Grid-Forming and -Following Background, Future, and Strategies

This paper reviews current grid forming (GFM) and grid following (GFL) inverter control strategies and explores the optimized ratio between these assets in high-penetration inverter-based resource (IBR) grids. Two case studies demonstrate that an insufficient GFM ratio leads to instability, while increasing GFM participation improves fault recovery, voltage stability, and frequency regulation.

14 - SOLAR ENERGY↗

Evaluating Protection System Performance for a Real-World Weak Grid Area With High Inverter-Based Resources: Preprint

This paper evaluates an existing protection scheme implemented in a real-world weak grid area with a high penetration of inverter-based resources (IBRs). The study aims to assess the reliability and adequacy of protection schemes originally designed for traditional synchronous machine systems and determine whether they can continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with an IBR original equipment manufacturer black-box model is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. These findings provide utilities with valuable insights for improving their protection systems in high-IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

UNIFI's Grid-Forming (GFM) Inverter Reference Design: A Tutorial on Modeling, Control, and Experimental Implementation of GFM Inverters

The UNIFI Consortium's tutorial on grid-forming (GFM) inverters provides a comprehensive guide to the modeling, control, and experimental implementation of GFM inverters. As the integration of renewable energy accelerates, the transition from traditional grid following (GFL) to GFM inverters is crucial to ensure stable and sustainable power systems. This document outlines a reference design for three-phase and single-phase GFM inverters developed at the University of Texas at Austin. The tutorial also provides step-by-step guidance for accessing and using UNIFI’s GitHub repository, enabling users to design, build, and test GFM inverters efficiently. By fostering collaboration and equipping users with accessible resources, this initiative aims to drive widespread adoption of GFM technology across academia, utilities, and industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency-Nadir-Constrained Unit Commitment for Low-Inertia, High-IBR Island Power Systems [Slides]

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

14 SOLAR ENERGY↗

Critical Energy Infrastructure Cybersecurity: Enhanced Cyber Resilience for Federal Energy Systems

This presentation is an overview of FEMP Resilient and Secure Infrastructure and Facilities. An educational and interactive workshop centered on resilient and secure federal infrastructure and facilities, with a focus on inverter-based resources at Federal sites, building automation systems, and Federal supply chains. This workshop will illustrate an all-hazards scenario and discuss how Federal agencies can be positioned to resist these real-world scenarios.

97 MATHEMATICS AND COMPUTING↗

Leveraging Cloud Platforms for Grid Modernization

Overview of the DOE funded Grid Operator Analytics and Assessment tools for Inverter-Based Resources Dominated Grid (GOAAT-IBR) Project, including insight to the lab setup and event analysis and dashboards that are being developed for this project.

Aminifar, Ph.D., Farrokh↗

Analysis of Line Distance Elements for Various Ibr Controllers and System Conditions

The large-scale penetration of inverter-based resources in power systems has challenged protection engineers because of the different fault behaviors these sources provide compared to conventional generation systems. The main challenges include a low level of fault current magnitude, unpredictable angles of sequence currents, and lack of inertia that can lead to maloperation of conventional phasor-based protection elements. This paper presents a sensitivity analysis of transmission line distance protection elements during phase-to-ground and phase-to-phase faults for different inverter controllers and power system conditions. It also summarizes which line protection elements remain secure near IBR terminations and identifies the ones affected by the inverter-based response. The paper concludes by highlighting that regulating negative-sequence current injection during the fault aids correct protection decisions, but does not address the entire challenge. Finally, alternative protection elements to those affected by the inverter fault response are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Digital Twin for an Inverter-Based Resource Power Plant: Real-time data streaming unlocks situation awareness

Here, this study presents the development and successful implementation of a digital twin specifically designed for a grid-connected IBR power plant. By integrating a reduced-order model of the IBR system and dynamically updating the grid impedance with real-time data, the digital twin effectively captures and replicates the behavior of the physical system. Its accuracy and reliability are validated through critical test scenarios, including a three-phase fault and a line-tripping event. The results confirm that the digital twin closely emulates its physical counterpart, demonstrating its strong potential for real-time analysis, system monitoring, and predictive decision making in modern power systems.

Digital twins↗

UNIFI Specifications for GFM IBRs (V3) and Transitioning to an IEEE Standard [Slides]

This presentation describes version 3 of the grid-forming (GFM) specifications for inverter-based resources developed by the UNIFI (Uniform Interoperability for Grid-Forming Inverters) Consortium. It summarizes the requirements for GFM inverters, the four categories of GFM capability, and the tests designed to assess GFM capability. The tests including time-domain tests similar to those in use by some industry entities and frequency-domain tests that are largely new. This presentation also describes ongoing efforts to use the UNIFI GFM specifications as the starting point for a new IEEE standard called IEEE P2800.1.

