Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-resolution methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Full-Strength Additive Manufacturing of Pure Aluminum Alloy 7075 Using Liquid Metal Jet Printing

Additive manufacturing (AM) of high-strength aluminum alloys can produce high-performance aerospace and biomedical parts with unique geometries and functions. However, many high-performance alloy systems such as AA 7075 pose challenges during AM due to thermal cycles that cause hot cracking, limiting AM to casting-friendly alloys. Stock AA 7075 alloy poses additional challenges due to the excessive growth of insoluble precipitates during casting and needs to be thermomechanically processed to obtain acceptable mechanical properties. Here, this work uses liquid metal jet printing to produce high-resolution pure AA 7075 parts at high strength (593 MPa) and ductility (10 pct), surpassing the specific strength of any type of steel. The parts are printed by depositing fine droplets on a high-temperature substrate that reduces cooling rates, preventing hot cracking. The results show that fully dense, crack-free parts can only be printed at substrate temperatures of 500 °C with a cooling rate threshold of < 2000 K/s to prevent cracking and < 500 K/s to eliminate porosity. The tensile strength, microhardness, and ductility of the parts matched or were beyond the wrought alloy specifications after heat treatment, possibly due to high solidification rates that produce finer insoluble precipitates. Our results indicate that many challenging high-performance alloy systems can now be 3D printed based on the critical thresholds for cooling rates using any AM method that can satisfy these conditions.

36 MATERIALS SCIENCE↗

Informed unsupervised machine learning analysis of dislocation microstructure from high-resolution differential aperture X-ray structural microscopy data

This study leverages high-resolution differential-aperture X-ray structural microscopy (DAXM) to probe the local dislocation structure in deformed 304L-stainless steel at small strain, by measuring the lattice rotation and deviatoric elastic strain with a sub-micron resolution. For a single grain in a polycrystalline specimen, the measured lattice rotation field over the measured volume exhibited a multimodal distribution while the deviatoric elastic strain showed a single-mode distribution. An unsupervised Cauchy mixture machine learning model was developed to resolve the multimodal distribution of the lattice rotation. By mapping the lattice rotation data associated with each Cauchy peak in the model back onto the measured volume, we identify contiguous regions of the crystal rotated near the average values corresponding to the peaks of the overall rotation distribution. These regions represent the grain subdivision in the microstructure. Finally, the dislocation density tensor was also computed and its norm was laid over the rotation field to detect the subgrain boundaries. This step provided a validation of the Cauchy mixture model for the analysis of the lattice rotation distribution. The current study highlights the integration of advanced X-ray microscopy techniques with data-driven analysis methods to uncover detailed microstructure scales in deformed crystals.

Machine learning; Lattice rotation; High-energy X-↗

Mapping tree height in complex terrain of northern China using ultra-high-resolution images

Tree height is a key parameter for estimating forest biomass and carbon sequestration. In recent years, notable progress has been made in mapping tree height using satellite imagery. However, existing tree height products show low accuracy in mountainous and complex terrains, and few studies typically addressed tree height estimations in mountain areas. This study examines the Mentougou district of Beijing, China, characterized by complex terrain and mountainous landscapes. We analyzed two methods for estimating tree height: one using only spectral features and another combining spectral features with topographic factors (elevation, slope, aspect). We used 3-m resolution PlanetScope 8-band multispectral imagery, with 710 field-measured individual tree heights averaged to obtain 471 pixel-level tree height values as ground-truth, to develop tree height prediction models using eXtreme Gradient Boosting (XGBoost), Random Forest (RF), and Gradient Boosting Machine (GBM) models. The results show that the XGBoost model consistently presented the highest accuracy for both methods evaluated. Specifically, the XGBoost model that combined spectral data with elevation and slope variables with an R² of 0.75 and an RMSE of 2.69 m. Using the XGBoost model, we generated the tree height map for the Mentougou area at 3 m resolution, showing tree heights ranging from 0.5 to 30.4 m, and the model’s prediction error standard deviations ranged from 2.50 to 4.71 m, indicating reliable performance across varied terrain. Additionally, we compared and evaluated the global tree height products, identifying limitations in the accuracy within complex terrains. This study demonstrates the potential for accurately predicting tree heights by combining high-resolution multispectral satellites with a terrain factor modeling approach.

