At least 127 records · Page 7

Fleet-wide Electrification Impacts Assessment for the Valley Transportation Authority

This report explores the long-term electrification opportunities for the Valley Transit Authority’s (VTA) transit bus fleet. The potential for transit bus electrification at VTA as well as the economic impacts of partial and complete electrification are explored. We use the Revenue Operation and Device Optimization model to determine the optimal charging, operation and lowest capital and operating cost solution to achieve different levels of electrification to meet their existing routes. This study finds that, relying on only depot charging, around 70% of the daily trips by VTA’s transit bus fleet can be replaced with battery electric buses (BEBs) today. The benefits and drawbacks of five methods for improving the electrification potential beyond that achievable with only depot charging are discussed including (1) increase charger power, (2) purchase of larger vehicle batteries, (3) en-route charging, (4) purchasing additional buses and swapping them to enable the existing routes/blocks1 to be met, and (5) route/block redesign. A strategy is developed to enable full fleet electrification by increasing charger power or allowing intraday charging as a proxy for the options mentioned above. This method allows us to develop an understanding of the impacts and trade-offs of full fleet electrification. Two charging strategies are examined. Immediate charging, when the bus is charged as soon as it arrives at a depot or en-route charging station, and smart charging, which uses a controller to determine the best times to charge to achieve the lowest charging cost, while maintaining the same trip schedules. Smart charging is effective at reducing the peak power consumption, which can be reduced by between 31% and 65% compared to immediate charging. This translates directly to lower electricity demand charges and lower costs for possible distribution system upgrades. The total lifetime net present value (NPV) costs for different scenarios are presented in Figure ES-1. Scenarios are separated into three sections. The first stacked bar on the left is the base case (business-as-usual) where all buses are diesel hybrids, the next four bars include partial and full fleet electrification utilizing only immediate charging, and the last four bars include partial and full fleet electrification utilizing smart charging. The results show that smart charging scenarios are within ±4% of the lifetime NPV cost of the diesel-hybrid only (business-as-usual) scenario. The scenarios with full fleet electrification (i.e., including intraday charging) are 4% lower cost and those with partial fleet electrification (i.e., without intraday charging) are 2%–3% higher. However, it is important to note that the intraday charging scenarios do not include any additional costs for the equipment necessary to achieve intraday charging (e.g., additional chargers, larger batteries, new route design). Additionally, it is worth noting that the Low Carbon Fuel Standard (LCFS) credit received for implementing electric buses is essential to achieving these results.

33 ADVANCED PROPULSION SYSTEMS↗

Relativistic Hybrid Stars with Sequential First-order Phase Transitions in Light of Multimessenger Constraints

In this work, we consider the properties of compact stars in which quark matter has low- and high-density phases that are separated by a first-order phase transition. Thus, unlike the commonly considered case of a single phase transition from hadronic to quark matter, our models of hybrid stars contain sequential phase transitions from hadronic matter to low- and then to high-density quark matter phases. We extend our previous study of the parameter space of hybrid stars with a single phase transition to those with sequential phase transitions, taking into account the constraints on the mass and radius of neutron stars from the NICER experiment, the experimental inferences of the neutron skin thickness of the lead nucleus by the PREX-II experiment, and constraints on the tidal deformability from the gravitational-wave event GW170817. We determine the range of the masses for which both twin and triplet configurations, i.e., identical-mass stars with two and three different values of radii, arise.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chaotic and integrable magnetic fields in one-dimensional hybrid Vlasov–Maxwell equilibria

The construction of kinetic equilibrium states is important for studying stability and wave propagation in collisionless plasmas. Thus, many studies over the past decades have been focused on calculating Vlasov–Maxwell equilibria using analytical and numerical methods. However, the problem of kinetic equilibrium of hybrid models is less studied, and self-consistent treatments often adopt restrictive assumptions ruling out cases with irregular and chaotic behaviour, although such behaviour is observed in spacecraft observations of space plasmas. In this paper, we develop a one-dimensional (1-D), quasineutral, hybrid Vlasov–Maxwell equilibrium model with kinetic ions and massless fluid electrons and derive associated solutions. The model allows for an electrostatic potential that is expressed in terms of the vector potential components through the quasineutrality condition. The equilibrium states are calculated upon solving an inhomogeneous Beltrami equation that determines the magnetic field, where the inhomogeneous term is the current density of the kinetic ions and the homogeneous term represents the electron current density. We show that the corresponding 1-D system is Hamiltonian, with position playing the role of time, and its trajectories have a regular, periodic behaviour for ion distribution functions that are symmetric in the two conserved particle canonical momenta. For asymmetric distribution functions, the system is nonintegrable, resulting in irregular and chaotic behaviour of the fields. The electron current density can modify the magnetic field phase space structure, inducing orbit trapping and the organization of orbits into large islands of stability. Thus, the electron contribution can be responsible for the emergence of localized electric field structures that induce ion trapping. We also provide a paradigm for the analytical construction of hybrid equilibria using a rotating two-dimensional harmonic oscillator Hamiltonian, enabling the calculation of analytic magnetic fields and the construction of the corresponding distribution functions in terms of Hermite polynomials.

