Search NASA⌕ Search

SEARCH · Search NASA

Results for “building technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Utility Managed Distributed Energy Resources Intelligent Community - UDERMS iCommunity (Final Technical Report)

The Utility Managed Distributed Energy Resources Intelligent Community (UDERMS iCommunity) project, led by PacifiCorp and supported by the U.S. Department of Energy’s Building Technologies Office (Award No. DEEE0009782), aimed to demonstrate an integrated, utility-managed “behind-the-meter” distributed energy resource (DER) program connecting multifamily, commercial, institutional, and industrial buildings to deliver grid services and improve energy efficiency.

14 SOLAR ENERGY↗

Model America - data and models of every U.S. building

The 5-year goal of the 'Model America' concept was to generate a model of every building in the United States. This data repository delivers on that goal. Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM). There were 125,714,640 buildings detected in the United States and this dataset contains 122,930,327 (97.8%) buildings which resulted in a successful simulation. Future, annual updates have been proposed that may include additional buildings, data improvements, or other algorithmic enhancements. This dataset of 122.9 million buildings includes: Models (state_county.zip) - OpenStudio (v3.1.0) and EnergyPlus (v9.4) building energy models. Please note that the download requires the free Globus Connect Personal (https://www.globus.org/globus-connect-personal); Each model has approximately 3,000 building input descriptors that can be extracted. Please see the EnergyPlus(v9.4) 2,784-page Input/Output Reference Guide (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.4.0/InputOutputReference.pdf) for everything that can be retrieved or simulated from these models. These models were derived from the following metadata, which is not included in this dataset: 1. ID - unique building ID 2. County - county name 3. State - state name 4. CZ - ASHRAE Climate Zone designation 5. Clim_Zone - text label of climate zone 6. est_year - estimated year of construction 7. est_commercial - estimated building type (0=residential, 1=commercial) 8. Centroid - building center location in latitude/longitude (from Footprint2D) 9. Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) 10. Height - building height (meters) 11. Area2D - footprint area (ft2) 12. BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards 13. WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) 14. NumFloors - number of floors (above-grade) 15. Area - estimate of total conditioned floor area (ft2) 16. Standard - building vintage. These models are made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL) Laboratory Directed Research and Development (LDRD), U.S. Dept. of Energy's (DOE) Building Technologies Office (BTO), Office of Electricity (OE), Biological and Environmental Research (BER), and National Nuclear Security Administration (NNSA). This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. Please cite as: New, Joshua R., Adams, Mark, Bass, Brett, Berres, Anne, and Clinton, Nicholas (2021). 'Model America - data and models of every U.S. building. [Data set].' Constellation, doi.ccs.ornl.gov/ui/doi/339, April 14, 2021

24 POWER TRANSMISSION AND DISTRIBUTION↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Assessment of the Viability of Small Modular Reactors in Africa: A Nuclear Security and Nonproliferation Perspective

In response to escalating global energy demands driven by industrialization and the pressing need for decarbonization, this paper explores the potential of Small Modular Reactors (SMRs) as a sustainable energy solution in Africa. Focusing on nuclear security and non-proliferation concerns, the study assesses Africa's energy landscape, emphasizing the need for diverse and reliable power sources. While highlighting the scalability and cost-effectiveness of SMRs, the analysis acknowledges potential challenges associated with their introduction, particularly concerning nuclear security and non-proliferation. Given the recommendation to use High Assay Low Enriched Uranium (HALEU) in some SMRs, it is important to critically consider the security implications of transporting nuclear materials, the proximity of the public to the plant, and the time taken to respond to planned assaults. The possibility of using HALEU makes the nuclear material more prone to adversaries such as sabotage, theft, and terrorism. Utilizing PESTLE analysis, this research seeks to outline the detailed political, economic, social, technological, environmental, and legal readiness of Africa to embrace the first-of-a-kind technology (SMR) while fulfilling its mandate to the Non-Proliferation Treaty (NPT). Examining regulatory frameworks, international cooperation, and safety protocols, the study underscores the importance of regional collaboration to prevent the misuse of nuclear technology for military and malicious intent. Drawing insights from successful case studies, the paper concludes by synthesizing key findings and proposing recommendations for policymakers and stakeholders. These recommendations encompass regulatory enhancement, capacity building, technology transfer, and diplomatic efforts to strengthen nuclear security, non-proliferation, and safeguards in Africa.

Prah, Christina↗

ResStock: Annual Baseline Results with Component Loads

The ResStock Analysis Tool was developed by NREL with support from the U.S. Department of Energy to provide a new approach to large-scale residential analysis by combining large public and private data sources, statistical sampling, detailed sub hourly building simulations, and high-performance computing. This combination achieves unprecedented granularity and accuracy in modeling the diversity of the housing stock and the distributional impacts of building technologies in different communities. The annual baseline energy results from a national-scale ResStock run use typical meteorological year 3 (TMY3) files for energy simulations. Results include heating and cooling loads for individual components of each building. Component loads describe the heating/cooling load that can be attributed to specific elements of a home, such as heat transfer through walls or internal gains. Additionally, these results include the standard ResStock outputs for housing characteristics and numerous energy outputs by end-use and fuel. A snapshot of the ResStock version used to produce this data, including a configuration file for the run can be found using the Source Code resource link.

Array↗

Large-Amplitude Motion Platform: A New Ocean Simulator Can Help Technologies Succeed

Offshore renewable energy technologies - like wave energy devices, wind turbines, floating solar panels, and hybrid systems - can help decarbonize our power grids as well as offshore activities like international shipping and seafood farming. But it's not always easy to build technologies hearty enough to operate in a powerful ocean environment. And subjecting promising prototypes to real ocean waves can be an expensive, time-consuming, and risky way to get these technologies ready for the high seas. Now, with the National Renewable Energy Laboratory's (NREL's) new testing platform, called the large-amplitude motion platform (or LAMP for short), our experts can replicate powerful ocean waves in a low-risk laboratory setting. The LAMP, coupled with NREL's diverse array of testing instrumentation, can help technology developers rapidly hone their prototypes before embarking on a potentially costly and time-consuming ocean trial.

marine energy↗

Grid Planning for Building Electrification: A Report by the Energy Systems Integration Group’s Grid Planning for Building Electrification Task Force

The increased electrification of buildings across the United States is being driven by technical advancements, cost reductions for some building technologies, consumer preferences, and policy goals for decarbonization. However, the effects of this load growth on the electric distribution system are often only a minor consideration in policymaking and long-term planning studies. The long lead time and useful life of power system equipment means that the decisions taken today are expected to support our society well into the 2060s and beyond. Distribution planning stakeholders can take steps today to establish a grid foundation that captures the new challenges presented by building electrification. This report focuses on building electrification for the residential and commercial sectors, focusing most heavily on space heating, as this end use stands to most strongly impact demand.1 Across all end uses, building electrification could require somewhere between 10% and 70% more electricity generation capacity than exists today depending on technology adoption and energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2021 Thermal Energy Storage Systems for Buildings Workshop: Priorities and Pathways to Widespread Deployment of Thermal Energy Storage in Buildings

The 2021 U.S. Department of Energy's (DOE) "Thermal Energy Storage Systems for Buildings Workshop: Priorities and Pathways to Widespread Deployment of Thermal Energy Storage in Buildings" was hosted virtually on May 11 and 12, 2021. This report provides an overview of the workshop proceedings. Organized by DOE's Building Technologies Office (BTO), the National Renewable Energy Laboratory, Lawrence Berkeley National Laboratory, and Oak Ridge National Laboratory, the workshop convened more than 600 stakeholders from around the world to discuss the need for advancing the deployment of thermal energy storage (TES) in buildings. This workshop was designed to build on BTO's webinar series and 2019 workshop. The goals of this workshop were to promote discussion on TES related to: 1. Market adoption and deployment barriers, 2. Key applications and value drivers, 3. System cost, performance, and market requirements, and 4. End-use specific needs. The workshop took place over two days and consisted of keynote presentations, moderated panels, breakout sessions, and open discussion forums. The keynote presentations introduced opportunities for building TES, barriers to widespread deployment, and future visions. Moderated panel discussions presented diverse perspectives, breakout sessions provided opportunities for more intimate conversations, and open discussions captured feedback from the entire workshop group. Over the course of the two days, attendees exchanged experiences and ideas surrounding multiple aspects of TES in buildings. The first section of this report provides background on the motivations behind advancing TES for residential and commercial buildings and elaborates on the workshop objectives. The second section details the workshop structure and participant demographics. The third section provides key findings of the discussions that took place during the breakout sessions. Finally, this report details recommendations and actions to increase the TES deployment. Several recommendations from workshop attendees are presented in Table ES-1. TES holds significant potential to help increase building efficiency, grid-interactivity, and energy resilience, as well as reduce associated carbon emissions. The outputs generated from this workshop will aid stakeholders in advancing TES in buildings through a deeper understanding of the opportunities and barriers surrounding widespread deployment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model America - Arizona extract from ORNL's AutoBEM v1.1

Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM).Two sets of sample data are provided for 2,555,152 buildings located within the boundary of Arizona in the United States:Data (846.3MB *.csv) - minimalist list of each building (rows) for the following fields (columns) • ID - unique building ID • Centroid - building center location in latitude/longitude (from Footprint2D) • Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) • State_abbr - state name • Area - estimate of total conditioned floor area (ft2) • Area2D - footprint area (ft2) • Height - building height (ft) • NumFloors - number of floors (above-grade) • WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) • CZ - ASHRAE Climate Zone designation • BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards • Standard - building vintage • Sample Models (114GB*.zip by county) - OpenStudio and EnergyPlus building energy models named according to IDThis data is made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL), U.S. Dept. of Energy’s (DOE) Building Technologies Office (BTO), Office of Electricity (OE), and Biological and Environmental Research (BER).

