Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Fermilab Italian Student Program (Final Report)

I participated to the 2019 Fermilab Italian Student Program under the supervision of Anadi Canepa and Lorenzo Uplegger. I worked with the Fermilab research group that is involved with the R&D of the CMS Outer Tracker. The Compact Muon Solenoid (CMS) is a a general-purpose detector located at the Large Hadron Collider (LHC), the world's most powerful particle accelerator. In the next years LHC will undergo the High-Luminosity LHC upgrade, which will bring its luminosity from 1 × 10 34 cm -2 s -1 to 1.5 × 10 34 cm -2 s -1 . This increase in luminosity will require an upgrade of CMS as well, in order to comply with the augmented rate of particles which will cross the detector. The CMS tracker is a detector, composed of various modules made of silicon pixel trackers and silicon strip trackers, whose aim is to reconstruct the trajectories of the particles produced by the collisions in LHC. The tracker is ideally divided in Inner Tracker and Outer Tracker. The HL-LHC upgrade put important challenges in the designing of the tracker. It will have to withstand the irradiation of a large fluence of particles, without suffering a too severe deterioration of its performance. In addition to this, in order to comply with the increased rate of events that CMS will need to detect, the tracker will be exploited for triggering at the fully hardware Level 1 Trigger, in contrast to the current tracker, whose data are only used for the software High-Level Trigger. This feature is managed by the "stub logic", which will be explained in chapter 2. During the months of August and September at Fermilab I carried out the data analysis of three test beam runs performed in the last two years on the 2S Outer Tracker Minimules. The 2S Minimoule consists of two silicon strip trackers placed one upon the other with the strips kept parallel.

43 PARTICLE ACCELERATORS↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Results and Limits of Time-Division Multiplexing for the BICEP Array High-Frequency Receivers

Time-division multiplexing is the readout architecture of choice for many ground and space experiments, as it is a very mature technology with proven outstanding low-frequency noise stability, which represents a central challenge in multiplexing. Once fully populated, each of the two BICEP Array high-frequency receivers, observing at 150 GHz and 220/270 GHz, will have 7776 TES detectors tiled on the focal plane. The constraints set by these two receivers required a redesign of the warm readout electronics. The new version of the standard multichannel electronics, developed and built at the University of British Columbia, is presented here for the first time. BICEP Array operates time-division multiplexing readout technology to the limits of its capabilities in terms of multiplexing rate, noise and cross talk, and applies them in rigorously demanding scientific application requiring extreme noise performance and systematic error control. Finally, future experiments like CMB-S4 plan to use TES bolometers with time-division/SQUID-based readout for an even larger number of detectors.

47 OTHER INSTRUMENTATION↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors

Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. Here in this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7–5.2 V/μm) and across a wide range of temperatures (77 K–290 K). This work shows that the first proof-of-principle windowless amorphous selenium device is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = lambda/Delta lambda = 300 on-chip superconducting filter-bank spectrometer covering the 120-180 GHz band for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

microstrip resonators↗

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

In this work, liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by γ interactions from 228 Th (2615 keV), 226 Ra (1764 keV), and 60 Co (1332 keV and 1173 keV) calibration sources, over a range of electric fields. The W value that defines the recombination-independent energy scale is measured to be 11.5±0.5 (syst.) ±0.1 (stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV scale, which deviate from extrapolations of lower-energy data. Additionally, a semiempirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double β -decay detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing Al quasiparticle diffusion using a positionable laser (Final Technical Report)

This Career Award accomplished most of its goals, in demonstrating for the first time a low- threshold nuclear recoil detector based on the quantum evaporation of helium-4. Through this work, we trained several PhD students and evolved this niche R&D topic into a central pillar of the DOE-funded TESSERACT project, which now plans to take underground helium data in 2028.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating charm quark energy loss in medium with the nuclear modification factor of D 0 -tagged jets

The nuclear modification factor R AA of charm jets, identified by the presence of a D 0 meson among the jet constituents, has been measured for the first time in Pb–Pb collisions at a centre-of-mass energy per nucleon pair $\sqrt{s_{NN}} = 5.02$ TeV with the ALICE detector at the LHC. The D 0 mesons and their charge conjugates are reconstructed from the hadronic decay D 0 → K – π + . Jets are reconstructed from D 0 -meson candidates and charged particles using the anti-k T algorithm with jet resolution parameter R = 0.3, in the jet transverse momentum (p T ) range 5 < $p^{ch}_{T}$$^{jet}$ < 50 GeV/c and pseudorapidity |η ch jet| < 0.6. A hint of reduced suppression in the charm-jet R AA is observed in comparison to inclusive jets in central Pb–Pb collisions with a significance of about 2σ in 20 < $p^{ch}_{T}$$^{jet}$ < 50 GeV/c, suggesting the in-medium energy loss to depend on both the difference between quark and gluon coupling strength (Casimir colour-charge effect) and quark mass (dead-cone effect). The data are compared with model calculations that include mass effects in the in-medium energy loss. Several state-of-the-art models are consistent with the data, with the LIDO model providing the best description of the data in the common kinematic range of inclusive and D 0 -tagged jets, highlighting the role of mass effects in interpreting the results.

Acharya, S. (ORCID:0000000292135329)↗

4-Dimensional Trackers

4-dimensional (4D) trackers with ultra fast timing (10-30 ps) and very fine spatial resolution (O(few $\mu$m)) represent a new avenue in the development of silicon trackers, enabling new physics capabilities beyond the reach of the existing tracking detectors. This paper reviews the impact of integrating 4D tracking capabilities on several physics benchmarks both in potential upgrades of the HL-LHC experiments and in several detectors at future colliders, and summarizes the currently available sensor technologies as well as electronics, along with their limitations and directions for R$\&$D.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Characterization for Quantitative Spectral Radiography of Uranium Powder Samples

Pacific Northwest National Laboratory (PNNL) is developing a prototype spectral x-ray radiography (SpecX) non-destructive assay system for noninvasive material mass quantification of uranium-bearing powders. The SpecX system uses a custom material estimation algorithm, which requires a high-fidelity pixel-by-pixel detector response model for accurate quantification. We performed a detailed characterization and built a model of a High-Energy X-ray Imaging Technology (HEXITEC) CdTe pixelated spectral detector. Here we present the detector characterization which led to that model, including a determination of the pixel-wise energy calibration, the detection efficiency, the detector uniformity, the detector stability, and a comparison of methods to remove charge-shared events.

spectral X-ray radiography, pixelated detector, ca↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