Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Summary Status of the Space Acceleration Measurement System (SAMS), September 1993

The Space Acceleration Measurement System (SAMS) was developed to measure the microgravity acceleration environment to which NASA science payloads are exposed during microgravity science missions on the shuttle. Six flight units have been fabricated to date. The inaugural flight of a SAMS unit was on STS-40 in June 1991 as part of the flrst Spacelab Life Sciences mission. Since that time, SAMS has flown on six additional missions and gathered 18 gigabytes of data representing 68 days of microgravity environment. The SAMS units have been flown in the shuttle middeck and cargo bay, in the Spacelab module, and in the Spacehab module. This paper summarizes the missions and experiments which SAMS has supported. The quantity of data and the utilization of the SAMS data is described. Future activities are briefly described for the SAMS project and.the Microgravity Measurement and Analysis Project (MMAP) to support science experiments and scientists with microgravity environment measurement and analysis.

DeLombard, Richard↗

Compact Simultaneous-beam Optical Strain Measurement System, Phase 5

Recent advances on the laser speckle strain measurement system under development at NASA Lewis Research Center have resulted in a compact, easy-to-use measurement package having many performance improvements over previous systems. NASA has developed this high performance optical strain measurement system for high temperature material testing applications. The system is based on I. Yamaguchi's two-beam speckle-shift strain measurement theory, and uses a new optical design that allows simultaneous recording of laser speckle patterns. This design greatly improves system response over previous implementations of the two-beam speckle-shift technique. The degree of immunity to transient rigid body motions is no longer dependent on the data transfer rate. The system automatically calculates surface strains at a frequency of about 5 Hz using a high speed digital signal processor in a personal computer. This system is fully automated, and can be operated remotely. This report describes the designs and methods used by the system, and shows low temperature strain test results obtained from small diameter tungsten-rhenium and palladium-chrome wires.

Lant, Christian T.↗

Development of Field Measurement Systems for Flight Vehicle Noise

Field measurement of noise radiated from flight vehicles is an important element of aircraft noise research programs. At NASA Langley, a dedicated effort that spans over two decades was devoted to the development of acoustic measurement systems to support the NASA noise research programs. The new challenge for vehicle operational noise reduction through varying glide slope and flight path require noise measurement to be made over a very large area under the vehicle flight path. Such a challenge can be met through the digital remote system currently under final development at NASA Langley.

Yu, James C.↗

Progress in optical strain measurement system development

A laser speckle strain measurement system has been built and tested for the NASA Lewis Research Center. The system is based on a speckle shift technique, which automatically corrects for error due to rigid body motion, and provides a near real time measure of strain. The first stage of a multiphase effort to develop an optical strain gauge capable of mapping in two dimensions the strain on the surface of a hot specimen is discussed. The objectives of this first phase have been to provide a noncontact, one-dimensional, differential strain gauge for experimental purposes, and to determine the maximum open air temperature limit of the system.

Lant, Christian T.↗

Whole body measurement systems

A system for measuring the volume and volume variations of a human body under zero gravity conditions is disclosed. An enclosed chamber having a defined volume and arranged for receiving a human body is provided with means for infrasonically varying the volume of the chamber. The changes in volume produce resultant changes in pressure, and under substantially isentropic conditions, an isentropic relationship permits a determination of gas volume which, in turn, when related to total chamber volume permits a determination of the body volume. By comparison techniques, volume changes of a human independent of gravity conditions can be determined.

Ogle, J. S.↗

Flight assessment of an atmospheric turbulence measurement system with emphasis on long wavelengths

A flight assessment has been made of a system for measuring the three components of atmospheric turbulence in the frequency range associated with airplane motions (0 to approximately 0.5 Hz). Results of the assessment indicate acceptable accuracy of the resulting time histories and power spectra. Small residual errors at the airplane short period and Dutch roll frequencies (0.5 and 0.25 Hz, respectively), as determined from in-flight maneuvers in smooth air, would not be detectable on the power spectra. However, errors at approximately 0.25 Hz can be present in the time history of the lateral turbulence component, particularly at the higher altitudes where airplane yawing motions are large. An assessment of the quantities comprising the vertical turbulence component leads to the conclusion that the vertical component is essentially accurate to zero frequency.

Rhyne, R. H.↗

Wear Measurement System

Lewis Research Center developed a tribometer for in-house wear tests. Implant Sciences Corporation (ISC), working on a NASA contract to develop coatings to enhance the wear capabilities of materials, adapted the tribometer for its own use and developed a commercial line of user-friendly systems. The ISC-200 is a pin-on-disk type of tribometer, functioning like a record player and creating a wear groove on the disk, with variables of speed and load. The system can measure the coefficient of friction, the wear behavior between materials, and the integrity of thin films or coatings. Applications include measuring wear on contact lenses and engine parts and testing disk drives.

