Search NASA⌕ Search

SEARCH · Search NASA

Results for “bench tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Investigation of a Multi-Rotor Triboelectric Nanogenerator Using a Modular Flexible Circuit Board Stack

Triboelectric nanogenerators (TENGs) are a nascent class of energy harvester that are being explored for scavenging energy from small ocean waves. To date, they have been integrated in wave energy converters (WECs) designed to capture random motion caused by the perturbations of the ocean surface. Blue economy applications such as ocean observation can benefit greatly from more substantial wave-derived power, as such, the power output of existing TENG WECs must be increased several-fold to become viable. This study describes the conceptualization of a rotary TENG, and the subsequent efforts to increase its power output by stacking multiple stator and rotor pairs. In the latter part of this study, we introduce a novel means of incorporating a friction element into the design of the TENG by employing flexible printed circuit board (PCB) rotors. At rest, these flexible rotors will contact the stator, building static charges due to friction, at speed, these flexible rotors will be decoupled from the stator, reducing friction and allowing faster rotation. Initial results indicate that the power output of the flexible PCB rotor does not produce more power than a rigid, acrylic disk rotor, however the current output of the prototype is boosted, and the prototype is far more compact, allowing for a higher energy density than the rigid rotor prototype.

bench testing↗

Non-Fouling, Low Cost Electrolytic Coagulation & Disinfection for Treating Flowback and Produced Water for Reuse

Executive Summary This Final Report is composed of two major sections. The first section presents experimental results obtained in the laboratory during Budget Period 1. The second section presents results from the field test conducted during Budget Period 2. Laboratory Results This research investigated a novel electrochemical process for producing a ferric iron coagulant for use in treating flowback and produced water from hydraulic fracturing and oil production operations. The treatment system improves the effectiveness and lowers the cost of coagulation processes using Fe3+ as the coagulant. The electrolytic coagulant generation (ECG) system uses an electrochemical cell to produce acid and base from oilfield brine solutions. The acid is used to dissolve scrap iron to provide a Fe3+ coagulating agent. The base is used to neutralize the treated water. Compared to conventional electrocoagulation (EC), the main advantage of the ECG system is an order of magnitude lower cost for the source of iron. The second advantage over conventional EC is that it can deliver Fe3+ doses greater than 1 mM, since it is not limited by the amount of dissolved oxygen in the water required to oxidize ferrous to ferric iron. The capital costs for conventional EC and the ECG system are similar, but the operational costs for the ECG system are an order of magnitude lower than conventional EC. The combined costs for iron and electrical energy for treating 1 m3 of FPW with 1 mM Fe3+ is estimated to be $0.87 for conventional EC, and $0.087 for the ECG system. The estimated all-in cost for treating FPW with a 2 mM Fe3+ dose is $0.73/m3 ($0.12/bbl). Field Test Results The field test was conducted at the Paul Foster Central Tank Battery (CTB) in Lea County, New Mexico from November 10, 2022 through December 15, 2022. The feed water to the system was produced water from the Tatanka 1H formation. After approximately two weeks of testing, the initial batch of produced water had been treated and no untreated produced water was available. Thus, after this time, the feed water to the system consisted of previously treated water (i.e., recycled water). The recycled water had nearly all colloidal particles removed, and had a much lower alkalinity due to precipitation of carbonate minerals during the first pass through the system. Although the recycled water was not an ideal test solution due to its low particulate concentrations, its lower alkalinity did allow us to identify the main problem with the treatment system. The main problem with the treatment system was caused by the high alkalinity of the initial feed water (5.4 meq/L) that consumed a significant fraction of the electrochemically generated acid. This resulted in pH values exiting the iron contact tank that were too high to dissolve enough iron to effectively treat the produced water. Tests performed with recycled water with lower alkalinity did not have this issue, and dissolved iron concentrations greater than 20 mM could be achieved. One consistent observation was that effluent water from the iron contact tank was always free of particulates, even when fed with circumneutral solutions. This suggests that there is no need to dissolve high concentrations of iron if all the water to be treated is passed through the scrap iron canister. In this case, dissolved O2 and hypochlorous acid can promote sufficient iron corrosion to provide an effective coagulating agent – even in neutral pH water. This solves the problem resulting from highly alkaline produced water. Modifications to the design of the treatment system were made based on the field test results. These modifications will add minimal additional cost, and were tested in bench-scale laboratory experiments. In short-term testing, the modified treatment process was able to remove colloidal FeS particulates to levels below detection. Long-term, steady state testing will be required to determine whether the modified process is suitable for commercial treatment systems.

