Search NASA⌕ Search

SEARCH · Search NASA

Results for “long screened wells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

125 records · Page 7

Wilson Corners SWMU 001 2015 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2015 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration John F. Kennedy Space Center, Florida. The objectives of the 2015 LTM event were to evaluate the groundwater flow direction and gradient, to monitor the vertical and horizontal extent of the volatile organic compounds (VOCs; including the upgradient and sidegradient extents, which are monitored every five years), and to monitor select locations internal to the dissolved groundwater plume. The 2015 LTM event included several upgradient and sidegradient monitoring wells that are not sampled annually to verify the extent of VOCs in this portion of the site. The December 2015 LTM groundwater sampling event included, depth to groundwater measurements, 40 VOC samples collected using passive diffusion bags, and one VOC sample collected using low-flow techniques. Additionally, monitoring well MW0052DD was overdrilled and abandoned using rotasonic drilling techniques. The following conclusions can be made based on the 2015 LTM results: groundwater flow is generally to the west with northwest and southwest flow components from the water table to approximately 55 feet below land surface (ft BLS); peripheral monitoring wells generally delineate VOCs to groundwater cleanup target levels (GCTLs) except for monitoring wells MW0088, MW0090, MW0095, and NPSHMW0039, which had vinyl chloride (VC) concentrations near the GCTL and MW0062, which had trichloroethene (TCE), cis-1,2-dichloroethenen (cDCE), and VC concentrations above natural attenuation default concentrations (NADCs); VOCs in interior downgradient wells generally fluctuate within historic ranges except for monitoring wells in the north-northwest portion of the site, which have increasing VC concentrations indicating potential plume migration and expansion; Historically, the vertical extents of the VOCs were delineated by monitoring wells screened greater than 60 ft BLS (MW0083 through MW0086, and MW0078). The 2015 LTM results indicate that concentrations of daughter product cDCE is greater than the NADC in MW0078 and that cDCE and VC are greater than NADCs in MW0130. TCE was greater than the GCTL in monitoring well MW130 and not detected above method detection limits (9 micrograms per Liter) in monitoring well MW0078. No GCTL exceedances were identified in monitoring wells MW0083 or MW0086; the dissolved plume footprint appears generally stable, though not fully delineated by monitoring well data in the northeast portion of the site; and 2015 LTM results generally support the existing Conceptual Site Model. Geosyntec recommends modifying the LTM program, collecting a verification sample from monitoring well MW0062, and performing a direct push technology instigation in the northnortheastern portion of the site. A cluster of monitoring wells (MW0132 [2 to 12 ft BLS], MW0133 [15 to 25 ft BLS], and MW0134 [29 to 34 ft BLS]) is proposed to delineate impacts in the northnortheast portion of the site. Geosyntec recommends installation of a vertical extent well in the center of the site (Hot Spot 2 area) post-remediation implementation.

groundwater↗

Know Your Enemy - Implementation of Bioremediation within a Suspected DNAPL Source Zone Following High-Resolution Site Characterization at Contractors Road Heavy Equipment Area, Kennedy Space Center, Florida

The National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), has adopted high-resolution site characterization (HRSC) sampling techniques during baseline sampling prior to implementation of remedies to confirm and refine the conceptual site model (CSM). HRSC sampling was performed at Contractors Road Heavy Equipment Area (CRHE) prior to bioremediation implementation to verify the extent of the trichloroethene (TCE) dense non-aqueous phase liquid (DNAPL) source area (defined as the area with TCE concentrations above 1% solubility) and its daughter product dissolved plume that had been identified during previous HRSC events. The results of HRSC pre-bioremediation implementation sampling suggested that the TCE source area was larger than originally identified during initial site characterization activities, leading to a design refinement to improve electron donor distribution and increase the likelihood of achieving remedial objectives. Approach/Activities: HRSC was conducted from 2009 through 2014 to delineate the vertical and horizontal extent of chlorinated volatile organic compounds (CVOCs) in the groundwater. Approximately 2,340 samples were collected from 363 locations using direct push technology (DPT) groundwater sampling techniques. Samples were collected from up to 14 depth intervals at each location using a 4-foot sampling screen. This HRSC approach identified a narrow (approx. 5 to 30 feet wide), approximately 3,000 square foot TCE DNAPL source area (maximum detected TCE concentration of 160,000 micrograms per liter [micro-g/L] at DPT sampling location DPT0225). Prior to implementation of a bioremediation interim measure, HRSC baseline sampling was conducted using DPT groundwater sampling techniques. Concentrations of TCE were an order of magnitude lower than previous reported (12,000 micro-g/L maximum at DPT sampling location DPT0225) at locations sampled adjacent to previous sampling locations. To further evaluate the variability in concentrations observed additional sampling was conducted in 2016. The results identified higher concentrations than originally detected within the previously defined source area and the presence of source zone concentrations upgradient of the previously defined source area (maximum concentration observed 570,000 micro-g/L). The HRSC baseline sampling data allowed for a revision of the bioremediation design prior to implementation. Bioremediation was implemented within the eastern portion of the source area in November and December 2016 and quarterly performance monitoring was completed in March and June 2017. Reductions in CVOC concentrations from baseline were observed at all performance monitoring wells in the treatment area, and by June 2017, an approximate 95% CVOC mass reduction was observed based on monitoring well sampling results. Results/Lessons Learned: The results of this project suggest that, due to the complexity of DNAPL source zones, HRSC during pre-implementation baseline sampling in the TCE source zone was an essential strategy for verifying the treatment area and depth prior to remedy implementation. If the upgradient source zone mass was not identified prior to bioremediation implementation, the mass would have served as a long-term source for the dissolved plume.

Chrest, Anne↗

Exploring NASA OMI Level 2 Data With Visualization

Satellite data products are important for a wide variety of applications that can bring far-reaching benefits to the science community and the broader society. These benefits can best be achieved if the satellite data are well utilized and interpreted, such as model inputs from satellite, or extreme events (such as volcano eruptions, dust storms,... etc.). Unfortunately, this is not always the case, despite the abundance and relative maturity of numerous satellite data products provided by NASA and other organizations. Such obstacles may be avoided by allowing users to visualize satellite data as "images", with accurate pixel-level (Level-2) information, including pixel coverage area delineation and science team recommended quality screening for individual geophysical parameters. We present a prototype service from the Goddard Earth Sciences Data and Information Services Center (GES DISC) supporting Aura OMI Level-2 Data with GIS-like capabilities. Functionality includes selecting data sources (e.g., multiple parameters under the same scene, like NO2 and SO2, or the same parameter with different aggregation methods, like NO2 in OMNO2G and OMNO2D products), user-defined area-of-interest and temporal extents, zooming, panning, overlaying, sliding, and data subsetting, reformatting, and reprojection. The system will allow any user-defined portal interface (front-end) to connect to our backend server with OGC standard-compliant Web Mapping Service (WMS) and Web Coverage Service (WCS) calls. This back-end service should greatly enhance its expandability to integrate additional outside data/map sources.

