Search NASA⌕ Search

SEARCH · Search NASA

Results for “column separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Anion-exchange high-performance liquid chromatography with post-column detection for the analysis of phytic acid and other inositol phosphates

The use of gradient anion-exchange HPLC, with a simple post-column detection system, is described for the separation of myo-inositol phosphates, including "phytic acid" (myo-inositol hexaphosphate). Hexa-, penta-, tetra-, tri- and diphosphate members of this homologous series are clearly resolved within 30 min. This method should facilitate analysis and quantitation of "phytic acid" and other inositol phosphates in plant, food, and soil samples.

NASA Discipline Life Support Systems↗

The Influence of surface binding energy on sputtering in models of the sodium exosphere of Mercury

We have simulated the sodium (Na) exosphere of Mercury to show how the exosphere is affected by the assumed surface binding energy (SBE) of Na in the sputtered component. We constrained ion precipitation onto the surface using distributions for the cusp regions that are consistent with measurements by the MErcury Surface, Space ENvironment, GEochemistry, and Ranging Fast Imaging Plasma Spectrometer instrument. We have simulated sputtering with SBEs of 0.27, 2.6, 4.4, and 7.9 eV, with the lowest value commonly used in exosphere models and the highest from recent molecular dynamics calculations for the Na-bearing feldspar end-member, albite. A gradual change in the exosphere is seen as the yield decreases and the ejecta energy increases with increasing SBE. We describe the corresponding exosphere source functions for ion sputtering (IS), as well as for the previously studied processes of micrometeoroid impact vaporization and photon-stimulated desorption (PSD), along with their release energy distributions and spatial distributions. We have summed the contributions of the various source processes to explain how and when the different sources can be distinguished by observations. The modeled exosphere scale heights range from 72 km for PSD to over 1000 km for IS using a SBE of 7.9 eV. We find that the processes responsible for generating Mercury's Na exosphere are separable by measuring line-of-sight column densities tangent to the planet at various altitudes and positions around the planet. Our initial results are consistent with the Na being sputtered from a high-SBE material such as feldspar, which has been predicted to be abundant on the Mercury's surface.