54 ENVIRONMENTAL SCIENCES↗

Outcomes and Conclusions from the 2022 AM Bench Measurements, Challenge Problems, Modeling Submissions, and Conference

The Additive Manufacturing Benchmark Test Series (AM Bench) provides rigorous measurement data for validating additive manufacturing (AM) simulations for a broad range of AM technologies and material systems. AM Bench includes extensive in situ and ex situ measurements, simulation challenges for the AM modeling community, and a corresponding conference series. In 2022, the second round of AM Bench measurements, challenge problems, and conference were completed, focusing primarily upon laser powder bed fusion (LPBF) processing of metals, and both material extrusion processing and vat photopolymerization of polymers. In all, more than 100 people from 10 National Institute of Standards and Technology (NIST) divisions and 21 additional organizations were directly involved in the AM Bench 2022 measurements, data management, and conference organization. The international AM community submitted 138 sets of blind modeling simulations for comparison with the in situ and ex situ measurements, up from 46 submissions for the first round of AM Bench in 2018. Analysis of these submissions provides valuable insight into current AM modeling capabilities. The AM Bench data are permanently archived and freely accessible online. The AM Bench conference also hosted an embedded workshop on qualification and certification of AM materials and components.

36 MATERIALS SCIENCE↗

In situ multimodal imaging for nanoscale visualization of tribofilm formation

A third of the energy from fuel combustion in passenger car gasoline engines is lost due to friction. Carefully designed engine lubricants can recover some of these losses by reducing friction and wear by forming a nanometer-scale chemico-physico tribofilm between surfaces. Accordingly, attention has focused on developing oil formulations that form low-friction tribofilms. However, analyses of resultant tribofilms are typically conducted after tribo-tests with conventional characterization tools and do not offer insights into tribofilm formation and evolution, precluding information critical to tuning tribofilm properties. In this work, we developed a unique multimodal methodology based on Atomic Force Microscopy (AFM) with local probe heating for in situ tribological studies that activates friction modifiers and simultaneously captures the evolution of friction and surface roughness, with nanometer resolution. As a platform to demonstrate the ability of this methodology to visualize dynamics of tribofilm formation in situ, we apply it to molybdenum-based friction modifiers to distinguish key factors in their functionality and correlate nanoscale AFM and Friction Force Microscopy data to bench tribo-tests used in the industry. To decode the formation mechanisms observed in situ and underlying chemistry of tribofilms, we performed ab initio Molecular Dynamics (AIMD) simulations at comparable conditions. AIMD simulations confirmed both nanoscale and bench tribo-test results and showed deviations in molecular organization in tribofilms that are formed from different molybdenum-based friction modifiers that corroborates with surface functionality. With this innovative methodology, we demonstrate proof-of-principle in situ formation of molybdenum-based tribofilms directly on steel surfaces that could be applied generally to studying tribofilm formation.

