyber Attacks in Distributed Cooperative Control of Islanded AC Microgrids

In this study, we address the challenge of detecting and mitigating cyber attacks in the distributed cooperative control of islanded AC microgrids, with a particular focus on detecting False Data Injection Attacks (FDIAs), a significant threat to the Smart Grid (SG). The SG integrates traditional power systems with communication networks, creating a complex system with numerous vulnerable links, making it a prime target for cyber attacks. These attacks can lead to the disclosure of private data, control network failures, and even blackouts. Unlike machine learning-based approaches that require extensive datasets and mathematical models dependent on accurate system modeling, our method is free from such dependencies. To enhance the microgrid’s resilience against these threats, we propose a resilient control algorithm by introducing a novel trustworthiness parameter into the traditional cooperative control algorithm. Our method evaluates the trustworthiness of distributed energy resources (DERs) based on their voltage measurements and exchanged information, using Kullback-Leibler (KL) divergence to dynamically adjust control actions. We validated our approach through simulations on both the IEEE-34 bus feeder system with eight DERs and a larger microgrid with twenty-two DERs. The results demonstrated a detection accuracy of around 100%, with millisecond range mitigation time, ensuring rapid system recovery. Additionally, our method improved system stability by up to almost 100% under attack scenarios, showcasing its effectiveness in promptly detecting attacks and maintaining system resilience. These findings highlight the potential of our approach to enhance the security and stability of microgrid systems in the face of cyber threats.

Computer Science

Monitoring Depolymerization in Mesopores Using Dynamic Properties of Polymeric Melt Accessed via Dielectric Spectroscopy

Traditional design principles for heterogeneous catalysis guide the use of catalytic particles with mesosized (∼2–50 nm) pores to increase the number of surface-active sites by way of an increased surface area. However, the entry of long-chain polymers into such pores may be significantly limited by the size and entanglement of polymers in the melt state, thereby decreasing the number of accessible sites. Assessment of catalyst performance from traditional reactor-based studies averages over intrapore reaction events as well as reactions on the surface of a particle, resulting in an inability to distinguish between differences in site accessibility and activity. Techniques that assess the intrapore performance can inform the design of future heterogeneous catalysts for polymer upcycling. In this work, we demonstrate the use of broadband dielectric spectroscopy to monitor depolymerization of a polymer melt within mesopores via changes in the segmental relaxation time scale of amorphous polymer chains. In particular, we highlight the use of an anodic aluminum oxide (AAO) membrane as a readily available model for catalyst pores with a well-characterized pore morphology. The decrease in the segmental relaxation (α-relaxation) time of the melt with increasing chain scission emerges as a measure of the extent of polymer deconstruction inside mesopores. To demonstrate the utility of this technique, we demonstrate the decomposition of two commercial poly(propylene carbonate) polymers with different decomposition rates within mesopores. As the polymers depolymerize, their segmental relaxation time decreases as the molecular weight decreases (as predicted by the Fox–Flory equation). The BDS-measured change in segmental relaxation time mirrors the expected trend based on change in molecular weight measured by size exclusion chromatography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Chromium versus Aluminum: Impact of Nickel Alloy Composition and Interfacial Kinetics on High-Temperature Passivating Oxide Formation

High-temperature corrosion resistance depends critically on the formation of a passivating surface oxide, which is highly sensitive to alloy composition and structure. Such details often elude experimental investigation, and simplified analytical models fail to provide a truly chemical view of passivating oxide evolution. Here, we explicitly compare the fundamental chemistry of Cr and Al as prototypical passivating elements in Ni alloys by directly simulating competing reaction and diffusion processes within the oxide film using kinetic Monte Carlo and density functional theory. We find that the origin and expression of passivating behavior during early-stage thermal oxidation are qualitatively different between the two alloy systems. Ni–Cr alloys feature a sudden onset of passivation associated with a sharp phase transition upon Cr enrichment that directly couples oxidation kinetics to phase transformation behavior. In contrast, Ni–Al alloys display more continuous oxide phase variation with Al enrichment, ultimately resulting in a lower composition threshold for passivation and a thinner passivating layer. In addition, we elucidate the nonobvious role of metal exchange within the alloy near the oxide boundary, which fundamentally alters film composition and passivating behavior. Furthermore, our results have key implications for engineering improved corrosion-resistant alloys, both in terms of compositional variation and processing.