Complex terrain↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Framework of compressive sensing and data compression for 4D-STEM

Four-dimensional Scanning Transmission Electron Microscopy (4D-STEM) is a powerful technique for high-resolution and high-precision materials characterization at multiple length scales, including the characterization of beam-sensitive materials. However, the field of view of 4D-STEM is relatively small, which in absence of live processing is limited by the data size required for storage. Furthermore, the rectilinear scan approach currently employed in 4D-STEM places a resolution- and signal-dependent dose limit for the study of beam sensitive materials. Improving 4D-STEM data and dose efficiency, by keeping the data size manageable while limiting the amount of electron dose, is thus critical for broader applications. Here we introduce a general method for reconstructing 4D-STEM data with subsampling in both real and reciprocal spaces at high fidelity. The approach is first tested on the subsampled datasets created from a full 4D-STEM dataset, and then demonstrated experimentally using random scan in real-space. The same reconstruction algorithm can also be used for compression of 4D-STEM datasets, leading to a large reduction (100 times or more) in data size, while retaining the fine features of 4D-STEM imaging, for crystalline samples.

4D-STEM↗

Extreme Ultraviolet and Beyond Extreme Ultraviolet Lithography Using Amorphous Zeolitic Imidazolate Resists Deposited by Atomic/Molecular Layer Deposition

Amorphous zinc-imidazolate (aZnMIm) resists show potential to meet the demands for next-generation high-numerical aperture (high-NA) metal-containing extreme ultraviolet (EUV) resist materials, given their ease of deposition by atomic/molecular layer deposition (ALD/MLD) at thicknesses of 20 nm and below. Here, this study demonstrates that aZnMIm thin films, previously identified as high-resolution electron beam resists, can also function as negative-tone EUV photoresists. Water development achieves high sensitivity (5 mJ/cm 2 ) but leaves significant residue, while acetic acid development results in poor contrast. A hybrid approach─water followed by acetic acid─enables residue-free development with a sensitivity of 181 mJ/cm 2 . Dry development using 1,1,1,5,5,5-hexafluoroacetylacetone (hfacH) is also possible but shows lower sensitivity (375 mJ/cm 2 ) compared to wet development methods. EUV photoelectron spectroscopy (PES), reflectometry/EUV absorption, total electron yield (TEY), residual gas analysis (RGA), and time-of-flight secondary ion mass spectrometry (TOF-SIMS) were used to investigate the effects of EUV irradiation on aZnMIm resists. Reflectometry experiments reveal an aZnMIm EUV absorption coefficient of 6.2 μm –1 , while PES and TEY analyses show that, compared to poly(4-hydroxystyrene) (PHS), a polymer-based reference resist, aZnMIm emits more primary and secondary electrons but generates fewer slow electrons relative to its primary electron emission; its total electron yield is similar to that of poly(methyl methacrylate) (PMMA) resists. When exposed to EUV, aZnMIm predominantly outgasses H 2 , as determined by RGA. TOF-SIMS measurements demonstrate that high-dose EUV exposure only partially fragments the 2-methylimidazole (2MIm) organic linkers, unlike high-dose electron beam exposure, which is known to completely degrade them. Additionally, aZnMIm resists show promise for potential beyond EUV lithography (BEUVL) due to the presence of Zn, which provides higher sensitivity at a wavelength of 6.7 nm compared to other metal ions, such as Sn, that are currently used in the best-performing EUV metal–organic resists. TEY measurements demonstrate that aZnMIm emits nearly twice as many electrons as PHS at 6.7 nm. The BEUV TEY of aZnMIm also surpasses that of PMMA, poly(pentafluorostyrene), and poly(4-iodostyrene), with the latter two being known for their high EUV TEYs. This work provides insight into zeolitic imidazolate framework (ZIF)-based EUV and BEUV resists and highlights their potential for both wet and dry development.

