Roadmap and Benchmarking: Privacy in Federated Load Forecasting

Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.

Abebe, Waqwoya [Oak Ridge National Laboratory (ORN

Radiative divertor detachment and impurity transport with nitrogen and neon seeding in KSTAR H-mode plasmas

Achieving core-edge compatible divertor detachment is a critical requirement for stable operation in future fusion devices. This study compares nitrogen and neon seeding in KSTAR H-mode plasmas with carbon walls, combining experiments and SOLPS-ITER modelling to evaluate their radiative dissipation and core-edge compatibility. Experimentally, N seeding achieved stronger divertor detachment, with larger reductions in target particle and heat fluxes, a higher divertor radiation fraction, and a lower core radiation fraction than Ne. In contrast, Ne seeding triggered a significant rise in core radiation followed by H–L back transitions, limiting the maximum total radiated power fraction to roughly half that of N. SOLPS-ITER simulations reproduced the experimental trends and revealed that the better core-edge compatibility of N arises from its higher divertor retention in addition to its higher cooling factor. The relative positions of the stagnation points of impurity poloidal velocity and ionization sources did not explain the different divertor compression. Instead, in the present modelling, the higher impurity parallel particle flux, resulting from the higher parallel impurity velocity, explains the stronger nitrogen impurity compression in the divertor region. The parallel temperature distribution with N was more favourable for achieving higher impurity parallel velocity than with Ne, because the impurity velocity is governed by modifications of the main ion flow due to friction and thermal forces, both of which strongly depend on the temperature. Ultimately, this behaviour is attributed to the strongly divertor-localized radiation of N. These results demonstrate that N is more effective than Ne in achieving radiative divertor detachment while maintaining low core contamination in KSTAR, consistent with observations in other present tokamaks.

KSTAR

Application of Ibuprofen Sodium Dihydrate for Thermochemical Energy Storage

Thermochemical energy storage (TCES) offers a transformative approach to address grid instability by harnessing reversible chemical reactions for efficient heat storage and release. Here, we introduce pharmaceutical organic salt hydrates as a class of materials with exceptional performance for low-grade waste heat recovery. We demonstrate ibuprofen sodium dihydrate (ISD) as an example organic hydrate exhibiting a dehydration temperature range of 60-110 °C and a remarkable dehydration enthalpy of up to 59.5 kJ/mol of water, ideally suited for capturing industrial and residential waste heat. Using rigorous multimodal characterization, including thermogravimetric analysis, differential scanning calorimetry, in-situ FTIR, in-situ PXRD, and NMR, we demonstrate ISD's superior thermal, chemical, and structural stability over 150 hydration-dehydration cycles, achieving an unprecedented cycling efficiency of ~99.9%. Compared to conventional inorganic salt hydrates like strontium chloride hexahydrate and calcium oxalate monohydrate, ISD showcases enhanced durability without deliquescence or pulverization, even under high-humidity conditions. In-situ analyses confirm the transition from ISD to ibuprofen sodium anhydrous (ISA) proceeds with structural reorganization, thereby combining the dehydration mechanism with phase transitions, resulting in higher energy storage capacity. Microstructural analyses reveal that repeated water intercalation and structural transitions aid in creating significant porosity that enhances water transport kinetics, further improving the hydration/dehydration performance. By combining the phase change and chemical dehydration mechanisms, ISD paves the way for designing a new class of organic salt hydrates, offering tunable properties to meet diverse thermal energy storage demands and supporting sustainable grid resilience.

Thangaraj, Kavin C.

Working Fluid Characterization and Performance Assessment of Subcritical Organic Rankine Cycles Based on the Lee–Kesler Approach for Energy Recovery

Here, a generalized model using the Lee–Kesler approach based on the corresponding states principle is developed to assess the performance of subcritical Organic Rankine Cycles operating with different working fluids. Each fluid is characterized by five parameters: the acentric factor, critical temperature, critical pressure, molar mass, and the ideal-gas ratio of specific heats at the critical temperature. The model was developed using the compressibility factor modified version of the Benedict–Webb–Rubin equation proposed by Lee and Kesler and the enthalpy and entropy functions to calculate thermodynamic state properties. The model was validated by comparing the results calculated with the model and working fluid thermodynamic properties obtained with the CoolProp database. This comparison was conducted for 91 working fluids, obtaining a relative error below 5% for 88 out of the 91 fluids (∼97%). A generalized parametric study was conducted to determine the influence of the pinch point and each fluid parameter on the performance of Organic Rankine Cycle (ORC) systems. It was found that efficiency increases with critical temperature, ideal-gas ratio of specific heats at the critical temperature, and acentric factor, reaching up to 13%. The developed model enables the evaluation of ORC system performance for existing working fluids. It also allows the formulation and evaluation of new fluids to enhance the performance of the ORC while retrieving energy from any kind of source; and likewise, the methodology can be applied to other power generation cycles.