Source record↗

Development of the Volatile Monitoring Oxygen Measurement System

Extracting resources from the Lunar Regolith for oxygen production is a primary focus for the NASA in-situ resource utilization technology developments for the Artemis missions. The need to identify, separate, and purify extracted resources continuously evolves around state-of-the-art technology research and development and will also enable more sustainable space human exploration. A research team at NASA’s Kennedy Space Center comprised of the Applied Chemistry Laboratory and the Granular Mechanics and Regolith Operations Laboratory have developed a versatile system able to focus on the extraction and quantification of oxygen. The system, Volatile Monitoring Oxygen Measurement System (VMOMS), can identify extracted oxygen from regolith processing technologies such as molten regolith electrolysis. The technology can quantify oxygen levels from a few parts per million, ppm, up to a 95% oxygen environment and detect other volatiles.

D. E. Essumang↗

Radar Waveform Pulse Analysis Measurement System for High-Power GaN Amplifiers

This work presents a measurement system to characterize the pulsed response of high-power GaN amplifiers for use in space-based SAR platforms that require very strict amplitude and phase stability. The measurement system is able to record and analyze data on three different time scales: fast, slow, and long, which allows for greater detail of the mechanisms that impact amplitude and phase stability. The system is fully automated through MATLAB, which offers both instrument control capability and in-situ data processing. To validate this system, a high-power GaN HEMT amplifier operated in saturation was characterized. The fast time results show that variations to the amplitude and phase are correlated to DC supply transients, while long time characteristics are correlated to temperature changes.

high-power amplifier (HPA)↗

High Temperature Emissivity Measurement System (HiTEMS)

The High Temperature Emissivity Measurement System (HiTEMS) is a ground test capability at NASA Marshall Space Flight Center enabling near normal and varied incident angle spectral and total emittance measurements. This data is gathered at vacuum levels as low as approximately 10-7 Torr within a temperature range of 600°C to approximately 2,600°C, providing essential material property data to assist with improved thermal control estimates for spacecraft hardware. Recent work focusing on the measurement of smooth and bead blasted tungsten samples in support of the Propulsion Research and Tech Branch at NASA MSFC provides a thorough examination into HiTEMS capabilities and insight into the variabilities related to sample roughness at extreme temperatures.

Meghan Carrico↗

A case study: Eliminating nuisance within-part variation in assessing a measurement system

In this work, we consider a gauge R & R study in which a part measured in production is randomly placed in the measuring device. In assessing a measurement system, one does not want a possible within-part variation included in the estimated gauge variation and we propose a way to eliminate it. We consider a pellet measurement system and demonstrate the benefits of eliminating within-part variation in its assessment.

42 ENGINEERING↗

Three-dimensional wire-mesh capacitor system measures fluid density

Gaging system automatically measures the bulk density of a stored, electrically nonconductive fluid containing varying portions of liquid and vapor. The system employs a three-dimensional wire-mesh capacitor whose capacitance varies with the bulk density of the fluid dielectric medium between the capacitor plates.

Source record↗

Further development of the dynamic gas temperature measurement system

The objective of this effort was to experimentally verify a dynamic gas temperature measurement system in laboratory experiments. The dynamic gas temperature measurement system verification program is described. A brief description of the sensor geometry and construction is followed by a discussion of the probe heat transfer analysis and subsequent compensation method. The laboratory experiments are described and experimental results are discussed. Finally, directions for further investigation are given.

Elmore, D. L.↗

A performance measurement system for engineering services

A performance measurement system which provides both a means of monitoring performance and a resource to support management decision making is described. The process of performance indicator development is discussed and typical indicators are described. The paper concludes with a summary of some of the lessons learned in applying productivity measurements to engineering services tasks and in automating data collection, evaluation and interpretation.

West, R. L.↗

Electro-optical spin measurement system

An electro-optical spin measurement system for a spin model in a spin tunnel includes a radio controlled receiver/transmitter, targets located on the spin model, optical receivers mounted around the perimeter of the spin tunnel and the base of the spin tunnel for receiving data from the targets, and a control system for accumulating data from the radio controlled receiver and receivers. Six targets are employed. The spin model includes a fuselage, wings, nose, and tail. Two targets are located under the fuselage of the spin model at the nose tip and tail. Two targets are located on the side of the fuselage at the nose tip and tail, and a target is located under each wing tip. The targets under the fuselage at the nose tip and tail measure spin rate of the spin model, targets on the side of the fuselage at the nose tip and tail measure angle of attack of the spin model, and the targets under the wing tips measure roll angle of the spin model. Optical receivers are mounted at 90 degree increments around the periphery of the spin tunnel to determine angle of attack and roll angle measurements of the spin model. Optical receivers are also mounted at the base of the spin tunnel to define quadrant and position of the spin model and to determine the spin rate of the spin model.

Fodale, Robert↗