Alloys

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped

Derivation of low-energy Hamiltonians for heavy-fermion materials

Here, by utilizing a multiorbital periodic Anderson model with parameters obtained from ab initio band structure calculations, combined with degenerate perturbation theory, we derive effective Kondo-Heisenberg and spin Hamiltonians that capture the interaction among the effective magnetic moments. This derivation encompasses fluctuations via both nonmagnetic 4⁢𝑓 0 and magnetic 4⁢𝑓 2 virtual states, and its accuracy is confirmed through comparison with experimental data obtained from CeIn 3 . The significant agreement observed between experimental results and theoretical predictions underscores the potential of deriving minimal models from first-principles calculations for achieving a quantitative description of 4⁢𝑓 materials. Moreover, our microscopic derivation unveils the underlying origin of anisotropy in the exchange interaction between Kramers doublets, shedding light on the conditions under which this anisotropy may be weak compared to the isotropic contribution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Nuclear Safety [Vol. 37, No. 2, April-June 1996]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 97 The Nuclear Community and the Public: Cognitive and Cultural Influences on Thinking About Nuclear Risk, M. A. Meyer; 109 Twenty-Third Water Reactor Safety Information Meeting, D. A. Copinger; ACCIDENT ANALYSIS: 126 Analysis of a PWR LBLOCA Without SCRAM, Trevor N. Tyler, Rafael Macian-Juan and John H. Mahaffy; DESIGN FEATURES: 139 Vulnerability of Multiple-Barrier Systems, N. C. Lind; ENVIRONMENTAL EFFECTS: 149 A Study of Wet Catalytic Oxidation of Radioactive Spent Ion Exchange Resin by Hydrogen Peroxide, Xingchao Jian, Tianbao Wu, and Guichun Yun; 157 A Comparison Study and Resolution of Differences Between Emergency Response and Safety Analysis Codes Used at the Savannah River Site, A. A. Simpkins; OPERATING EXPERIENCES: 164 Reactor Shutdown Experience, Compiled by J. W. Cletcher; RECENT DEVELOPMENTS: 167 Reports, Standards, and Safety Guides, D. S. Queener; 172 Proposed Rule Changes as of Dec. 31,1995; ANNOUNCEMENTS: 178 American Nuclear Society 1997 Annual Meeting; 178 American Nuclear Society Nuclear Criticality and Safety Division Topical Meeting; 176 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Compatibility of Type 304H Stainless Steel in Static Molten FLiBe for Inertial Confinement Fusion Reactors: Role of Impurities and Redox Control

Molten fluoride salts, such as FLiBe (LiF-BeF2), are promising candidates for tritium breeding and heat transfer in fusion reactors, but corrosion of structural materials remains a major challenge. This study investigates the corrosion behavior of austenitic stainless steel 304H in purified and NiF2-containing FLiBe at 500°C and 600°C, focusing on the effects of impurities and redox control. Exposure to purified FLiBe resulted in the concurrent depletion of Cr, Mn, and Fe, with corrosion at 500 °C dominated by the combined oxide formation and elemental dissolution, while at 600°C elemental depletion was predominant. The addition of a controlled NiF2 impurity significantly accelerated corrosion at both temperatures, demonstrating the sensitivity of 304H to the salt redox state. Beryllium additions were effective in mitigating corrosion for both baseline and NiF2-containing FLiBe; minimal depletion of Cr, Mn, and Fe occurred with Be additions as low as 2.5 mg (147 wppm), and no NiBe intermetallics formed at 5 mg (294 wppm), indicating that small Be inventories can provide substantial protection without deleterious phase formation. Thermodynamic equilibrium and coupled thermodynamic-kinetic analyses at the salt-alloy interface suggested low corrosion rates in systems with limited hydrogen fluoride (HF) generation, highlighting the importance of salt redox control. Estimates for a Be addition rate were calculated for the HYLIFE-II fusion reactor that can mitigate corrosion-induced degradation, assuming complete conversion of tritium to tritium fluoride (TF). Overall, 304H shows reasonable compatibility with FLiBe under optimized redox conditions. These results provide quantitative guidance for material selection and salt management in fusion blanket and heat exchanger systems and motivate validation under flowing, nonisothermal, and irradiated conditions.

