Laser-Assisted Analysis of Aerosol Particles

Proposed instrument makes rapid mass-spectrometric analyses of individual particles in aerosols. Each particle vaporized and ionized by intense laser pulse, which creates ions of minimum complexity. Ability to analyze single aerosol particles continuously makes technique suitable for detection of toxic aerosol particles on real-time basis and for identification of their sources.

Sinha, M. P.↗

Space experiments with particle accelerators (SEPAC): Description of instrumentation

SEPAC (Space Experiments with Particle Accelerators) flew on Spacelab 1 (SL 1) in November and December 1983. SEPAC is a joint U.S.-Japan investigation of the interaction of electron, plasma, and neutral beams with the ionosphere, atmosphere and magnetosphere. It is scheduled to fly again on Atlas 1 in August 1990. On SL 1, SEPAC used an electron accelerator, a plasma accelerator, and neutral gas source as active elements and an array of diagnostics to investigate the interactions. For Atlas 1, the plasma accelerator will be replaced by a plasma contactor and charge collection devices to improve vehicle charging meutralization. This paper describes the SEPAC instrumentation in detail for the SL 1 and Atlas 1 flights and includes a bibliography of SEPAC papers.

Taylor, W. W. L.↗

ARM Data for Examining the Ice-Nucleating Particles from SGP Part II (ExINP-SGP II) Aerodynamic Particle Sizer, Condensation Particle Counter, and Meteorological Instrument Data Analysis

Knowledge of airborne particulate matter (PM), especially the particles that have supermicron diameters, is key for understanding ice-nucleating particles (INPs). Supported by the Atmospheric Radiation Measurement (ARM) user facility, we sampled PM and surface soil materials at the Southern Great Plains observatory (SGP; 36° 36′ 18″ N, 97° 29′ 6″ W) to systematically compare the INP abundance and ice nucleation efficiency of different SGP samples (i.e., airborne versus surface materials). The field campaign, named Examing INP from SGP II (ExINP-SGP II), was conducted from 20 January to 20 April, 2021. Our data analysis products include (1) physical surface sorption characterization data (i.e., BET, pore volume) of two sets of samples -- SGP Soil and USDA, (2) X-ray diffraction spectra for the same two samples, (3) immersion freezing assay-based ice nucleation active mass density data as a function of freezing temperature for both ambient and surface samples, and (4) time-series data of ambient meteorological conditions, concentration particle counter-derived aerosol particle concentration, and aerosol particle sizer measurement during ExINP-SGP II.

54 ENVIRONMENTAL SCIENCES↗

Aerosol emissions from water-lean solvents for post-combustion CO 2 capture

Advanced water-lean solvents (WLS) for post-combustion CO 2 capture have been gaining interest due to their ability to reduce the parasitic penalty from energy needed for solvent regeneration. Commercial implementation of these novel CO 2 capture technologies hinges on successful control of amine emissions. RTI conducted a parametric study of fundamental and operational variables influence on overall amine aerosol and vapor emissions from our water-lean solvent eCO 2 Sol™ using our 6-kW equivalent bench-scale gas absorption system. The parametric testing used a simulated flue gas with 15 % CO 2 , 2.3–4.2 % H 2 O, and 0–6 ppm sulfite (SO 3 ) to examine the impact of the presence of aerosols to the capture performance and amine emissions from the system. The SO 3 reacts with water in the flue gas to create H 2 SO 4 , which forms liquid aerosol droplets and provide nucleation sites for growth of aerosols. Scanning Mobility Particle Sizer and Aerodynamic Particle Sizer instruments monitored the aerosol particle size distribution. Parametric testing results suggested that the presence of the aerosols in the flue gas could increase the overall amine emissions by 10X compared to the baseline emissions from WLS’s vapor pressure. Principal component analysis (PCA) and projection to latent squares (PLS) developed models to predict the aerosol-based amine emissions from process data. The predictive PLS model had a correlation coefficient (Q 2 ) of 0.92 and could predict the aerosol-based emissions from the NAS process with ±15 % accuracy (average absolute deviation, AAD). The PLS regression model also identified key variables affecting aerosol-based emissions from WLS.

