Search NASA⌕ Search

SEARCH · Search NASA

Results for “historic data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Multiscale and Multivariate Transportation System Visualization for Shopping District Traffic and Regional Traffic

In this paper, we present a suite of visualization techniques for sensor-based transportation system data at different scales to facilitate the exploration of interconnected traffic dynamics at intersections and highways. Additionally, these techniques are designed for analyzing multivariate traffic data from radar-based highway sensors and camera-based intersection sensors recording turn movements and vehicle speed, in the Chattanooga Metropolitan Area, with the capability of (a) revealing multiscale mobility patterns using different levels of data aggregation (e.g., individual sensor for microscale, multiple sensors along a corridor for mesoscale, and a larger number of sensors across the region for macroscale visualization) at different intervals (e.g., 5-min intervals, time of day, full day, and day-of-the-week), and (b) exploring the spatial variation of multiple traffic-related variables (e.g., volumes, speeds, turn movements, and traffic light colors) provided by the sensors. We close with a case study to demonstrate the effectiveness of our multiscale and multivariate visualization techniques. At microscale, we focused on intersection data from a shopping district around Shallowford Road in East Chattanooga. For mesoscale visualization, we studied the Shallowford Road corridor and an adjacent stretch of I-75. At macroscale, we included highway data from the Chattanooga Metropolitan Area. All visualizations were integrated into a web-based situational awareness tool to promote user access and interaction. At a minimum, each visualization provides the option for selecting dates for real-time (depending on sensor availability) and historical data, and additional information on hovering, though most provide more detailed information, including different views of the selected data, or interactive highlights.

33 ADVANCED PROPULSION SYSTEMS↗

Cataloging Legacy Data from the Tritium Systems Test Assembly Program

The Tritium Systems Test Assembly (TSTA) at Los Alamos National Laboratory, operational from 1984 to 2001, was critical in advancing fusion fuel cycle technologies, including tritium storage, gas separation, and pumping. TSTA’s contributions, particularly in safe tritium operations, have influenced subsequent fusion projects. This paper discusses the ongoing effort to digitize and catalog TSTA’s historical data to create a searchable resource for the fusion research community. While the long-term objective is to develop a relational database for structured data management, the project remains in the early phase, with current efforts focused on scanning and indexing physical documents. Initial plans for database implementations are also presented, outlining key considerations for structure, query indexing, and standardization. As digitization progresses, future discussions will refine these implantation details to ensure an efficient and comprehensive system. This initiative aims to preserve critical legacy data, enhance the design of tritium system facilities, and support the next generation of fusion energy research.

42 ENGINEERING↗

UNCERTAINTY-AWARE DEEP LEARNING FRAMEWORK FOR FORECASTING COASTAL WATER LEVEL IN VIRGINIA BEACH

Coastal areas like Virginia Beach, USA, are increasingly vulnerable to flooding. To mitigate the impact of flooding, it is crucial for the City of Virginia Beach to have reliable 72-hour-ahead (3 days) forecasts of water levels at key gauge locations. To support this effort, several sensors have been installed throughout the city to monitor water levels and other environmental parameters such as wind speed, precipitation, and atmospheric pressure. Leveraging sensor data from one of these locations, we developed an uncertainty-aware deep learning model to forecast water levels. We employed deep quantile regression (DQR) to quantify variability in the predictions and examined the performance of three different model architectures. In addition to exclusively including historical data, we investigated the improvement wind forecasts provide to the accuracy of 72-hour-ahead water level predictions. The results show a twelvefold improvement in the flood forecast for a real flooding event.

Hasan, Mahmud [Thomas Jefferson National Accelerat↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

FLASC (FLORIS-based Analysis for SCADA data)

FLASC provides a rich suite of analysis tools for SCADA data filtering & analysis, wind farm model validation, field experiment design, and field experiment monitoring. The repository is centrally built around NRELs in-house floris wind farm model, available at https://github.com/nrel/floris. FLASC also largely relies on the energy ratio to, among others, quantify wake losses in synthetic and historical data, to perform turbine northing calibrations, and for model parameter estimation.