Pillai, Rishi [ORNL] (ORCID:0000000243688197)

Statistical Study of Energy Dissipation in Magnetic Structures During Turbulent Reconnection in the Earth's Magnetotail

Magnetic reconnection is a ubiquitous plasma phenomenon that plays a critical role in particle heating and energization. During reconnection, the topology of magnetic field rearranges, depositing energy into the surrounding plasma through bulk flow, thermal heating, or non-thermal particle acceleration. While the pathways of this transformation from magnetic energy into kinetic have been studied extensively in recent years through theoretical or case-by-case observations, comprehensive statistical studies remain limited. In this paper, we present a statistical investigation using data from the Magnetospheric Multiscale (MMS) mission, and detail the particle energization mechanisms in magnetic structures found near reconnecting regions in turbulent Earth's magnetotail. We find that electrons with motion perpendicular to the magnetic field dominate $\vec{j}$ ⋅ $\vec{E}$ dissipation. In contrast to the conventional picture of unidirectional energy transfer to particles by laminar two-dimensional (2D) reconnection, we find that energy exchange within magnetic structures during turbulent reconnection tends to be bidirectional with only a small positive bias from electromagnetic fields to particles. Specific electron energization mechanisms are quantified, including those due to parallel electric field, Fermi energization from curvature drift, betatron heating from magnetic field inhomogeneity, and polarization drift.

Wang, Rachel [Princeton University, NJ (United Sta

Nuclear Safety [Vol. 37, No. 2, April-June 1996]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 97 The Nuclear Community and the Public: Cognitive and Cultural Influences on Thinking About Nuclear Risk, M. A. Meyer; 109 Twenty-Third Water Reactor Safety Information Meeting, D. A. Copinger; ACCIDENT ANALYSIS: 126 Analysis of a PWR LBLOCA Without SCRAM, Trevor N. Tyler, Rafael Macian-Juan and John H. Mahaffy; DESIGN FEATURES: 139 Vulnerability of Multiple-Barrier Systems, N. C. Lind; ENVIRONMENTAL EFFECTS: 149 A Study of Wet Catalytic Oxidation of Radioactive Spent Ion Exchange Resin by Hydrogen Peroxide, Xingchao Jian, Tianbao Wu, and Guichun Yun; 157 A Comparison Study and Resolution of Differences Between Emergency Response and Safety Analysis Codes Used at the Savannah River Site, A. A. Simpkins; OPERATING EXPERIENCES: 164 Reactor Shutdown Experience, Compiled by J. W. Cletcher; RECENT DEVELOPMENTS: 167 Reports, Standards, and Safety Guides, D. S. Queener; 172 Proposed Rule Changes as of Dec. 31,1995; ANNOUNCEMENTS: 178 American Nuclear Society 1997 Annual Meeting; 178 American Nuclear Society Nuclear Criticality and Safety Division Topical Meeting; 176 The Authors.