42 ENGINEERING↗

The MERiT Onboard the CeREs: A Novel Instrument to Study Energetic Particles in the Earth's Radiation Belts

The Miniaturized Electron pRoton Telescope, MERiT, is a low‐mass, low‐power, compact instrument using an innovative combination of particle detectors, sensor electronics, and onboard processing. MERiT is flying on the Compact Radiation belt Explorer, CeREs, a 3U CubeSat launched into a low earth orbit of 500‐km altitude and inclination of 85° on 16 December 2018. The primary and secondary science goals of CeREs are to investigate electron microbursts and to study solar particles. MERiT comprises a stack of solid state detectors (SSD) behind space facing avalanche photo diodes (APDs) surrounded by W‐Al shielding to reduce side‐penetrating particle background. The APD‐SSD combination enables measurement of electrons from 5 to 200 keV and 1 to 8 MeV; protons from 200–400 keV and 7–100 MeV in differential channels with energy resolution ΔE/E≈30% for both electrons and protons. MERiT measures microbursts with a high time resolution ranging from 4 to 16 ms and solar particles with a cadence of 1 s. MERiT energy channels and cadences are software configurable via algorithms and lookup tables residing on a field‐programmable gate array. The lookup tables can be changed via ground commands. MERiT geometry factor is 31 sq.cm‐sr and optimized to measure microbursts with the instrument viewing the local zenith in orbit. MERiT enables investigation of dynamical processes of radiation belt electron energization and loss, solar electron and proton transport, and their access to the Earth's polar caps. We describe the MERiT sensor design, calibration, operational modes, data products, and science goals.

Kanekal, S. G.↗

The Auroral Particles experiment

An instrument for the detection of particles in the energy range of 0.1 ev to 80 Kev was designed, built, tested, calibrated, and flown onboard the spacecraft ATS-6. Data from this instrument generated the following research: intensive studies of the plasma in the vicinity of the spacecraft; global variations of plasmas; correlative studies using either other spacecraft or ground based measurements; and studies of spacecraft interactions with ambient plasmas including charging, local electric fields due to differential charging, and active control of spacecraft potential. Results from this research are presented.

Source record↗

Surgical Borescopes Remove Contaminants

Borescope instruments put to use in extracting hard-to-reach particles. Surgical instruments in flexible borescopes used for removing contaminant particles from normally inaccessible places within equipment. Instruments readily enter small openings, turn corners, and reach far.

Vallow, K.↗

Phase A conceptual design study of the Atmospheric, Magnetospheric and Plasmas in Space (AMPS) payload

The 12 month Phase A Conceptual Design Study of the Atmospheric, Magnetospheric and Plasmas in Space (AMPS) payload performed within the Program Development Directorate of the Marshall Space Flight Center is presented. The AMPS payload makes use of the Spacelab pressurized module and pallet, is launched by the space shuttle, and will have initial flight durations of 7 days. Scientific instruments including particle accelerators, high power transmitters, optical instruments, and chemical release devices are mounted externally on the Spacelab pallet and are controlled by the experimenters from within the pressurized module. The capability of real-time scientist interaction on-orbit with the experiment is a major characteristic of AMPS.

Source record↗

Performance comparison of Malvern instruments laser diffraction drop size analyzer

The performance of ten laser diffraction particle sizing instruments (Malvern models 2200 and 2600) has been evaluated using a synthetic particle size reference standard in a round-robin test at nine independent laboratories. A calibration reticle consisting of a two-dimensional array of opaque, circular particle images photoetched in chrome thin film deposited on a glass substrate was used as the reference. Mean diameters (e.g., D32) for the reticle measured by the ten unmodified instruments varied by 27 percent. In contrast, data from six instruments with individually calibrated photodetector correction factors demonstrated much better agreement and were within 2.6 percent of the actual reticle properties.

Hirleman, E. D.↗

Modular Architecture for the Measurement of Space Radiation

A modular architecture has been conceived for the design of radiation-monitoring instruments used aboard spacecraft and in planetary-exploration settings. This architecture reflects lessons learned from experience with prior radiation-monitoring instruments. A prototype instrument that embodies the architecture has been developed as part of the Mars Advanced Radiation Acquisition (MARA) project. The architecture is also applicable on Earth for radiation-monitoring instruments in research of energetic electrically charged particles and instruments monitoring radiation for purposes of safety, military defense, and detection of hidden nuclear devices and materials.

