Search NASA⌕ Search

SEARCH · Search NASA

Results for “emission tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

PET Imaging of the Neurotensin Targeting Peptide NOTA-NT-20.3 Using Cobalt-55, Copper-64 and Gallium-68

Introduction: Neurotensin receptor 1 (NTSR1) is an emerging target for imaging and therapy of many types of cancer. Nuclear imaging of NTSR1 allows for noninvasive assessment of the receptor levels of NTSR1 on the primary tumor, as well as potential metastases. This work focuses on a the neurotensin peptide analogue NT-20.3 conjugated to the chelator NOTA for radiolabeling for use in noninvasive positron emission tomography (PET). NOTA-NT-20.3 was radiolabeled with gallium-68, copper-64, and cobalt-55 to determine the effect that modification of the radiometal has on imaging and potential therapeutic properties of NOTA-NT-20.3. Methods: In vitro assays investigating cell uptake and subcellular localization of the radiolabeled peptides were performed using human colorectal adenocarcinoma HT29 cells. In vivo PET/CT imaging was used to determine the distribution and clearance of the peptide in mice bearing NTSR1 expressing HT29 tumors. Results: Cell uptake studies showed that the highest uptake was obtained with [ 55 Co] Co-NOTA-NT-20.3 (18.70 ± 1.30%ID/mg), followed by [ 64 Cu] Cu-NOTA-NT-20.3 (15.46 ± 0.91%ID/mg), and lastly [ 68 Ga] Ga-NOTA-NT-20.3 (10.94 ± 0.46%ID/mg) (p < 0.001). Subcellular distribution was similar across the three constructs, with the membranous fraction containing the highest amount of radioactivity. In vivo PET/CT imaging of the three constructs revealed similar distribution and tumor uptake at the 1 h imaging timepoint. Tumor uptake was receptor-specific and blockable by co-injection of non-radiolabeled NOTA-NT-20.3. SUV ratios of tumor to heart at the 24 h imaging timepoint show that [ 55 Co] Co-NOTA-NT-20.3 (20.28 ± 3.04) outperformed [ 64 Cu] Cu-NOTA-NT-20.3 (6.52 ± 1.97). In conclusion, our studies show that enhanced cell uptake and increasing tumor to blood ratios over time displayed the superiority of [ 55 Co] Co-NOTA-NT-20.3 over [ 68 Ga] Ga-NOTA-NT-20.3 and [ 64 Cu] Cu-NOTA-NT-20.3 for the targeting of NTSR1.

60 APPLIED LIFE SCIENCES↗

Synthesis of fluorinated radiopharmaceuticals via electrochemical fluorination

Provided herein are methods and compositions for the electrochemical selective radiofluorination of aromatic molecules. The resulting fluorine-18 labeled compounds are ideal radionuclides for use in Positron Emission Tomography (PET); they are also difficult to radiolabel efficiently and with high specific activity using existing approaches. For example, radiopharmaceuticals such as [F18]L-DOPA, which is indispensable in PET brain disease imaging, may be made electrochemically with high radiochemical yield and high specific activity using 18F-. The invention process described herein opens new possibilities and provides wider access to PET tracers such as 18F-L-Dopa, since 18F- is much more widely available than the 18F2, currently used for synthesis of electron rich substrates.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gamma Ray Detection In Liquid Argon Time Projection Chambers

Gamma rays are photons in excess of 100 keV of energy and can be produced by a variety of mechanisms like radioactive decay and inelastic neutrino-argon interactions. A reconstruc- tion of Compton scattering gamma rays was developed for use in liquid argon time projection chambers. This reconstruction was tested with detectors developed to demonstrate the ca- pabilities of Deep Underground Neutrino Experiment (DUNE) Near Detector Liquid Argon target (ND LAr). In October 2024, a radioactive fluorine-18 source was placed next to the Full Scale Demonstrator. The data obtained was used to test this reconstruction algorithm. It was able to determine the direction of the photons with an error of less than 10 percent. In addition to this work, there has been significant work on designing a liquid argon based Positron Emission Tomography (PET) scanner. PET scanners detect gamma rays emitted by a tracer chemical to help screen for diseases like cancer. In addition to the applications to medical imaging, this thesis briefly explores the applications of this reconstruction to de-excitation photons produced in interactions between neutrinos and argon nuclei. These applications could improve studies focusing on neutrinos originating from accelerators and supernovae.

