Search NASA⌕ Search

SEARCH · Search NASA

Results for “metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Swept-Lookback Deflectometry for High Performance Concentrating Solar Power Optical Metrology

This report describes an initial investigation into a proposed solution to the important problem of performing a detailed evaluation of heliostat optical performance, in situ in a heliostat field. Our approach is to place digital cameras in a position near the receiver where they look back toward the heliostat mirrors. The pixels of each camera sensor identify a set of small cells on the mirror surface, each corresponding to a “mixel.” By either passing reflected sunbeam over the camera or passing the camera through the reflected sunbeam, the cameras intercept sunlight reflected from each mixel. We then analyze the recorded video data to determine times when each mixel transitions from dark to light, and then back to dark. We then use these transitions to construct vectors from the camera to the mixel, and then from the mixel to the edge of the Sun at that moment. We then compute the surface normal at the mixel, which bisects the angle between these vectors. Performing this analysis for all mixels in the mirror yields a high-resolution map of slope across the mirror surface. We have implemented most of this process, successfully collecting data for an example heliostat facet and computing a preliminary estimated slope map. However, more work remains to complete this calculation, since certain factors and transformations are not yet included. Our observations so far support our hypothesis that such a system is possible, but we have not yet completed our quantitative evaluation of the concept.

14 SOLAR ENERGY↗

Pushing the Boundaries of Coherence in Superconducting Quantum Systems at the SQMS Center for Computing, Sensing, and Metrology

This talk will highlight recent advances at the SQMS Center in understanding and mitigating decoherence in superconducting quantum systems, focusing on both transmon qubits and 3D superconducting cavities. I will present results from systematic studies of materials and devices, aimed at identifying key sources of loss: including two-level systems (TLS), quasiparticles, and other noise mechanisms. These studies span microwave loss characterization in materials such as niobium, tantalum, aluminum, and their native oxides, as well as substrate losses in silicon and sapphire. Using both qubits and cavities, we disentangle subsystem contributions to loss and develop a hierarchy of mitigation strategies. Through these efforts, we have achieved transmon coherence times exceeding one millisecond. I will also present investigations into quasiparticle dynamics, including bursts observed in qubits located above ground and in the Gran Sasso underground laboratory. Additional studies explore temperature dependence to distinguish between TLS and quasiparticle losses, and reveal that applying a magnetic field can reduce temporal T1 fluctuations in transmons. Building on these results, we demonstrate a record-coherence two-cell cavity-qudit system with coherence times exceeding 20 milliseconds. By leveraging sideband interactions and error-resilient protocols including measurement-based correction and post-selection, we achieve high-fidelity quantum state control. This includes preparation of Fock states up to N = 20 with fidelities over 95%, and two-mode entanglement with coherence-limited fidelities reaching 99.9% after post-selection. These achievements position the SQMS platform as a powerful foundation for scalable quantum information processing and high-dimensional qudit encodings. Finally, I will discuss how these ultra-coherent systems are being deployed in emerging quantum sensing applications, including dark matter searches and gravitational wave detection.

Roy, Tanay [Fermilab]↗

Machine Tool Metrology in support of carbide insert production

In the context of lab modernization, careful consideration must be given to existing technologies, processes, and knowledge to support the ongoing production, maintenance, and improvement of products for the nuclear enterprise. This consideration often involves analyzing manufacturing processes both to pursue modernization or automation and to ensure the ability to maintain manufacturing capability.

42 ENGINEERING↗

THERMAL/STRUCTURAL ANALYSIS OF THE AXION QUANTUM METROLOGY CAVITY AND ITS COMPONENTS

This research was centered around maximizing the capability to cool dielectric material within a containment unit, or Photonic Band Gap (PBG) cavity, designed for detecting axion dark matter and identifying the unit’s thermal properties. There are multiple types of PBG cavities, but the latest version that axion researchers wish to use has been theorized to contain possible issues related to its thermal properties. Thermal conductivity is an issue with the dielectric material because it is made from alumina which is highly insulative. This is important since the research is being done in a cryogenic environment and the thermal noise affects the quantum bit used for detecting the axion to photon conversion process. Therefore, any improvements to this unit should be justified and implemented but are not entirely limited to thermal contact related aspects of PBG cavities. A prospect of using sapphire in place of alumina also exists, but this is a more expensive, less tested, and more elusive material to justify the creation of a full dielectric structure out of sapphire. Thermal aspects of the cavity were analyzed using finite element method (FEM) and an experiment designed to test different thermal joint materials. FEM was used to check the contraction of the cavity during cooling, the contact quality between the dielectric material and cavity wall, theheat flow rate through the assembly, and helps visualize the cavity’s reaction to different design changes. A simple comparison between thermal conductivity curves justified the usage of sapphire over alumina from a thermal property point of view. Thus, the method of experimentation had an additional dielectric material, sapphire, to test with and compare to alumina. The thermal test identified which material is best to use for a thermal joint but also simultaneously found the conductance of the joint and dielectric material as well as an estimate for what the temperature is inside the larger scale cavity since a thermometer cannot be placed inside the PBG when it cools. Initially, the cavity simulation was tested for structural deformation properties and stress distribution since it is made of copper which contracts heavily in comparison to most other materials. The reduction in volume of the cavity was less than anticipated which gave more room for a possible usage of a modified thermal joint for additional contact area and higher conductivity.

43 PARTICLE ACCELERATORS↗