05 NUCLEAR FUELS

Hybrid Bio-Based Composites: Enabling Cellulose Nanofiber (CNF) Incorporation into Composites via Macroscale Natural Fiber Carriers

Cellulose nanofibers (CNFs) have significant potential in composites as additives to improve mechanical properties, melt rheology, and more. However, agglomeration of CNFs is a key challenge in composite melt processing as obtaining nano-level dispersion of CNFs often requires cost- and energy-intensive processes (e.g., solvent exchange or freeze drying) due to the strong hornification tendencies of CNF. Herein, we avoid these challenges by using a natural fiber carrier method to integrate CNF into thermoplastic composites. Fibers are co-dried to create a hybrid fiber feedstock for compounding in which natural fibers are decorated with dispersed nanofibers. The hybridized fibers result in up to a 24% increase in tensile strength and up to a 35% increase in Young’s modulus compared to composites only containing natural fibers. The lignocellulosic nanofibers are found to outperform their purely cellulosic counterpart, which is theorized to be due to either an increased propensity for fibrillation of the lignocellulosic fibers or the increased hydrophobicity of the fibers due to the presence of lignin. Surface analysis of fiber feedstocks, via streaming potential measurements and dynamic light scattering (DLS), confirmed a significant change in the feedstock hydrophobicity before and after hybridization. While mild additions of CNF (1 wt.% on the macroscale fiber) do not impact the composite melt viscosity, the viscosity is found to increase at higher CNF loadings (5 wt.% on the macroscale fiber), indicating its utility as a rheology modifier. Lastly, use of these materials as novel feedstocks for medium-scale additive manufacturing in high-fidelity part production was demonstrated.

bio-based

Noncollinear spin order, field-induced transitions, and short-range correlations in Cu 4 ⁢SO 4 ⁢(OH) 6

We report a comprehensive study of spin-$\frac{1}{2}$ quantum magnet brochantite, Cu 4 ⁢SO 4 ⁢(OH) 6 , combining high-field thermodynamic measurements, polarized neutron diffraction, inelastic neutron scattering, and nuclear magnetic resonance spectroscopy. Using bulk magnetization and specific heat measurements we construct the magnetic 𝐻−𝑇 phase diagram for magnetic fields applied along main crystallographic directions up to 24.1 T. Polarized neutron diffraction reveals a noncollinear magnetic ground state confined to the 𝑎⁢𝑏 plane. A field-induced transition is observed for magnetic fields in the 𝑎⁢𝑏 plane whose critical field and character evolve continuously with field direction in the 𝑎⁢𝑏 plane. While the transition for 𝐻 ∥ 𝑏 might be a spin-flop-like transition, the one for 𝐻 ∥ 𝑎 resembles the short-range correlated state above 𝑇 N , suggesting a magnetic configuration related to the quasi-two-dimensional correlations in the 𝑏⁢𝑐 planes. The experimental results demonstrate that the ground-state and field-induced phases cannot be explained by a simple XXZ model with a single dominant exchange interaction and that weaker interchain and anisotropic interactions have to be taken into account. Our work establishes brochantite as a low-symmetry Cu-based quantum magnet with noncollinear order and complex field-induced behavior.

Prokhnenko, Oleksandr [Helmholtz-Zentrum Berlin (H

Evaluating Polymer Properties with Different Additives for Carbon Capture and Other Applications