Murphy, Thomas [Syracuse U.]↗

Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies

Testing and qualification of advanced nuclear fuels involves an iterative process of prototyping, in-pile irradiation testing, and in-situ or ex-situ examination. Fuel restructuring and fission product migration during burnup are among the most important aspects of fuel evolution that affect several important performance characteristics such as heat removal, accident tolerance, and fission product retention. Pool-side non-destructive characterization techniques provide fuel developers with tools to understand fuel evolution at different points of burnup. A design for a compact, submersible, and multi-modal gamma-ray tomography system for imaging irradiated nuclear fuel is presented here. Detector selection, collimator geometry and fabrication, mechanical design, imaging protocol and acquisition speed are discussed. Modeling calculations show that sub-millimeter resolution can be achieved in both transmission computed tomography images as well as in emission computed tomography images in a matter of hours. Several design compromises and fabrication challenges are discussed which should be taken into consideration for future submersible gamma-ray tomography instruments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of 134 Ce as a PET imaging surrogate for antibody drug conjugates incorporating 225 Ac

The in vivo generator 134 Ce/ 134 La has the potential to serve as a PET imaging surrogate for both alpha-emitting 225 Ac and 227 Th radionuclides due to the unique Ce III /Ce IV redox couple and the relatively long half-life of 134 Ce. Furthermore, the purpose of this study was to demonstrate the compatibility of 134 Ce with DOTA-based antibody drug conjugates, which would act as therapeutic agents when incorporating 225 Ac.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coded aperture and Compton imaging for the development of 225 Ac‐based radiopharmaceuticals

Abstract Background Targeted alpha‐particle therapy (TAT) has great promise as a cancer treatment. Arguably the most promising TAT radionuclide that has been proposed is 225 Ac. The development of 225 Ac‐based radiopharmaceuticals has been hampered due to the lack of effective means to study the daughter redistribution of these agents in small animals at the preclinical stage. Purpose The ability to directly image the daughters, namely 221 Fr and 213 Bi, via their gamma‐ray emissions would be a boon for preclinical studies. That said, conventional medical imaging modalities, including single photon emission computed tomography (SPECT) based on nonmultiplexed collimation, cannot be employed due to sensitivity limitations. Methods As an alternative, we propose the use of both coded aperture and Compton imaging with the former modality suited to the 218‐keV gamma‐ray emission of 221 Fr and the latter suited to the 440‐keV gamma‐ray emission of 213 Bi. Results This work includes coded aperture images of 221 Fr and Compton images of 213 Bi in tumor‐bearing mice injected with 225 Ac‐based radiopharmaceuticals. Conclusions These results are the first demonstration of visualizing and quantifying the 225 Ac daughters in small animals through the application of coded aperture and Compton imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation studies of a full-ring, CZT SPECT system for whole-body imaging of 99m Tc and 177 Lu

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. With the goal of filling this technological gap, we have designed a cadmium zinc telluride (CZT) full-ring SPECT scanner instrumented with a broad-energy tungsten collimator. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT does not rely on the dual- and the triple-head rotational SPECT standard paradigm, enabling a larger effective area in each scan to increase the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized phantoms filled with 99m Tc and 177 Lu. Our SPECT design can resolve 7.9 mm rods for 99m Tc (140 keV) and 9.5 mm for 177 Lu (208 keV) in a hot-rod Derenzo phantom with a 3-min exposure and reach an image contrast of 78% for 99m Tc and 57% for 177 Lu using the NEMA IQ phantom with a 6-min exposure. Our modified scatter correction shows an improved contrast-recovery ratio compared to a standard correction. In this paper, we demonstrate the good performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99m Tc imaging of brain perfusion and 123 I imaging of dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design provides similar IQ and contrast to the commercial full-ring SPECT VERITON for 99m Tc. Regarding 177 Lu imaging of the 208 keV emissions, our design provides similar contrast to that of other state-of-the-art SPECTs with a significant reduction in exposure. In conclusion, the high sensitivity and extended energy range up to 250 keV makes our SPECT design a promising alternative for clinical imaging and theranostics of emerging radionuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of a Variable-Aperture Full-Ring SPECT System using Large-Area Pixelated CZT Modules: A Simulation Study for Brain SPECT Applications

Single photon emission computed tomography (SPECT) scanner using cadmium zinc telluride (CZT) offers improved imaging capability over conventional NaI (Tl)-based SPECT scanner. We aim to demonstrate a full-ring SPECT system design with eight large-area CZT detectors that can be used for a broad spectrum of SPECT radiopharmaceuticals and provides higher sensitivity and better spatial resolution than those of conventional NaI (Tl)-based gamma cameras. A newly-designed full-ring SPECT system is composed of 8 large-area CZT cameras (128 mm × 179.2 mm effective area) that can be independently swiveled around their own axes of rotation independently and can have radial motion for varying aperture sizes that can be adapted to different sizes of imaging volume. Extended projection data were generated by conjoining projections of two adjacent detectors to overcome the limited field-of-view (FOV) by each CZT camera. Using Monte Carlo simulations, we evaluated this new system design with digital phantoms including a Derenzo hot-rod phantom and a Zubal brain phantom. Comparison of performance metrics such as spatial resolution, sensitivity, contrast-to-noise ratio (CNR), and contrast-recovery ratio were made between our design and a conventional SPECT scanner. The proposed scanner could result in up to about 3 times faster in acquisition time over conventional scan time at same acquisition time per step. The spatial resolution of our proposed scanner was similar or better to that of the conventional scanner, and there was significant performance improvement over the conventional scanner particularly in sensitivity (approximately 4 times). Overall, we successfully reconstructed the phantom image for both 99 mTc-based perfusion and 123 I-based dopamine transporter (DaT) brain studies simulated for our new design. In particular, the striatal/background contrast-recovery ratio in 3-to-1 reference ratio was over the 0.8 for the 123 I-based DaT study. In conclusion, we demonstrated the potential of our new full-ring CZT SPECT design, showing improved performance metrics such as improved system sensitivity and CNR while maintaining other important imaging parameters such as spatial resolution.