36 MATERIALS SCIENCE↗

Development of a Flotation Simulator That Can Predict Grade vs. Recovery Curves from Mineral Liberation Data

Flotation is a kinetic process designed to separate mineral fines by control of hydrophobicity. In general, both the recovery and selectivity of a flotation process increase with contact angle. It is difficult, however, to model flotation kinetics using the thermodynamic parameter. In the present work, we consider flotation as heterocoagulation so that the bubble-particle interactions occurring in the pulp phase of a flotation cell can be modeled using the hydrophobic force as a kinetic parameter that can represent the role of contact angles in flotation. Here, the pulp-phase model developed in this manner has been combined with a froth-phase model developed earlier by considering the effect of particles in film thinning kinetics and bubble coarsening (Park et al, 2018). The combined model has been used to develop a flotation simulator that can be used to construct grade vs. recovery curves from feed characteristics (e.g., mineral liberation and particle size) and various operating parameters. The simulator has been tested successfully against a set of bench-scale continuous flotation test results reported in the literature (dos Santos and Galery, 2018).

58 GEOSCIENCES↗

Mitigation Methods for Piperazine Oxidation in Post-Combustion Carbon Capture

Piperazine is a promising second-generation solvent for amine scrubbing in post-combustion CO2 capture. However, the oxidative degradation of PZ can cause environmental problems and economic loss. This work presents the effects of two mitigation methods: carbon treating and N2 sparging, on the PZ oxidation in long-term operations. The species and their respective quantities adsorbed by the activated carbon were tested in a bench-scale device. The carbon was then tested in the High Temperature Oxidation Reactor (HTOR), where the solvent oxidizes at a reasonably fast rate. Pilot plant campaigns were also performed at the UT Austin SRP and the National Carbon Capture Center (NCCC) and the effects were verified. When dissolved Fe is removed by carbon treating or other methods, available soluble Fe in the system dissolves and replaces the dissolved Fe. Therefore, all available Fe and ligands need to be removed for the mitigation to be effective. The sources of soluble Fe include fly ash and the corrosion of stainless steel, and the ligands are degradation products. 8 All PZ degraded solvents have two absorbance peaks at 320 nm and 538 nm. The 320 nm peak is caused by dissolved metals, especially Fe, complexed by degradation products. The 320 nm peak is related to the amine degradation level and can be used as a simple and efficient method to estimate the amine degradation rate. The pilot plant data suggest that NO2 can oxidize PZ significantly, possibly through radical reactions. 0.01 mmol/kg-hr absorption of NO2 increased the PZ oxidation rate from 1.2 mmol/kg-hr to 2.5 mmol/kg-hr.

Yuying, Wu↗

NETL Direct Air Capture Center

In 2022 Congress authorized the $25M National Energy Technology Laboratory Direct Air Capture Center. The facility will be specifically targeted at accelerating the commercialization of technologies beyond the conceptual stage which have not yet reached full pilot-scale (TRL 3 to 6). The ability to operate over a wide range of conditions will help the developers to understand how their technologies respond in different climates, from summer to winter and arid to tropical. NETL recognizes that DAC technology is still early in its evolution, and a wide variety of highly varied technologies are being explored. The Center will be designed with substantial flexibility to accommodate the rapidly evolving technological landscape. Testing systems at three scales will be included: lab-scale systems designed to examine the long-term stability of DAC materials, bench-scale module testing systems capable of probing flow dynamics, and small pilot-scale skid rooms able to test prototype DAC units under a wide variety of climate conditions. The NETL DAC Center will feature dedicated engineering, technician, scientific and logistical support for experimental system design, installation, operation of experiments, and interpretation of results for projects including but not limited to kinetics of absorption/desorption, thermal duty, and post-mortem elemental characterization to understand degradation. The NETL DAC Center projects will also have access to dedicated process modeling and analysis to evaluate the technoeconomic aspects of new technologies. NETL’s Systems Engineering and Analysis (SEA) team, the Carbon Capture Simulation Initiative (CCSI), and the Institute for the Design of Advanced Energy Systems (IDAES) are all potential collaborators with NETL’s testing partners from industry, academia, and other research institutions. NETL also has world class capabilities in device scale modeling (i.e., MFIX) that will be available to help design more efficient contactors and optimize unique internal configurations that can be realized by advanced manufacturing. The talk will cover the design and capabilities of the center, the planned availability, and feedback will be solicited from the audience on DAC testing needs.