54 ENVIRONMENTAL SCIENCES↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation Plan for Combined Heat and Power Systems VOLTTRON Controller: Performance Monitoring and Real-Time Commissioning Algorithm Verification

Building-integrated cooling, heating, and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV, and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of clean, efficient, reliable, and affordable next-generation integrated energy system. Previous report listed the components for which PM, real-time CxV, and AFDD algorithms will be developed, how the algorithms will be tested, and the metrics that will be used to validate the algorithms and their ease of deployment. Deployment of these algorithms in the field will result in a reduction in energy consumption of between 10% and 20% (for both CHP and conventional building systems). This report builds upon the previous report by detailing the process by which PNNL will implement performance monitoring and real-time commissioning algorithms for CHP systems in conjunction with the use of the VOLTTRON CHP economic dispatch agent in host facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifaceted Challenges and Opportunities Associated with Small Modular Reactors in Africa: A Nonproliferation Perspective

In response to the increasing global energy demands driven by industrialization and the urgent need for decarbonization, this study explores the potential of Small Modular Reactors (SMRs) as a sustainable energy solution in Africa. With a focus on nonproliferation concerns, the paper assesses Africa's energy landscape, emphasizing the need for diverse and reliable power sources. While highlighting the scalability and cost-effectiveness of SMRs, the analysis acknowledges potential challenges associated with adhering to the Nonproliferation Treaty with their mass deployment in the African continent. Examining regulatory frameworks, international cooperation, and security protocols, the study also underscores the importance of regional collaboration to prevent the misuse of nuclear technology for military and malicious purposes. The economic and geopolitical implications of SMR deployment in Africa are also investigated, considering its contributions to energy security and economic growth. Drawing insights from successful case studies, the paper concludes by synthesizing key findings and proposing recommendations for policymakers and stakeholders. These recommendations encompass regulatory enhancement, capacity building, technology transfer, and diplomatic efforts to strengthen nuclear security, nonproliferation, and safeguards. The overarching aim is to advocate for a balanced approach that maximizes the benefits of SMRs while mitigating associated risks to ultimately contribute to the sustainable and secure development of nuclear energy in Africa.

Prah, Christina↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Analysis and Grid Service Results for Commercial Buildings using the VOLTRON IoT Platform

In fiscal year 2021 (FY21), the Commercial Buildings Integration Program (CBI) within the Building Technologies Office (BTO), funded PNNL to conduct a field evaluation of the AIRCx and ILC using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load (beyond the traditional demand response) in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings opportunities (10% to 30%) as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective compared to a manual process in meeting the Re-tuning/retro commissioning (RCx) mandates and there is a pathway for broader adoption of this approach. This report provides AIRCx and ILC results for two building located in District of Columbia managed by the energy service provider Intellimation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward the renewables - A natural gas/solar energy transition strategy

The inevitability of an energy transition from today's non-renewable fossil base toward a renewable energy base is considered from the viewpoint of the need for a national transition strategy. Then, one such strategy is offered. Its technological building blocks are described in terms of both energy use and energy supply. The strategy itself is then sketched at four points in its implementation; (1) initiation, (2) early transition, (3) late transition, and (4) completion. The transition is assumed to evolve from a heavily natural gas-dependent energy economy. It then proceeds through its transition toward a balanced, hybrid energy system consisting of both centralized and dispersed energy supply technologies supplying hydrogen and electricity from solar energy. Related institutional, environmental and economic factors are examined briefly.

Hanson, J. A.↗

Data-driven occupant-behavior analytics for residential buildings

Many advances have been made in building technology to help save energy, but influencing the behavior of the occupants is still necessary to achieve low-energy use targets. One of the most practical ways to influence and change occupant behaviors is through incentives. Developing incentives for energy-saving and quantifying the impact of occupant behaviors are both active areas of research. Here, we propose a data analytics framework for detecting changes in occupant behaviors, which will help build an analytics feedback loop from behavior impact to incentive design. The framework has two major parts. The first forecasts energy consumption for each occupant, while the second determines a probability distribution for changes in energy consumption. The parts are interchangeable with other existing machine learning and statistical methods. A specific instantiation of the framework, using kernel ridge-regression for forecasting and k-means to find an empirical behavior distribution, is described in detail. An HVAC use-case with 5 different incentivized behaviors is used as an example to show that the framework can detect behavior changes induced by incentives. Furthermore, we show that some simpler behavior-change detection methods do not work, further justifying the use of advanced analytics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