Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Chemical clocks: using otolith geochemistry to enhance estimation of age and growth of white hake (Urophycis tenuis)

The white hake (Urophycis tenuis) is a groundfish distributed throughout the Gulf of Maine. Catch advice is based on stock assessments done with age-based population dynamics models; however, otolith aging is challenging because of unclear growth increments. To address this concern, we compared the consistency of aging with counts of visual annuli to that of aging with cycles of elemental concentrations measured by using laser ablation inductively coupled plasma mass spectrometry. We tested the hypothesis that oscillations in both environmental conditions and internal physiology through time influence uptake of elements during otolith mineralization. Concentrations of manganese, in comparison with those of the other investigated trace elements (magnesium, strontium, and barium), had the most promising correlation with visual growth increments (~100% age agreement, ±1 year), offering an additional tool to enhance increment identification. In our examination of 550 otoliths collected during 2007–2021, we found that white hake lived a maximum of 10.3 years and exhibited sexual dimorphism in maximum length and age. By using generated von Bertalanffy growth functions, L(t)=110(1–e–0.113(t+0.45)) for males and L(t)=140(1–e–0.113(t–0.30)) for females (where L(t) is length at time t), size and age at maturity were calculated for males (37.4 cm in total length (TL), 3.3 years) and females (47.4 cm TL, 4.2 years). These results demonstrate that otolith geochemistry can be used to improve the accuracy and precision of the estimation of fish age and maturity, even for challenging species.

59 BASIC BIOLOGICAL SCIENCES↗

Development of Short-Pulse Laser-Based Diagnostics for Pulsed Power-Driven Warm Dense Matter

This report summarizes a research project conducted at the Physics Department’s Zebra Pulsed Power Laboratory (ZPPL) at the University of Nevada Reno, aimed at developing short-pulse laser-based diagnostics to probe pulsed-power-driven warm dense matter. ZPPL combines a MegaAmpere (MA) pulsed power generator, Zebra, and a relativistic intensity, short-pulse laser, Leopard, offering a unique university-scale platform for high energy density physics, laboratory astrophysics, and inertial fusion energy research. The project focused on establishing a hard X-ray radiographic capability using high-intensity, short-pulse laser-generated X-rays to probe warm dense matter created by the Zebra current. Initial experiments produced X-ray radiographs of a static (cold) aluminum wire using silver and gold foil and wire targets, but intense background radiation from Zebra shots overwhelmed the laser-produced X-rays. To mitigate this, a radiationhardened detector housing was designed and implemented. Additional diagnostic, including a filter stack bremsstrahlung spectrometer and an X-ray pinhole camera, were developed to characterize laser-produced hard X-ray spectra and locate hard X-ray sources in the vacuum chamber. These revealed that strong hard X-rays (> 20 keV) originated near the anode cap, bombarded by energetic electrons. Due to laser unavailability during some experiments, detector performance was successfully tested using hard X-ray sources from the Zebra current, demonstrating their readiness for coupled experiments. The project supported one Ph.D. student (Dr. Lei Chen), who conducted experimental and numerical research, and provided training opportunities and data for three undergraduate senior theses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of a multi-kW, large-aperture gas-cooled Faraday rotator

We characterize a large-aperture gas-cooled Faraday rotator (FR) designed to mitigate stress-induced depolarization in high-energy, high-power laser systems. The rotator, based on ceramic TGG, was tested using a 150 mW probe beam at 1047 nm and a pump beam at 1070 nm. Compensating for the birefringence induced by the surrogate depolarization plate at 3.3 kW of effective pump power, the rotator reduces the spatially in-homogeneous depolarized light containing linear, circular, and elliptical polarization states to nearly linear with approximately 0.8% (or −21 dB) of residual depolarized energy. The FR demonstrated effective depolarization compensation across its 58×58 mm 2 aperture.

47 OTHER INSTRUMENTATION↗

Increased electron, positron, and x-ray production from high intensity laser interactions using micro-wire targets

We report increases in energetic electrons, positrons, and x-rays emitted from high-intensity laser interactions (10 18−20 W/cm 2 ) with structured silicon micro-wires on the surface of a 1 mm gold converter target using a 10 ps laser pulse. A total of four different wire configurations are tested, where the gaps (7–28 μm) between the wires and the thicknesses (3–6 μm) of the wires are varied, while the height remains constant (⁠ ~25 μm). We observe the largest enhancement in electrons, positrons, and x-rays with the sparsest wire configurations. The electron temperature (T e ≈6 MeV) remains consistent across all shots, regardless of whether wires or planar targets are used. This suggests that the observed enhancement is due to increased laser light absorption by the accelerated electrons over a long scale length. Two-dimensional particle-in-cell simulations confirm that absorption is significantly enhanced with the wire target. Additionally, specific simulations examining laser pointing on different parts of the wire structure reveal that, while the final electron spectrum remains largely insensitive, the angular distribution is highly sensitive to these variations.

Bremsstrahlung↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

General Testing Setup for Hyperelastic Transducers-DEEC-Tec & Marine Renewable Energy: Preprint

Distributed embedded energy conversion technologies (DEEC-Tec), an emerging domain for ocean wave energy conversion technology, is showing promise for a range of applications. Research is being conducted at the National Renewable Energy Laboratory that leverages this domain to investigate the potential of ocean wave energy converters (WECs) constructed from hyperelastic forms of distributable and embeddable energy transducers. These transducers are available in forms such as disks, rectangles, or hexagons and can be combined in various ways to form energy-producing metamaterials and flexible WECs. DEEC-Tec, therefore, could open doors that enhance ocean wave energy conversion in ways not previously thought possible by allowing for many WEC topologies and morphologies. However, the same diversity and adaptability pose challenges for the development of these DEEC-Tec-oriented hyperelastic transducers. A commercial tensile testing setup was not found that was adaptable enough to accommodate the varied transducers while providing precise force control, range of motion, and noncontact data collection. Because of this lack, a comprehensive test rig was designed in house to be used with a 3D laser scanning device-providing contactless measurements while also allowing for different geometries and various uniaxial loadings. This paper and presentation will discuss these unique challenges and the processes for overcoming them to provide a robust and general testing setup for hyperelastic transducers, of any form, for the DEEC-Tec marine renewable energy domain.

DEEC-Tec↗

Broadband 920-nm mirror thin film damage competition

The 2023 Laser Damage conference thin-film damage competition was devoted to a survey on the state-of-the-art broadband near-IR multilayer dielectric (MLD) mirrors designed for ultra-short pulsed laser applications. The requirements for the coatings were a minimum reflection of 99.5% at 45-deg incidence angle for S-polarization from 830 nm to 1010 nm and group delay dispersion (GDD) < ± 50fs 2 . The participants were allowed to select the coating materials, coating design, and coating deposition method. Samples were damage tested at a single testing facility to enable direct comparison among the participants using a 25 ± 5 fs optical parametric chirped-pulse amplification (OPCPA) laser system operating at 5 Hz. The testing results from this set of 37 samples showed that dense coatings by ion-beam sputtering (IBS), magnetron sputtering (MS), and electron-beam ion assisted deposition (e-beam IAD) exhibited highest damage initiation onset (laser-induced damage threshold or LIDT) while e-beam coatings were low performers. In addition, multilayer coatings using tantala and/or hafnia as high index materials were top performers. Furthermore, this competition included for the first time the measurement of the damage growth onset (laser-induced damage growth threshold or LDGT). This latter performance metric plays an important role in establishing the safe operational conditions for larger aperture ultrashort pulsed lasers. Information pertaining to the morphology of the damage sites and their evolution under subsequent exposure to different laser fluences leading to damage growth is presented. Finally, not all coating samples in the survey met the GDD requirements stated above and associated measurements are discussed in the context of the present and past thin-film damage competitions focused on similar broadband near-IR MLD coatings.