lithography↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Spin-on deposition of amorphous zeolitic imidazolate framework films for lithography applications

Amorphous zeolitic imidazolate framework (aZIF) films have been recently introduced as resists for electron beam and extreme ultraviolet lithography. aZIFs are also being considered for separation applications, including thin film membranes. However, the reported methods for aZIF deposition are currently based on highly empirical trial-and-error approaches that hinder control of film composition, thickness and uniformity as well as scale-up and transferability to different coating geometries. This work presents a method for depositing aZIF films with controllable thickness using dilute precursors mixed immediately before encountering the substrate. Importantly, the method is amenable to quantitative analysis by computational fluid dynamics to extract intrinsic deposition rates and limiting reactant transport diffusivities, enabling predictive physics-based modeling of the deposition process. This allows the deposition method to be adapted for spin coating on silicon wafers to prepare high-quality aZIF films with consistently controlled thickness. Using this approach, high-resolution resist performance and wafer-scale use for beyond extreme-ultraviolet lithography of aZIF films is demonstrated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗

Photon calibration techniques for high resolution cryogenic detectors

Monoenergetic photons from a pulsed laser diode or LED are commonly used to calibrate the detector response of high-resolution calorimetric detectors. However, when the detector’s resolution is larger than the energy of a single photon, a calibration is normally derived using Poisson statistics. In this paper, we clarify the assumptions implicit in this calibration method, before considering how a more realistic model of a detector’s performance will violate these assumptions, biasing the calibration. Lastly, we judge the individual impact of specific detector parameters on our calibration, and conclude with discussion of both the limits of our calculations and the implications for state-of-the art detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nano-laminography with a transmission X-ray microscope

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on. The efficiency of the technique is demonstrated with 50 nm spatial resolution and minute-scale temporal resolution 3D imaging of a planar integrated circuit sample and targeted imaging of an individual particle within a powder sample, where mounting procedures are typically challenging in regular nano-tomography. The sample mounting strategy, data acquisition, and reconstruction method will also be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ResSR: A Computationally Efficient Residual Approach to Super-Resolving Multispectral Images

Multispectral imaging (MSI) plays a critical role in material classification, environmental monitoring, and remote sensing. However, MSI sensors typically have wavelength-dependent resolution, which limits downstream analysis. MSI super-resolution (MSI-SR) methods address this limitation by reconstructing all bands at a common high spatial resolution. Existing methods can achieve high reconstruction quality but often rely on spatially-coupled optimization or large learning-based models, leading to significant computational cost and limiting their use in large-scale or time-critical settings. In this paper, we introduce ResSR, a computationally efficient, model-based MSI-SR method that achieves high-quality reconstruction without supervised training or spatially-coupled optimization. Notably, ResSR decouples spectral and spatial processing into two sequential steps. ResSR first computes a spectrally-informed high-resolution estimate of the MSI using singular value decomposition together with a spatially-decoupled approximate forward model. It then applies a residual correction step to restore low-frequency spatial consistency while preserving high-frequency detail recovered by the spectral reconstruction. ResSR achieves comparable or improved reconstruction quality relative to existing MSI-SR methods while being

Sullivan, Haley [ORNL] (ORCID:0000000274069217)↗

VoroClust

SAND2025-11465O VoroClust, also known as Voronoi Clustering, is a fast, density-based unsupervised clustering algorithm applicable to high-resolution and high-dimensional data. It operates as quickly as distance-based clustering methods while effectively capturing complex regional geometries, matching the performance of current density-based methods. VoroClust employs a data-centered sphere cover to reduce computational demands while preserving data topology. It propagates clusters outward from local density peaks. Although supervised machine learning is powerful for applications like image classification and segmentation, it requires comprehensive, consistent datasets, which many applications lack. Unsupervised clustering algorithms analyze the structure of each dataset rather than relying on similarities with other examples, making them well-suited for practical applications with insufficient or inappropriate data for supervised learning. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Ebeida, Mohamed [Sandia National Lab. (SNL-CA), Li↗