Anthropogenic climate change is one of this generation’s most pressing concerns, with the potential to completely alter the delicate balance we’ve struck with nature. Already, global temperatures have risen 1.29°C, leading to disrupted weather systems, extinctions, increased risks of wildfires, and sea level rise, to name a few effects. Carbon dioxide emission from the combustion of fossil fuels and other industrial activity is a large driver of this phenomenon, as it absorbs heat before it can be radiated away from Earth, trapping it. Carbon dioxide has reached unprecedented levels in our atmosphere, showing a 50% increase from preindustrial averages to a whopping 430 ppm. Thus, reducing the amount of carbon dioxide via carbon capture technology is an important endeavor that serves to benefit everyone. The Microencapsulated CO 2 Sorbent (MECS) team at Lawrence Livermore National Laboratory (LLNL) has turned to microencapsulation to approach this endeavor. Microcapsules provide an attractive approach to carbon capture, combining large surface areas for more efficient mass transfer, regenerative abilities, reduced solvent loss, and improved handling. Additionally, while existing carbon capture technology relies on industrial plants, capsules could present a modular approach to carbon capture, reducing the need for extensive physical infrastructure. The MECS team’s design consists of a polymer membrane that contains a liquid carbon sequestering sorbent, aqueous sodium carbonate. The carbon capturing reaction occurs in three distinct steps, the first of which is the dissolution of carbon dioxide into the sorbent solution and its conversion into carbonic acid (H 2 CO 3 ), shown in equations 1 and 2 respectively. Because this step hinges upon the ability of carbon dioxide to reach the solution inside the capsule, it is necessary that the microcapsule shell is permeable to carbon dioxide gas. The MECS team produces these microcapsules using the in-air droplet encapsulation apparatus (IDEA) shown in figure 1, which can produce uniform micron-scale droplets at speeds much faster than traditional single-dispersal microfluidic-based techniques. The IDEA Is 100 times faster than these current techniques and can reach up to 1000 times their speed when incorporating a multi-nozzle design. Additionally, because droplets are produced in-air via vibration, IDEA can decrease post-processing times and material waste by 99% and can fabricate microgels that are 10 to 100 times more viscous than can be produced via traditional microfluidics. While this design represents a breakthrough in the throughput, efficiency, and tunability of microcapsule production, it imposes a major constraint on the microcapsule curing process. Because microcapsule shells are crosslinked with UV light while falling 30 cm through the air, this gives them a reaction window of approximately 0.2 seconds. Thus, the system and shell formulations must be optimized such that the shells can be fully crosslinked within this very narrow window, prompting investigations into curing behavior.

36 MATERIALS SCIENCE

Magnet-superconductor hybrid quantum systems: a materials platform for topological superconductivity

Magnet–superconductor hybrid (MSH) systems have recently emerged as one of the most significant developments in condensed matter physics. This has generated, in the last decade, a steadily rising interest in the understanding of their unique properties. They have been proposed as one of the most promising platforms for the establishment of topological superconductivity, which holds high potential for application in future quantum information technologies. Their emergent electronic properties stem from the exchange interaction between the magnetic moments and the superconducting condensate. Given the atomic-level origin of such interaction, it is of paramount importance to investigate new magnet–superconductor hybrids at the atomic scale. In this regard, scanning tunneling microscopy (STM) and spectroscopy are playing a crucial role in the race to unveil the fundamental origin of the unique properties of MSH systems, with the aim to discover new hybrid quantum materials capable of hosting topologically non-trivial unconventional superconducting phases. In particular, the combination of STM studies with tight-binding model calculations have represented, so far, the most successful approach to unveil and explain the emergent electronic properties of MSHs. The scope of this review is to offer a broad perspective on the field of MSHs from an atomic-level investigation point-of-view. The focus is on discussing the link between the magnetic ground state hosted by the hybrid system and the corresponding emergent superconducting phase. This is done for MSHs with both one-dimensional (atomic chains) and two-dimensional (atomic lattices and thin films) magnetic systems proximitized to conventional s-wave superconductors. We present a systematic categorization of the experimentally investigated systems with respect to defined experimentally accessible criteria to verify or falsify the presence of topological superconductivity and Majorana edge modes. The discussion will start with an introduction to the physics of Yu–Shiba–Rusinov bound states at magnetic impurities on superconducting surfaces. This will be used as a base for the discussion of magnetic atomic chains on superconductors, distinguishing between ferromagnetic, antiferromagnetic and non-collinear magnetic ground states. A similar approach will be used for the discussion of magnetic thin film islands on superconductors. Given the vast number of publications on the topic, we limit ourselves to discuss works which are most relevant to the search for topological superconductivity.

Majorana states

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI