Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Field-resolved space–time characterization of few-cycle structured light pulses

Accompanied by the rapid development of ultrafast laser platforms in recent decades, the spatiotemporal manipulation of ultrashort laser pulses has attracted much attention due to the potential for cutting-edge applications of structured light, including optical tweezers, optical communications, super-resolution imaging, time-resolved spectroscopy in molecules and quantum materials, and strong-field physics. Today, techniques capable of characterizing the full spatial, temporal, and polarization state properties of structured light are strongly desired. Here, we demonstrate a technique, termed 3D TIPTOE, for characterizing structured mid-infrared waveforms, which uses only a two-dimensional silicon-based image sensor as both the detector and the nonlinear medium. By combining the advantages of the sub-cycle time resolution afforded by nonlinear excitation and the spatial resolution inherent to the two-dimensional sensor, the 3D TIPTOE technique allows full characterization of structured electric fields, significantly reducing the complexity of detection compared to other techniques. The validity of the technique is established by measuring both few-cycle Bessel–Gaussian pulses and radially polarized femtosecond vector beams.

Liu, Yangyang (ORCID:0000000335205332)↗

Heating neutron stars with GeV dark matter

An old neutron star (NS) may capture halo dark matter (DM) and get heated up by the deposited kinetic energy, thus behaving like a thermal DM detector with sensitivity to a wide range of DM masses and a variety of DM-quark interactions. Near future infrared telescopes will measure NS temperatures down to a few thousand Kelvin and probe NS heating by DM capture. We focus on GeV-mass Dirac fermion DM (which is beyond the reach of current DM direct detection experiments) in scenarios in which the DM capture rate can saturate the geometric limit. For concreteness, we study (1) a model that invokes dark decays of the neutron to explain the neutron lifetime anomaly, and (2) a framework of DM coupled to quarks through a vector current portal. In the neutron dark decay model a NS can have a substantial DM population, so that the DM capture rate can reach the geometric limit through DM self-interactions even if the DM-neutron scattering cross section is tiny. We find NS heating to have greater sensitivity than multipion signatures in large underground detectors for the neutron dark decay model, and sub-GeV gamma-ray signatures for the quark vector portal model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Core–Shell Gold Nanoparticle-Star Copolymer Composites with Gradient Transfer and Transport Properties: Toward Electro-Optical Sensors and Catalysis

A series of hybrid core–shell nanomaterials was prepared by solvent phase transfer methods with gold (Au) nanoparticles (NPs) as a core and star copolymers (h-PEI-b-PCL-Cbz) as a shell—consisting of hyperbranched polyethyleneimine (h-PEI) with different poly(ε-caprolactone) (PCL) chain lengths and a carbazole-contained terminating agent (Cbz). By varying the PCL chain length, these core–shell nanomaterials exhibited gradient energy transfer properties, surface hydrophobicity, electropolymerizability, and ionic probe transport and diffusion properties. The systematic copolymer formation was verified with quadruple-detector size exclusion chromatography (SEC) and 1H nuclear magnetic resonance (NMR). High-resolution atomic force microscopy-infrared spectroscopy (AFM-IR) chemical mapping verified nanoparticle-substrate adhesion and film formation. The design of these hybrid NPs and elucidation of gradient properties will be useful for future applications of the core–shell systems in electro-optical sensing and catalysis.

36 MATERIALS SCIENCE↗

Large-volume centimeter-wave cavities for axion searches

The scan rate of an axion haloscope is proportional to the square of the cavity volume. In this paper, a new class of thin-shell cavities are proposed to search for axionic dark matter. These cavities feature active volume much larger (>20×) than that of a conventional cylindrical haloscope, comparable quality factor Q, and a similar frequency tuning range. Furthermore, full 3D numerical finite-element analyses have been used to show that the TM 010 eigenmodes are singly polarized throughout the volume of the cavity and can facilitate axion-photon conversion in uniform magnetic field produced by a superconducting solenoid. To mitigate spurious mode crowding and volume losses due to localization, a pre-amplification binary summing network will be used for coupling. Because of the favorable frequency-scaling, the new cavities are most suitable for centimeter-wavelength (~ 10–100 GHz), corresponding to the promising post-inflation axion production window. In this frequency range, the tight machining tolerances required for high-Q thin-shell cavities are achievable with standard machining techniques for near-infrared mirrors.

79 ASTRONOMY AND ASTROPHYSICS↗

Acquisition and Processing Considerations for Infrared Images of Rotating Turbine Blades

Abstract As designers aim to increase efficiency in gas turbines for aircraft propulsion and power generation, spatially resolved experimental measurements are needed to validate computational models and compare improvement gains of new cooling designs. Infrared (IR) thermography is one such method for obtaining spatially resolved temperature measurements. As technological advances in thermal detectors enable faster integration times, surface temperature measurements of rotating turbine blades become possible to capture including the smallest features. This paper outlines opportunities enabled by the latest IR detector technologies for capturing spatially resolved rotating blade temperatures, while also addressing some of the challenges of implementing IR for turbine rigs such as the one in the Steady Thermal Aero Research Turbine (START) Laboratory. This paper documents critical steps in achieving accurate measurements including calibration, integration times, spatial noise, and motion blur. From these results, recommendations are provided for achieving accurate IR measurements collected in a rotating turbine facility to study film cooling.

Engineering↗

Laser Characterization of Optically Smooth BREAD parts

The Broadband Reflector Experiment for Axion Detection is a dish antenna experiment probing the axion and dark photon parameter space in the [1 μeV, 1 eV] mass range, or [.02, 200] THz frequency range. In the pilot design for the InfraBREAD model, the dish antenna includes an optically smooth coaxial parabolic reflector to focus incoming photons in the near Infrared spectrum, created by the spontaneous photoconversion of axions and dark photons, onto a Superconducting Nanowire Single Photon Detector at the focus point of the reflector. As the pilot begins as a dark photon detector, sensitivity estimates hypothesize that it could cover unprobed parameter space in the search for the dark photon. Because of this, it is of critical importance that the reflector and SNSPD be placed at the correct points in the dish antenna, as previous work has shown that in addition to the focal spot of the photons being smeared to an area larger than the SNSPD, detection efficiency is s ensitive to shifts on the millimeter scale. In order to constrain this barrier to efficiency, the reflector had its focal spot, roughness, and length of surface waves measured by lasers in an optical bench setup. Results show the focal point diverging slightly from its theorized position in the antenna, while uncertainty in the height at which the detector should be placed was constrained to 10s of microns, the uncertainty in radial position could not be constrained to smaller than the detector given the methods used. Results for the roughness and surface wavelength show that the reflector was uniformly machined in a diamond-turning process used to fabricate optically smooth parts, as well as support a roughly 90% detection efficiency, reinforcing the sensitivity estimates presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

iSHELL: a 1–5 micron R = 80,000 Immersion Grating Spectrograph for the NASA Infrared Telescope Facility

iSHELL is a 1.06–5.3 μm high spectral resolution spectrograph built for the 3.2 m NASA Infrared Telescope Facility (IRTF) on Maunakea, Hawaii. Dispersion is accomplished with a silicon immersion grating in order to keep the instrument small enough to be mounted at the Cassegrain focus of the telescope. The white pupil spectrograph produces resolving powers of up to about R ≡ λ/δλ = 80,000 (0."375 slit). Cross-dispersing gratings mounted in a tiltable mechanism allow observers to select different wavelength ranges and, in combination with a slit wheel and Dekker mechanism, slit widths ranging from 0."375 to 4."0 and slit lengths ranging from 5" to 25". One Teledyne 2048 × 2048 HAWAII-2RG array is used in the spectrograph, and one Raytheon 512 × 512 Aladdin 2 array is used in a 1–5 μm slit viewer for object acquisition, guiding, and scientific imaging. iSHELL has been in productive regular use on IRTF since first light in 2016 September. In this paper we discuss details of the science case, design, construction and astronomical use of iSHELL.