ORBIT-2 Dataset for Scaling Exascale Vision Foundation Models for Weather and Climate Downscaling

This dataset release corresponds to the work conducted in ORBIT-2: Scaling Exascale Vision Foundation Models for Weather and Climate Downscaling, where large-scale AI methods were applied to improve climate and weather resolution. The collection integrates four widely used, publicly available datasets: ERA5, PRISM, DAYMET, and IMERG. To prepare the data for ORBIT-2 model training and evaluation, we applied a preprocessing pipeline that generates paired low-resolution and high-resolution samples, enabling supervised downscaling experiments. The transformation from coarse to fine scales was performed using bilinear regridding, consistent with the procedures described in WeatherBench2, a community benchmark for weather and climate AI models. This dataset supports the development and evaluation of foundation models designed for weather and climate downscaling at exascale. Additional details on methodology and applications can be found in Wang et al., ORBIT-2 (arXiv:2505.04802, 2025).

54 ENVIRONMENTAL SCIENCES↗

Single-shot spatiotemporal plasma density measurements with a chirped probe pulse

In this work, we present the development and demonstration of a diagnostic for the measurement of the spatial and temporal evolution of plasma density in a single shot. Single-shot Advanced Plasma Probe HolographIc REconstruction (SAPPHIRE) utilizes a chirped probe pulse, a diffractive optical element, a self-referenced interferometer, and an interference bandpass filter to achieve high-fidelity electron density measurements suitable for underdense plasmas that exhibit cylindrical symmetry. The method overcomes limitations in conventional diagnostics, such as reliance on shot-to-shot reproducibility, while capturing plasma dynamics on picosecond timescales with micron-level spatial resolution. The capabilities of SAPPHIRE are demonstrated through measurements of laser-driven plasma channels in helium–nitrogen gas jets. SAPPHIRE demonstrates the formation and expansion of plasma channels in a single shot and the propagation of supersonic ionization fronts while revealing shot-to-shot variations in the plasma profiles. Experimental results are validated against theoretical models and scaling laws, underscoring the robustness and accuracy of this technique. By enabling ultrafast, high-resolution plasma diagnostics in a single exposure, SAPPHIRE represents a transformative advancement in plasma measurement technology.