Luebke, David↗

Accelerating commercialization of direct air capture technology

In 2022 Congress authorized the $25M National Energy Technology Laboratory Direct Air Capture Center. The facility will be specifically targeted at accelerating the commercialization of technologies beyond the conceptual stage which have not yet reached full pilot-scale (TRL 3 to 6). The ability to operate over a wide range of conditions will help the developers to understand how their technologies respond in different climates, from summer to winter and arid to tropical. NETL recognizes that DAC technology is still early in its evolution, and a wide variety of highly varied technologies are being explored. The Center will be designed with substantial flexibility to accommodate the rapidly evolving technological landscape. Testing systems at three scales will be included: lab-scale systems designed to examine the long-term stability of DAC materials, bench-scale module testing systems capable of probing flow dynamics, and small pilot-scale skid rooms able to test prototype DAC units under a wide variety of climate conditions. The NETL DAC Center will feature dedicated engineering, technician, scientific and logistical support for experimental system design, installation, operation of experiments, and interpretation of results for projects including but not limited to kinetics of absorption/desorption, thermal duty, and post-mortem elemental characterization to understand degradation. The NETL DAC Center projects will also have access to dedicated process modeling and analysis to evaluate the technoeconomic aspects of new technologies. NETL’s Systems Engineering and Analysis (SEA) team, the Carbon Capture Simulation Initiative (CCSI), and the Institute for the Design of Advanced Energy Systems (IDAES) are all potential collaborators with NETL’s testing partners from industry, academia, and other research institutions. NETL also has world class capabilities in device scale modeling (i.e., MFIX) that will be available to help design more efficient contactors and optimize unique internal configurations that can be realized by advanced manufacturing. The talk will cover the design and capabilities of the center, the planned availability, and feedback will be solicited from the audience on DAC testing needs.

Luebke, David↗

MODELING, IMPLEMENTATION AND CONTROL OF A CVT BASED PTO FOR A SMALL SCALE MHK-TURBINE IN LOW FLOW SPEED OPERATION

Modeling, implementation, field testing and control of a power takeoff (PTO) device equipped with a ball-type continuously variable transmission (B-CVT) for a small marine hydrokinetic (MHK) turbine deployed from a floating unmanned autonomous mobile catamaran platform is described. The turbine is a partially submerged multi-blade undershot waterwheel (USWW). A validated numerical torque model for the MHK turbine has been derived and a speed controller has been developed, implemented and tested in the field. The dependance of the power generated as a function of number and submergence level of turbine blades has been investigated and the number of blades that maximizes power production is determined. Bench and field testing in support of characterizing the power conversion capabilities of MHK turbine and PTO are described. Detailed results of the final torque and power coefficient models, the controls architecture, and the MHK turbine performance with varying numbers of blades are provided.

Pimentel, Hugo↗

BENCH-SCALE DEVELOPMENT OF A TRANSFORMATIVE MEMBRANE PROCESS FOR PRE-COMBUSTION CO 2 CAPTURE

This final technical report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the Department of Energy, National Energy Technology Laboratory (DOE NETL) on development of the second generation (Gen-2) Proteus™ membrane modules and a pre-combustion membrane process for carbon dioxide (CO 2 ) capture from an Integrated Gasification Combined Cycle (IGCC) plant for power generation (award number DE-FE0031632). The work was conducted from October 1, 2018 through March 30, 2022. The overall goal of this project was to bring a Gen-2 version of the H2-selective Proteus membrane to bench-scale module (component) testing with real syngas. MTR was assisted in this project by Susteon, a technology development company with extensive experience in gasification processes, and the University of North Dakota Energy & Environmental Research Center (EERC), who provided the host site for the slipstream field testing. This report details the work conducted to optimize the Gen-2 Proteus membrane and develop modules capable of operation at 200°C; demonstrate membrane module performance processing coal-derived syngas during a field test at EERC; and optimize integration of a dual-membrane process into an IGCC with carbon capture. Work for this project included membrane optimization and scale-up, module component screening and fabrication of high-temperature lab- and bench-scale modules, design and fabrication of a bench-scale field test membrane skid, operation of the field test skid processing coal-derived syngas at EERC, and a detailed techno-economic analysis (TEA) of the MTR dual-membrane process for IGCC power plant pre-combustion CO 2 capture. This project validated recent membrane technology advancements, mitigates risk in future scale-up activities, and moved the membrane pre-combustion capture technology from TRL-4 to TRL-5. Key results for each major task are discussed in the report.