Rosemary M. Killen↗

Quantifying Leak Rates and Vacuum Impact on Granular Soil Column Pneumatic Seal

Introduction: All In-Situ Resource Utilization (ISRU) regolith reactor systems that aim to extract gases or vapors must maintain a seal along the flow path of the regolith from the inlet hopper to where extracted gases or vapors are generated. Using a column of regolith at the inlet has been proposed as an alternative to systems using series of mechanical valves to reduce mass and complexity. Preliminary investigations into the use of regolith itself as a barrier to escaping fluids have been conducted, which this research seeks to expand upon. Different vertical regolith simulant plug diameters and heights were tested under vacuum with dry nitrogen to observe leak rates and approximate steady state pressure gradient equilibria. The effect of absolute ambient pressure was also studied by repeating tests at incremental pressures ranging from 10e-5 Torr up to 1 atm to corroborate ambient bench tests from previous work. The impact of regolith dynamics was addressed to emulate continuous-feed regolith reaction processes by measuring leak rates through continuously draining simulant columns. OB-1 lunar highlands regolith simulant was used. Experimental Setup: Regolith simulant columns were constructed using a motorized butterfly valve separating upper acrylic tubes of various diameters from a larger, lower aluminum pipe plenum (See Figure 1). The butterfly valve was cracked open such that gas could freely pass through whereas regolith would bridge and stay suspended as a cohesive plug above in the acrylic portion. These assemblies were loaded into a vacuum chamber, and a compressed dry nitrogen line was routed into the lower plenum. Pressure transducers measured the absolute pressure of the lower plenum, which was compared to absolute chamber pressure to monitor the pressure gradient across the regolith simulant. A precision mass flow controller enabled fine control of plenum pressure. The plenum pressure was quasi-statically increased to set points informed by previous work [1] before shutting off the gas supply to allow the now pressurized gas volume to dissipate through the simulant into the chamber in what was referred to as a ‘leak test.’ In a separate set of tests, the pressure was allowed to quasi-statically build until visual disturbances in the soil were observed via remote camera feeds. Initial leak rate tests were repeated on the disturbed soil to observe changes in leak rates between initial as-poured and post-bubbling soil conditions. This test schedule was applied to simulant columns of three different diameters (approximately 2, 4, and 6 inches) as well as two different heights (around 8 and 16 inches) and was repeated at least three times for each configuration. Plenums were also pressurized while the butterfly valves were opened slightly further to facilitate slow, controlled, constant flowrate draining of the simulant to observe the impact that continuous-feed systems might have on leak rate through the regolith column. Finally, the regolith columns were reset and refilled and static leak rate tests were repeated approximately every decade in ambient pressure from 10e-5 Torr up to ambient conditions to observe the impact of transitioning out of the molecular flow regime on regolith column seal performance. Analysis: Trends with respect to each factor examined were constructed and reported alongside commentary on the most likely responsible physical phenomena. Confidence intervals were applied to the predictive findings of the data by quantifying instrumentation error and accounting for probabilistic impacts of curve fitting the generic exponential function onto pressure decay data. The leak rate is assumed directly proportional to the exponential term coefficient, while the steady-state static pressure gradient is assumed to be the asymptotic limit of each curve fit. Finally, a generic model developed by Ogino et al. [2] and later tuned for ambient testing was re-tuned using vacuum data to estimate leak rates on the lunar surface. Results: Pressure decay rates decreased up to 27-fold under vacuum when compared to ambient pressure, as shown in Figure 2. Simulant column diameter was found to exponentially correlate to both regolith column leak rate and steady-state equilibrium pressure delta. Height was found to be linearly related to leak rate –doubling the regolith column height consistently yielded around a 40% reduction in leak rate. Dynamic regolith draining was found to slightly increase leak rate, although to a lower degree than expected. Conclusion: Because of the transition into molecular gas flow through regolith, vacuum testing is required to properly estimate performance. Regolith columns should be designed as narrow as possible to avoid bridging and minimize leak rate, and as tall as is feasible to both further reduce leak rate and to help prevent bubbling, which has been shown to degrade the quality of the regolith seal. Disrupted soil was found to exhibit higher leak rates than pristine, as-poured soil, indicating the need to consider the impact of recovery from depressurization events. Regolith columns appear equally feasible for both dosed and continuous-feed reactors.

ISRU↗

Chamber for Aerosol Deposition of Bioparticles

Laboratory apparatus is depicted that is a chamber for aerosol deposition of bioparticles on surfaces of test coupons. It is designed for primary use in inoculating both flat and three-dimensional objects with approximately reproducible, uniform dispersions of bacterial spores of the genus Bacillus so that the objects could be used as standards for removal of the spores by quantitative surface sampling and/or cleaning processes. The apparatus is also designed for deposition of particles other than bacterial spores, including fungal spores, viruses, bacteriophages, and standard micron-sized beads. The novelty of the apparatus lies in the combination of a controllable nebulization system with a settling chamber large enough to contain a significant number of test coupons. Several companies market other nebulizer systems, but none are known to include chambers for deposition of bioparticles to mimic the natural fallout of bioparticles. The nebulization system is an expanded and improved version of commercially available aerosol generators that include nebulizers and drying columns. In comparison with a typical commercial aerosol generator, this system includes additional, higher-resolution flowmeters and an additional pressure regulator. Also, unlike a typical commercial aerosol generator, it includes stopcocks for separately controlling flows of gases to the nebulizer and drying column. To maximize the degree of uniformity of dispersion of bioaerosol, the chamber is shaped as an axisymmetrical cylinder and the aerosol generator is positioned centrally within the chamber and aimed upward like a fountain. In order to minimize electric charge associated with the aerosol particles, the drying column is made of aluminum, the drying column is in direct contact with an aluminum base plate, and three equally spaced Po-210 antistatic strips are located at the exit end of the drying column. The sides and top of the chamber are made of an acrylic polymer; to prevent accumulation of electric charge on them, they are spray-coated with an anti-static material. During use, the base plate and the sides and top of the chamber are grounded as a further measure to minimize the buildup of electric charge.

Kern, Roger↗

Multi-Epoch XMM Observations of NGC4258

The goal of this project was detection of variability in the X-ray absorption column of the AGN in NGC4258 through monitoring with the XMM satellite. We have accomplished this goal and submitted the results to ApJ for publication in a paper entitled, "X-ray Luminosity and Absorption Column Fluctuations in the H2O Maser Galaxy NGC4258 from Weeks to Years," by Fruscione, A., Greenhill, L.J., Filippedco, A.V., Moran, J.M., Hermstein, J.R., and Galle, E. We have received a favorable referee report and expect the article will appear in 2005. To complete the project, we reduced our four epochs of XMM data for NGC4258, one archival XMM observation, and all existing Chandra datasets for NGC4258 (with the latest calibration tables and a grid of corrections for pileup). Self-consistent reduction of all these data permitted detailed comparison that could not have been accomplished simply by taking published model fits that appear in the literature. To accumulate a broader monitoring record, we combined the Chandra and XMM results with those published for SAX and ASCA. We modeled the Chandra and XMM data self-consistently with partially absorbed, hard power-law, soft thermal plasmas, and soft power-law components. Over nine years, the photo-electric absorbing column exhibited a 40% drop between two ASCA epochs separated by 3 years and a 60% rise between two XMM epochs separated by just 5 months. In contract, uncorrelated factor of of 2-3 changes were seen in absorbed flux on te timescale of years, which suggests intrinsic variability of the central engine. The warped disk that is a known source of H2O maser emission in 4258 is believed to cross the line of sight to the central engine. We have proposed that the variations in absorbing column arise from inhomogeneities in the rotating disk, as they sweep across the line of sight. We estimate from the XMM data that the inhomogeneities are about 1E+15 cm in size at radii greater than 0.27 pc. This is consistent with the estimated radius of the disk crossing estimated entirely independently, and it solidifies evidence that the warped accretion disk is the absorber in this (and possible other) AGN.

Greenhill, Lincoln J.↗

Development of polymeric coatings for control of electro-osmotic flow in ASTP MA-011 electrophoresis technology experiment

The development of a methyl cellulose based coating system for control of electro-osmotic flow at the walls of electrophoresis cells is described. Flight electrophoresis columns were coated with this system, resulting in a flight set of six columns. In flight photography of MA-011 electrophoretic separations verified control of electro-osmotic flow.

Patterson, W. J.↗

Space Shuttle Trace Gas Analyzer

A Trace Gas Analyzer (TGA) with the ability to detect the presence of toxic contaminants in the Space Shuttle atmosphere within the subparts-per-million range is under development. The design is a modification of the miniaturized Gas Chromatograph-Mass Spectrometer (GCMS) developed for the Viking Mars Lander. An ambient air sample is injected onto the GC column from a constant volume sample loop and separated into individual compounds for identification by the MS. The GC-MS interface consists of an effluent divider and a silver-paladium separator, an electrochemical cell which removes more than 99.99% of the hydrogen carrier gas. The hydrogen is reclaimed and repressurized without affecting the separator efficiency, a feature which enables a considerable weight reduction in the carrier gas supply system.

Dencker, W.↗

Laboratory corroboration of the Pioneer Venus gas chromatograph analyses

Laboratory simulation and tests of the inlet sampling system and columns of the Pioneer Venus gas chromatograph show that the sensitivity to argon is not diminished after the column regeneration step, that argon isotopes are not separated, that oxygen and sulfur dioxide are not produced in the inlet sampling system from sulfur trioxide, and that sulfur trioxide is not formed from sulfur dioxide and oxygen. Comparisons of the volatile inventory of Venus and earth imply similar efficiencies of early outgassing but a lower efficiency for later outgassing in the case of Venus. The high oxidation state of the Venus atmosphere in the region of cloud formation may prohibit the generation of elemental sulfur particles.