Grace, Elizabeth S. [Lawrence Livermore National L↗

STILGAR End-of-Project Report

The Subsurface Tunnel Imaging LeveraGed by Analysis of Rayleigh wave ellipticity (STILGAR) project demonstrated an integrated geophysical approach for detecting, locating, and characterizing underground structural changes using dense seismic arrays and advanced inversion techniques. Field campaigns were conducted at two operational mines—the Redmond salt mine (Utah) and Graymont Pleasant Gap limestone mine (Pennsylvania)—providing real-world testbeds for monitoring anthropogenic subsurface activity. At the Redmond salt mine, seismic interferometry combined with back-projection inversion successfully identified continuous, low-amplitude signals from mining operations. The approach differentiated stationary from migrating anthropogenic sources, captured daily operational cycles, and validated the potential of passive seismic monitoring for remote detection of underground activity. At the Graymont Pleasant Gap mine, two dense seismic deployments in the spring and fall of 2023 generated over 4 TB of high-resolution data. Key outcomes included the relocation of 199 underground and 8 surface explosions with accuracies within tens of meters and the development of a 3D P-wave velocity model using the triple-difference tomography algorithm (tomoTD) that resolved major structural features such as the mine entrance, low-velocity tunnels, and roof-collapse areas. Ambient noise cross-correlation and back-projection analyses revealed persistent sources linked to ongoing mining activity, whereas horizontal-to-vertical spectral ratio (HVSR) and ellipticity studies confirmed stable site responses across seasons and identified soil thickness trends consistent with regional erosional and depositional processes. Checkerboard and sensitivity tests further validated the robustness of the tomographic results. Overall, the findings emphasize that although significant progress has been made in subsurface imaging, further work is needed to enhance the detection and localization of underground structures. Accurate imaging requires higher frequencies, yet anthropogenic sources tend to dominate the seismic record at those frequencies, and high-frequency surface waves are affected by higher modes that complicate interpretation. The improved detection and localization of human-induced signals enabled detailed temporal and spatial mapping of daily mine operations, demonstrating the feasibility of continuous anthropogenic source monitoring. Sensitivity to signals from nontraditional sources, such as fan operations, highlights the broader applicability of this approach to other industrial environments in which continuous and impulsive signals are present. The field campaigns produced a substantial volume of high-quality seismic data, supporting the development and testing of new methods for seismic source characterization and subsurface imaging. Future deployments should include sensors capable of recording lower frequencies to probe deeper structures, increase bandwidth to enhance resolution and sensitivity to both shallow and deep targets, and collect additional large-scale datasets to refine imaging and source characterization techniques. Moreover, conducting 3D modeling studies of seismic wavefields at higher frequencies will provide a better understanding of wave scattering and cavity–wavefield interactions in complex underground environments. In conclusion, the STILGAR project demonstrated that integrated seismic monitoring can effectively characterize underground operations, capturing both natural and anthropogenic signals. The approaches developed provide a foundation for improved detection, localization, and imaging of subsurface structures and are directly transferable to broader industrial monitoring applications.

58 GEOSCIENCES↗

Downscaled Earth System Model Data for Resilient Energy System Planning

The second-generation Sup3rCC dataset provides high-resolution meteorological data generated through the downscaling of multiple earth system models (ESMs) from the Coupled Model Intercomparison Project Phase 6 (CMIP6). This downscaling is performed through application of a generative machine learning approach called Super-Resolution for Renewable Resource Data (sup3r). This dataset builds on the first-generation Sup3rCC data by applying improved bias correction methods and adding downscaled precipitation to the output variables. In this presentation, we explore the output characteristics of the dataset and various validation analyses. We also present and discuss plans for the integration of this data into power system planning models using a decision-making under deep uncertainty (DMDU) methodology.

97 MATHEMATICS AND COMPUTING↗

An efficient hybrid downscaling framework to estimate high-resolution river hydrodynamics

Flow depth and velocity are the most important hydrodynamic variables that govern various river functions, including water resources, navigation, sediment transport, and biogeochemical cycling. Existing high-resolution flow depth simulations rely on either computationally expensive river hydrodynamic models (RHMs) or data-driven models with formidable training costs, whereas data-driven modeling of flow velocity has rarely been explored. Here, using the hybrid Low-fidelity, Spatial analysis, and Gaussian process learning (LSG) model, we developed a downscaling approach to construct high-resolution flow depth and velocity from a two-dimensional (2-D) RHM simulation at coarse resolution. The LSG models were trained and tested in an urban watershed in Houston using two different hurricane-driven flood events. The high-resolution (as fine as 30 m resolution) and low-resolution (mostly 1000 m resolution) meshes include 664 724 and 14 536 grid cells, respectively. The results showed that through downscaling, the simulation errors were reduced to less than one-fourth and one-third of the errors of the low-resolution 2-D RHM for flow depth and velocity, respectively. Our analysis further revealed that the dominant uncertainty sources of the downscaled hydrodynamics are different, with flow velocity dominated by the dimensionality reduction error, which we reduced by using a regionalized training procedure. The downscaling approach achieves an 84-fold acceleration in computational time compared to the high-resolution 2-D RHM, making high-fidelity ensemble flood modeling feasible. More importantly, the developed method provides an opportunity to couple large-scale hydrodynamical processes with local physical, chemical, and biological processes in river models.

Tan, Zeli [Pacific Northwest National Laboratory (↗