Kaltsas, Dimitrios A. (ORCID:0000000300769015)↗

Optimal hybrid power plants for electric vehicle charging demand

Transmission constraints, increasing motivations to decarbonize, and concerns over peak electric vehicle (EV) load impacts on local grids have driven electric customers to consider behind-the-meter, hybrid power plant generation and storage at the distributed-grid level for EV charging. In this study, we develop capabilities to optimize hybrid power plant component capacities for EV charging. We then demonstrate these capabilities in a case study for Boulder, Colorado, using public EV charging data as well as wind and solar resource data. Our results show system designs that balance the cost of energy with load-meeting and peak shaving performance. Within the case study, systems designed for wind, solar photovoltaic (PV), and storage resulted in lower cost of energy than those optimized for PV and storage only. This indicates that in areas where wind resource exists, hybrid power plants that include wind, PV, and battery assets can better meet EV charging loads (including peak loads that are prone to overloading local grids) than PV and battery assets alone. Future work to address limitations in this paper include extending cost modeling to include performance losses (e.g., based on operations or weather) and charging station costs to estimate levelized cost of charging, and quantifying uncertainty and error in our aggregation methods for estimating EV charging loads at the hourly timescale.

14 SOLAR ENERGY↗

Fidelity Analysis of Complex Large-Scale Simulation Models of PEs (MARS) in Future Power Grids

With the proliferation of power electronic (PE)-based resources in the electric grid, there have been numerous different kinds of simulation models developed and studied to understand their dynamic behavior. Study of PE-based resources using each simulation model has its own distinct advantages and disadvantages. Therefore it is very important to carefully select the appropriate model for the evaluation of the PE-based resources. In this paper, one such effort is made to analyze the different types of models in the case of a multi-port autonomous reconfigurable solar power plant (MARS). The MARS integrates a hybrid photovoltaic (PV)-energy storage system (ESS) plant to high-voltage direct current (HVdc) system and transmission alternating current (ac) grid. The dynamic models are evaluated under different test cases varying the short-circuit ratio (SCR) and control algorithms. Recommendations are provided on the equipment study needs based on the analysis completed.

Marthi, Phani Ratna Vanamali↗

Resilient and Cost-Effective Hybrid Li-Ion Battery Energy Storage System for Sites with Solar Generation and Electric Vehicle (EV) Charging (CRADA Final Report, CRD-19-00799)

The batteries of an energy storage system designed for multiple use-cases are traditionally selected to withstand the highest rate at which a battery is discharged relative to its maximum capacity (C-rate) and cycling requirements of the most intense use-case. However, this is not cost-effective given that the price of the batteries is strongly correlated to C-rate and cyclability. We propose to establish design guidelines for a hybrid energy storage system and test an edge controller that uses high-power and high-energy batteries for high- cyclability use cases such as frequency regulation and electric vehicle (EV) charging and low-cost batteries for low-power and low-cyclability use cases such as summer peak loads. The three main objectives of this proposal are (i) establishing sizing guidelines for such a hybrid storage system, (ii) installing a hybrid storage system in the Energy Systems Integration Facility (ESIF) sized based on those guidelines, and (iii) testing an edge controller specific for the system through hardware tests.

14 SOLAR ENERGY↗

Superconductinglike response in a driven gapped bosonic system

In this study, we propose a mechanism for the photoinduced superconductinglike response recently reported in cuprates and other strongly correlated materials. This mechanism relies on quantum-fluctuating bosons consisting of electron pairs. With periodic drive, the electron pairs and vacancies of pairs form a coherent nonequilibrium condensate, different from conventional superconductors, yet showing a superconductinglike response in some regime even with dissipation. Unlike the case of driven fermionic bands, which results in the familiar Floquet bands with hybridization gaps, for driven bosons the “gap” opens up in the momentum direction, resulting in a resonant region in momentum space where the eigenvalues are complex. We give a simple physical argument for why this picture leads to a “perfect conductor” which exhibits superconductinglike frequency-dependent conductivity but no Meissner response. While our model is quite general, in the case of cuprates, a quantum-fluctuating pair density wave in the pseudogap region may serve as the origin of the quantum-fluctuating electron pairs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using energy storage systems to extend the life of hydropower plants

