Search NASA⌕ Search

SEARCH · Search NASA

Results for “cryogenic sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

ARM Data for Examining the Ice-Nucleating Particles from SGP Part II (ExINP-SGP II) Cryogenic Refrigerator Applied to Freezing Test

Knowledge of airborne particulate matter (PM), especially the particles that have supermicron diameters, is key for understanding ice-nucleating particles (INPs). Supported by the Atmospheric Radiation Measurement (ARM) user facility, we sampled PM and surface soil materials at the Southern Great Plains observatory (SGP; 36° 36′ 18″ N, 97° 29′ 6″ W) to systematically compare the INP abundance and ice nucleation efficiency of different SGP samples (i.e., airborne versus surface materials). The field campaign, named Examing INP from SGP II (ExINP-SGP II), was conducted from 20 January to 20 April, 2021. Our data analysis products include (1) physical surface sorption characterization data (i.e., BET, pore volume) of two sets of samples -- SGP Soil and USDA, (2) X-ray diffraction spectra for the same two samples, (3) immersion freezing assay-based ice nucleation active mass density data as a function of freezing temperature for both ambient and surface samples, and (4) time-series data of ambient meteorological conditions, concentration particle counter-derived aerosol particle concentration, and aerosol particle sizer measurement during ExINP-SGP II.

54 ENVIRONMENTAL SCIENCES↗

Absolute decay counting of 146 Sm with 4π cryogenic microcalorimetry

We present a methodology for absolute activity counting of long-lived isotopes based on cryogenic Decay Energy Spectroscopy. A 146 Sm source was produced at the TRIUMF Laboratory and then processed and purified at Lawrence Livermore National Laboratory, yielding a pure sample. The source was embedded within a 4π thermal absorber coupled to a magnetic microcalorimeter achieving nearly 100% counting efficiency. Experimental uncertainties were studied and modeled, including thermal coupling of the source to the absorber, pulse pile-up, trigger, and event selection efficiencies. Here, the absolute activity of the pure 146 Sm source was measured to better than 1% uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cryogenic heating system

The present invention relates to a cryogenic heating system including a plurality of stages to provide accurate temperature control. The system can be used to provide non-contact heating and cooling of a test sample by use of an inert fluid. Accurate temperature control can be maintained, e.g., by use of controllers to provide temperature feedback control.

42 ENGINEERING↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

The self-annealing of irradiation induced defects in magnetite Fe 3 O 4 : Revealing reversible irradiation-induced disorder transformation through in situ TEM

This work reports heavy ion-irradiation effects in polycrystalline Fe 3 O 4 . For this matter, Fe/Fe 3 O 4 heterostructures were irradiated in situ in a transmission electron microscopy with 1 MeV Kr ions at 50 K. Evidence of cubic to monoclinic transformation (a.k.a Verwey transition) was recorded in some magnetite grains upon cooling the sample (around 90 K); however, most of the oxide grains retain their cubic spinel structure. Irradiation effects were analyzed in the cubic phase up to a maximum dose of 38 dpa without the sign of amorphization. The extinction of first-order reflections was recorded at doses below 1 dpa, indicating the formation of a new (metastable) phase with half of the lattice parameters compared to the unirradiated Fe 3 O 4 crystal. The formation of the new crystalline phase, which also presents a high resistance to amorphization, is related to the disordering of the cation lattice and the high mobility of the cation interstitials. The metastable phase readily recovers around 225 K during the natural warming of the sample from 50 K to room temperature.

Atom irradiation effects↗

Composite pressure cell for pulsed magnets

We report that extreme pressures and high magnetic fields can affect materials in profound and fascinating ways. However, large pressures and fields are often mutually incompatible; the rapidly changing fields provided by pulsed magnets induce eddy currents in the metallic components used in conventional pressure cells, causing serious heating, forces, and vibration. Here, we report a diamond-anvil-cell made mainly out of insulating composites that minimizes inductive heating while retaining sufficient strength to apply pressures of up to 8 GPa. Any residual metallic component is made of low-conductivity metals and patterned to reduce eddy currents. The simple design enables rapid sample or pressure changes, desired by pulsed-magnetic-field-facility users. The pressure cell has been used in pulsed magnetic fields of up to 65 T with no noticeable heating at cryogenic temperatures. Several measurement techniques are possible inside the cell at temperatures as low as 500 mK.

47 OTHER INSTRUMENTATION↗

Coherent control and high-fidelity readout of chromium ions in commercial silicon carbide

Abstract Transition metal ions provide a rich set of optically active defect spins in wide bandgap semiconductors. Chromium (Cr 4+ ) in silicon-carbide (SiC) produces a spin-1 ground state with a narrow, spectrally isolated, spin-selective, near-telecom optical interface. However, previous studies were hindered by material quality resulting in limited coherent control. In this work, we implant Cr into commercial 4H-SiC and show optimal defect activation after annealing above 1600 °C. We measure an ensemble optical hole linewidth of 31 MHz, an order of magnitude improvement compared to as-grown samples. An in-depth exploration of optical and spin dynamics reveals efficient spin polarization, coherent control, and readout with high fidelity (79%). We report T 1 times greater than 1 s at cryogenic temperatures (15 K) with a T 2 * = 317 ns and a T 2 = 81 μs, where spin dephasing times are currently limited by spin–spin interactions within the defect ensemble. Our results demonstrate the potential of Cr 4+ in SiC as an extrinsic, optically active spin qubit.

74 ATOMIC AND MOLECULAR PHYSICS↗

Understanding In-Situ Structure and Chemistry at Battery Interfaces Through Time-Resolved Cryo-EM

Transmission and scanning transmission electron microscopy are vital tools for characterizing interfacial structure and chemistry at high spatial resolutions but are limited by the fact that many materials are quickly damaged by electron beam irradiation. This is a challenge particularly for materials relevant to energy applications, such as lithium-containing battery materials, organic-inorganic hybrids, and liquid electrolytes. Cryogenic electron microscopy (cryo-EM) offers a partial solution to this issue by stabilizing beam-sensitive solid-solid or solid-liquid interfaces for characterization, but typical cryo-EM sample preparations are ex situ and thus cannot capture interfaces in their electrified state of interest to applications. Here, we present a method to prepare cryo-EM samples of electrified battery interfaces in situ to preserve the time-resolved structures and chemistry that arise under applied current or bias.

batteries↗

Anti-reflection coating with mullite and Duroid for large-diameter cryogenic sapphire and alumina optics

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.1 and are highly reflective without an AR coating. This paper presents the design, fabrication, quality control, and measured performance of an AR coating using thermally sprayed mullite and Duroid 5880LZ. This technology enables large optical elements with diameters of 600 mm. We also present a thermography-based nondestructive quality control technique, which is key to assuring good adhesion and preventing delamination when thermal cycling. We demonstrate the average reflectance of about 2.6% (0.9%) for two observing bands centered at 90/150 (220/280) GHz. At room temperature, the average transmittance of a 105 mm square test sample at 220/280 GHz is 83%, and it will increase to 90% at 100 K, attributed to reduced absorption losses. Therefore, our developed layering technique has proved effective for 220/280 GHz applications, particularly in addressing dielectric loss concerns. This AR coating technology has been deployed in the cryogenic HWP and IR filters of the Simons Array and the Simons observatory experiments and applies to future experiments such as CMB-S4.