Aura↗

Exploring NASA OMI Level 2 Data With Visualization

Satellite data products are important for a wide variety of applications that can bring far-reaching benefits to the science community and the broader society. These benefits can best be achieved if the satellite data are well utilized and interpreted, such as model inputs from satellite, or extreme events (such as volcano eruptions, dust storms, etc.).Unfortunately, this is not always the case, despite the abundance and relative maturity of numerous satellite data products provided by NASA and other organizations. Such obstacles may be avoided by allowing users to visualize satellite data as images, with accurate pixel-level (Level-2) information, including pixel coverage area delineation and science team recommended quality screening for individual geophysical parameters. We present a prototype service from the Goddard Earth Sciences Data and Information Services Center (GES DISC) supporting Aura OMI Level-2 Data with GIS-like capabilities. Functionality includes selecting data sources (e.g., multiple parameters under the same scene, like NO2 and SO2, or the same parameter with different aggregation methods, like NO2 in OMNO2G and OMNO2D products), user-defined area-of-interest and temporal extents, zooming, panning, overlaying, sliding, and data subsetting, reformatting, and reprojection. The system will allow any user-defined portal interface (front-end) to connect to our backend server with OGC standard-compliant Web Mapping Service (WMS) and Web Coverage Service (WCS) calls. This back-end service should greatly enhance its expandability to integrate additional outside data-map sources.

Level 2↗

Development and Testing of Harpoon-Based Approaches for Collecting Comet Samples (Video Supplement)

This video supplement contains a set of videos created during the approximately 10-year-long course of developing and testing the Goddard Space Flight Center (GSFC) harpoon-based approach for collecting comet samples. The purpose of the videos is to illustrate various design concepts used in this method of acquiring samples of comet material, the testing used to verify the concepts, and the evolution of designs and testing. To play the videos this PDF needs to be opened in the freeware Adobe Reader. They do not seem to play while within a browser. While this supplement can be used as a stand-alone document, it is intended to augment its parent document of the same title, Development and Testing of Harpoon-Based Approaches for Collecting Comet Samples (NASA/CR-2017-219018; this document is accessible from the website: https://ssed.gsfc.nasa.gov/harpoon/SAS_Paper-V1.pdf). The parent document, which only contains text and figures, describes the overall development and testing effort and contains references to each of the videos in this supplement. Thus, the videos are primarily intended to augment the information provided by the text and figures in the parent document. This approach was followed to allow the file size of the parent document to remain small enough to facilitate downloading and storage. Some of the videos were created by other organizations, Johns Hopkins University Applied Physics Laboratory (JHU APL) and the German Aerospace Center called, the Deutsches Zentrum für Luft- und Raumfahrt (DLR), who are partnering with GSFC on developing this technology. Each video is accompanied by text that provides a summary description of its nature and purpose, as well as the identity of the authors. All videos have been edited to only show key parts of the testing. Although not all videos have sound, the sound has been retained in those that have it. Also, each video has been given one or more title screens to clarify what is going in different phases of the video.

Purves, Lloyd↗

Probabilistic Groundwater Modeling of the RDX Plume at Los Alamos National Laboratory to Support Risk Assessment - 20359

A plume of the contaminant hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) with concentrations greater than the New Mexico tap water drinking standard (9.66 ppb) is present in the regional aquifer near the southwestern boundary of Los Alamos National Laboratory (LANL). A risk assessment is performed for exposure to regional aquifer groundwater, with long-term predictions of RDX concentrations provided by a calibrated, probabilistic, numerical fate and transport model. The structure of the model is hierarchical, with the RDX Regional Aquifer (RA) groundwater model acting as the primary tool for analysis of downgradient RDX concentrations. The RA model is deeply informed by the conceptual site model (CSM) and is calibrated using site RDX concentration data and hydraulic head measurements, along with other analyses. The model is calibrated using data through December 2019. Where data are scarce other lines of evidence are used to inform inputs, including the multiphase RDX Vadose Zone (VZ) model and Pipe and Disk analytical screening tool. Model inputs are described with informative prior distributions using a robust approach to development that incorporates all available lines of evidence for every parameter used as an input to the RA model. Calibration is performed using a classical nonlinear optimization routine, which is then used to initialize a Bayesian calibration. The Bayesian calibration constrains the uncertainty in the classical calibration, ultimately providing posterior distributions for all model parameters. The challenges of the calibration include high-dimensional parameter space, including spatially heterogeneous hydraulic conductivities, comparatively sparse data, and low RDX concentrations. Posterior parameter distributions developed in the calibration process are then used for stochastic predictive model runs into the future. The result of the forward runs is spatially and temporally explicit estimates of head and concentration with uncertainty at all points in space and time. The probabilistic modeling approach presented here includes innovative computational and statistical methods that leverage high-performance computing (HPC) resources. It makes use of prior modeling work performed at the chromium plume site in the central LANL area, with extensive updates. The risk assessment will ultimately be used to support decision-making at the site, using multiple appropriately weighted sources of information, as well as uncertainty, sensitivity, and value-of-information analyses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Design of an 'Autonomous Medical Response Agent' Interface Prototype for Long Duration Spaceflight