Fleming, Paul↗

HPC Analytics of Fused Thermal Plants Data to Optimize Operating Envelope

In this project, ORNL extensively reviewed the ORAP RAM data, and it guided us to develop machine learning models that can predict time to next failures and forecast failure trends, which will be useful for optimizing power plant operation strategies. More specifically, we trained multiple random forest models and evaluated the model accuracy to validate with 10+ years of historical data. In addition, we implemented a web-based graphical user interface system for the models to show how our models can be used in more intuitive ways. This proof of concept allowed exploration of model use with power plant operators in mind. Developed machine learning models will be helpful for managing risks, planning maintenance and operation, ultimately reducing the down time and increasing the service hours. For future work, there are several interesting research topics including but not limited to model enhancement, creating synergy with traditional failure modeling approaches, and data-driven actionable recommendation and suggestions.

20 FOSSIL-FUELED POWER PLANTS↗

Optimal PV Inverter Control in Distribution Systems via Data-Driven Distributionally Robust Optimization

Distribution systems with high penetration of uncertain solar generation call for advanced control strategies of photovoltaics (PVs) inverters. This paper proposes a data-driven distributionally robust optimization (DDDRO) approach to optimally controlling the PV inverters to improve the system operation performance under solar power uncertainties. In the proposed DDDRO approach, a Wasserstein ball-based method is proposed to construct the distributional ambiguity set to model the uncertainties of PV generation through partial observations of historical data without knowing exact probability distributions. We further reformulate the computationally intractable DDDRO model to a mixed integer second order cone programming (MISOCP) problem. The effectiveness and out-of-sample performance of the proposed approach have been demonstrated on a modified IEEE 33-node system. We conduct a comparative study to compare the proposed method with traditional chance constrained programming (CCP). It shows that the proposed DDDRO approach can provide a less conservative yet robust solution to minimize the worse-case expectation of the total network loss while maintaining nodal voltages in a secure range.

Xue, Yaosuo↗

Archi: Agentic Operations at the CMS Experiment

We present Archi, an open-source, end-to-end framework for scientific collaborations that combines the systematic ingestion and organization of heterogeneous data sources with the deployment of configurable, private, and extensible agents that retrieve and reason over them. An instance of Archi has been deployed for the Computing Operations team of the CMS experiment at CERN's LHC since February 2026 as a support agent for technical operators, offering retrieval and analysis capabilities by combining documentation, historical data, and live monitoring systems. We evaluate the system on operator feedback and a question set collected from production usage, graded by human and automated panels. The system proves effective at operational tasks, resolving real-world queries posed by CMS operators. We also observe that locally-hosted, open-weight models perform competitively, enabling fully private management of sensitive data.

Lugato, Pietro [MIT; CERN]↗

Harmonization of global land use change and management for the period 850–2100 (LUH2) for CMIP6

Abstract. Human land use activities have resulted in large changes to the biogeochemical and biophysical properties of the Earth's surface, with consequences for climate and other ecosystem services. In the future, land use activities are likely to expand and/or intensify further to meet growing demands for food, fiber, and energy. As part of the World Climate Research Program Coupled Model Intercomparison Project (CMIP6), the international community has developed the next generation of advanced Earth system models (ESMs) to estimate the combined effects of human activities (e.g., land use and fossil fuel emissions) on the carbon–climate system. A new set of historical data based on the History of the Global Environment database (HYDE), and multiple alternative scenarios of the future (2015–2100) from Integrated Assessment Model (IAM) teams, is required as input for these models. With most ESM simulations for CMIP6 now completed, it is important to document the land use patterns used by those simulations. Here we present results from the Land-Use Harmonization 2 (LUH2) project, which smoothly connects updated historical reconstructions of land use with eight new future projections in the format required for ESMs. The harmonization strategy estimates the fractional land use patterns, underlying land use transitions, key agricultural management information, and resulting secondary lands annually, while minimizing the differences between the end of the historical reconstruction and IAM initial conditions and preserving changes depicted by the IAMs in the future. The new approach builds on a similar effort from CMIP5 and is now provided at higher resolution (0.25∘×0.25∘) over a longer time domain (850–2100, with extensions to 2300) with more detail (including multiple crop and pasture types and associated management practices) using more input datasets (including Landsat remote sensing data) and updated algorithms (wood harvest and shifting cultivation); it is assessed via a new diagnostic package. The new LUH2 products contain > 50 times the information content of the datasets used in CMIP5 and are designed to enable new and improved estimates of the combined effects of land use on the global carbon–climate system.

54 ENVIRONMENTAL SCIENCES↗

A Nonstationary and Non-Gaussian Moving Average Model for Solar Irradiance

Historically, power has flowed from large power plants to customers. Increasing penetration of distributed energy resources such as solar power from rooftop photovoltaic has made the distribution network a two-way-street with power being generated at the customer level. The incorporation of renewables introduces additional uncertainty and variability into the power grid. Distribution network operation studies are being adapted to include renewables; however, such studies require high quality solar irradiance data that adequately reflect realistic meteorological variability. Data from satellite-based products are spatially complete, but temporally coarse, whereas solar irradiances exhibit high frequency variation at very fine timescales. We propose a new stochastic method for temporally downscaling global horizontal irradiance (GHI) to 1 min resolution, but we do not consider the spatial aspect due to limited availability of the in situ irradiance measurements. Solar irradiance's first and second-order structures vary diurnally and seasonally, and our model adapts to such nonstationarity. Empirical irradiance data exhibits highly non-Gaussian behavior; we develop a nonstationary and non-Gaussian moving average model that is shown to capture realistic solar variability at multiple timescales. We also propose a new estimation scheme based on Cholesky factors of empirical autocovariance matrices, bypassing difficult and inaccessible likelihood-based approaches. The model is demonstrated for a case study of three locations that are located in diverse climates through the United States. The model is compared against competitors from the literature and is shown to provide better uncertainty and variability quantification on testing data.

Cholesky factor↗

Investigation of Multiple Data Streams for Gearbox Bearing Fault Prediction Through Machine-Learning Models

Operations and maintenance (O&M) cost of wind plant accounts up to 30% of total energy cost, which can be reduced through continuous monitoring and successfully detecting incipient wind turbine failures. To accomplish this, condition monitoring and predictive maintenance systems are being implemented in wind industry to support O&M decision making. A wide range of approaches for condition monitoring and fault prediction have been developed. These approaches generally use historical data of wind turbines collected by Supervisory Control and Data Acquisition (SCADA) system to identify patterns that lead to failure. These SCADA data show the overall condition of a wind turbine and can be leveraged to detect when the turbine's performance is degrading and to identify if a fault is developing. However, it becomes challenging to predict the failure of a specific wind turbine gearbox bearing, because the SCADA data are often not directly linked to the component. To bridge the gap, we have investigated features calculated from SCADA data using physics-based models and the gearbox design over the years. The damaged metric we used in the physics domain is frictional energy. Combining these physics domain variables with SCADA data as inputs to various machine learning models for gearbox bearing fault prediction, we have demonstrated the benefits of leveraging both physics and data domain models. It was an attempt to improve frictional-energy-based damage metric by adding data domain inputs, as we had learned that the frictional-energy-based damage metric alone is not sufficient to single out failed bearings from healthy. As condition monitoring data (either vibration or oil debris data) has become available at more and more wind plants, we would like to evaluate whether by adding the condition monitoring data can help further improve the performance of frictional-energy-based damage metric for gearbox bearing fault prediction. Both cases by modeling through various machine learning algorithms are discussed in this study along with some observations.

fault prediction↗

Data-Driven Voltage Regulation of Distribution Grid Using Nonlinear Autoregressive Model with Exogenous Inputs (NARX)

This article proposes data-driven control via a nonlinear autoregressive model with exogenous inputs (NARX) for real-time voltage regulation of a modified feeder using reactive power sources. Traditional voltage control strategies rely on rule-based heuristics or optimization techniques, which often require detailed system models and extensive computational resources. The NARX-based controller learns system dynamics from historical data and predicts optimal reactive power dispatch in real-time for voltage correction. The proposed approach is evaluated on a power system feeder model under varying load and network conditions. Simulation results demonstrate that the NARX-based controller achieves improved voltage regulation, offering higher adaptability to system fluctuations. This study highlights the potential of data-driven control for enhancing the reliability of power distribution networks.

Donge, Vrushabh [ORNL] (ORCID:0000000306062803)↗

A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.

14 SOLAR ENERGY↗

AmeriFlux FLUXNET-1F US-xCP NEON Central Plains Experimental Range (CPER)

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-xCP NEON Central Plains Experimental Range (CPER). This is the FLUXNET version of the carbon flux data for the site US-xCP NEON Central Plains Experimental Range (CPER) produced by applying the standard ONEFlux (1F) software. Site Description - Central Plains Experimental Range (CPER) site in north central Colorado. CPER served as part of the Shortgrass Steppe LTER from 1982-2014 and is now home to a fully instrumented NEON site and a wealth of relevant historical data as well as ongoing collections of complementary data(i.e. airborne remote sensing, soil temperature and moisture, phenology measurements, plant biomass and more)

Network), NEON (National Ecological Observatory↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

A novel implicit hybrid machine learning model and its application for reinforcement learning

A novel methodology to develop implicit hybrid models is presented. PyTorch is used to integrate physics-based equations with machine learning models. Automatic differentiation of the hybrid model is leveraged to solve the implicit equations. Iterative solving enables gradient based updates to the machine learning model. The novel methodology is compared to an explicit hybrid approach on a continuously stirred tank reactor (CSTR). The novel method results in a lower modelling error. Both hybrid models effectively train with noisy data. To test the implicit hybrid model, it is employed as a reinforcement learning (RL) training model. The RL algorithm trained on the hybrid model outperforms real time optimization of the CSTR and performs nearly as well as RL trained directly on the CSTR and a traditional gradient based approach. Training RL directly on the CSTR requires over 60,000 system interactions compared to 6000 historical data points for hybrid model development.

42 ENGINEERING↗

Robust Data-Driven Predictive Run-to-Run Control for Automated Serial Sectioning

This letter presents a one-step predictive run-to-run controller (R2R-MPC) for the automation of mechanical serial sectioning (MSS), a destructive material analysis process. To address the inherent uncertainty and disturbances in the MSS process, a robust closed-loop approach is presented. Here, the robust R2R-MPC models the uncertainty of the MSS process using a linear differential inclusion. As an analytical model of the MSS process is unavailable, the differential inclusion is identified from historical data. The R2R-MPC is posed as an optimization problem that computes incremental changes to the control input which minimize the worst-case material removal errors. This optimization-based controller is combined with a run-to-run controller to provide integral action that rejects constant disturbances and tracks constant reference removal rates. To demonstrate the efficacy of our robust R2R-MPC, we present simulation results which compare the presented controller with a conventional non-robust R2R.

42 ENGINEERING↗

AmeriFlux US-TEF Tenderfoot Creek Experimental Forest

This is the AmeriFlux version of the carbon flux data for the site US-TEF Tenderfoot Creek Experimental Forest. Site Description - This site was established by Montana State University researchers in 2005 and re-instrumented in 2025 for above- and below-canopy eddy covariance. The tower is located in the Stringer Creek sub-watershed, which is maintained as an undisturbed lodgepole pine forest, and represents one of seven gaged sub-watersheds nested within the Tenderfoot Creek Experimental Forest. Historical data collection spanned the 2005-2012 (tall tower) and 2010-2012 (sub-canopy) time periods.

Stoy, Paul↗