Despite their advantages, distributed energy resources (DERs) bring inherent uncertainty and variability into the landscape of modern power systems. As DER penetration grows, conventional generators like hydropower plants have to respond more often to arrest the imbalance in the net load. Hydropower turbines provide their best operational performance with minimal wear and tear when operating at regions of maximum efficiency. However, the current needs for hydropower plants require them to operate under varying load conditions and thus sub-optimal operating points leading to additional stress. To relieve the hydropower plants, this paper proposes a hybridization strategy where a hydropower unit is paired with an energy storage system (ESS) to increase operational flexibility and mitigate damage to the hydro plant. Models are developed to represent the operation of the hybrid system, quantify degradation, and assess economic benefits. Moreover, an innovative controller disaggregates the market dispatch signal into separate control setpoints for the ESS and hydropower unit. In case studies performed on a real-world hydropower facility, it was found that the ESS-based hybridization can extend the life of the hydropower plant by 5% on average. Notably, the economic benefits from reduced maintenance and deferred investment are estimated to be around $3.6 million.

13 HYDRO ENERGY↗

Review of data-driven models for quantifying load shed by non-residential buildings in the United States

Shifting and shedding power demand in buildings can be cost-effective techniques for grids to function reliably and for end users to earn compensation. Grid operators reimburse customers in proportion to the quantity of load shed. Simple data-driven methods are used to quantify this shed, which is the difference between a measured load during the event and modeled "baseline" that would have occurred in absence of the event. These methods have evolved over the years and in many cases have been integrated with building physics, to make them a hybrid between physics based and empirical models. However, there is no comprehensive analysis that provides guidance to building operators, grid operators and researchers in selecting appropriate models based on their specific needs and available data. Here, this work aims to fill this gap by critically assessing the performance of baseline models put forward from the year 2000 through 2023. The literature reviewed includes reports generated by grid operators, reports from national laboratories and academic journal articles. The work outlines modeling features like the inputs, training period, estimation method, adjustments to fine tune the predictions and metrics to evaluate the performance. A comprehensive list of 50 models has been provided. For each model, the study explores the applicability of the model to weather sensitive buildings, variability in the building profile, timing of the event, and whether the building reduces energy consumption before an event. The work identifies the situations in which a particular model works and draws lessons based on evidence of performance. Finally, recommendations to aid in model selection are given.

97 MATHEMATICS AND COMPUTING↗

Mitigation of emissions and energy consumption due to light-duty vehicle size increases

Analysts need to consider the shift of light-duty vehicle sales from cars to light trucks to accurately project fuel consumption, greenhouse gas emissions, and consumer spending. Here, we find that energy consumed by on-road light-duty vehicles in the United States can vary by 10% by changing assumptions regarding the sales mix. Scenarios aligned with third-party forecasts, assuming a greater sales proportion of light trucks and fewer cars, yield petroleum consumption 3–8% higher than forecasts from the U.S. Energy Information Administration (EIA), with greenhouse gas emissions 5–7% higher and a 4–9% increase in consumer spending on vehicles and fuel. This incremental energy consumption can be offset by additional technologies for these vehicles. If most sedans were phased out in favor of larger sport utility vehicles, we find a sales share of 30% battery electric vehicles or 39% hybrid electric vehicles would equal the emissions of the EIA Reference Case.

33 ADVANCED PROPULSION SYSTEMS↗

On the prediction of critical heat flux using a physics-informed machine learning-aided framework

The critical heat flux (CHF) corresponding to the departure from nucleate boiling (DNB) crisis is essential to the design and safety of a two-phase flow boiling system. Despite the abundance of predictive tools available to the thermal engineering community, the path for an accurate, robust CHF model remains elusive due to lack of consensus on the DNB triggering mechanism. This work aims to apply a physics-informed machine learning (ML)-aided hybrid framework to achieve superior predictive capabilities. Such a hybrid approach takes advantage of existing understanding in the field of interest (i.e., domain knowledge) and uses ML to capture undiscovered information from the mismatch between the actual and domain knowledge-predicted target. A detailed case study is carried out with an extensive DNB-specific CHF database to demonstrate (1) the improved performance of the hybrid approach as compared to traditional domain knowledge-based models, and (2) the hybrid model’s superior generalization capabilities over standalone ML methods across a wide range of flow conditions. The hybrid framework could also readily extend its applicability domain and complexity on the fly, showing an elevated level of flexibility and robustness. Based on the case study conclusions, the window-type extrapolation mapping methodology is further proposed to better inform high-cost experimental work.