Major challenges for astronauts in future long-duration exploration missions (LDEMs) will be that crewmembers are not expected to be medical professionals, may be under high workload and stress, are facing physiological challenges caused by spaceflight, and will have limited, delayed voice communications with medical support from Earth. An autonomous medical response agent (AMRA) is envisioned to help astronauts address medical complaints, develop a differential diagnosis, and guide self-treatment until a healthy state is restored. AMRA develops a process of personalized diagnosis and treatment through a Bayesian predictive control system that recommends therapeutic control actions including diagnostic tests and treatments to crewmembers (Menon, 2020). The Human Computer Interaction (HCI) lab from NASA Ames Research Center’s Human Systems Integration Division (Code TH) has collaborated with Nahlia Inc in human-centered design augmentation research for AMRA. The project, titled Design of ‘Autonomous Medical Response Agent Interface Prototype for Long Duration Spaceflight, has been funded by the Translational Research Institute for Space Health (TRISH) and introduces an interactive user-interface prototype that guides astronauts through self-diagnosis, treatment, and rehabilitation while communicating with remote specialists in ground support (most notably a patient’s flight surgeon). Our project develops the interaction design for the crewmember using AMRA through user research, iterative design, and usability testing to evaluate the user interface and workflow designed. The interface design deliverable for this project, titled AMRA Aggregate Information Display (AMRA AID) is an integrated information display system for comprehensive autonomous medical guidance, diagnosis, and treatment of in-flight medical conditions experienced by crewmembers. AMRA AID demonstrates how we might ensure crew autonomy, increase the crew’s medical capabilities, and decrease cognitive burden within a front-end user interface. AMRA AID refrains from relying on input from ground or mission control for self-treatment of medical issues—though ground awareness and communication with ground is maintained as a means of ensuring trust between mission control and crew. AMRA AID demonstrates how the crew’s on-board medical system might integrate with information from vehicle monitoring and crew schedule, without assuming causal relationships. AMRA AID’s comprehensive view enables efficient information access for both crew and ground support, reducing cognitive burden in the event of an unplanned or emergency medical incident and enabling informed analytical decisions to be made based on both crew and vehicle health. Human-centered design augmentation advanced within the prototype included: enhanced workflow and treatment guidance for two medical scenarios for a non-specialist user base with various levels of medical training, interaction design which considered speech (conversational user interface) elements and on-screen interactions to be developed in future iterations of the project, communication design and functional requirements relevant to self-care versus caring for another astronaut, as well as user testing of the prototype with an international space medical community. This project arrives at critical findings regarding usability needs, communication requirements, and integrated information requirements for a future technology interface functioning to increase confidence between ground support and LDEM crewmembers.

TRISH↗

Wilson Corners SWMU 001 2019-2020 Annual Long-Term Monitoring Report Kennedy Space Center, Florida

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2019 and 2020 at Wilson Corners, Solid Waste Management Unit 001, at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program. Adaptive site management is being utilized through ongoing assessment, design, and interim measures. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code. The goal of LTM at this site is threefold: to determine groundwater flow characteristics, monitor the downgradient concentration trends, and monitor select locations internal to the groundwater plume. Every 5 years, upgradient and side-gradient monitoring wells are sampled to verify delineation. The last time this was performed was in 2015. Sampling of these wells in 2020 was replaced with the direct push technology investigations in October 2020 and April 2021. The activities presented in this report include three field events: (1) December 2019 -groundwater gauging of 38 monitoring wells and sampling of 36 monitoring wells; (2) May 2020 - groundwater sampling of 7 monitoring wells; and (3) December 2020 - groundwater gauging of 49 monitoring wells and sampling of 43 monitoring wells. During the December 2019 and May 2020 events, monitoring wells were sampled using passive diffusion bags and were analyzed for a “full list” of volatile organic compounds (VOCs), including Freon 113. During the December 2020 event, the low flow sampling method was used, and samples were analyzed for a “select list” of VOCs, including Freon 113. The following conclusions can be made based on the 2019 and 2020 LTM results: •In December 2019 and December 2020, groundwater flow for the site was generally to the west with the individual zones only varying by occasional northerly and southerly components. This is generally consistent with historical observations at the site. •The GCTL plume continues to extend both horizontally and vertically beyond our current monitoring well network. •The vertical extent of VOCs was historically generally delineated by monitoring wells screened greater than 48 feet bls. The results from the two vertical extent monitoring wells WILC-MW0078 and WILC-MW0130 that were sampled during the 2019 and 2020 LTM indicate that groundwater VOC concentrations in both wells were greater than the GCTL. •Freon 113 was not detected above GCTLs during the 2019 and 2020 LTM events. Based on groundwater sampling activities performed during this reporting period, including recent DPT groundwater sampling conducted for the implementation of an air sparge system, the following recommendations are provided: •Install 10 new monitoring wells, which will be sampled along with 49 existing monitoring wells, to assist with delineation of the low concentration plume. The wells are listed inTable 4-1, and the proposed locations are presented on Figures4 -1 through 4-5. (Figures 4-1, 4-2, 4-3, and 4-5 also show updated plumes and proposed performance monitoring well locations. This information will be discussed and presented under a separate cover.) •Modify the annual LTM sampling plan as presented inTable 4-1. •Sampling for future events at the site will be conducted using low flow pumping methods. The next annual LTM sampling event is currently planned for December 2021. Please note the 10 new monitoring wells will not be installed before this event but will be installed as part of the upcoming IM construction and will be sampled during baseline sampling, along with the 49 existing monitoring wells. Following this sampling event, it is recommended that the Annual LTM be combined with the performance monitoring under the IM implementation, and LTM be temporarily discontinued. Objectives of the 2021 LTM are to: (i) evaluate groundwater gradient and flow direction by collecting depth to water measurements from LTM wells; (ii) continue monitoring the peripheral VOC trends in the northern, southern, and western portions of the site by monitoring existing wells and installing and monitoring new wells as recommended; and (iii) monitor select internal plume wells.

Jennifer Lynn Joyal↗

Electronic and Geometric Contributors to Hydrogen Binding in Uranium Oxide Grain Boundaries

Hydrogen induced corrosion of uranium, which leads to the formation of toxic and pyrophoric UH 3 , raises significant safety concerns for long-term storage of nuclear materials. Previous work suggests hydrogen diffuses through the grain boundaries (GBs) of the passivating oxide layer to initiate hydriding reactions. However, the atomistic mechanisms underlying this phenomenon and the structural factors that control its initiation are not well understood. To address this knowledge gap, here we use a high-throughput density functional theory (DFT) workflow to investigate the adsorption of H and H 2 in the defective bulk UO 2 . Specifically, we have exhaustively investigated the adsorption of H (107 sites) and H 2 (26 sites) in three different coincident site lattice (CSL) GBs: Σ3, Σ5, and Σ9. Compared to the binding energies in pristine UO 2 , we observe significantly stronger hydrogen adsorption at these GB sites. Interestingly, we find that the trends in H and H 2 adsorption vary considerably across the three GB models. In particular, while a small number of sites in Σ5 and Σ9 show exothermic adsorption of H and H 2 , respectively, no such sites are found in Σ3. These results provide fundamental atomistic insights that could guide the development of future corrosion mitigation strategies for the storage of nuclear materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molten Salt Lattice Confinement Fusion (LCF) Fast Fission Reactor for Lunar and Planetary Surface Power

Molten salt fission reactors (MSR) have been suggested for lunar and planetary surface power systems. They have the advantage of operating at high temperature, for efficient thermal-electrical conversion, low pressure, long-lived with high nuclear fuel burnup. MSR are often designed to breed fissile 233U from natural 232Th by neutron capture and  decay via: 232Th(n,)233Th(,)233Pa(,)233U Unfortunately, this process requires 233Pa isotope separation and segregation to decay to 233U. This requirement prevents additional neutron capture that interferes with 233U breeding. Instead, Wooley’s sub-critical, fast fission, molten salt reactor would use externally generated tokamak fusion neutrons1,2 to fission all actinides.We propose a simpler fusion-fast-fission sub-critical reactor that generates fast neutrons in situ from lattice confinement fusion (LCF) to fission fertile and fissile actinides. This hybrid reactor doesn't require enriched 235U fissile pins to initiate fis-sion reactions, nor 233Pa separation and segregation during operation. Like Wooley’s, this hybrid reactor “burns” natural uranium (238U) or thorium (232Th) which avoids uranium enrichment and additional fissile material launch safety and security costs. The LCF neutron source is initiated by bremsstrahlung photoneutrons (Fig. 1)3 or isotopic neutron sources in electron-screened lattices (Fig. 2)4,5. Alternatively, the electrolytic Pd-deuterium co-deposition6protocol fast fissions7 both 232Th and 238U. However, an aqueous electrolyte-based system, without pressurization similar to conventional pressurized water fission reactors, is incapable of high temperatures due to the boiling point of the electrolyte slightly over 100 C. Molten salts can be used instead as was demonstrated at the University of Hawaii8 using a variety of Ni and Pd cathodes in lithiated, hydrided and deuterated salts. These salts have melting points often exceeding 500C making them suitable to efficiently produce electrical power9 through either Advanced Stirling Genera-tors (< 100 kWe) or closed-Brayton Cycle (> 100 kWe). This hybrid reactor could power a wide range of lunar or Martian applications from unmanned in-struments, to charging vehicles and entire facilities such as human habitats or in situ resource utilization. The power conversion cycles are Carnot Cycle limited, but generally 30% efficient at best. However, waste heat on the moon or Mars is important to surviving either two-week lunar nights or Martian nights as well as providing process heat for mineral extraction and “living off the land”

Lawrence Forsley↗

Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump

Optical combs generated by a monolithic resonator with Kerrmedium can be used in a number of applications, including orbital clocks and frequency standards of extremely high accuracy, such as astronomy, molecular spectroscopy, and the like. The main difficulty of this approach is the relatively high pump power that has to be used in such devices, causing undesired thermorefractive effects, as well as stimulated Raman scattering, and limiting the optical comb quality and utility. In order to overcome this problem, this innovation uses a different approach to excitation of the nonlinear oscillations in a Kerr-nonlinear whispering gallery mode (WGM) resonator and generation of the optical comb. By coupling to the resonator two optical pump frequencies instead of just one, the efficiency of the comb source can be increased considerably. It therefore can operate in a lowerpower regime where the undesirable effects are not present. This process does not have a power threshold; therefore, the new optical component can easily be made strong enough to generate further components, making the optical comb spread in a cascade fashion. Additionally, the comb spacing can be made in an arbitrary number of the resonator free spectral ranges (FSR). The experimental setup for this innovation used a fluorite resonator with OMEGA= 13.56 GHz. This material has very low dispersion at the wavelength of 1.5 microns, so the resonator spectrum around this wavelength is highly equidistant. Light was coupled in and out of the resonator using two optical fibers polished at the optimal coupling angle. The gap between the resonator and the fibers, affecting the light coupling and the resonator loading, was controlled by piezo positioners. The light from the input fiber that did not go into the resonator reflected off of its rim, and was collected by a photodetector. This enabled observation and measurement of the (absorption) spectrum of the resonator. The input fiber combined light from two lasers centered at around 1,560 nanometers. Both laser frequencies were simultaneously scanned around the selected WGMs of the same family. However, they were separated by one, two, three, or ten FSRs. This was achieved by fine-tuning each laser frequency offset until the selected resonances overlap on the oscilloscope screen. The resonator quality factor Q = 7 x 10(exp 7) was relatively low to increase the linewidth and, therefore, the duty cycle of both lasers simultaneously coupled into their WGMs. The optical spectrum analyzer (OSA) connected to the output fiber was continuously acquiring data, asynchronously with the laser scan. The instrument was set to retain the peak power values; therefore, a trace recorded for a sufficiently long period of time reflected the situation with both lasers maximally coupled to the WGMs.

Strekalov, Dmitry V.↗

Harnessing Artificial Intelligence for Medical Diagnosis and Treatment During Space Exploration Missions

BACKGROUND The medical capabilities necessary for long-duration exploration missions (LDEMs) will differ tremendously from those currently available to crew medical officers (CMOs) on the International Space Station (ISS). Ground support will be more challenging due to distance-related communication delays and data transmission, and resource utilization must be optimized given limited ability for resupply. Clinical decision support systems (CDSSs) can help mitigate these limitations. The recent launch of generative artificial intelligence (AI) tools based upon large language models (LLM) support the creation of a smart assistant for onboard triage, diagnosis, and guided treatment of medical conditions during these missions. The Informing Mission Planning via Analysis of Complex Tradespaces (IMPACT) tool can help predict which clinical problems and outcomes are likely to occur for a design reference mission (DRM) and assist Medical Operations and systems engineering teams in creating a medical system that may optimally mitigate the predicted risks. The purpose of this study was to identify AI tools currently available or in development for the assistive diagnosis and care of medical conditions predicted for an extended duration Lunar mission. METHODS The 119 medical conditions currently built into the IMPACT suite were categorized into systems, and these diagnoses were used as keywords for our literature search. Using PubMed and Google Scholar, we performed a literature survey of AI tools applicable to these conditions. Article inclusion criteria included publication between the years 2017-2023, as the sentinel paper discussing the “selective attention” driving ChatGPT and other generative transformer models was published in June 2017. Where applicable, we reviewed only the top 1000 research articles (based on relevance) for each of the keywords/phrases. AI tools whose training sets were exclusive to a pediatric patient population were excluded. We also excluded any medical diagnostic tools (such as CT, MRI, mass spectrometry) or procedures (such as endoscopy, surgery) that are unlikely to be available during LDEMs due to mass and volume constraints, CMO knowledge, skills, and abilities, and/or inherent procedural risks. RESULTS Our survey highlighted several AI-driven tools for the triage, diagnosis, and management of those medical conditions highlighted by IMPACT. Selected publications for each medical condition were then screened for inclusion within ten systems-based categories including: general diagnostic tools (25), tools to diagnose and manage respiratory (40), dermatologic (34), neurologic (28), auditory and vestibular (30), ophthalmic (34), musculoskeletal (104), infection-associated (92), and gynecologic (19) conditions, as well as tools that could be deployed in the setting of trauma and emergency (34). CONCLUSIONS Numerous AI-driven tools were highlighted within this literature survey, ranging from chatbot assistants that triage knee pain to vision transformer models for diagnosis of ophthalmic conditions using ocular surface images captured with a mobile phone. Remaining challenges include optimizing connectivity and integration of existing and developing systems into the vehicles or habitats. Notably, findings from this survey could help guide the initial design of an all-encompassing, onboard medical AI assistant for use during future LDEMs.

