Search NASA⌕ Search

SEARCH · Search NASA

Results for “biosensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Molecularly Imprinted Polymer Sensor Empowered by Bound States in the Continuum for Selective Trace-Detection of TGF-beta

The integration of advanced materials and photonic nanostructures can lead to enhanced biodetection capabilities, crucial in clinical scenarios and point-of-care diagnostics, where simplified strategies are essential. Herein, a molecularly imprinted polymer (MIP) photonic nanostructure is demonstrated, which selectively binding to transforming growth factor-beta (TGF-β), in which the sensing transduction is enhanced by bound states in the continuum (BICs). The MIP operating as a synthetic antibody matrix and coupled with BIC resonance, enhances the optical response to TGF-β at imprinted sites, leading to an augmented detection capability, thoroughly evaluated through spectral shift and optical lever analogue readout. The validation underscores the MIP-BIC sensor capability to detect TGF-β in spiked saliva, achieving a limit of detection of 10 fM and a resolution of 0.5 pM at physiological concentrations, with a precision of two orders of magnitude above discrimination threshold in patients. The MIP tailored selectivity is highlighted by an imprinting factor of 52, showcasing the sensor resistance to interference from other analytes. The MIP-BIC sensor architecture streamlines the detection process eliminating the need for complex sandwich immunoassays and demonstrates the potential for high-precision quantification. This positions the system as a robust tool for biomarker detection, especially in real-world diagnostic scenarios.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Heterogeneous Multilayer Nanopores via Chemically Tuned Dielectric Breakdown for Single‐Molecule Sensing

Solid-state nanopores are powerful platforms for single-molecule sensing, yet their performance is often constrained by fabrication complexity, noise, and limited control over surface properties. Here we report a direct method to fabricate heterogeneous multilayer nanopores using chemically tuned controlled dielectric breakdown (CT-CDB). We integrate hBN, MoS 2 , or graphene atop a silicon nitride membrane to form five distinct bilayer and tri-layer architectures, with bare SiN x nanopore as a control. CT-CDB achieves pore formation reproducibly through material-stacks with high efficiency, good pore size control, and strong yield, validated by various characterizations. Transferrin protein translocation experiments, supported by simulations, reveal that multilayer configurations modulate protein conformations, ionic current blockade and dwell time distributions, reflecting combined effects of membrane type, interfacial chemistry, and local electric field gradients. A supervised machine learning framework is implemented to assist identifying multilayer structure effects embedded in signal signatures, with over 96% accuracy. This work presents a modular and scalable framework for functional nanopore engineering with complex structural integration, thereby expanding the potential of 2D materials in single-molecule sensing applications.

2D materials↗

Photocaged functional nucleic acids for spatiotemporal imaging in biology

Imaging of species in living organisms with high spatiotemporal resolution is essential for understanding biological processes. While functional nucleic acids (FNAs), such as catalytic nucleic acids and aptamers, have emerged as effective sensors for a wide range of molecules, photocaged control of these FNAs has played a key role in translating them into bioimaging agents with high spatiotemporal control. In this paper, we summarize methods and results of photocaged FNAs based on photolabile modifications, photoisomerization, and photothermal activation. Future directions, including strategies to improve the performance of these photocaged FNAs, are also described.

59 BASIC BIOLOGICAL SCIENCES↗

Advances in 3D Gel Printing for Enzyme Immobilization

Incorporating enzymes with three-dimensional (3D) printing is an exciting new field of convergence research that holds infinite potential for creating highly customizable components with diverse and efficient biocatalytic properties. Enzymes, nature’s nanoscale protein-based catalysts, perform crucial functions in biological systems and play increasingly important roles in modern chemical processing methods, cascade reactions, and sensor technologies. Immobilizing enzymes on solid carriers facilitates their recovery and reuse, improves stability and longevity, broadens applicability, and reduces overall processing and chemical conversion costs. Three-dimensional printing offers extraordinary flexibility for creating high-resolution complex structures that enable completely new reactor designs with versatile sub-micron functional features in macroscale objects. Immobilizing enzymes on or in 3D printed structures makes it possible to precisely control their spatial location for the optimal catalytic reaction. Combining the rapid advances in these two technologies is leading to completely new levels of control and precision in fabricating immobilized enzyme catalysts. The goal of this review is to promote further research by providing a critical discussion of 3D printed enzyme immobilization methods encompassing both post-printing immobilization and immobilization by physical entrapment during 3D printing. Especially, 3D printed gel matrix techniques offer mild single-step entrapment mechanisms that produce ideal environments for enzymes with high retention of catalytic function and unparalleled fabrication control. Examples from the literature, comparisons of the benefits and challenges of different combinations of the two technologies, novel approaches employed to enhance printed hydrogel physical properties, and an outlook on future directions are included to provide inspiration and insights for pursuing work in this promising field.