24 POWER TRANSMISSION AND DISTRIBUTION

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD

Sodium-sulfur battery flight experiment definition study

Sodium-sulfur batteries are considered to be one of the most likely battery systems for space applications. Compared with the Ni-H2 or Ni-Co battery systems, Na-S batteries offer a mass reduction by a factor of 2 to 4, representing significant launch cost savings or increased payload mass capabilities. The Na-S battery operates at between 300 and 400 C, using liquid sodium and sulfur/polysulfide electrodes and solid ceramic electrolyte; the transport of the electrode materials to the surface of the electrolyte is through wicking/capillary forces. This paper describes five tests identified for the Na-S battery flight experiment definition study, which include the cell characterization test, the reactant distribution test, the current/temperature distribution test, the freeze/thaw test, and the multicell LEO test. A schematic diagram of Na-S cell is included.

Chang, Rebecca

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

Quantifying System Strength From Grid-Forming Resources Using Frequency Scan Approach: Preprint

Current industry practices for quantifying the system strength contribution from grid-forming (GFM) resources to ensure stability of power systems dominated by inverter-based resources (IBRs) are primarily based on iterative electromagnetic transient (EMT) time-domain simulation studies. While feasible, these approaches are resource-intensive, lack scalability and intuition, and might not evaluate the system strength contribution over the entire frequency range of interest. This paper introduces a novel, frequency-domain approach to quantify system strength support provided by a GFM resource using frequency scans. The proposed method uses transfer functions from the grid voltage magnitude (V) and phase (?), respectively, to the reactive (Q) and active power (P) output of a GFM resource for quantifying its contribution to system strength. These transfer functions provide a direct measure of the ability of a GFM resource to behave as a stiff voltage source behind a reactance over a specified frequency range, enabling robust quantification of its system strength contribution. The key innovation of this work is the development of a frequency domain system strength metric called the dynamic short-circuit ratio (dSCR) that is suitable for IBR-dominated power systems and is directly related with the familiar short circuit ratio (SCR) metric. The new metric, dSCR, enables the assessment of system strength contributions from both synchronous machines and converter-based GFM resources using a unified benchmark, which is not possible with the traditional SCR metric. The paper also demonstrates how impedance scans could identify if an unstable condition observed during weak grid conditions is a result of the lack active or reactive power support or both. By leveraging the proposed frequency-domain dSCR metric for quantifying system strength contribution from GFM IBRs, the paper demonstrates targeted mitigation strategies for weak grid instabilities without resorting to repeated, time-consuming time-domain simulations. The result is a scalable and efficient approach to remediate stability challenges in power systems with high shares of IBRs and accelerating the integration of GFM technologies for system strength support in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY

The effect of gamma ray irradiation on few layered MoSe2: A material for nuclear and space applications

In recent years, emerging two-dimensional (2D) materials, such as molybdenum diselenide (MoSe2), have been at the center of attention for many researchers. This is due to their unique and fascinating physicochemical properties that make them attractive in space and defense applications that include shielding harsh irradiation environments. In this study, we examined the effects of gamma (γ) rays at various doses on the structural, chemical, and optical properties of MoSe2 layers. After the samples were exposed to intense gamma radiation (from a 60Co source) with various exposure times to vary the total accumulated dosage (up to 100 kGy), Raman and photoluminescence spectroscopies were used to study and probe radiation-induced changes to the samples. When compared to pristine materials, very few changes in optical properties were typically observed, indicating good robustness with little sensitivity, even at relatively high doses of gamma radiation. The imaging using scanning electron microscopy revealed a number of nano-hillocks that were connected to substrate alterations. X-ray photoelectron spectroscopies revealed that Mo’s binding energies remained the same, but Se’s binding energies blueshifted. We associated this shift with the decrease in Se vacancies that occurred after irradiation as a result of Mo atoms creating adatoms next to Se atoms. When compared to pristine materials, very few changes in optical, chemical, and structural properties were typically observed. These findings highlight the inherent resilience of MoSe2 in hostile radioactive conditions, which spurs additional research into their optical, electrical, and structural characteristics as well as exploration for potential space, energy, and defense applications.