R A Lacinski↗

Long-Term Health Risk Quantification

Astronauts face hazards during spaceflight, including space radiation exposure, isolation and confinement, traveling far distances from Earth, reduced gravity levels, and closed and hostile environments. These hazards drive the definition of human health and performance risks associated with spaceflight. NASA’s Human System Risk Board maintains the human spaceflight risk posture for in-mission risks, as well as post-flight, Long-Term Health (LTH)risks potentially occurring later in the astronaut’s life. LTH risk encompasses the timeframe from immediately post-flight, through the rest of an astronaut’s career, through retirement, and until death. Possible LTH risk outcomes include the time and interventions needed for the astronaut to return to preflight physiological states after experiencing spaceflight hazards and recovery from any in-mission medical events that persist into the post-flight timeframe. It includes chronic complications that may arise due to experiencing in-flight medical conditions or injuries and medical conditions that occur later in life with a higher probability of occurrence or with more severity because of their spaceflight exposure. Finally, LTH risk outcomes can also include a reduction in life expectancy due to spaceflight exposures. There have been 144 medical conditions identified by NASA’s Lifetime Surveillance of Astronaut Health team to be associated with LTH risk. Epidemiological studies have been performed for some of these conditions to determine if astronauts suffer from an increased prevalence or severity of the condition due to their spaceflight experience compared to a comparable cohort .Differences in astronaut mortality or morbidity due to spaceflight experience were not detected in several of these studies. There were two cases where a modest increase in the incidence rate of astronaut LTH outcomes was detected. The first suggested an increase in the incidence of melanoma cases in astronauts, where the number of cases in astronauts were similar to the elevated number of cases observed in airplane pilots. The second provided some evidence of elevated numbers of cardiovascular disease events in astronauts compared to an appropriate healthy comparator cohort, which may warrant additional investigation. The lack of detection of LTH risk outcomes should not ease concerns about astronaut LTH. The studies highlighted here constitute only a small portion of the potential LTH conditions that could occur. Once epidemiological studies are performed on all conditions, significant findings may be detected. The analysis of astronaut LTH also suffers from limited numbers of data points because of the limited numbers of astronauts overall and the even fewer who have reached an age where LTH outcomes may begin to manifest. As shuttle and ISS astronauts begin to age and increase the feasibility of analysis, LTH outcomes may be detected. An application of risk quantification is the use of risk metrics within trade studies for resource prioritization and decision making. Trade studies regarding countermeasures to LTH risk outcomes would benefit from a quantification of LTH risk. NASA has ground-based processes in place such as astronaut screening and access to continuous medical monitoring and care during and after their astronaut career which are the main methods for mitigating LTH risk. In-mission countermeasures, such as acceptable levels of medical care and available countermeasures to counter spaceflight related physiological decrements, can mitigate a poor health and performance status immediately post-flight. Identifying appropriate risk metrics, obtaining valid quantities for them, and tying them to LTH countermeasures are necessary steps for realizing their use in trade studies. This presentation will highlight the challenges associated with the identification, quantification, and utilization of LTH risk metrics

Beth Lewandowski↗

Development of a Technical, Economic, and Risk Assessment Tool for the Evaluation of Work Reduction Opportunities

Efficient and cost-effective operation of a nuclear power plant (NPP) is essential to ensuring long-term economical and safe operation. Multiple cost saving opportunities exist, referred to here as work reduction opportunities (WRO). These WROs reduce plant operating costs by employing various cost-effective strategies (e.g., implementation of modern technologies). Identifying and objectively screening WROs is an essential task to help reduce overall costs. However, there is no comprehensive framework for assessing WROs in the nuclear industry and evaluating their impact on plant operations. This report presents a novel framework for systematically evaluating WROs from a technical, economic, and risk perspective. As NPPs continue to add new technology and implement modernization strategies into their current processes, potential WROs are commonly identified. Although most WROs have the potential to reduce costs, not all opportunities will result in significant cost savings due to unforeseen risks, large implementation costs, or benefits that fall short of expectations. Examples of this can be the result of a technology that is not fully developed, uncertainty in the amount of cost reduction, or difficulties introducing a new process into an organization. These uncertainties can manifest several ways and can result in a WRO with limited cost savings or even a loss of investment. The framework developed emphasizes the importance of effectively screening the WROs from a holistic perspective to objectively identify inefficiencies and ensure a positive impact to the organization. This report presents the Technical, Economic, and Risk Assessment (TERA) as a key methodology for the screening and evaluation of potential WROs. The TERA framework begins with a screening phase where the process is examined through a hybrid combination of Lean Six Sigma and Integrated Operations for Nuclear (ION) guiding principles. This framework examines the current processes using the Lean Six Sigma SIPOC (Suppliers, Inputs, Process, Outputs, Consumers) methodology but retains the ION key elements of People, Technology, Process, and Governance as important factors to the nuclear decision-making process. By combining the principles of Lean Six Sigma and ION, the developed screening process is specific to the nuclear industry in that it systematically evaluates WROs in order to implement new technology that is comprehensively evaluated. The TERA begins by mapping current processes as they relate to WROs and examining the inefficiencies. Furthermore, the created process map can be used to identify and evaluate potential solutions. Using key performance indicators (KPIs), the TERA evaluates each area—technology, economics, and risk—for uncertainties and to perform cost-benefit analysis. The results of the TERA are important KPIs that allow for an evaluation of different processes and technology implementations. This assessment enables decision-makers to compare various WROs based on metrics and then make informed decisions for which opportunity to implement first. This research includes not only the creation of the TERA framework, but also the evaluation of its performance. A case study for screening potential WROs at Southern Nuclear Company is presented that utilizes the TERA methodology. Through the use of TERA, various WROs were screened, and the solutions evaluated for cost-benefit expectations. The report concludes by summarizing the overall effort and implications for utility modernization. The performance of the screening and TERA are discussed as well as the impact on the nuclear industry. The TERA process enables utilities to evaluate and inform investment decisions for WROs and mitigate any potential risks. Through this research, we provide utilities with a valuable framework to optimize operations, reduce costs, and drive continuous process improvement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Miniature Exercise Device-2 (MED-2): Preliminary ISS Evaluation Results for a Compact Motorized Resistive and Aerobic Rowing Exercise Device