42 ENGINEERING↗

LCA-based environmental sustainability assessment of hybrid additive manufacturing of a turbine blade

In this paper, a cradle-to-gate life cycle assessment (LCA) method is used to compare the overall energy consumption and environmental impact of hybrid additive manufacturing (HAM) and the traditional CNC milling process with a case study of turbine blade manufacturing. Six environmental impacts are assessed in this study: acidification potential (AP), eutrophication potential (EP), global warming potential (GWP), photochemical ozone creation potential (POCP), ozone depletion potential (ODP), and abiotic depletion potential (ADP). The results suggest that HAM can not only reduce energy consumption and material waste but also reduce the environmental impact by 53% from a life cycle perspective. Specifically, the results of GWP, AP, EP, ODP, POCP and ADP of the HAM are only 32.2%, 34.6 %, 44.7%, 27.2%, 25.6%, and 24.7 % of that in traditional CNC machining.

54 ENVIRONMENTAL SCIENCES↗

Electrification of residential and commercial buildings integrated with hybrid renewable energy systems: A techno-economic analysis

Here, this study assesses the techno-economic viability of city-scale building electrification, comparing a base case scenario with conventional HVAC systems to an electrified scenario with heat pump systems. EnergyPlus simulations reveal a 28% increase in annual electricity consumption in the electrified scenario, shifting the peak consumption from summer to winter with a 49% surge. Hybrid renewable energy systems (HRESs) are then evaluated using HOMER Pro, considering renewable penetration from 0% to 100%. The net present cost (NPC) of the base case and electrified scenarios range from $\$10.34$ to $\$24.38$ billion and $\$8.79$ to $\$50.31$ billion, respectively. Sensitivity analysis explores the impact of carbon tax, fuel price, and renewable subsidies on HRESs in the electrified scenario. Results indicate that applying a carbon tax up to $\$120$/tonne of CO 2 increases the optimum renewable fraction from 5% to 26%, while higher fuel prices and renewable subsidies further enhance the feasibility by shifting the optimum renewable fraction to 60% and 54%, respectively, demonstrating the interplay between economic factors and renewable integration in electrified urban contexts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Black-Box Optimization for Design of Concentrating Solar Power and Photovoltaic Hybrid Systems with Optimal Dispatch Decisions

The hybridization of concentrating solar power (CSP) and photovoltaics (PV) can enable dispatchable renewable electricity generation at a lower price than current stand-alone CSP systems. However, designing a CSP-PV hybrid system can be challenging because of the many degrees of freedom in design that affect the internal and external system interactions and trade-offs. We develop a methodology to determine optimal designs for CSP-PV hybrids by implementing NLopt's derivative-free, or “black-box,” algorithms around pre-existing CSP-PV hybrid simulation software that utilizes the National Renewable Energy Laboratory’s System Advisor Model (SAM); we then employ a dispatch optimization model to determine operational decisions that maximize a plant’s profits. We present optimal designs for CSP-PV hybrid systems dispatching against four time-of-delivery (ToD) pricing structures. NLopt’s algorithms can improve the base case design’s power purchase agreement (PPA) price by 15% to 21%, depending on the ToD pricing structure. In addition, we present the resulting optimal CSP-PV hybrid design’s annual performance metrics, which tend to have capacity factors between 50% and 62%, but are able to generate electricity during the year’s highest-valued periods about 90% of the time. Lastly, we investigate the trade-offs between capacity factor and PPA price using Pareto fronts and demonstrate that, for some ToD pricing structures, the system capacity factor can increase by 20% but at the expense of a 2% increase in PPA price.

black-box↗

Cyber Security Analysis for Nuclear Reactor Control Systems (Final Technical Report)

This project investigated the cyber-security impacts of moving from an all analog, point-to-point, instrumentation and control (I&C) system to a digital I&C system based on Modbus and a shared communication medium. A formalism called a hybrid attack graph was expanded to support the nuclear research reactor system. The hybrid attack graph allows one to check a system for vulnerabilities, in this case cyber-security vulnerabilities, and to document the attack vectors (scenarios) causing those vulnerabilities. In parallel, a simulation of the system was developed to model both the physical reactor parameters and operations, as well as the network interconnects and communications. This simulation platform was modeled on the nuclear research reactor located at Washington State University. The simulation platform provided a sandbox to evaluate and quantify the impact of identified and proposed vulnerabilities in the system and to determine the effectiveness of countermeasures at stopping these attacks. The simulation and hybrid attack graph tools were integrated to provide a streamlined process of generating attack scenarios, playing those scenarios out in the simulation, and then analyzing the results to correlate system state to states in the hybrid attack graph. This process was used to (1) quantify the impact of attack scenarios and (2) to determine if the system moved through the hybrid attack graph as anticipated. The hybrid attack graph tool was extended and customized to produce a tool to automatically identify critical assets (CAs) and critical digital assets (CDAs) as defined by NRC Regulatory Guide 5.71. This tool was verified using the nuclear research reactor at Washington State University. Finally, a series of educational modules covering the findings of the different aspects of this research have been created.