14 SOLAR ENERGY↗

Impact of Geomagnetic Induced Current Neutral Blocking Devices on Distance Relays in Sub-transmission Networks with IBR

Geomagnetically induced currents (GICs) can flow through transmission lines during geomagnetic disturbances, such as solar flares or coronal mass ejections. These currents can cause problems like transformer saturation and equipment damage. The most common method of mitigating GICs involves installing GIC neutral blocking devices (NBDs) in transformer neutrals. However, the wide application of capacitive GIC blocking devices may have unintended adverse effects on other devices, such as distance protection relays. As the number of inverter-based resources being connected to the transmission and sub-transmission systems increases, the likelihood of a sub-transmission line protected by a distance relay connected to a transformer with NBDs is increasing. Therefore, distance relays fed by IBRs and transmission lines with GIC-NBDs must be studied. This paper studies the effect of GIC-NBDs on a 69kV sub-transmission line of various lengths fed by a 25 MVA IBR and synchronous source. This work focused on the behavior of the GIC-NBDs using the measured apparent phase-to-ground and phase-to-phase impedance calculated by the relay and the source impedance ratio (SIR) during various electrical faults.

Patel, Trupal R [Sandia National Laboratories (SNL↗

Model of Inverter-Based Resources

Blackbox modelling for SC analysis is a possible solution. Accuracy can be acceptable even without having vendor control diagrams. Is an NDA required to share a vendor Blackbox model for SC analysis? Differences in VRT detection and injection logics. Angle rotation is not addressed in control logics of most vendors. Current limitation logic during unbalanced faults is not clear. Model IBR as a current source with shunt to improve convergence

IBRs, Model of IBRs, Short Circuit Analysis, Class↗

Modeling and Automation Framework for High IBR Integration in Large-Scale Power Systems

The increasing prevalence of power electronics- interfaced renewable generation sources is leading to a gradual replacement of traditional thermal generation-based synchronous machines. In this context, the modeling of a large-scale power grid that incorporates a significant number of inverter-based resources is crucial for understanding the dynamics and effects of these resources on the power system. This study investigates the positive sequence model of grid-following and grid-forming inverters. Additionally, this work explores the integration of distributed energy resources using population as an indicator of their relative geographic locations. To address challenge to integrate these inverter based resources into a realistic grid of the US Western interconnection, automation scripts are developed to streamline the process of replacing conventional generators with grid-following and grid-forming inverters, as well as allocating distributed energy resources. Different penetration levels of these inverters are considered, and their frequency regulation support following a disturbance is compared through dynamic simulations.

Lyu, Xue↗

Impact of K-factor on Short Circuit Program Convergence for Inverter-Based Resources during Faults

Classical short-circuit programs that linearize the power network are no longer applicable for inverter based resources (IBRs), necessitating an iterative approach. Phasor domain programs can model the IBRs using an iterative approach considering nonlinear fault responses. In phasor domain models, the IBR can be modeled as a voltage controlled current source (VCCS) in tabular form with positive, negative, and zero sequence information for balanced and unbalance short-circuit faults. In the VCCS modeling of the IBR, positive and negative incremental reactive current, also known as the k-factor, plays an important role in short circuit program convergence. In this work, a few approaches: conventional VCCS modeling with a k-factor of 2, conventional VCCS modeling with a k-factor of 2 with modified pre-fault voltages, VCCS characteristics based on the power flow solution with a k-factor of 2, and VCCS characteristics based on the power flow solution with a k-factor of 1 are investigated for short circuit program convergence under higher IBR penetration. The IEEE 39 bus New England Test System is taken as the test system, and simulations are carried out in PSS®CAPE 15.0.26 simulation software. Simulation results demonstrate that IBR penetration is higher for the VCCS model, which corresponds to the power flow solution with k-factor 1, compared to other approaches.

42 ENGINEERING↗

T&D LIBRA: Simulation Framework for Transmission and Distribution Load and IBR Assessment

This paper introduces T&D LIBRA, a HELICS-based dynamic co-simulation framework designed for transmission and distribution (T&D) load and inverter-based resource assessment. This framework is designed to model interactions between single-phase induction motors (i.e., Motor-D), distributed energy resources (DERs) and the transmission network, emphasizing system stability during fault conditions. The primary objective of this research is to study the fault-induced delayed voltage recovery (FIDVR) behavior of the T&D networks using the co-simulation framework and to compare the results with conventional PSS/E only simulations. Simulations are validated using T&D co-simulations with a single distribution node and the IEEE 123-bus distribution test case. The co-simulation results demonstrate the value of using T&D co-simulations to capture motor stalling, DER tripping and other sources of voltage diversity on distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