36 MATERIALS SCIENCE↗

Preliminary investigation of 48 V-labeled VO(acac) 2 for cancer imaging: An initial proof-of-concept study

In this preliminary study, a procedure for synthesizing novel PET radiotracer vanadium-48-labeled-vanadyl acetylacetonate was developed, including radioisotope production via cyclotron, separation of 48 V, chelation as 48 VO(acac) 2 , and assessment through in vitro cellular studies. We employed the beam-stop setup in a cyclotron as the target holder to irradiate titanium foils in the reaction of nat Ti (p,n) 48 V. The radioisotope production rate was 4.84 ± 0.67 μCi/μA-h. Overall radiochemical yield was 12.86 ± 0.51% with gamma-ray spectroscopy showing no detectable contaminant peaks. HPLC of 48 VO(acac) 2 showed a retention time (1:48) corresponding closely to that (1:50) of commercial VO(acac) 2 , verifying the successful synthesis of 8VO(acac) 2 . In vitro cellular studies demonstrated radiotracer uptake and saturation around 0.48 nM. These studies pave the way for improving methodologies and in vivo experiments, including imaging studies, in future investigations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of the 70 Ge( d , n ) 71 As cross section from 2.1 MeV to 10 MeV

This work reports experimental 70 Ge(d,n) 71 As cross sections producing Arsenic-71 (t 1/2 = 65.3 h, 28% β + ), a potentially useful diagnostic radionuclide. Target stacks containing two nat Ge foils, a nat Ni monitor foil, and an Al degrader were irradiated with 5.5–10 MeV deuterons using an FN Tandem Van de Graaff accelerator. 71 As and 61 Cu, 56 Co, and 58 Co (from nat Ni(d,x)) were quantified in the foils by high purity germanium gamma spectrometry. Furthermore, the measured cross sections are larger than previously reported and suitable for producing preclinical quantities of diagnostic radiopharmaceuticals.

07 ISOTOPE AND RADIATION SOURCES↗

Nondestructive neutron imaging diagnosis of acidic gas reduction catalyst after 400-Hour operation in natural gas furnace

Residential natural gas furnaces are the primary space-heating devices in US homes, leading to substantial environmental impact caused by the acidic components in the furnace combustion gases. Here, to experimentally demonstrate acidic gas reduction in a furnace, a monolithic catalyst was fabricated and was called the AGR. A commercially-available condensing furnace was retrofitted with the AGR, and a 400-hour reliability and durability test was conducted. The results showed that the AGR significantly reduced acidic gases in the flue gas and produced condensate with neutral pH. Challenges were also revealed: inappropriate condensate drainage caused incomplete combustion and amorphous carbon deposits. To nondestructively survey the internal state of the AGR, neutron computed tomography (NCT) was employed to produce spatially resolved 2D and 3D representations of the 2-L, aged AGR component. The NCT results confirm the integrity of the AGR component, which consists of two blocks, without deformation or damage to AGR channels. The distribution of the particle accumulation in the middle of the top block was visibly heavier than the entrance and exit of the top block. The representative cross-section views revealed significant aggregation in the central region but not at the rim. The spatially resolved details provide in-depth diagnosis, evaluation, and understanding of the AGR. The insights can enable new AGR designs that realize a uniform and self-cleaning flow pattern, alleviate significant particle aggregation, and thus enhance AGR-enabled furnace performance. The neutron imaging method demonstrates the good potential that can diagnose faults and improve the design, optimization, and production processes of novel catalysts and other components or systems with heavy metal shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Excitation function of 54 Fe(p, α ) 51 Mn from 9.5 MeV to 18 MeV