Future human missions beyond Low Earth Orbit (LEO) will require onboard equipment to provide exercise capabilities for the crew to counter the adverse physiological effects of long-duration microgravity. To accomplish this within the physical constraints of a space vehicle or transit module, a single miniature device that provides both resistive and aerobic exercise modalities is required. To meet this need, Johnson Space Center’s (JSC) Software, Robotics, and Simulation Division (ER) developed the Miniature Exercise Device-2 (MED-2). MED-2 integrates a torque-controlled servomotor and a series-elastic actuator to provide highly-controllable load profiles and a large magnitude output performance in a very small package. This innovative technology is derived from years of JSC/ER design, development and operational experience with cutting-edge robotics, motor controllers, software and actuator/sensor miniaturization, including Robonaut 2 and MED-1. MED-2 was presented at the 2016 ISS R&D Conference. This is an update now that the last of six crewmembers will have completed planned MED-2 sessions on the International Space Station (ISS) in May 2018.Current state-of-the-art ISS exercise equipment consists of two treadmills, a resistive exercise device and two cycle ergometers with a total mass of several thousand pounds and a total volume of several cubic yards. This equipment has proven vital to mitigate the musculoskeletal and cardiovascular degradation effects of microgravity. However, due to the large operational volume and mass of these ISS devices, tailoring them for smaller vehicles, such as Orion, is not possible. In addition, each of the current ISS devices targets a single specific modality. Compared to the existing spaceflight (and even terrestrial) exercise equipment, MED-2 is a new archetype altogether. The combined features of compact size, multi-modality and high-performance is attributable to its innovative series elastic actuator and motor controller. Following its arrival on ISS in 2016, MED-2 was evaluated in two parts. The first and shorter evaluation was an engineering functional checkout of the hardware. As this was a novel exercise device previously never used on ISS, the initial checkout assessed the operation of the hardware and ensured the motion and dynamic range of the crew did not present any collision or other hazards. The second portion of the study collected the heart rates, kinematics and utilized operational volumes of six astronauts to determine the quality of both the resistive and aerobic exercise modalities as delivered by MED-2. Investigators from JSC Biomedical Research and Environmental Science Division (SK) and Glenn Research Center are currently evaluating the data and preparing preliminary results. For the resistive exercise modality, MED-2 demonstrated a range of constant resistive loads from 10-150 lbf. With a displacement range of 84 inches, the MED-2 accommodates users from 5th percentile Japanese female through 95th percentile American male for all of its certified exercises. The displacement measurement accuracy has also been verified within 2.5 percent full range. The crew was able to successfully perform all prescribed resistive exercises, except Goblet Squats which were not feasible with a constant load profile. For the aerobic exercise modality, MED-2 simulated a rowing motion with prescribed and user-selected resistance levels. It has demonstrated rates up to 60 strokes per minute on the ground. MED-2 loads and displacements performance are the same as those cited for the resistive modality. Although each of the crew was able to perform the prescribed aerobic rowing sets, there was considerable variability in the rowing motion among different crewmembers. Also, as expected, the crew was unable to get the full benefits of a typical terrestrial rowing stroke because the current configuration does not allow the user to reach past their feet. These observations have already informed the requirements for other microgravity rowing devices currently in development. One of the unique features of the MED-2 device is the intuitive touch-screen control system. This One Portal graphical user interface (GUI) was developed based on JSC/ER’s heritage knowledge and experience of developing and sustaining the current ISS exercise equipment. Through this interface, the crew easily performed prepared prescriptions as well as had the ability to adjust exercise modality, load and other exercise details such as number of repetitions and number of sets. This touch-screen and GUI fulfilled the MED-2 project goal to simplify the interaction between the user and the device. Furthermore, the extent to which MED-2 utilizes a touchscreen and GUI to control exercise equipment is unmatched among the existing ISS exercise devices. As a motorized device, MED-2 technology can provide a customizable force profile that can be varied as a function of strap displacement, strap velocity or a combination of these and other variables. During 2017, JSC/ER developed and flight-certified a resistive exercise algorithm that mimics the 1-G inertial effects of free-weights and enables adjustable eccentric-to-concentric loading ratios. Subsequent development will explore varying the load profiles and incorporating additional exercises beyond the current list of certified movements.

Exercise↗

Launch Complex 34, SWMU CC054 2023 DNAPL Source Zone Operations, Maintenance, and Monitoring, Site-Wide Long-Term Monitoring, and Hot Spot 6 Air Sparge System Annual Performance Monitoring and Phase Two Expansion Construction Completion Report Cape Canaveral Space Force Station, Florida