23 broadband high reflectors↗

Laser Spectroscopy of Exotic Atoms and Molecules Containing Octupole-Deformed Nuclei

This project investigated the nuclear, atomic, and molecular structure of exotic atoms and molecules containing actinide isotopes. These short-lived radioactive systems are challenging to produce and study in the laboratory, yet they offer unique opportunities for fundamental science. These nuclei are predicted to exhibit pear-shaped (octupole) deformation, a rare collective nuclear behavior that dramatically enhances their sensitivity to fundamental physics phenomena such as time-reversal- and parity-violating effects. Such enhancements make them ideal probes for exploring open questions in our understanding of the universe such as the origin of the matter–antimatter asymmetry of the universe. To realize these measurements, the project led the development of a new laser spectroscopy experiment at MIT, and later commissioned at the Facility for Rare Isotope Beams (FRIB) at Michigan State University: the Resonance Ionization Spectroscopy Experiment (RISE). RISE combines the spectroscopic precision of collinear laser spectroscopy with the sensitivity of particle-detection techniques, enabling measurements of rare isotopes produced at rates as low as a few ions per second. The beamline was designed, built, and installed, and was successfully commissioned at FRIB during the grant period. RISE is now a permanent capability of the FRIB facility, and has produced several results on the study of rare atoms and molecules for nuclear structure and fundamental symmetries. In parallel with the FRIB program, the project contributed to the first precision laser-spectroscopy measurements of short-lived radioactive molecules. Working with international collaborators at CERN's ISOLDE facility, the team conducted pioneering experiments on radium monofluoride (RaF) and actinium monofluoride (AcF). The results from this work have been published in major journals of science, including Nature, Science, Nature Physics, Nature Communications, and Physical Review Letters. These findings have guided future experiments on the laser cooling of radioactive molecules, opening a new platform for precision tests of fundamental symmetries.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Femto-second Laser’s Enabling New Length Scale Fabrications for Rapid Post Irradiation Examination of Materials: Concluding LDRD Project Poster

Mechanical testing campaigns are required to qualify materials for advanced reactor conditions, yet economical and safety limitations restrict the number of standardized mechanical tests that can be performed. Reducing the size of the sample is one approach to addressing these challenges and to accelerating testing. Previous research has shown that smaller mechanical test samples produce higher yield and ultimate stress values compared to values measured from standard sample sizes: the “smaller is stronger” effect. Specimens used in accelerated material testing campaigns must reflect bulk material performance to enable engineering scale material property measurement. The objective of this research project was to determine if engineering scale mechanical behavior—the yield stress—could be measured with micro-tensile test samples smaller than traditional standard testing geometries. The relationship between yield stress and sample size was explored with two different nuclear-relevant structural materials: Zircaloy-4 and tungsten. Mechanical testing of both metals demonstrated decreasing yield stress values with increasing sample gauge size across three different sizes. Yield stress values from the largest gauge size, fabricated with a femto-second laser ablation system, approach bulk material yield stress values reported in published literature. Preliminary analysis of the tungsten samples indicates the yield stress value depends on the grain characteristics within the gauge section, in addition to the gauge size. Accompanying modeling efforts, including response surface generation and crystal plasticity approaches, further demonstrated that the size of the sample gauge section alone cannot explain the change in yield stress values.

36 MATERIALS SCIENCE↗

Additive Manufacturing of Cryogenic Austenitic Steel JK2LB via Wire-Fed Directed Energy Deposition (DED) for Fusion Energy Applications

This study explores the feasibility of fabricating cryogenic austenitic steel JK2LB via both laser-based directed energy deposition (laser-DED) and arc-based directed energy deposition (arc-DED) additive manufacturing processes for potential application in fusion reactors. JK2LB, a low-nickel, high-manganese stainless steel developed for ITER, offers excellent cryogenic toughness, radiation resistance, and decay-to-clearance characteristics. Although JK2LB was originally designed to endure cyclic stresses at cryogenic temperatures in tokamaks, its low-temperature mechanical integrity and radiation tolerance also make it a promising candidate for structural components, such as the coil case/support structure in nonplanar high-temperature superconducting magnet assemblies in stellarators. Directed energy deposition (DED) additive manufacturing was selected for this study due to its capability to fabricate large structures with complex geometries. Here, to address the long lead time and high cost associated with acquiring conventional JK2LB solid wire, JK2LB powder-cored wire was developed as the feedstock material. Testing blocks were then fabricated using both wire-fed laser-DED and arc-DED processes. Microstructural and compositional analyses revealed that both DED approaches yield fully austenitic phase and columnar grain structures. Mechanical testing at room temperature revealed that both DED routes achieved yield strength and elongation comparable to those of conventionally processed JK2LB via vacuum melting, electroslag remelting, extrusion, and drawing, though ultimate tensile strength was reduced due to Mn loss and large columnar grains. As a study mainly focusing on the additive manufacturing process, this work demonstrates the potential of additive manufacturing for fusion energy applications and provides a basis for optimization and future cryogenic mechanical evaluation.