Sakaguri, Kana (ORCID:0000000156678118)↗

Dual-pace transient heat conduction in vertically aligned carbon nanotube arrays induced by structure separation

Vertically aligned arrays of carbon nanotubes (CNTs) are attractive for a wide range of macroscopic applications which can exploit the remarkable properties of individual nanotubes. In this work, an abnormal behavior of CNT bundles in heat conduction is discovered under the transient electro-thermal characterization. The measured voltage change over the sample shows a dual-pace thermal response (DTR), which could not be fitted using a single thermal diffusivity heat transfer model. Instead, two thermal diffusivities are determined from the DTR phenomenon. Three rounds of cryogenic experiments are conducted to investigate the physics behind DTR phenomenon. It starts to emerge when the temperature is reduced to a certain level. After two rounds of cryogenic experiments, the DTR phenomenon becomes permanent from 295 K to 10 K. The nano-scale structure separation induced by the increased thermal strain leads to macroscale structure separation, which results in two parallel heat conduction paths responsible for the DTR phenomenon. By building a new parallel heat transfer model taking both the transient and steady-state electrical and thermal response into consideration, the area ratio of separated CNTs is determined. Furthermore, this result uncovers the existence of coiled morphology and nano-structure evolution of CNTs under cryogenic state and its effect on thermal and electrical transport, especially on their transient behaviors. Knowledge of the thermal transport in these CNTs arrays is important considering the fact that transient thermal response strongly affects their mechanical, optical, and electrical behaviors.

42 ENGINEERING↗

Core plasma fueling by fast inward particle transport after hydrogen pellet injection in Wendelstein 7-X

A large database of more than 1000 individual cryogenic hydrogen pellets injected into Wendelstein 7-X for plasma fueling was analyzed to improve the understanding of the three phases of the process: the ablation, deposition and transport of the pellet material. Kilohertz-sampled electron density and temperature measurements revealed a more complex drift behavior than predicted by numerical code simulation. It could be explained by the poloidal plasma E r x B- drift rotation, which plays a significant role in stellarators, but was not previously considered in pellet injection codes like HPI2. The drift results in a fast poloidal rotation of the pellet material around the plasma core, leading to an almost homogeneous deposition over the involved flux surfaces regardless of magnetic high and low field side injection geometry. Additionally, a novel fast inward directed transport mechanism (‘FIT-effect’) was observed. The effect occurs on timescales of tens of milliseconds and cannot be explained by neoclassical transport or diffusion. It might be linked to the turbulence pinch recently found in Wendelstein 7-X. When the FIT-effect occurs, the pellet particles are rapidly transferred from the deposition flux surfaces to the plasma core, causing the plasma density profile to peak, which is beneficial for confinement in Wendelstein 7-X. The large pellet injection database was statistical analyzed with regard to pellet and plasma parameters, which delivered some starting points towards developing an understanding of the physics behind the FIT-effect. The results indicate, that plasma core fueling via pellet injection is largely independent of the injection geometry in stellarators under certain conditions, reducing the technical complexity of the injection system.

Wendelstein 7-X↗

NSUF RTE completion report for 23-4780: Microstructural Defect Induced Thermal Conductivity Reduction in Uranium Nitride and Thorium Nitride

Uranium nitride (UN) is known to have a higher thermal conductivity than traditional oxide fuels, which could lead to a more efficient energy transport and lower local temperature during its lifetime. But the thermal transport performance of UN in extreme environments has not been systematic studied. This study investigated the irradiation induced microstructural defects in UN and the impacts on thermal conductivity. The samples were produced by spark plasma sintering at University of Texas-San Antonio (UTSA), Los Alamos National Laboratory (LANL), and Idaho National Laboratory (INL). Thermal conductivity of UN before and after 2MeV proton irradiation were measured by using laser metrology at INL in a temperature range of 77-295K. Thermal conductivity measurements in this wide, cryogenic temperature range is critical to understand the phonon scattering mechanisms between the thermal energy carrier, phonons, and different types of irradiation-induced defects. In order to ensure the measurements were conducted in the same grains and minimize the impact of the local heterogeneities, the measurement locations were highlighted by fiducial marks using the focused ion beam (FIB) with grain orientation identified using the electron backscatter diffraction (EBSD) at the Center of Advanced Energy Studies (CAES). Irradiation experiment was conducted at the Ion Beam Laboratory at Texas A&M University (TAMU). A total of 6 samples were irradiated with different irradiation doses and temperatures. After irradiation, the microstructure was characterized by using Transmission Electron Microscope (TEM) at CAES (also in the FIB marks).

36 - MATERIALS SCIENCE↗

Genomic reconstruction of fossil and living microorganisms in ancient Siberian permafrost

Abstract Background Total DNA (intracellular, iDNA and extracellular, eDNA) from ancient permafrost records the mixed genetic repository of the past and present microbial populations through geological time. Given the exceptional preservation of eDNA under perennial frozen conditions, typical metagenomic sequencing of total DNA precludes the discrimination between fossil and living microorganisms in ancient cryogenic environments. DNA repair protocols were combined with high throughput sequencing (HTS) of separate iDNA and eDNA fraction to reconstruct metagenome-assembled genomes (MAGs) from ancient microbial DNA entrapped in Siberian coastal permafrost. Results Despite the severe DNA damage in ancient permafrost, the coupling of DNA repair and HTS resulted in a total of 52 MAGs from sediments across a chronosequence (26–120 kyr). These MAGs were compared with those derived from the same samples but without utilizing DNA repair protocols. The MAGs from the youngest stratum showed minimal DNA damage and thus likely originated from viable, active microbial species. Many MAGs from the older and deeper sediment appear related to past aerobic microbial populations that had died upon freezing. MAGs from anaerobic lineages, including Asgard archaea, however exhibited minimal DNA damage and likely represent extant living microorganisms that have become adapted to the cryogenic and anoxic environments. The integration of aspartic acid racemization modeling and metaproteomics further constrained the metabolic status of the living microbial populations. Collectively, combining DNA repair protocols with HTS unveiled the adaptive strategies of microbes to long-term survivability in ancient permafrost. Conclusions Our results indicated that coupling of DNA repair protocols with simultaneous sequencing of iDNA and eDNA fractions enabled the assembly of MAGs from past and living microorganisms in ancient permafrost. The genomic reconstruction from the past and extant microbial populations expanded our understanding about the microbial successions and biogeochemical alterations from the past paleoenvironment to the present-day frozen state. Furthermore, we provided genomic insights into long-term survival mechanisms of microorganisms under cryogenic conditions through geological time. The combined strategies in this study can be extrapolated to examine other ancient non-permafrost environments and constrain the search for past and extant extraterrestrial life in permafrost and ice deposits on Mars.

54 ENVIRONMENTAL SCIENCES↗

Optical interference for the guidance of cryogenic focused ion beam milling beyond the axial diffraction limit

Cryogenic focused ion beam (Cryo-FIB) milling has become a standard step in the cryogenic electron tomography (Cryo-ET) workflow and is required to thin cells to electron-semitransparency. However, this destructive process removes the vast majority of the cellular material and raises a critical question: what thin section should be preserved for Cryo-ET analysis? Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labeled structures with accuracy beyond the diffraction limit. Here we demonstrate this approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of amorphous ice. We then apply the approach to capture virions inside host cells. Successful targeting is confirmed by Cryo-ET revealing clusters of virions in intracellular vesicles. The method does not require any fluorescent fiducials or axial registration and can be performed on any fluorescently labeled structure that is visible in widefield fluorescence microscopy.