This Annual Performance Monitoring Report (PMR) for the Dense Non-Aqueous Phase Liquid (DNAPL) Source Zone (DSZ), Site-Wide Long-Term Monitoring (LTM), and Hot Spot 6 (HS 6) Air Sparge (AS) System presents the results of Year 14 operations and performance monitoring of the hydraulic containment (HC) Interim Measure (IM), details associated with construction and implementation of the HS 6 AS system expansion (Phase Two), and the results of operations and performance sampling of the HS 6 AS IM at Launch Complex 34 (LC34), located at Cape Canaveral Space Force Station (CCSFS), Florida. The timeframe for activities documented in this PMR extends from April 1, 2023 to March 31, 2024. LC34 has been designated Solid Waste Management Unit CC054 under the Kennedy Space Center (KSC) Resource Conservation and Recovery Act Corrective Action Program. The objective of the HC IM at LC34 is to contain the shallow and deep DSZ and surrounding dissolved-phase trichloroethene (TCE) high concentration plume via operation of a hydraulic containment system (HCS). The pre-IM design 300 micrograms per liter (μg/L) TCE groundwater contour was used to establish the deep zone capture area for deep recovery wells, and the shallow zone capture area was defined by the DSZ. The system began operating in 2010, and in 2015, the system was expanded to provide HC for areas within the 300 μg/L TCE groundwater isocontours of HS 3 and 4. In 2018 and 2019, an investigation was conducted to recharacterize the DSZ, which included investigating TCE mass in Layer 7. This data was subsequently used to optimize the pumping rates of the HCS and install additional recovery wells in Layer 7 to more adequately capture residual contaminant mass. The operational period for Year 14 of the HCS was from April 1, 2023 to March 31, 2024. Operational runtime for the system was 94 percent during Year 14, with downtime events attributed to planned maintenance, system repairs, and power outages. As of March 31, 2024, a total of 344,849,634 cumulative gallons of groundwater containing 94,656 pounds of chlorinated volatile organic compounds (CVOCs) have been removed by the HCS. During the reporting period covered under this report, the HCS recovered 31,176,393 gallons and approximately 6,319 pounds of CVOC mass. Total combined influent concentrations of TCE have decreased since startup from approximately 280,000 µg/L (January 2010) to 25,000 µg/L (March 2024). During the reporting period, all effluent concentrations from the HCS (aqueous and vapor) were below regulatory reporting limits, indicating the system continues to operate as intended. Performance monitoring was conducted in January 2024 within the DSZ to evaluate TCE contamination. Groundwater samples were collected via DPT at nine locations, consistent with previous events between 2017 and 2022. Full vertical profile sampling was completed at each DPT from 8 to 98 feet below land surface (bls), at 5-foot intervals. The DPT performance monitoring results are summarized in this PMR. The results revealed TCE remains at concentrations greater than 11,000 µg/L in the DSZ (1-percent solubility, indicative of DNAPL) at eight of the nine DPT locations and at depths ranging from 28 to 98 feet bls. An overall decreasing trend of TCE concentrations was observed in DPT samples during this reporting period, which is a reduction from the previous event (December 2022) and the peak event in December 2021, where TCE percentages appeared to increase in all depth zones because several recovery wells were turned off during the AS pilot study in the DSZ. The maximum TCE concentration in January 2024 was 1,600,000 µg/L in the 53 feet bls depth interval at DPT594 (previous maximum result in 2022 was 1,800,000 µg/L in the 48 feet bls depth interval at DPT599). This maximum concentration in the 53 feet bls depth interval is in the deep capture zone. During the January 2024 DPT event, the largest portion of TCE mass was observed in the 48 feet bls interval above/within Layer 4. This trend remains consistent with previous years and appears to indicate continued mass discharge from Layer 4 (fine-grained unit). In addition to DPT sampling, annual groundwater samples were collected from 11 deep monitoring wells in the DSZ area (Layers 7 and 8) in December 2023 to verify vertical and horizontal delineation. Three of the wells were also sampled biweekly to evaluate operations of recovery well RW21D (screened 86 to 106 feet bls), which was installed in January 2023. Of the Layer 7/8 monitoring sampled only annually, results were non-detect or less than groundwater cleanup target levels GCTLs in December 2023, with the exception of one well, IW45D2, which had a cis-1,2-dichloroethene (cDCE), detection greater than the GCTL. Of the three wells sampled biweekly during the operational period, the well located closest to Layer 7 recovery well RW21D (IW44D2, screened 105 to 115 feet bls) had concentrations of TCE, cDCE and vinyl chloride (VC) greater than GCTLs throughout the operational period, but displayed a decreasing trend since the peak concentrations in September 2023. The maximum TCE concentration during this operational period was 190,000 µg/L at IW44D2 in September 2023, but reduced to 700 µg/L in March 2024, indicating the HCS is still effectively removing mass from the source area. Expansion of the HCS and addition of new recovery wells is ongoing and will continue to be evaluated as the groundwater recovery scheme is optimized. Details of the expansion and optimization will be provided in a future PMR. The HS 6 AS IM was initiated in 2018 with 160 AS wells and expanded in 2019 with another 140 AS wells. An additional expansion of the HS 6 AS IM was completed during the reporting period covered under this report and details of the construction implementation and startup of the expansion are detailed in Section III of this report. The new expansion, referred to as Phase Two, was implemented between August 17, 2022 and August 28, 2023, and included the installation of 190 air sparge wells to treat an additional 11.2 acres. The original configuration (referred to as Phase One) operated until Phase Two came online, then all but 52 AS wells were turned off so the components could be moved and utilized in the Phase Two area. The 52 AS wells that remain on are in a barrier configuration preventing contaminated groundwater from impacting the treated area. The HS 6 AS system (both Phase One and Two) operated normally during the reporting period covered under this report. Semi-annual performance monitoring of the Phase One configuration was conducted in April and November 2023, consistent with previous years. For the Phase Two configuration, 21 new monitoring wells were installed and sampled quarterly, with a baseline event in July 2023, and quarterly events in November 2023 and February 2024 summarized in this report. Semi-annual monitoring results collected in April and October 2023 show concentrations of contaminants of concern (cDCE, trans-1,2-dichloroethene, and VC) have decreased to less than GCTLs in nearly all wells and not impacting the surface water drainage canal, indicating the HS 6 IM continues to meet objectives. The baseline and quarterly sampling for the Phase Two configuration indicate generally decreasing concentrations in wells within and around the perimeter of the treatment area. At least two more quarters of monitoring will be conducted and once those results are evaluated a reduced the sampling frequency may be considered. Overall, the tasks associated with Year 14 operation of the HC IM and operation of the HS 6 AS IM were performed in accordance with recommendations included in the previous 2022 LC34 (Year 13) PMR. Evaluation of results from the HC IM and HS 6 IM show that these systems are operating as designed and meeting performance objectives.