Delaune, Paul↗

Particle Seeding Method for Small-Scale, High-Pressure Nozzles

NASA tests new launch and reentry vehicle configurations in wind tunnels, where flow visualizations and quantitative flowfield measurements are often desired. Some of these vehicles have rocket motors for propulsion, retro-propulsion, or reaction control. High-pressure air is used to supply these rocket motor plumes. However, it is difficult to make off-body measurements in these regions, for several reasons. First, the plumes themselves lack seeding particles for flow diagnostics, and at the low pressures after expansion, Rayleigh scattering or other molecular techniques yield insufficient signal for flow velocity measurements. Second, the plumes displace particle-seeded tunnel air, preventing measurements in the vicinity of the plume. Third, the plumes force shock waves ahead of the vehicle, which melts the ice crystal fog commonly used for visualization and measurement techniques in certain facilities. In the current work, a novel method for seeding the flow in these small-scale, high-pressure nozzles has been devised and initially demonstrated, potentially enabling quantitative and qualitative measurements with particle-based instruments such as Doppler global velocimetry or particle image velocimetry. The method involves a Venturi contraction to draw the seed liquid out of a reservoir and into the nozzle channel, wherein shearing forces atomize the seed into particles. The concept was tested with a laser sheet visualization, which demonstrated that the flow rate of liquid spray was controllable; a valve could be adjusted to drop the flow rate by up to 65%. This relatively inexpensive and simple technique may prove useful in wind tunnel experiments involving particle-based laser diagnostics and small, high-pressure nozzles.

Aditya S. Acharya↗

Particle Seeding Method for Small-Scale, High-Pressure Nozzles

NASA tests new launch and reentry vehicle configurations in wind tunnels, where flow visualizations and quantitative flowfield measurements are often desired. Some of these vehicles have rocket motors for propulsion, retro-propulsion, or reaction control. High-pressure air is used to supply these rocket motor plumes. However, it is difficult to make off-body measurements in these regions, for several reasons. First, the plumes themselves lack seeding particles for flow diagnostics, and at the low pressures after expansion, Rayleigh scattering or other molecular techniques yield insufficient signal for flow velocity measurements. Second, the plumes displace particle-seeded tunnel air, preventing measurements in the vicinity of the plume. Third, the plumes force shock waves ahead of the vehicle, which melts the ice crystal fog commonly used for visualization and measurement techniques in certain facilities. In the current work, a novel method for seeding the flow in these small-scale, high-pressure nozzles has been devised and initially demonstrated, potentially enabling quantitative and qualitative measurements with particle-based instruments such as Doppler global velocimetry or particle image velocimetry. The method involves a Venturi contraction to draw the seed liquid out of a reservoir and into the nozzle channel, wherein shearing forces atomize the seed into particles. The concept was tested with a laser sheet visualization, which demonstrated that the flow rate of liquid spray was controllable; a valve could be adjusted to drop the flow rate by up to 65%. This relatively inexpensive and simple technique may prove useful in wind tunnel experiments involving particle-based laser diagnostics and small, high-pressure nozzles.

lasers↗

Coherent optical instrumentation for measurements of particle parameters

The application of cross-beam Laser Doppler Velocimeter (LDV) for sizing small particles was investigated from September 1973 to August 1974. Theoretical results were obtained by analyzing the scattering characteristics of small particles in a cross-beam LDV system. Theoretical calculations based on scalar diffraction theory and Mie scattering theory were performed. Experimental results were also obtained to compare with theoretical predictions. It is concluded that the forward scattering characteristics of small particles in a cross-beam LDV system can be used for particle sizing.

Chu, W. P.↗

Effects of non-spherical drops on a phase Doppler spray analyzer

A phase/Doppler spray analyzer (P/DSA) and a laser imaging system was used to study the response of a P/DSA to nonspherical particles. Methanol particles with an aspect ratio ranging from 0.7 to 1.4 were used in this investigation. Results indicated that the P/DSA was quite sensitive to particle shape. A Berglund-Liu generator was used to produce particles of 98 microns (volumetric diameter). The P/DSA instrument measured particle sizes ranging from 142 microns for a particle of aspect ratio 0.7, to 84 microns for an aspect ratio of 1.4. Particle diameters based on averaged x and y diameters for the laser imaging system ranged from 95 microns to 92 microns over the same range of aspect ratios.

Alexander, D. R.↗