79 ASTRONOMY AND ASTROPHYSICS↗

UA'(1): The search for low-mass dark matter in liquid xenon / Infrared Light for Liquid Xenon TPCs

Liquid xenon-based time projection chambers are used in a variety of applications spanning from the search for dark matter or signals from coherent neutrino-nucleus scattering, to detectors used in medicine and for nuclear non-proliferation. Extending the useful energy range of these detectors down to lower energies will prove extremely useful for such applications. However, various sources of single- and few-electron backgrounds limit the utility of experiments such as LZ and XENONnT to searches of lighter dark matter articles in the MeV mass range. These same backgrounds also limit their utility to measure signals from coherent neutrino-nucleus scattering of solar boron-8 neutrinos and Galactic supernovae. This research worked on multiple mitigation strategies to reduce these backgrounds, through improved xenon purity, infrared irradiation, and an improved theoretical understanding. Multiple dedicated liquid xenon setups were built to execute those tests, and data was successfully taken. Liquid xenon purity was shown to have an important impact, but infrared irradiation did not reduce these backgrounds.

47 OTHER INSTRUMENTATION↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in Bio-Oils: Laboratory Analytical Procedure (LAP)

The determination of total carbon, hydrogen, and nitrogen in bio-oils is important as these values can be used to track the carbon balance of production processes as well as calculate total oxygen content by difference. Oxygen content of bio-oils is a key metric for production and upgrading strategies as these are typically aimed at reducing oxygen. Oxygenates in bio-oils contribute to poor hydrocarbon miscibility, high acidity, high viscosity, and poor stability. Upgrading of bio-oils via deoxygenation produces hydrocarbons which can be used to generate feedstocks for renewable fuels and chemicals. In this Laboratory Analytical Procedure (LAP), combustion-based ultimate analysis is used to determine the weight percent (wt%) of C, H, and N in bio-oils and upgraded products. Ultimate analysis uses high temperatures and a pure oxygen environment to completely combust organic samples to carbon dioxide (CO 2 ), water (H 2 O), and nitrogen oxides (NO x ). In this procedure the amount of C and H in the sample are quantified by measuring resultant CO 2 and H 2 O with Fourier-transform infrared spectroscopy (FTIR). For N, NO x is reduced to nitrogen (N 2 ) which is measured with a thermal conductivity detector (TCD), providing total N content.

09 BIOMASS FUELS↗

Measurements of multijet event isotropies using optimal transport with the ATLAS detector

A measurement of novel event shapes quantifying the isotropy of collider events is performed in 140 fb -1 of proton-proton collisions with $\sqrt{s}$ = 13 TeV centre-of-mass energy recorded with the ATLAS detector at CERN’s Large Hadron Collider. These event shapes are defined as the Wasserstein distance between collider events and isotropic reference geometries. This distance is evaluated by solving optimal transport problems, using the ‘Energy-Mover’s Distance’. Isotropic references with cylindrical and circular symmetries are studied, to probe the symmetries of interest at hadron colliders. The novel event-shape observables defined in this way are infrared- and collinear-safe, have improved dynamic range and have greater sensitivity to isotropic radiation patterns than other event shapes. The measured event-shape variables are corrected for detector effects, and presented in inclusive bins of jet multiplicity and the scalar sum of the two leading jets’ transverse momenta. The measured distributions are provided as inputs to future Monte Carlo tuning campaigns and other studies probing fundamental properties of QCD and the production of hadronic final states up to the TeV-scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of the Fermilab Constant Fraction Discriminator ASIC

Here, we present the design and performance characterization results of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout low gain avalanche detector (LGAD) signals by directly using a constant fraction discriminator (CFD) to measure signal arrival time. Silicon detectors with time resolutions less than 30ps will play a critical role in future collider experiments, and LGADs have been demonstrated to provide the required time resolution and radiation tolerance for many such applications. The FCFD has a specially designed discriminator that is robust against amplitude variations of the signal from the LGAD that normally requires an additional correction step when using a traditional leading edge discriminator. The application of the CFD directly in the ASIC promises to be more reliable and reduces the complication of evolving time-walk corrections throughout the operational lifetime of the detector system. We will present a summary of the measured performance of the FCFD for input signals generated by internal charge injection, LGAD signals from an infrared laser, and LGAD signals from minimum-ionizing particles. The mean time response for LGAD signals with charge ranging between 5 and 26 fC has been measured to vary no more than 10ps, orders of magnitude more stable than an uncorrected leading edge discriminator based measurement, and effectively removes the need for any additional time-walk correction. The measured contribution to the time resolution from the FCFD ASIC is found to be 10ps for signals with charge above 20fC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-phase characterization of pitch-carbon coated nano-silicon anodes for lithium-ion batteries