Excitation function of the 54 Fe(p,α) 51 Mn reaction was measured from 9.5 to 18 MeV $E_{0,p^+}$ by activating a foil stack of 54 Fe electrodeposited on copper substrates. Residual radionuclides were quantified by HPGe gamma ray spectrometry. Both 51 Mn ($t_{1/2}$ = 46.2 min, $\langle E_{β^+}\rangle$=963.7keV, $I_{β^+}$ = 97%; $E_γ$ = 749.1keV, $I_γ$ = 0.265%) and its radioactive daughter, 51 Cr ($t_{1/2}$ = 27.704d, $E_γ$ = 320.1 keV, $I_γ$ = 9.91%), were used to indirectly quantify formation of 51 Mn. Results agree within uncertainty to the only other measurement in literature and predictions of default TALYS theoretical code. Final relative uncertainties are within ±12%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preclinical studies of a PARP targeted, Meitner-Auger emitting, theranostic radiopharmaceutical for metastatic ovarian cancer

Advanced ovarian cancer currently has few therapeutic options. Poly(ADP-ribose) polymerase (PARP) inhibitors bind to nuclear PARP and trap the protein-inhibitor complex to DNA. This work investigates a theranostic PARP inhibitor for targeted radiopharmaceutical therapy of ovarian cancer in vitro and PET imaging of healthy mice in vivo. Methods: [ 77 Br]RD1 was synthesized and assessed for pharmacokinetics and cytotoxicity in human and murine ovarian cancer cell lines. [ 76 Br]RD1 biodistribution and organ uptake in healthy mice were quantified through longitudinal PET/CT imaging and ex vivo radioactivity measurements. Organ-level dosimetry following [ 76/77 Br]RD1 administration was calculated using RAPID, an in-house platform for absorbed dose in mice, and OLINDA for equivalent and effective dose in human. Results: The maximum specific binding (B max ), equilibrium dissociation constant (K d ), and nonspecific binding slope (NS) were calculated for each cell line. These values were used to calculate the cell specific activity uptake for cell viability studies. The half maximal effective concentration (EC 50 ) was measured as 0.17 (95 % CI: 0.13–0.24) nM and 0.46 (0.13–0.24) nM for PARP(+) and PARP(–) expressing cell lines, respectively. The EC 50 was 0.27 (0.21–0.36) nM and 0.30 (0.22–0.41) nM for BRCA1(–) and BRCA1(+) expressing cell lines, respectively. When measuring the EC 50 as a function of cellular activity uptake and nuclear dose, the EC 50 ranges from 0.020 to 0.039 Bq/cell and 3.3–9.2 Gy, respectively. Excretion through the hepatobiliary and renal pathways were observed in mice, with liver uptake of 2.3 ± 0.4 %ID/g after 48 h, contributing to estimated absorbed dose values in mice of 19.3 ± 0.3 mGy/MBq and 290 ± 10 mGy/MBq for [ 77 Br]RD1 and [ 76 Br]RD1, respectively. Conclusion: [ 77 Br]RD1 cytotoxicity was dependent on PARP expression and independent of BRCA1 status. Finally, the in vitro results suggest that [ 77 Br]RD1 cytotoxicity is driven by the targeted Meitner-Auger electron (MAe) radiotherapeutic effect of the agent. Further studies investigating the theranostic potential, organ dose, and tumor uptake of [ 76/77 Br]RD1 are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanisms of Polyethylene Terephthalate Pellet Fragmentation into Nanoplastics and Assimilable Carbons by Wastewater Comamonas

Comamonadaceae bacteria are enriched on poly(ethylene terephthalate) (PET) microplastics in wastewaters and urban rivers, but the PET-degrading mechanisms remain unclear. Here, we investigated these mechanisms with Comamonas testosteroniKF-1, a wastewater isolate, by combining microscopy, spectroscopy, proteomics, protein modeling, and genetic engineering. Compared to minor dents on PET films, scanning electron microscopy revealed significant fragmentation of PET pellets, resulting in a 3.5-fold increase in the abundance of small nanoparticles (<100 nm) during 30-day cultivation. Infrared spectroscopy captured primarily hydrolytic cleavage in the fragmented pellet particles. Solution analysis further demonstrated double hydrolysis of a PET oligomer, bis(2-hydroxyethyl) terephthalate, to the bioavailable monomer terephthalate. Supplementation with acetate, a common wastewater co-substrate, promoted cell growth and PET fragmentation. Of the multiple hydrolases encoded in the genome, intracellular proteomics detected only one, which was found in both acetate-only and PET-only conditions. Homology modeling of this hydrolase structure illustrated substrate binding analogous to reported PET hydrolases, despite dissimilar sequences. Mutants lacking this hydrolase gene were incapable of PET oligomer hydrolysis and had a 21% decrease in PET fragmentation; re-insertion of the gene restored both functions. Thus, we have identified constitutive production of a key PET-degrading hydrolase in wastewater Comamonas, which could be exploited for plastic bioconversion.

54 ENVIRONMENTAL SCIENCES↗