10 SYNTHETIC FUELS↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗

Mitigating municipal solid waste fouling in biofuel conversion via screw surface modifications

Here, municipal solid waste (MSW)'s 40–60 % carbon content makes it a feedstock for biofuel production via pyrolysis. One challenge in the conversion process is MSW fouling due to thermal decomposition. The accumulated deposit on the injection screw often leads to plugging and constriction. This study examined the morphology and composition of the MSW fouling deposit and conducted a thermal simulation to understand the temperature gradience of the injection screw. Surface modifications including smoothening and anti-adhesion coating were proposed for the injection screw to address the deposit problem. For evaluating the candidate mitigations, a bench-scale fouling test was developed with the gas environment, temperature, and sliding speed relevant to the contact interface between the MSW particles and the screw. Results suggested that a smoother screw surface could reduce the grip and a non-metallic coating with a lower surface energy could decrease adhesion, consequently leading to less fouling. Specifically, reducing the roughness from 2 to 0.6 and then to 0.2 μm proportionally decreased the amount of deposit, and the diamond-like-carbon, CrN, and NiCr–CrC composite coatings effectively hindered the fouling process. This study provides fundamental insights into the MSW fouling and proof-of-concept of potential mitigations through the screw surface modification.

09 BIOMASS FUELS↗

Autoclave grid-to-rod fretting wear evaluation of a candidate cladding coating for accident-tolerant fuel

In pressurized water reactors (PWRs), water flow induced vibrations cause contact and rubbing between the fuel rods and the supporting grid, a phenomenon known as Grid-to-Rod-Fretting (GTRF). GTRF may produce progressive wear damage on the fuel claddings leading to subsequent leakage of radioactive fission products. Various accident-tolerant fuel (ATF) concepts are being developed for higher resistance to the high temperature steam and one approach is to apply a cladding coating. Here, fretting wear behavior of a candidate Cr-coating was investigated using a unique bench-scale autoclave testing rig mimicking the environment in an industrial full-assembly PWR simulator. The contact was under a realistically low load (~0.5 N) lubricated by deionized water at a temperature of 204 °C under a pressure of 20-23 bars. Results demonstrated that the Cr-coating significantly improved the cladding's wear resistance when tested against a commercial ZIRLO grid with or without pre-oxidization. In addition, the Cr-coating also reduced wear on the non-oxidized ZIRLO grid but slightly increased the wear on the pre-oxidized grid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Temperature Fe-Based Fischer–Tropsch Synthesis: Experimentally Validated Kinetic Models Implemented at Pellet and Reactor Scales