3D printing↗

Removal of Non-Specifically Bound Proteins Using Rayleigh Waves Generated on ST-Quartz Substrates

Label-free biosensors are plagued by the issue of non-specific protein binding which negatively affects sensing parameters such as sensitivity, selectivity, and limit-of-detection. In the current work, we explore the possibility of using the Rayleigh waves in ST-Quartz devices to efficiently remove non-specifically bound proteins via acoustic streaming. A coupled-field finite element (FE) fluid structure interaction (FSI) model of a surface acoustic wave (SAW) device based on ST-Quartz substrate in contact with a liquid loading was first used to predict trends in forces related to SAW-induced acoustic streaming. Based on model predictions, it is found that the computed SAW body force is sufficient to overcome adhesive forces between particles and a surface while lift and drag forces prevent reattachment for a range of SAW frequencies. We further performed experiments to validate the model predictions and observe that the excitation of Rayleigh SAWs removed non-specifically bound (NSB) antigens and antibodies from sensing and non-sensing regions, while rinsing and blocking agents were ineffective. An amplified RF signal applied to the device input disrupted the specific interactions between antigens and their capture antibody as well. ST-quartz allows propagation of Rayleigh and leaky SH-SAW waves in orthogonal directions. Thus, the results reported here could allow integration of three important biosensor functions on a single chip, i.e., removal of non-specific binding, mixing, and sensing in the liquid phase.

59 BASIC BIOLOGICAL SCIENCES↗

Phosphate binding protein as the biorecognition element in a biosensor for phosphate

This work explores the potential use of a member of the periplasmic family of binding proteins, the phosphate binding protein (PBP), as the biorecognition element in a sensing scheme for the detection of inorganic phosphate (Pi). The selectivity of this protein originates from its natural role which, in Escherichia coli, is to serve as the initial receptor for the highly specific translocation of Pi to the cytoplasm. The single polypeptide chain of PBP is folded into two similar domains connected by three short peptide linkages that serve as a hinge. The Pi binding site is located deep within the cleft between the two domains. In the presence of the ligand, the two globular domains engulf the former in a hinge-like manner. The resultant conformational change constitutes the basis of the sensor development. A mutant of PBP (MPBP), where an alanine was replaced by a cysteine residue, was prepared by site-directed mutagenesis using the polymerase chain reaction (PCR). The mutant was expressed, from plasmid pSD501, in the periplasmic space of E. coli and purified in a single chromatographic step on a perfusion anion-exchange column. Site-specific labeling was achieved by attaching the fluorophore, N-[2-(1-maleimidyl)ethyl]-7-(diethylamino)coumarin-3-carboxamide (MDCC), to the protein through the sulfhydryl group of the cysteine moiety. Steady-state fluorescence studies of the MPBP-MDCC conjugate showed a change in the intensity of the signal upon addition of Pi. Calibration curves for Pi were constructed by relating the intensity of the fluorescence signal with the amount of analyte present in the sample. The sensing system was first developed and optimized on a spectrofluorometer using ml volumes of sample. It was then adapted to be used on a microtiter plate arrangement with microliter sample volumes. The system's versatility was finally proven by developing a fiber optic fluorescence-based sensor for monitoring Pi. In all three cases the detection limits for the analyte were in the sub-microMolar range. It was also demonstrated that the sensing system was selective for phosphate over other structurally-similar anions, paving the way for the design and development of a new family of biosensors utilizing the specific binding properties of periplasmic proteins. c2003 Elsevier B.V. All rights reserved.

NASA Program Fundamental Space Biology↗

Molecular modeling of polymer composite-analyte interactions in electronic nose sensors

We report a molecular modeling study to investigate the polymer-carbon black (CB) composite-analyte interactions in resistive sensors. These sensors comprise the JPL electronic nose (ENose) sensing array developed for monitoring breathing air in human habitats. The polymer in the composite is modeled based on its stereoisomerism and sequence isomerism, while the CB is modeled as uncharged naphthalene rings with no hydrogens. The Dreiding 2.21 force field is used for the polymer, solvent molecules and graphite parameters are assigned to the carbon black atoms. A combination of molecular mechanics (MM) and molecular dynamics (NPT-MD and NVT-MD) techniques are used to obtain the equilibrium composite structure by inserting naphthalene rings in the polymer matrix. Polymers considered for this work include poly(4-vinylphenol), polyethylene oxide, and ethyl cellulose. Analytes studied are representative of both inorganic and organic compounds. The results are analyzed for the composite microstructure by calculating the radial distribution profiles as well as for the sensor response by predicting the interaction energies of the analytes with the composites. c2003 Elsevier Science B.V. All rights reserved.

NASA Center JPL↗

Array biosensor for detection of toxins

The array biosensor is capable of detecting multiple targets rapidly and simultaneously on the surface of a single waveguide. Sandwich and competitive fluoroimmunoassays have been developed to detect high and low molecular weight toxins, respectively, in complex samples. Recognition molecules (usually antibodies) were first immobilized in specific locations on the waveguide and the resultant patterned array was used to interrogate up to 12 different samples for the presence of multiple different analytes. Upon binding of a fluorescent analyte or fluorescent immunocomplex, the pattern of fluorescent spots was detected using a CCD camera. Automated image analysis was used to determine a mean fluorescence value for each assay spot and to subtract the local background signal. The location of the spot and its mean fluorescence value were used to determine the toxin identity and concentration. Toxins were measured in clinical fluids, environmental samples and foods, with minimal sample preparation. Results are shown for rapid analyses of staphylococcal enterotoxin B, ricin, cholera toxin, botulinum toxoids, trinitrotoluene, and the mycotoxin fumonisin. Toxins were detected at levels as low as 0.5 ng mL(-1).

Review↗

Community-level physiological profiling performed with an oxygen-sensitive fluorophore in a microtiter plate

Community-level physiological profiling based upon fluorometric detection of oxygen consumption was performed on hydroponic rhizosphere and salt marsh litter samples by using substrate levels as low as 50 ppm with incubation times between 5 and 24 h. The rate and extent of response were increased in samples acclimated to specific substrates and were reduced by limiting nitrogen availability in the wells.

NASA Discipline Life Support Systems↗

Nine-analyte detection using an array-based biosensor

A fluorescence-based multianalyte immunosensor has been developed for simultaneous analysis of multiple samples. While the standard 6 x 6 format of the array sensor has been used to analyze six samples for six different analytes, this same format has the potential to allow a single sample to be tested for 36 different agents. The method described herein demonstrates proof of principle that the number of analytes detectable using a single array can be increased simply by using complementary mixtures of capture and tracer antibodies. Mixtures were optimized to allow detection of closely related analytes without significant cross-reactivity. Following this facile modification of patterning and assay procedures, the following nine targets could be detected in a single 3 x 3 array: Staphylococcal enterotoxin B, ricin, cholera toxin, Bacillus anthracis Sterne, Bacillus globigii, Francisella tularensis LVS, Yersiniapestis F1 antigen, MS2 coliphage, and Salmonella typhimurium. This work maximizes the efficiency and utility of the described array technology, increasing only reagent usage and cost; production and fabrication costs are not affected.

NASA Discipline Life Sciences Technologies↗

Biosensors for DNA sequence detection

DNA biosensors are being developed as alternatives to conventional DNA microarrays. These devices couple signal transduction directly to sequence recognition. Some of the most sensitive and functional technologies use fibre optics or electrochemical sensors in combination with DNA hybridization. In a shift from sequence recognition by hybridization, two emerging single-molecule techniques read sequence composition using zero-mode waveguides or electrical impedance in nanoscale pores.

Review↗

Fabrication of poly(ethylene glycol) hydrogel microstructures using photolithography

The fabrication of hydrogel microstructures based upon poly(ethylene glycol) diacrylates, dimethacrylates, and tetraacrylates patterned photolithographically on silicon or glass substrates is described. A silicon/silicon dioxide surface was treated with 3-(trichlorosilyl)propyl methacrylate to form a self-assembled monolayer (SAM) with pendant acrylate groups. The SAM presence on the surface was verified using ellipsometry and time-of-flight secondary ion mass spectrometry. A solution containing an acrylated or methacrylated poly(ethylene glycol) derivative and a photoinitiator (2,2-dimethoxy-2-phenylacetophenone) was spin-coated onto the treated substrate, exposed to 365 nm ultraviolet light through a photomask, and developed with either toluene, water, or supercritical CO2. As a result of this process, three-dimensional, cross-linked PEG hydrogel microstructures were immobilized on the surface. Diameters of cylindrical array members were varied from 600 to 7 micrometers by the use of different photomasks, while height varied from 3 to 12 micrometers, depending on the molecular weight of the PEG macromer. In the case of 7 micrometers diameter elements, as many as 400 elements were reproducibly generated in a 1 mm2 square pattern. The resultant hydrogel patterns were hydrated for as long as 3 weeks without delamination from the substrate. In addition, micropatterning of different molecular weights of PEG was demonstrated. Arrays of hydrogel disks containing an immobilized protein conjugated to a pH sensitive fluorophore were also prepared. The pH sensitivity of the gel-immobilized dye was similar to that in an aqueous buffer, and no leaching of the dye-labeled protein from the hydrogel microstructure was observed over a 1 week period. Changes in fluorescence were also observed for immobilized fluorophore labeled acetylcholine esterase upon the addition of acetyl acholine.