Materials Science

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)

Battery failure model derived from flaw theory

A previously derived failure model for battery lifetime is discussed in terms of growth rate of the flaw, distribution of flaw sizes, and number of flaws. Equations are presented for determining the failure model for a nickel cadmium battery.

Schulman, I.

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology

Magnetic and Dielectric Properties of Lunar Samples

The dielectric properties of lunar soil and rock samples show a systematic character when careful precautions are taken to ensure there is no moisture present during measurement. The dielectric constant (K) above 10 5 Hz is directly dependent on density according to the formula K = (1.93 ± 0.17) p where p is the density in g/cc. The dielectric loss tangent is only slightly dependent on density and has values less than 0.005 for typical soils and 0.005-0.03 for typical rocks. In addition to a density dependence, the loss tangent appears to be directly related to the metallic ilmenite content. These results are in good agreement with the results of the Surface Electrical Properties Experiment carried on Apollo 17. It showed a surface layer of dielectric constant 3.8 and a loss tangent of 0.008. This is presumed to be a layer of compact soil about 7 m thick, overlying a medium with a dielectric constant of roughly 7.5 and a loss tangent interpreted to be 0.035, The medium is presumed to be bedrock. These results are compatible with seismic results. The magnetic properties of lunar samples can be used to study the distribution of metallic and ferrous iron which shows systematic variations from soil-type to soil-type and a general tendency to increasing Fe°/Fe** distribution in the more highly rewelded breccias. The other magnetic characteristics can also be used to determine the distribution of grain sizes. There are a number of ways of interpreting the origin of the stable remanent magnetization in lunar samples, but several lines of evidence suggest that it is of thermal origin and was acquired at a time when the igneous rocks and breccias cooled from above 800°C in the presence of an ancient field.

D W Strangway

Surface Tension Driven Convection Experiment (STDCE)

Results are reported of the Surface Tension Driven Convection Experiment (STDCE) aboard the USML-1 (first United States Microgravity Laboratory) Spacelab which was launched on June 25, 1992. In the experiment 10 cSt silicone oil was placed in an open circular container which was 10 cm wide by 5 cm deep. The fluid was heated either by a cylindrical heater (1.11 cm dia.) located along the container centerline or by a CO 2 laser beam to induce thermocapillary flow. The flow field was studied by flow visualization. Several thermistor probes were placed in the fluid to measure the temperature distribution. The temperature distribution along the liquid free surface was measured by an infrared imager. Tests were conducted over a range of heating powers, laser beam diameters, and free surface shapes. In conjunction with the experiments an extensive numerical modeling of the flow was conducted. In this paper some results of the velocity and temperature measurements with flat and curved free surfaces are presented and they are shown to agree well with the numerical predictions.

S Ostrach

A Sensitivity-driven Wide Area Protection (SWAP) Coordination Tool for High Penetration of Inverter-based Resources (IBR)

Traditionally, power system generation sources have been composed of synchronous generators, of which the fault current behavior is understood with minimal differences between generation size and types due to the physics of their construction. Present protection schemes and modeling methods are based upon these understood characteristics. Most renewable generation is composed of inverter-based resources (IBR), in which fault current is determined by switching control software and hardware limitations, each of which can vary between manufacturers and even between models of the same manufacturer. The resulting fault current is low in magnitude, low in negative-sequence current, unpredictable phase angles, and is a challenge to model. These characteristics also result in a challenge to traditional protection schemes and fault simulation software. To address several of these concerns, the project has the following goals: 1. Improve IBR models: Improve IBR models used in short circuit (SC) programs to accurately capture the response of IBRs at the bulk power system (BPS) level for fault and protection studies. 2. Develop automation tool: Develop an automation tool that allows engineers to identify protection coordination and sensitivity issues by performing SC and protection coordination studies in a high IBR-penetrated grid by applying variations to the IBR models, faults, contingencies, etc. 3. Develop schemes: Develop new protection mitigation solution schemes that complement the existing protection systems to ensure safe operation of the BPS with higher IBR penetration levels. The project team did not achieve this final goal, as the Department of Energy (DOE) stopped the project early due to changes in DOE funding priorities. The termination notice came at the beginning of the final project phase, while the team was identifying and beginning to investigate protection issues. It should be noted that the team discussed a 100% penetration scenario. However, this scenario would require the use of grid-forming IBR models that are not presently available. Since developing these models requires additional effort, the 100% penetration scenario was not pursued during this project. In the future, developing the methodology and models for the 100% scenario could benefit the industry.

14 SOLAR ENERGY

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources