Analysis and Testing of Optimal Power Control Strategy for NASA Moon Base Interconnected DC Microgrid System
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Safety analysis of power systems is concerned with the system's ability to maintain critical variables within specified limits following a disturbance. Frequency control adequacy has become increasingly important as the system inertia decreases due to the increase in renewable energy penetration. Various controllers for inverters have been proposed to improve the system frequency response and few are capable to ensure the safety of the response. In this article, a diesel-wind energy system is considered and modeled as a switching system between normal, faulted, and post-fault modes. Further, a safety feedback controller is designed as a supplementary signal for a wind turbine generator such that the speed of the diesel generator stays within a permissible range in the presence of a finite energy disturbance. Numerical results on the modified 33-bus microgrid system obtained of the proposed novel approach indicate that the suggested control configuration can guarantee adequate frequency response without excessive conservativeness.
Electric vehicle (EV) adoption will change the composition of EV charging load to higher-power charging as more medium- (MD) and heavy-duty (HD) applications are electrified, and as all vocations, including light-duty (LD) vehicles, are capable of faster charging. These shifts provide the opportunity for high-power charging (HPC) and facility equipment to evolve and improve efficiency, cost, and space. High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project designs and develops a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration approaches and technology solutions. The project addresses (1) interconnection and management of a grid-tied inverter; (2) development of a DC distribution system that is responsible for system energy management, interoperability, and DC protection; (3) modular DC/DC conversion for vehicle charging; (4) EV charging interface and DC/DC integration; and (5) smart charge control and vehicle-to-edge (vehicle-to-building [V2B], vehicle-to-everything [V2X]) capability. This summary presentation is the first technical progress output of the project. It provides insight for the first deep-dive technical meeting outputs in terms of research presentations and also includes summary of the discussions occurred in the follow-up breakout sessions. The summary presentation covers three technical areas: (1) HPC: State of the art power architectures and the design of the power electronics, (2) Modeling, energy management, and power control in the HPC station, and (3) Next Generation Profiles for high power charging characterization.
As the penetration of power-electronics based smart inverters (SIs) is increasing in distribution grids, it adds computational challenges in solving dynamic models of large-scale distribution feeders. Voltage and reactive power (Volt/VAr), and voltage and active power (Volt/Watt) dynamics have been analyzed at slower time scales akin to the control of legacy grid devices. However, smart inverters, being power-electronics based devices, can provide dynamic active/reactive power support at a faster time scale, which necessitates Volt/VAr and Volt/Watt dynamics to be analyzed at a faster time scale. The existing dynamic models are overly detailed and computationally intractable for distribution feeders with a large number of inverters. In this context, this proposed work aims towards developing a computationally tractable, scalable, and accurate phasor-based model for dynamic Volt/VAr and Volt/Watt analyses of large distribution systems with high penetration of smart inverters. Case studies demonstrate that the proposed phasor-based model sufficiently captures the Volt/VAr and Volt/Watt dynamics, and is computationally faster by one order of magnitude compared to the average model and by two orders of magnitude compared to the detailed switching model. Case studies also demonstrate the efficacy and scalability of the proposed model in analyzing Volt/VAr and Volt/Watt dynamics of large-scale power networks with hundreds of SIs.
Understanding the age of semiconductor parts being built into devices and systems is of interest for manufacturing quality control. Power spectrum analysis (PSA) is a fast, non-destructive, sensitive method for examining semiconductor parts. This talk will cover the use of multivariate analysis on both PSA data and conventional current-voltage data generated prior to PSA analysis to create algorithms that can be automated to screen semiconductor parts for aging.
Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 477 Report on the International Symposium on the Use of Probabilistic Safety Assessment for Operational Safety—PSA '91, S. Chakraborty and M. Khatib-Rahbar; 488 Good Relationships Are Pivotal in Nuclear Data Bases, A. S. Heger and B. V. Koen; 494 Technical Note: The Interagency Nuclear Safety Review Panel's Evaluation of the Ulysses Space Mission, J. A. Sholtis, Jr., D. A. Huff, L. B. Gray, N. P. Klug, and R. O. Winchester; ACCIDENT ANALYSIS: 502 The Severe Accident Analysis Program for the Savannah River Nuclear Production Reactors, M. L. Hyder; CONTROL AND INSTRUMENTATION: 511 A Framework for Selecting Suitable Control Technologies for Nuclear Power Plant Systems, R. A. Kisner; DESIGN FEATURES: 521 Containments for Gas-Cooled Power Reactors History and Status, P.W. Williams; ENVIRONMENTAL EFFECTS: 537 Indoor Radon: A Natural Risk, N. H. Harley and J.H. Harley; On the Importance of the Atmospheric Parameters in the Fission Products Distribution of a Severe Reactor Accident, M. C. Barla and A. R. Bayulken; Book Review: Health Effects of Exposure to Low Levels of Ionizing Radiation BEIR V, C. R. Richmond; WASTE AND SPENT FUEL MANAGEMENT: 555 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver OPERATING EXPERIENCES: 567 Effects of Component Aging on the Westhinghouse Control Rod Drive System, K. Sullivan and W. Gunther; 577 Reactor Shutdown Experience, Compiled by J. W. Cletcher, 580 Selected Safety-Related Events, Compiled by G. A. Murphy; 582 Operating U 8 Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver, RECENT DEVELOPMENTS: 596 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 610 Reports, Standards, and Safety Guides, D. S. Queener; 614 Proposed Rule Changes as of June 30, 1991; ANNOUNCEMENTS: 520 Workshop on PC PRAISE: A Probabilistic Fracture Mechanics Personal Computer Code for Nuclear Power Plant Piping Reliability Assessment; 536 Fifth Workshop on Nuclear Power Plant Containment Integrity; 624 New OECD "International Information System on Occupational Exposure (ISOE)"; 625 Harvard School of Public Health Announces Short Courses; 625 Eighth Power Plant Dynamics, Control and Testing Symposium; 626 Second Training Course on Off-Site Emergency Planning and Response for Nuclear Accidents; 618 The Authors; 622 Reviewers of Nuclear Safety, Vol 32.
The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.
This paper presents an analysis of voltage control strategies for heavy duty electric vehicle (EV) charging stations. The performance of three voltage control approaches including power factor control, preset volt-var curve control, and customized volt-var curve control, have been investigated and evaluated for three different sizes of charging stations, including single-port small charging station, three-port middle size charging station, and 6-port travel center. The charging stations have been placed on various locations of four different types of distribution systems, to obtain a comprehensive performance analysis of the three voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics have been designed to quantify the performance and contribute to the comprehensive analysis summary.
Cybersecurity is a persistent concern to the safety and security of Nuclear Power Plants (NPPs), but has lacked data-driven, evidence-based research. Rigorous cybersecurity analysis is critical for the licensing of advanced reactors using a performance-based approach. One tool that enables cybersecurity analysis is modeling and simulation. The nuclear industry makes extensive use of modeling and simulation throughout the decision process but lacks a method to incorporate cybersecurity analysis with existing models. To meet this need, the Advanced Reactor Cyber Analysis and Development Environment (ARCADE) was developed. ARCADE is a suite of publicly available tools that can be used to develop emulations of industrial control system devices and networks and integrate those emulations with physics simulators. This integration of cyber emulations and physics models enables rigorous cyber-physical analysis of cyber-attacks on NPP systems. This report provides an overview of key considerations for using ARCADE with existing physics models and demonstrates ARCADE’s capabilities for cybersecurity analysis. Using a model of the Small Modular Advanced High Temperature Reactor (SmAHTR), ARCADE was able to determine the sensitivity of the primary heat exchangers (PHX) to coordinated cyber-attacks. The analysis determined that while the PHX’s failures cause disruption to the reactor, they did not cause any safety limits to be exceeded because of the plant design, including passive safety features. Further development of ARCADE will enable rigorous, repeatable, and automated cyber-physical analysis of advanced reactor control systems. These efforts will also help reduce regulatory uncertainty by presenting similar types of cybersecurity analyses in a common format, driving standard approaches and reporting.
Research at the DIII-D National Fusion Facility in San Diego focuses on short pulse plasma discharges that specialize on various shaping profiles. High-speed data collection is a critical component for the operation of many of DIII-D’s diagnostics and is fundamental for capturing high-resolution data used in experimental data analysis. Differing techniques enable the plasma control system (PCS) to perform complex real-time feedback control on microsecond time scales. This work presents a comprehensive overview of data acquisition, focusing on the hardware and software used in reliable data acquisition at DIII-D. The robust nature of the data acquisition system allows for various techniques to coexist seamlessly. However, as modern systems capable of nanosecond resolution become more common, existing architectures will need to be modified. Here, by addressing the key challenges of high-speed data acquisition, DIII-D is able to provide real-time data used in plasma operation and has the ability to acquire high fidelity data needed for future experimental fusion reactors, such as ITER.
This article considers joint active power control of wind turbines and battery storage to follow a plant-level power reference signal. The joint control dynamically curtails the energy from a subset of the wind turbines and stores or withdraws energy from the battery to meet the power reference setpoint while accounting for wind plant aerodynamic interactions, such as wake losses. As a use case, we study the performance of the controller in maintaining a constant power output over hourly periods. A wind plant operating in this way would rely much less on other grid resources to meet its contractual agreements, thereby improving grid reliability, especially in grids with high penetration of wind and solar generation. We compare the operation of the wind plant under joint active power control to standard power-maximizing control with battery support. We present an analysis of the performance of the control system architecture. To study the impact of the battery size on performance, we simulate a 50-MW wind plant supported by batteries ranging from 8 to 64?MWh. We then evaluate the over and undergeneration penalties incurred by the plant during the simulation period.