Cryogenic steel↗

Photovoltaics Research at NREL

General overview of NREL research, including scaling to terawatt PV, reliability testing, DuraMAT, perovskites, silicon PV, CdTe, III-V, and tandems.

CdTe↗

SULI Report - Development of a Molten Salt Circulation Loop for in-situ Spectroscopy

This project supports the development of real time optical monitoring capabilities for molten salt reactor (MSR) environments by designing, testing, and refining a molten salt circulation loop suitable for combined laser induced breakdown spectroscopy (LIBS) and ultraviolet visible (UV Vis) absorption measurements. Online spectroscopic monitoring is increasingly important for nuclear safeguards, corrosion tracking, and material accountancy, yet MSR process fluids present substantial challenges due to their chemical complexity and hazards such as high temperatures and radiation. To address these needs, this work focuses on Phase I, the development of a room temperature aqueous circulation loop that serves as a surrogate platform for evaluating flow behavior, optical access, and component performance prior to high temperature salt operation. Initial testing identified several practical issues—including leaks, obstructions, and two-phase flow through the absorption cell—that were systematically resolved through hardware replacement, flow path redesign, and venturi pressure optimization. Relocating the flow cell upstream of the primary venturi enabled periods of stable single-phase flow, demonstrating the feasibility of integrating optical diagnostics into a circulation system. The results of Phase I provide essential design insight for Phase II, which will incorporate furnace compatible materials and LiCl KCl eutectic salt. Completion of the molten salt system will deliver a reusable testbed for evaluating multimodal spectroscopic techniques, advancing nondestructive, real time monitoring tools for future MSR and nuclear fuel cycle applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Laser-plasma ion beam booster based on hollow-channel magnetic vortex acceleration

Laser-driven ion acceleration provides ultrashort, high-charge, low-emittance beams, which are desirable for a wide range of high-impact applications. Yet after decades of research, a significant increase in maximum ion energy is still needed. This paper introduces a quality-preserving staging concept for ultraintense ion bunches that is seamlessly applicable from the nonrelativistic plasma source to the relativistic regime. Full three-dimensional particle-in-cell simulations prove robustness and capture of a high-charge proton bunch, suitable for readily available and near-term laser facilities.

43 PARTICLE ACCELERATORS↗

FY25 Planned High-Temperature Mechanical Tests of LPBF 316H SS Performance at INL

This document is not the full report but contains the contribution to the Argonne National Laboratory’s Milestone which presents the consolidated research report on the laser powder bed fusion 316H material. This document provides an update on the creep and creep-fatigue test effort at Idaho National Laboratory.

316H Steel↗

Coherent frequency combs from electrons colliding with a laser pulse

Highly coherent and powerful light sources capable of generating soft x-ray frequency combs are essential for high precision measurements and rigorous tests of fundamental physics. In this work, we derive the analytical conditions required for the emission of coherent radiation from an electron beam colliding with a laser pulse, modeled as a plane wave. These conditions are applied in a series of numerical simulations, where we show that a soft x-ray frequency comb can be produced if the electrons are regularly-spaced and sufficiently monoenergetic. High quality beams of this kind may be produced in the near future from laser-plasma interactions or linear accelerators. Furthermore, we highlight the advantageous role of employing few-cycle laser pulses in relaxing the stringent monoenergeticity requirements for coherent emission. The conditions derived here can also be used to optimize coherent emission in other frequency ranges, such as the terahertz domain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