Silicon (Si) is a leading next-generation Li-ion battery anode candidate that meets rigorous performance demands for portable power including enhanced power and energy density with robust cycling performance. However, a series of complex and interrelated reactions lead to reduced calendar life in Si-containing systems and therefore challenge practical adoption. In the present work, we probe the mechanisms underlying observed performance improvements by adding a pitch-carbon coating onto nano-Si material. We pair solid-phase (X-ray photoemission spectroscopy, Fourier-transform infrared), semi-volatile phase (solid-phase microextraction-gas chromatography-mass spectrometry), and gas-phase (gas chromatography-flame-ionization detector) characterization signals to comprehensively evaluate the impact of pitch-carbon coating on the evolution of the Si solid-electrolyte interphase (SEI) and the associated impacts on electrode/electrolyte reactivity. The pitch-carbon is found to serve as a physicochemical barrier, reducing the electro-active surface area for Si/electrolyte reactivity and preventing Si oxidation. Further, the pitch-carbon coating promotes the evolution of a more-favorable SEI by subsuming substantial functionality typically associated with the fluoroethylene carbonate (FEC) electrolyte additive - such as alkoxide scavenging and suppression of transesterification pathways - and by shifting the competitive electrolyte degradation pathways' favorability. The multi-phase characterization approach enables holistic end-products evaluation from complex (electro)chemical interfacial reactions, which informs a robust interpretation of the carbon coating's role in electrochemical performance improvements. The present mechanistic evaluation aids the rational design for improved nano-Si materials.

25 ENERGY STORAGE↗

Investigation of signal characteristics and charge sharing in AC-LGADs with laser and test beam measurements

AC-LGADs, also referred to as resistive silicon detectors, are a recent development of low-gain avalanche detectors (LGADs), based on a sensor design where the multiplication layer and n + contact are continuous, and only the metal layer is patterned. In AC-LGADs, the signal is capacitively coupled from the continuous, resistive n + layer over a dielectric to the metal electrodes. Therefore, the spatial resolution is not only influenced by the electrode pitch, but also the relative size of the metal electrodes. Signal propagation between the metallized areas and charge sharing between electrodes plays a larger role in these detectors than in conventional silicon sensors read out in DC mode. AC-LGADs from two manufacturers were studied in beam tests and with infrared laser scans. The impact of n + layer resistivity and metal electrode pitch on the charge sharing and achievable position resolution is shown. For strips with 100 μm pitch, a resolution of ¡ 5 μm can be reached. Additionally, the charge sharing between neighboring strips is investigated in more detail, indicating the induction of signal charge and subsequent re-sharing over the n + layer. Furthermore, an approach to identify signal sharing over large distances is presented.

47 OTHER INSTRUMENTATION↗

Utilisation of spatial derivative measurements in circular diffuse optical tomographic imaging to improve image resolution and contrast

The resolution of images recovered using diffuse optical tomography without spatial prior information is inherently limited due to the diffusive nature of light transport in scattering dominated biological tissue. Several studies have previously reported an improvement in depth sensitivity in near infrared spectroscopy by considering the subtraction of two neighbouring measurements. A nearest neighbour, spatial derivative based algorithm is presented, in which the difference between neighbouring source-sharing source – detector pairs is considered for tomographic reconstruction. Using a circular, inward-facing optode geometry, it is shown that deeper abnormalities in oxyhaemoglobin, deoxyhaemoglobin and water can be recovered with better localisation and contrast as compared to reconstructing using absolute values of multi-wavelength data. Relative improvements of up to 25 % in quantitative accuracy of recovered physiological values are demonstrated at better resolution for cancerous tissue in a heterogeneous breast model, when using this proposed spatial derivative based parameter reconstruction. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical versus radiographic imaging and tomography: introduction to the ROADS feature issue