In 1957 Glenn T. Seaborg conceived and advocated for the construction of the High Flux Isotope Reactor (HFIR) and the Transuranium Processing Plant (since then renamed the Radiochemical Engineering Development Center, or REDC) at Oak Ridge National Laboratory. There, heavily shielded hot cells, glove boxes, and laboratories allow recovery of transuranium elements produced in substantial quantities. Seaborg’s vision of HFIR and REDC producing milligram quantities of berkelium, californium, and einsteinium has been fulfilled beginning in 1966 through May 2019 with 78 production campaigns yielding a cumulative totals of 1.2 g of 249 Bk, 10.2 g of 252 Cf, 39 mg of 253 Es, and 15 pg of 257 Fm. Notably, 252 Cf is a neutron source used in many industrial applications including oil exploration; process control systems for the cement industry, coal analysis, and power production; sources to start nuclear reactors and perform nondestructive materials analyses; homeland security and national defense detection devices; and medical research. Isotopes made available through transplutonium production at HFIR/REDC have enabled scientists to study the nuclear properties and reactions, chemical properties, optical properties, and solid-state properties of transplutonium elements. Long-lived isotopes have served as targets in heavy ion accelerators to produce heavier elements leading to the discovery of 104 Rf, 105 Db, 106 Sg, 113 Nh, 114 Fl, 115 Mc, 116 Lv, 117 Ts, and 118 Og. This paper reviews the evolution of the processing flowsheets to produce, separate, and purify transplutonium isotopes, which have evolved over 50 years of operation at HFIR and REDC, and summarizes directions of future work to improve the efficiency of the production operations.
A high-voltage pulsed power supply (HVPPS) has been designed, prototyped, and tested for driving an eddy current actuated propellant valve for the International Thermonuclear Experimental Reactor (ITER) disruption mitigation system. The high-voltage (HV) dc supply output voltage is software programmable, and the energy storage capacitor bank can be readily reconfigured as 200, 400, 600, and 800 μ F, enabling testing and optimization of both the valve drive and valve systems. Multiple system parameters are monitored before, during, and after each firing of the valve. The system parameters are both displayed and stored for further analysis. Control of the setup, firing sequence, and data collection is automated using a LabVIEW-based control program. The programmability and reconfigurability of this system collectively provide a flexible and robust platform for system refinement and optimization. In this article, a summary of the system will be provided including operational sequences, HV switching and associated triggering methods and circuits, and results measured while firing a solid frozen pellet. Additionally, planned refinement activities toward meeting all requirements for ITER integration will be discussed.
The United States Department of Energy Advanced Reactor Technologies Program was formed in Fiscal Year 2015 and encompasses the Next Generation Nuclear Plant Project and Very High Temperature Reactor (VHTR) Program as they were known previously. The VHTR Program was created to support design and licensing of the first VHTR nuclear plant. Data created for and used by the program must be qualified for use, stored in a readily accessible electronic form, categorized to assure the correct data are used, and controlled to prevent data corruption or inadvertent changes. The Nuclear Data Management and Analysis System was designed to support the data needs of the VHTR Program, at the time and now the Advanced Reactor Technologies Program. Since its inception, use of the Nuclear Data Management and Analysis System has expanded to support additional projects and programs with similar requirements for control, analysis, and availability of large data sets.
This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases
Lidar-assisted control is a promising technology for reducing the levelized cost of energy from wind turbines, but quantifying its impact at the overall system level requires sophisticated systems engineering analysis and optimization frameworks. The joint workshop on Optimizing Wind Turbines with Lidar-Assisted Control Using Systems Engineering was held by the International Energy Agency Wind Task 32 (Lidar) and Task 37 (Systems Engineering) in October 2019 to address this challenge. This paper summarizes the outcome of the workshop and presents a road map for further research. The most promising applications of lidar-assisted control identified at the workshop and discussed here include 1) increasing annual energy production, 2) decreasing capital expenditure costs by reducing design loads, 3) extending turbine lifetime by reducing operating loads, and 4) enabling wind turbine class upgrades. For each application, we review the state of the art and highlight remaining research needs. Finally, we discuss strategies for addressing these research needs by conducting high-fidelity systems engineering optimizations.
Future nuclear fuel cycle facilities will see a significant benefit from considering materials accountancy requirements early in the design process. The Material Protection, Accounting, and Control Technologies (MPACT) working group is demonstrating Safeguards and Security by Design (SSBD) for a notional electrochemical reprocessing facility as part of a 2020 Milestone. The idea behind SSBD is to consider regulatory requirements early in the design process to provide more optimized systems and avoid costly retrofits later in the design process. Safeguards modeling, using single analyst tools, allows the designer to efficiently consider materials accountancy approaches that meet regulatory requirements. However, safeguards modeling also allows the facility designer to go beyond current regulations and work toward accountancy designs with rapid response and lower thresholds for detection of anomalies. This type of modeling enables new safeguards approaches and may inform future regulatory changes. The Separation and Safeguards Performance Model (SSPM) has been used for materials accountancy system design and analysis. This paper steps through the process of designing a Material Control and Accountancy (MC&A) system, presents the baseline system design for an electrochemical reprocessing facility, and provides performance metrics from the modeling analysis. The most critical measurements in the electrochemical facility are the spent fuel input, electrorefiner salt, and U/TRU product output measurements. Finally, material loss scenario analysis found that measurement uncertainties (relative standard deviations) for Pu would need to be at 1% (random and systematic error components) or better in order to meet domestic detection goals or as high as 3% in order to meet international detection goals, based on a 100 metric ton per year plant size.