Oyama, V. I.↗

Variable-Resistivity Material For Memory Circuits

Nonvolatile memory elements packed densely. Electrically-erasable, programmable, read-only memory matrices made with newly-synthesized organic material of variable electrical resistivity. Material, polypyrrole doped with tetracyanoquinhydrone (TCNQ), changes reversibly between insulating or higher-resistivity state and conducting or low-resistivity state. Thin film of conductive polymer separates layer of row conductors from layer of column conductors. Resistivity of film at each intersection and, therefore, resistance of memory element defined by row and column, increased or decreased by application of suitable switching voltage. Matrix circuits made with this material useful for experiments in associative electronic memories based on models of neural networks.

Nagasubramanian, Ganesan↗

Explosive decomposition of hydrazine by rapid compression of a gas volume

In the present investigation of the initiation mechanism and the explosion mode of hydrazine decomposition, a 20 cm-long column of liquid hydrazine was accelerated into a column of gaseous nitrogen, from which it was separated by a thin Teflon diaphragm, in a close-ended cylindrical chamber. Video data obtained reveal the formation of a froth generated by the acceleration of hydrazine into nitrogen at the liquid hydrazine-gaseous nitrogen interface. The explosive hydrazine decomposition had as its initiation mechanism the formation of a froth at a critical temperature; the explosion mode of hydrazine is a confined thermal runaway reaction.

Bunker, R. L.↗

Thermal Desorption/GCMS Analysis of Astrobiologically Relevant Organic Materials

Several macromolecular organic materials, both biologically-derived (type II kerogen and humic acid) and abiotic in origin (Murchison insoluble organic material, cyanide polymer, and Titan tholin) were subjected to thermal desorption using a Chromatoprobe attachment on a Varian Saturn 2000 GCMS system. Each sample was heated sequentially at 100, 200, and 300 C to release volatile components. The evolved compounds were then separated on a Supelco EC-1 dimethylsilica GC column and detected by the Saturn 2000 ion trap mass spectrometer. The various types of macromolecular organic material subjected to thermal desorption produced distinctly different GCMS chromatograms at each temperature, containing fractions of both low and high chromatographic mobility. The relative amounts of detectable volatiles released at each temperature also differed, with type II kerogen and cyanide polymer containing the highest percentage of low-temperature components. In all the samples, the highest yield of released compounds occurred at 300 C. Only cyanide polymer evolved a homologous hydrocarbon series, suggesting that it is the only material among those examined that contains a truly polymeric structure. Pyrolysis/gas chromatography/mass spectrometry has been used extensively for analysis of terrestrial organic macromolecular materials, and was also part of the instrument package on the Viking landers. Thorough analysis by pyrolysis usually employs temperatures of 500 C or higher, which for in situ analyses can be problematic given spacecraft power and materials constraints. This study demonstrates that heating of organic materials of astrobiological relevance to temperatures as low as 200-300 C for short periods releases volatile components that can be analyzed by gas chromatography and mass spectrometry. Even in the absence of full pyrolysis, useful chemical information on samples can be obtained, and materials from different biological and abiological sources can be distinguished. The research described in this paper was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

McDonald, Gene D.↗

Observations of the Minor Species Al and Fe in Mercury's Exosphere

We report here on the first observational evidence of Al and Fe in the exosphere of Mercury, based on measurements of resolved emission lines of these metals with Keck-1/HIRES. Al emission was observed on two separate runs, in 2008 and 2013, with tangent column densities of 3.1 +/- 1.0 and 4.0 +/-1.5 x 10(exp 7) Al atoms cm(exp - 2) at altitudes of 1185 and 1870 km (1.5 and 1.75 R(sub M). The Al radiative intensity was seen to increase where the slit crossed the planetary penumbral shadow, and then decrease monotonically with altitude. Fe emission has been observed once, in 2009, indicating an extended source. We also present observed 3- Sigma Ca(+) upper limits near Mercury's equatorial anti-solar limb, from which an abundance limit of 4.0 x 10(exp 6) cm(exp -2) at 1650 km altitude is derived for the Ca ion. A simple model for zenith column abundances of the neutral species yields 1.9 -5.2 x 10(exp 7) Al cm(exp -2) , and 8.2 x 10(exp 8) Fe cm(exp -2) . The observations appear to be consistent with production of these species by impact vaporization, with a large fraction of the Al ejecta in molecular form, and that for Fe in mixed atomic and molecular forms. The scale height of the Al gas is consistent with a kinetic temperature of 6100-8000 K. The apparent high temperature and low density of the Al gas would suggest that it may be produced by dissociation of molecules.

Mercury↗

A31N-03: Lower-Tropospheric CO2 from Near-Infrared ACOS-GOSAT Observations

We present two new products from near-infrared GOSAT observations: lower tropospheric (LMT, from 0-2.5 km) and upper tropospheric/stratospheric (U, above 2.5 km) carbon dioxide partial columns. We compare these new products to aircraft profiles and remote surface flask measurements and find that the seasonal and year-to-year variations in the new partial columns significantly improve over the ACOS-GOSAT initial guess/a priori, with distinct patterns in the LMT and U seasonal cycles which match validation data. For land monthly averages, we find errors of 1.9, 0.7, and 0.8 ppm for retrieved GOSAT LMT, U, and XCO2; for ocean monthly averages, we find errors of 0.7, 0.5, and 0.5 ppm for retrieved GOSAT LMT, U, and XCO2. In the southern hemisphere biomass burning season, the new partial columns show similar patterns to MODIS fire maps and MOPITT multispectral CO for both vertical levels, despite a flat ACOS-GOSAT prior, and CO/CO2 emission factor consistent with published values. The difference of LMT and U, useful for evaluation of model transport error, has also been validated with monthly average error of 0.8 (1.4) ppm for ocean (land). The new LMT partial column is more locally influenced than the U partial column, meaning that local fluxes can now be separated from CO2 transported from far away.

Kulawik, Susan S.↗

Comparison of automated pre-column and post-column analysis of amino acid oligomers

It has been shown that various amino acids will polymerize under plausible prebiotic conditions on mineral surfaces, such as clays and soluble salts, to form varying amounts of oligomers (n = 2-6). The investigations of these surface reactions required a quantitative method for the separation and detection of these amino acid oligomers at the picomole level in the presence of nanomole levels of the parent amino acid. In initial high-performance liquid chromatography (HPLC) studies using a classical postcolumn o-phthalaldehyde (OPA) derivatization ion-exchange HPLC procedure with fluorescence detection, problems encountered included lengthy analysis time, inadequate separation and large relative differences in sensitivity for the separated species, expressed as a variable fluorescent yield, which contributed to poor quantitation. We have compared a simple, automated, pre-column OPA derivatization and reversed-phase HPLC method with the classical post-column OPA derivatization and ion-exchange HPLC procedure. A comparison of UV and fluorescent detection of the amino acid oligomers is also presented. The conclusion reached is that the pre-column OPA derivatization, reversed-phase HPLC and UV detection produces enhanced separation, improved sensitivity and faster analysis than post-column OPA derivatization, ion-exchange HPLC and fluorescence detection.

NASA Discipline Exobiology↗

Determination of Scopolamine in Human Saliva Using Solid Phase Extraction and LC/MS/MS

Purpose: Scopolamine is the preferred treatment for motion sickness during space flight because of its quick onset of action, short half-life and favorable side-effect profile. The dose administered depends on the mode of administration and usually ranges between 0.1 and 0.8 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids by using conventional HPLC methods. To measure scopolamine in saliva and thereby to evaluate the pharmacokinetics of scopolamine, we developed an LC/MS/MS method using off-line solid phase extraction. Method: Samples (0.5mL) were loaded onto Waters Oasis HLB co-polymer cartridges (10 mg, 1 mL) and eluted with 0.5 mL methanol without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 4 minutes. The mobile phase for separation was 90:10 (v/v) methanol: ammonium acetate (2 mM) in water, pH 5.0 +/- 0.1. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 yields 138.1 and internal standard (IS) hyoscyamine m/z = 290.2 yields 124.1. Results: The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at 1.7 and 3.2 min respectively. The linear range is 50-5000 pg/mL for scopolamine in saliva with correlation coefficients > 0.99 with a CV < 0.5 %. The intra-day and inter-day CVs are < 15 % for quality control samples with concentrations of 75, 300, 750 and 3000 pg/mL of scopolamine in human saliva. Conclusion: Solid phase extraction allows more rapid sample preparation and greater precision than liquid extraction. Furthermore, we increased the sensitivity and specificity by adjusting the LC mobile phase and using an MS/MS detector.

Wang, Zuwei↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Regolith Volatile Characterization (RVC) in RESOLVE

Resource investigation in the lunar poles is of importance to the potential impact of in-situ resource utilization (ISRU). The RESOLVE project developed a payload to investigate the permanently shadowed areas of the lunar poles and demonstrate ISRU technology. As a part of the RESOLVE project, the regolith volatile characterization (RVC) subsystem was designed to examine the release of volatiles from sample cores. The test sample was heated in the reactor to release the volatiles where they were analyzed with gas chromatography. Subsequently, the volatile sample was introduced into the lunar water resource demonstration (LWRD) subsystem where the released hydrogen and water were selectively captured. The objective of the Regolith Volatile Characterization (RVC) subsystem was to heat the crushed core sample and determine the desorption of volatile species of interest. The RVC subsystem encompasses the reactor and the system for volatile analysis. The system was designed to analyze H2, He, CO, CO2, N2, 02, CH4, H2S and H2O. The GC chosen for this work is a Siemens MicroSAM process GC with 3 columns and 8 TCD detectors. Neon was chosen as the carrier gas to enhance the analysis of hydrogen and helium.The limit of detection for the gases is approx.1000ppm for H2, CO. CO2 , N2, O2 and H2 S. The limit of detection for CH4 is approx.4000ppm and the water limit of detection is -10000 ppm with a sample analysis time of 2-3 minutes. These values (with the exception of water and H2S) were determined by dilution of a six gas mixture from Scott Gas (5% CO2, CO, O2, N2, 4% CH4 and H2) using mass flow controllers (MFC5). Water was calibrated at low levels using an in house relative humidity (RH) generator. H 2S and high concentrations of H2 were calibrated by diluting a pure stream of gas with MFCs. Higher concentrations of N2 and 02 were calibrated using Air again diluting with MFCs. There were three modification goals for the GC in EBU2 that would allow this process GC to be used in the field demo for RESOLVE. The first modification was to decrease the weight associated with the GC, this included eliminating the explosion proof case (Figure 1) and replacing it with a lightweight case as well as using an on board COPV tank for the neon carrier gas. The next goal was to add a second oven for the molecular sieve column to allow for dual temperature control during GC operation; the separation of hydrogen and helium is optimum at lower temperatures while the water analysis required higher temperatures creating a competing design requirement. The second oven also allows a lower limit of detection for water quantification and avoids the possibility of water condensing in the GC which could ruin the column characteristics. The final goal was to modify the column arrangement to optimize the system for our specific application. Figure 2 shows the internal details of the module optimized optimized for our field application. The modifications and performance of the gas analysis system will be discussed in detail.

Captain, Janine↗