Optical imaging is an ancient branch of imaging dating back to thousands of years. Radiographic imaging and tomography (RadIT), including the first use of X-rays by Wilhelm Röntgen, and then, $γ$ -rays, energetic charged particles, neutrons, etc. are about 130 years young. The synergies between optical and radiographic imaging can be cast in the framework of these building blocks: Physics, Sources, Detectors, Methods, and Data Science, as described in Appl. Opt. 61, RDS1 (2022). Optical imaging has expanded to include three-dimensional (3D) tomography (including holography), due in to part the invention of optical (including infrared) lasers. RadIT are intrinsically 3D because of the penetrating power of ionizing radiation. Both optical imaging and tomography (OIT) and RadIT are evolving into even higher dimensional regimes, such as time-resolved tomography (4D) and temporarily and spectroscopically resolved tomography (4D + ). Further advances in OIT and RadIT will continue to be driven by desires for higher information yield, higher resolutions, and higher probability models with reduced uncertainties. Synergies in quantum physics, laser-driven sources, low-cost detectors, data-driven methods, automated processing of data, and artificially intelligent data acquisition protocols will be beneficial to both branches of imaging in many applications. These topics, along with an overview of the Radiography, Applied Optics, and Data Science virtual feature issue, are discussed here.

47 OTHER INSTRUMENTATION↗

Conversion of Phenolic Oil from Biomass Pyrolysis into Phenyl Esters

Bio-oil is among the most economical approaches for advanced biofuel production. However, bio-oil faces several challenges including high acidity and viscosity, poor storage, and thermal stability. This study focuses on the upgradation of lignocellulosic (corn stover and yellow pine) bio-oil derived phenolic oil (PO), produced by the autothermal fast pyrolysis, through acid-catalyzed esterification reaction. Our strategy exploits a little recognized chemistry: the Fischer esterification of PO and carboxylic acids into carboxylic acid phenyl esters (CAPE) using Dean Stark distillation. Analyses by the Folin–Ciocalteu method, Karl Fischer titration, gas chromatography flame ionization detector, and the molecular weight determination by gel permeation chromatography suggest the conversion of 50 wt% added phenolics to their corresponding CAPE. The Fourier transform infrared spectroscopy analysis confirmed the formation of new C=O and two C–O stretching bands and decrease in the intensity of phenolic-OH bands in the CAPE. The 13 C NMR analysis supports the formation of CAPE together with some unreacted precursors. A base-catalyzed ester hydrolysis experiment and mass balance calculation show an excellent agreement (within 5% range) of the equivalent weight between the produced ester and the phenyl hexanoate. Brookfield analysis indicates that CAPE has 330-fold lower viscosity than starting PO. Heating values of CAPE were higher than PO, from which they were derived (42.2 and 43.6%, respectively, for PO from pyrolysis of corn stover and yellow pine), while moisture content decreased by 98.3 and 98.7%, respectively. The CAPE, which is a phenolic analogue of methyl esters used in biodiesel, has improved stability compared to PO from which it was derived.

42 ENGINEERING↗

Large-scale efficient mid-wave infrared optoelectronics based on black phosphorus ink

The mid-wave infrared (MWIR), ranging from 2 to 5 micrometers, is of substantial interest for chemical sensing, imaging, and spectroscopy. Black phosphorus (bP)–based MWIR light emitters and detectors have been shown to outperform the state-of-the-art for commercial devices due to the low Auger recombination coefficient of bP. However, the scalability of these devices remains a challenge. Here, we report a bP ink formula that preserves the exceptional MWIR optoelectronic properties of bP to deposit centimeter-scale, uniform, and pinhole free films with a photoluminescence quantum yield higher than competing III-V and II-VI semiconductors with similar bandgaps at high excitation regime. As a proof of concept, we use bP ink as a “phosphor” on a red commercial light-emitting diode to demonstrate bright MWIR light emission. We also show that these films can be integrated into heterostructure device architectures with electron and hole selective contacts for direct-injected light emission and detection in MWIR.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