Cryoelectron microscopy↗

Compact in situ probe for magnetotransport measurements of 2D materials under variable tensile strain

The recent development of freestanding oxide membranes has opened new opportunities for strain engineering of transition metal oxides beyond values accessible in bulk samples. While a number of studies have been performed with fixed strain, the ability to dynamically control the strain state during measurement would be greatly enabling. To this end, we present an in situ uniaxial strain probe optimized for transport measurements of tensile-strained 2D or quasi-2D materials down to 2 K. Utilizing a flexible polyimide substrate as the stress transfer medium, our platform simplifies the sample preparation process and allows precise alignment of strain fields relative to the crystalline axes. An in situ optical microscope monitors the macroscopic strain state operando and makes it possible to complete an entire magnetotransport study at cryogenic temperatures under continuous strain variations. We demonstrate the capabilities of the probe on a freestanding LaNiO 3 membrane, where we induce tensile strain up to 8% and observe a corresponding strong transport anisotropy. In view of the rapid developments in low-dimensional materials synthesis and the plethora of novel quantum phenomena they exhibit, this strain probe provides general instrumentation for examining and controlling these properties via strain.

2D materials↗

Multiscale Cryo Electron Microscopy Reveals Interfacial Degradation and Stabilization in Battery Electrodes

Electrochemical interfaces are dynamic systems, evolving based on their local environment and reactant surface structures. The electrode-electrolyte interface in Li-ion batteries can be protective, limiting parasitic reactions with the electrolyte to passivate the surface [1]. Additionally, this interphase has an impact on the Li-ion transport through that layer based on its composition, bonding environment, and thickness. These parameters are challenging to collect and may vary depending on the electrode surface site investigated relative to its spatial position in a coin cell. This study will detail a multiscale cryogenic electron microscopy approach where millimeter-scale cross-sections through the coin cell batteries were made using a cryogenic stage within a fs-laser plasma focused ion beam (laser PFIB) with complementary energy dispersive X-ray spectroscopy able to detect variations in the composition at electrode interfaces [2]. Microscale cross-sectioning and lamella sample preparation of battery electrodes was conducted at the Center for Integrated Nanotechnologies using a Ga-ion focused ion beam (FIB) with air-free and cryo-transfer [3], followed by nanoscale mapping of composition and bonding within the CEI through cryo-scanning transmission electron microscopy (cryo-STEM) electron energy loss spectroscopy [4]. This multiscale approach enabled identification of millimeter-scale features of a battery stack with visualization of degradation in electrodes such as cracks in cathode particles, gas evolution, and SEI evolution; microscale interfacial characteristics, such as heterogeneity in the SEI or barrier layer and identification of electrolyte networks to the electrode surfaces; and nanoscale measurement of the CEI thickness, mapping of transition metal bonding within the cathode particles to identify loss of active materials, and identification of beneficial electrolyte additives incorporated into the CEI structure. This multiscale approach allows for a statistical understanding of the primary mechanisms and parasitic degradation pathways that impact performance by limiting the ion transport pathways within Li+ batteries.

36 MATERIALS SCIENCE↗

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Polarized tip-enhanced Raman spectroscopy at liquid He temperature in ultrahigh vacuum using an off-axis parabolic mirror

Tip-enhanced Raman spectroscopy (TERS) combines inelastic light scattering well below the diffraction limit down to the nanometer range and scanning probe microscopy and, possibly, spectroscopy. In this way, topographic and spectroscopic as well as single- and two-particle information may simultaneously be collected. While single molecules can now be studied successfully, bulk solids are still not meaningfully accessible. It is the purpose of the work presented here to outline approaches toward this objective. We describe a home-built, liquid helium cooled, ultrahigh vacuum TERS. The setup is based on a scanning tunneling microscope and, as an innovation, an off-axis parabolic mirror having a high numerical aperture of ~0.85 and a large working distance. The system is equipped with a fast load-lock chamber, a chamber for the in situ preparation of tips, substrates, and samples, and a TERS chamber. Base pressure and temperature in the TERS chamber were ~3 × 10 –11 mbar and 15 K, respectively. Polarization dependent tip-enhanced Raman spectra of the vibration modes of carbon nanotubes were successfully acquired at cryogenic temperature. The new features described here including very low pressure and temperature and the external access to the light polarizations, thus the selection rules, may pave the way toward the investigation of bulk and surface materials.

47 OTHER INSTRUMENTATION↗