NASA Discipline Life Sciences Technologies↗

A microarray immunoassay for simultaneous detection of proteins and bacteria

We report the development and characterization of an antibody microarray biosensor for the rapid detection of both protein and bacterial analytes under flow conditions. Using a noncontact microarray printer, biotinylated capture antibodies were immobilized at discrete locations on the surface of an avidin-coated glass microscope slide. Preservation of capture antibody function during the deposition process was accomplished with the use of a low-salt buffer containing sucrose and bovine serum albumin. The slide was fitted with a six-channel flow module that conducted analyte-containing solutions over the array of capture antibody microspots. Detection of bound analyte was subsequently achieved using fluorescent tracer antibodies. The pattern of fluorescent complexes was interrogated using a scanning confocal microscope equipped with a 635-nm laser. This microarray system was employed to detect protein and bacterial analytes both individually and in samples containing mixtures of analytes. Assays were completed in 15 min, and detection of cholera toxin, staphylococcal enterotoxin B, ricin, and Bacillus globigii was demonstrated at levels as low as 8 ng/mL, 4 ng/mL, 10 ng/mL, and 6.2 x 10(4) cfu/mL, respectively. The assays presented here are very fast, as compared to previously published methods for measuring antibody-antigen interactions using microarrays (minutes versus hours).

Non-NASA Center↗

Effect of surface roughness on liquid property measurements using mechanically oscillating sensors

The resonant frequency and quality factor Q of a liquid immersed magnetoelastic sensor are shown to shift linearly with the liquid viscosity and density product. Measurements using different grade oils, organic chemicals, and glycerol-water mixtures show that the surface roughness of the sensor in combination with the molecular size of the liquid play important roles in determining measurement sensitivity, which can be controlled through adjusting the surface roughness of the sensor surface. A theoretical model describing the sensor resonant frequency and quality factor Q as a function of liquid properties is developed using a novel equivalent circuit approach. Experimental results are in agreement with theory when the liquid molecule size is larger than the average surface roughness. However, when the molecular size of the liquid is small relative to the surface roughness features molecules are trapped, and the trapped molecules act both as a mass load and viscous load; the result is higher viscous damping of the sensor than expected. c2002 Elsevier Science B.V. All rights reserved.

Non-NASA Center↗

Smart medical systems with application to nutrition and fitness in space

Smart medical systems are being developed to allow medical treatments to address alterations in chemical and physiologic status in real time. In a smart medical system, sensor arrays assess subject status, which is interpreted by computer processors that analyze multiple inputs and recommend treatment interventions. The response of the subject to the treatment is again assessed by the sensor arrays, thus closing the loop. An early form of "smart medicine" has been practiced in space to assess nutrition. Nutrient levels are assessed with food frequency questionnaires, which are interpreted by flight surgeons to recommend inflight alterations in diet. In the future, sensor arrays will directly probe body chemistry. Near-infrared spectroscopy can be used to non-invasively measure several blood and tissue parameters that are important in the assessment of nutrition and fitness. In particular, this technology can be used to measure blood hematocrit and interstitial fluid pH. The non-invasive measurement of interstitial pH is discussed as a surrogate for blood lactate measurement for the development and real-time assessment of exercise protocols in space. Earth-based application of these sensors is also described.

NASA Discipline Life Sciences Technologies↗

Integrated CMOS photodetectors and signal processing for very low-level chemical sensing with the bioluminescent bioreporter integrated circuit

We report an integrated CMOS microluminometer optimized for the detection of low-level bioluminescence as part of the bioluminescent bioreporter integrated circuit (BBIC). This microluminometer improves on previous devices through careful management of the sub-femtoampere currents, both signal and leakage, that flow in the front-end processing circuitry. In particular, the photodiode is operated with a reverse bias of only a few mV, requiring special attention to the reset circuitry of the current-to-frequency converter (CFC) that forms the front-end circuit. We report a sub-femtoampere leakage current and a minimum detectable signal (MDS) of 0.15 fA (1510 s integration time) using a room temperature 1.47 mm2 CMOS photodiode. This microluminometer can detect luminescence from as few as 5000 fully induced Pseudomonas fluorescens 5RL bacterial cells. c2002 Elsevier Science B.V. All rights reserved.

Non-NASA Center↗

A comparison of imaging methods for use in an array biosensor

An array biosensor has been developed which uses an actively-cooled, charge-coupled device (CCD) imager. In an effort to save money and space, a complementary metal-oxide semiconductor (CMOS) camera and photodiode were tested as replacements for the cooled CCD imager. Different concentrations of CY5 fluorescent dye in glycerol were imaged using the three different detection systems with the same imaging optics. Signal discrimination above noise was compared for each of the three systems.

Evaluation Studies↗