Pellet- and reactor-scale models for Fischer–Tropsch synthesis (FTS) with a Fe–K/silica catalyst were developed to investigate the sensitivity of the hydrocarbon products and carbon dioxide selectivity to process conditions and feed composition at high temperature (350–400 °C), moderate pressure (1–10 bar), and a range of H 2 /CO ratios (3–1). The major objective of this paper is to develop, validate, and evaluate a high-temperature FTS model that is then used to assess the feasibility of process integration with syngas production. Since there is limited kinetic data available, in literature at these conditions, bench-scale reactor tests were conducted to obtain operational data for parameter fitting of kinetic expressions used in the model. This resulting kinetic model demonstrated agreement with the experimental data with an R 2 of 0.97 to the testing data set and, thus, was feasible to apply at pellet and reactor scales. Here, multiple pellet sizes were modeled to detail the role of transport limitations as the sphere’s diameter approached and exceeded 1 mm. Application of the reactor model indicated that hydrocarbon selectivity depended strongly on temperature, whereas the ratio of olefin to paraffin products decreased with increasing temperature, pressure, and H 2 /CO ratio. Product selectivity was not sensitive to the conversion of carbon monoxide. Furthermore, the roles of the pressure and H 2 /CO ratio were closely coupled. At a H 2 /CO ratio of 3, only slight variations in selectivity occurred over a pressure range of 1–20 bar, whereas at a ratio of 1, selectivity could vary by as much as 30% over the same pressure range. At pressures below 5 bar and temperatures above 350 °C, minimal selectivity to heavy hydrocarbons (C 12+ ) is obtained, and selectivity to midrange products (C 5–11 ) rapidly declined as pressure dropped below 5 bar, which indicated that an operational pressure of at least 5 bar is needed to achieve reasonable yields in this temperature range. These results, while tentative, provide guidelines for further experimentation and evaluation of integrated FTS processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-invasive authentication of mail packages using nuclear quadrupole resonance spectroscopy

The international postal network is one of the most widely used methods for correspondence throughout the world. Most postal traffic across the globe consists of legitimate interpersonal, business-consumer, and business-business communications. However, the global postal system is also utilized for criminal activity. In particular, it is often utilized to ship and distribute contraband, including illegal psychoactive drugs such as fentanyl and heroin, to consumers. Existing technological solutions are capable of identifying synthetic opioids and other illegal drugs within packages, but are accompanied by several disadvantages that make them unsuitable for large-scale authentication of international mail traffic. This paper presents a novel method for non-invasive authentication of mail packages that overcomes these challenges. The approach uses nuclear quadrupole resonance (NQR) spectroscopy to detect and quantify the presence of known active pharmaceutical ingredients (APIs) within the package. It has been experimentally demonstrated using a bench top prototype. Test results from a variety of package types demonstrate the effectiveness of the proposed authentication approach.

42 ENGINEERING↗

Fiscal Year 2020 Filtration of Hanford Tank Waste 241-AP-105

Bench-scale filtration testing of 15 liters of 241-AP-105 supernatant was conducted using a Mott inline filter Model 6610 (media grade 5) backpulsed dead-end filter (BDEF) in the hot cells of the Radiochemical Processing Laboratory at Pacific Northwest National Laboratory. The as-received samples were diluted with raw water from the Hanford Site to assess the propensity for solids to form upon dilution and to assess the impact those solids have on filtration performance. The feed was split into two batches. The first batch was settled and decanted as planned in Tank Side Cesium Removal operations. The BDEF was used to filter this AP-105 feed at a targeted flux of 0.065 gpm/ft 2 and exhibited no measurable pressure increase during filtration. The second batch was fed to the BDEF with solids resuspended. This was also operated at the targeted flux of 0.065 gpm/ft 2 . In this case, the target pressure differential of 2 psid (resistance of 6.24 × 10 10 m -1 ) was reached in slightly more than 12 h. A backpulse restored the filter flux; however, the time to the next backpulse was slightly shorter. These tests indicate that after the addition of raw water, settle and decant effectively removed solids from the feed. It is not possible to assess the time required for these solids to settle based on the result from these tests. However, if sufficient time is allowed for the solids to settle, no measurable filter fouling was observed in current testing. In contrast, if insufficient time is allowed for solids to settle, filter fouling will occur relatively quickly and will likely require backpulses more frequently than every 12 hours (1.91 m 3 /m 2 volume filtered). Solids concentrated from backpulse solutions displayed large variability in composition with Al-silicates and mixed chromium-aluminum oxide phases. Amounts of Mg, Fe, and Ca were also found in the presence of Na and O. These solids could be grouped in three categories: (1) soluble Na-salts that formed large block-like particles but were made up of fibrous materials, (2) amorphous Al-phases, and (3) colloidal iron oxides with an average particle diameter of 4.2 µm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