97 MATHEMATICS AND COMPUTING↗

Process-level cost analysis of hybrid manufacturing pathways for aerospace structural components

Hybrid manufacturing is a promising route for producing complex aerospace components, yet systematic cost benchmarking across multiple additive-subtractive pathways remains limited. This study presents a comprehensive process-based cost analysis of seven hybrid manufacturing routes, including laser powder bed fusion (L-PBF), powder- and wire-directed energy deposition (DED), wire arc additive manufacturing (WAAM), additive friction stir deposition (AFSD), metal binder jetting (MBJ), and agility forging, followed by scanning and finish machining. Parametric cost models incorporating direct material, labor, and energy costs were developed. L-PBF results are discussed in detail for a pickle fork component and directly compared with commercial pricing. Across all hybrid routes, labor emerged as the dominant cost driver, contributing more than 70% of total manufacturing cost in some cases. AFSD exhibited the lowest cost for aluminum components, with MBJ being its 316 L stainless steel counterpart, after accounting for geometric scaling. Benchmarking against industrial quotes suggests that hybrid manufacturing can achieve cost levels comparable to those of commercial services, although labor-intensive processes exhibit greater deviation. The analysis highlights automation of material handling, setup, and supervision as key opportunities for improving economic competitiveness. Overall, the proposed framework provides a quantitative basis for evaluating and optimizing hybrid manufacturing pathways for aerospace applications.

Baruah, Sweta [ORNL] (ORCID:0009000174256207)↗

Development of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an Integrated Energy System (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. A new RAVEN (Risk Analysis Virtual ENvironment) plugin for grid and capacity optimization (HERON) has been developed for optimizing the production variables of the IES given the demand profile. Currently, only the limits that affect the production variables and their corresponding time rates of change are considered (explicit constraints). However, other variables are additionally subject to constraints, but the associated limits are not accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response effects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. The Reference Governor (RG) algorithm is traditionally used for enforcing state and control constraints by modifying the set-point trajectories supplied to the feedback regulators. In our application, the RG is coupled within an iterative loop with the HERON-power dispatcher to generate optimal trajectories that ensure the operational constraints are met. A data-driven procedure to derive a representation of the dynamics of the controlled system was developed. First, the variables that represented the state of the system are selected (PCA-based approach), and then state-space representation matrices are derived from the collected measurements (DMDc algorithm). A preliminary version of the developed workflow based on Linear Time Invariant matrices was assessed by adopting a two-unit test case. More sophisticated versions of this workflow foreseeing the on-line derivation of system matrices will be deployed in FY 2021. Finally, a “plug-and-play” library of controllers and state observers was developed in Dymola. Some aspects of the current configuration of the IES unit components, e.g., the encapsulation of the control schemes into dedicated blocks, are consistent with the “plug-and-play” philosophy. Other features, e.g., the system buses collecting the input and the output variables, are not. For this reason, once listed and described the limits of the current configuration, necessary modifications to the plant model interface are presented. As a test-case, the interfaces of the SES model in the RAVEN-based HYBRID framework were reworked accordingly, and two different control schemes were applied to the same plant model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Modelling of HTGR Thermal Load Follow in Modelica

The ability of nuclear power plants to load follow electrical power demand is particularly important as we move to higher variable renewable (VRE) energy production on low carbon energy grids. High temperature gas reactors (HTGRs) are capable of load following by adjusting thermal output, but their high temperatures and thermal inertia significantly impact the power transients they are able to follow. To aid investigation into new integrated energy systems with advanced reactors, it is necessary to have an open-source transient model of a full HTGR primary and secondary. This paper introduces two new open-source models for a HTGR and corresponding balance of plant (BOP) written for the HYBRID library developed at Idaho National Laboratory. A transient thermal load follow test case was taken by the work from Brits et al. to benchmark our open-source model against transient operation results from other proprietary codes that exist. The control scheme for the two new models in combination is discussed and a comparison of the response in transient load follow between the two codes performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