groundwater remediation↗

22” ADP Fan Rig Liners Design Report

A liner design study was conducted as part of a cooperative effort between five (5) government/industry teams that together seek to demonstrate the technology for designing and manufacturing acoustic liners that are twenty five percent (25%) more efficient than 1992 technology liners. The study emphasized teaming collaboration. The improved liners were designed by Pratt & Whitney and Boeing Airplane Company and built by Rohr Inc, and will be tested in the NASA/P& W 22-inch ADP fan rig at NASA Lewis Research Center's 9' x 15' wind tunnel. Design guidelines and decisions were made collectively during monthly design review telecons and at the formal final design review. The tools that were used to design the new improved liners were not new, but the process that was developed as part of this study that led into the evaluation and selection of the final and best liner designs is new. Until now, the liner design process as practiced by different industry teams varied greatly. Some procedures were based on empirical liner attenuation databases which could not adequately account for engine-to-engine hardwall fan noise spectral differences, while others were entirely theoretical. And regardless of which method one chose, the major difficulty was still the lack of understanding and knowledge of the actual hardwall fan source noise modal structure and farfield SPL spectra. The NASA-led effort to attempt actual measurements of the fan source noise modal structure by means of the rotating microphone array is expected to contribute significantly to the understanding of the nature of the fan tone noise modes, but the application to broadband noise is still a long way off. The new design process included consideration of the measured fan tone modes, but for the majority of the spectra a separate, systematic process was used. It is a common practice in the engine/nacelle industry that acoustic liners for new products are designed before actual measured hardwall engine far-field noise spectra are available. Target noise spectra are normally derived from existing engine noise databases with some adjustments to absolute SPLs and frequencies. This practice has been acceptable as long as the new engine was a derivative of the base engine. However, in the case of the ADP, the transition from a current engine base is too - great, and the adjustments could not adequately account for the quantum changes in SPL spectral differences. Examples were the 1992 single degree of freedom (SDOF) inlet and aft liners (designed by P&W) that would be used as the baseline liners against which the new improved liners' efficien¬cies would -be measured. As will be shown, these baseline liners have been found to be deeper than the desire optimum depths. The new liner design process begins with the selection of the target hard wall fan noise spectra. These spectra were obtained by scaling up (5.91 scale factor) the measured hardwall fan spectral data from the 22” ADP fan rig. Next, the modal energy contents for each 1/3-octave band center frequency of these hardwall fan noise spectra are estimated. (Within each 1/3-octave band center frequency, the model energy distribution approximation is for both tone and broadband noise). For the inlet noise, P&W uses a derivative of the NASA Lewis (Ed Rice's) method of classifying; and grouping propagating modes by their cutoff ratios. The next step is to assign energy level to each group of modes having the same cutoff ratio. In Ed Rice's model, the modes were grouped according to ten (10) cutoff ratio intervals with center values located at 1.026, 1.085, 1.155, 1.24, 1.35, 1.49, 1.69, 2.0, and 4.47 (with equal number of modes in each interval). The modes were assumed to have equal energy. P&W’s model expands the cutoff ratio-mode grouping into two hundred (200) smaller cutoff ratio intervals with center values located f1".'m 1.003 to 11.5 in 199 increasing incremental intervals. Next, P&W's model uses a "2-parameter" normal distribution as a template to assign energy levels to these 200 pre-determined cutoff ratio values (for each 1/3-octave band center frequency). In the past, P&W had conducted an extensive study to determine what "2-parameter" values are appropriate for fullscale inlet liners, and had developed a set of twenty-four (24) "2-pararneter" values (i.e. one for each 1/3-octave frequency band) that when used in Ed Rice's Inlet Attenuation Prediction Method produced predicted liner attenuations that closely matched measured liner attenuations from several P&W's engines. In the absence of actual measured tone and broadband modal data from the 22" ADP rig, the process will use P&W's proprietary set of "2-parameter" values for this liner design study. For the aft noise, Boeing uses a modal energy approximation that the "transport energy" of each propagating mode is equal. This approximation is almost the same as the equal energy per mode approximation, except for modes that are near cutoff. Boeing's model forces these modes to have lower energy levels. Both P&W and Boeing agreed that the "transport energy" approximation should work well for the ADP aft fan noise which appears to be dominated by broadband noise. The design process then proceeds to calculate the optimum liner impedances for each frequency in both the inlet and the aft. These optimum impedances represent the target impedances that the designed liners should have. Liners with impedances matching the optimum impedances at all frequencies are "ideal" liners. These ideal liners are theoretically the best liners. Unfortunately, it has been showed that it is impossible to design and build such ideal liners. The next best liners are ones that have impedances matching the optimum impedances over some frequency range (not all frequencies as for the ideal). This is accomplished by the use of "frequency weightings". Several of P&W's and Boeing's existing computer decks were used for optimizing and matching the designed liner impedances to the target optimum values (with the various frequency weightings specified). The optimization produces liner candidates with predicted liner impedances and descriptions of their physical liner characteristics. These candidate liner impedances are then used to predict their spectral attenuation characteristics which are then used together with the target hardwall fan noise spectra to determine the resulting treated noise spectra and PNLT values. Further optimization around the selected candidate designs yield final designs that are best in PNLT attenuations. Use of the optimization decks allowed a large number of liner candidates to be screened in a relatively short period of time. This design process is systematic and is efficient. The new inlet SDOF liner design obtained from the improved process was predicted to be 34% more effective (per unit area) than the 1992 baseline inlet liner. This inlet liner design is a 112 rayl wovenwiremesh facesheet over a 0.312-inch deep honeycomb core. The new aft SDOF liner design was predicted to be 52% more efficient than the aft baseline liner. The new aft SDOF liner is "segmented" with a shallower liner on the core cowl (inner duct wall) and a deeper liner on the fan cowl (outer duct wall). The shallower liner is a 70.6 rayl woven-wiremesh facesheet over a 0.141-inch deep honeycomb core. The deeper liner is a 68 rayl woven-wiremesh facesheet over a 0.309-inch deep honeycomb core. All liner dimensions are for the 22-inch model-scale ADP fan rig liners. The selected advanced liners are "segmented" double-layer (DDOF) liners for the inlet and aft locations. Also, for the inlet, a bulk liner with ceramic foam for wider broadband noise absorption was also selected. Triple-layer liner designs were not considered since the model scaled liners ( 1/5. 91) were dimensionally too small to be built correctly, and irrin earlier concept study, Boeing found a triple-layer to have only very small benefits over a double-layer. The inlet DDOF liner was predicted to be 83% more effective than the baseline. The inlet DDOF design is a 78 rayl facesheet over a 0.080 top cavity depth, a 68 rayl septum and a 0.227-inch bottom cavity depth. The inlet bulk liner is a 60 rayl facesheet over a 0.33-inch deep honeycomb filled with high temperature (HTP) ceramic foam with a density of 4.8 lb/cu.ft and a flow resistivity of 167 rayl/cm. The inlet bulk liner was predicted to be 83% more effective than the baseline liner. The aft DDOF liners are segmented with a shallower liner on the core cowl and a deeper liner on the fan cowl. The shallow DDOF liner is a 49.8 rayl facesheet over a 0.093-inch top cavity depth, a septum of 88.2 rayls over a 0.181-inch bottom cavity depth. The deep DDOF liner is a 12.9 rayl facesheet over a 0.140-inch top cavity depth, a septum of 53.1 ray ls over a 0.258-inch botom cavity depth. The segmented aft DDOF liners were predicted to be 86% more efficient than the baseline liner.

turbofan acoustic treatment↗