Search NASA⌕ Search

SEARCH · Search NASA

Results for “payback”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing energy efficiency in wastewater treatment plants: A data-driven approach for waste heat recovery and an economic analysis using Organic Rankine Cycle and thermal energy storage

Maximizing energy efficiency through waste heat recovery (WHR) processes is crucial for sustainable and ecofriendly operations across multiple industries, notably in wastewater treatment plants (WWTPs). This work proposes a comprehensive approach for assessing the WHR feasibility in WWTPs, structured in two main objectives. Firstly, an Artificial Neural Network (ANN) model is developed to accurately predict WHR based on operational data, including biogas temperature, biogas pressure, daily production in kWh, and WHR values in kWh th . The second objective focuses on economically evaluating the WHR feasibility based on the estimated WHR values obtained by the ANN model, and then realistically assessing the economic feasibility of integrating the Organic Rankine Cycle (ORC) and Seasonal Thermal Energy Storage (STES) systems. With an application to the As-Samra WWTP located in Jordan, the developed ANN model demonstrates promising results in the validation phase, with a root mean square error (RMSE) of 2206 kWh/day, a mean absolute error (MAE) of 1674 kWh/day, and an R-squared (R 2 ) value of 68%. On the other hand, the economic analysis reveals that an optimal ORC system of 412.14 kW e capacity yields a Net Present Value (NPV) of 2.09 million US dollars, a Levelized Cost of Energy (LCOE) of 0.0749 USD/kWh, a Payback Period (PBP) of 4.8 years, and annual revenues of 428 kUSD. This work also investigates the techno-economic feasibility of integrating ORC-STES. Results indicate that the LCOE and PBP are highly affected by the ORC's capital cost, and integrating STES increases the LCOE to 0.0824 USD/kWh, rendering its integration with ORC infeasible. In conclusion, this study aims to advance the understanding and application of WHR in WWTPs, paving the way for more efficient and sustainable practices in the field.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Bringing solar to agriculture: An interdisciplinary design and analysis of a Concord grape agrivoltaic system

Agrivoltaics presents an opportunity to integrate solar photovoltaics (PV) with agricultural production, but crop-specific challenges and operational constraints remain underexplored. This study develops and evaluates a Concord grape agrivoltaic system in the Lake Erie American Viticulture Area, where vineyards face economic pressures and land use conflicts with solar development. Starting with vertical, tracking, and overhead PV systems, we model photosynthetic photon flux density (PPFD) reduction in grapevines and power generation losses from shading using the Agrivoltaic Radiation Tool (ART). Based on these results, which indicate 0.47 % annual grapevine PPFD loss for vertical designs, 1.6 % for tracking, and up to 25 % for the overhead systems, the vertical and tracking designs are selected for further computational fluid dynamics (CFD) analysis to evaluate airflow interactions. CFD results show that vertical panels do not significantly impact airflow through the grapevine canopy, and that tracking systems in horizontal position may enhance airflow compared to a vine-only scenario. Considering operational constraints for tracking systems, the vertical design is selected for an economic evaluation to reveal key financial outcomes for solar developers (14-year payback period) and growers ($408 reduction in financial losses per acre annually). A sensitivity analysis quantifies uncertainty in power generation (±8.8 %) and PPFD (±5.0 %), ensuring model robustness across different vineyard conditions. Furthermore, these findings provide quantitative evidence for the feasibility of Concord grape agrivoltaics, demonstrating a synergistic opportunity for dual-use solar while preserving cultural heritage in grape-growing regions.

14 SOLAR ENERGY↗

Evaluation of alternatives for the evolution of palm oil mills into biorefineries

Six alternatives for the conversion of an average Colombian palm oil mill (30 t/h) of fresh fruit bunches (FFB) into biorefineries were evaluated. The alternatives studied were: (C1) Production of biogas from the Palm Oil Mill Effluents (POME), (C2) Composting of empty fruit bunches (EFB) and fiber, (C3) Biomass combustion for high pressure steam combined heat and power, (C4) Pellets production, (C5) Biochar production and, (C6) Biochar and bio-oil production. The available biomass could result in up to 125 kWh of electricity, 207 kg of compost, 125 kg of pellet, 44 kg of biochar and 63 kg of bio-oil per metric ton of FFB. The global warming potential (GWP), eutrophication potential (EP), net energy ratio (NER), capital expenditures (CAPEX), operational costs (OPEX), net present value (NPV) and internal rate of return (IRR) were calculated for all the alternatives. GHG reductions of more than 33% could be achieved. Anaerobic digestion and composting contributed to 30% reduction of the EP. The CAPEX for all of the biorefinery alternatives studied varies between 0.7 $/t and 2.8 $/t of FFB. The OPEX varies between 1.6 $/t and 7.3 $/t of FFB. The NPV for viable scenarios ranged between 2.5 million and 13.9 million US dollars. The IRR calculated varied between 3% and 56% and the payback periods were between 3 and 8 years. The total extra incomes reached values up to 15.2 $/t of FFB. Overall the pellets production biorefinery was the preferred alternative.

palm oil mill, biorefinery comparison, Life Cycle ↗

Daylight performance of a microstructured prismatic window film in deep open plan offices

Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Here, a microstructured prismatic film designed for such use was characterized using goniophotometric measurements and ray tracing simulations. The synthetically-generated bidirectional scattering distribution function (BSDF) data were shown to have good agreement with limited measured data for normal incident angles (0–60°). Measured data indicated that the prismatic film was most efficient when vertical angles of incidence were between 18 and 35° and within ±45° of normal incidence to the plane of the window so maximum energy savings across the full depth of the zone occurred over the equinox to winter solstice period. Annual lighting energy use and visual comfort in a deep open plan office zone were evaluated using the Radiance three-phase method in several climates and for south and east-facing window orientations. Lighting energy savings were 39–43% for a 12 m (40 ft) deep south-facing perimeter zone compared to the same zone with no lighting controls. The prismatic film with and without a diffuser controlled glare for views parallel to the window but produced glare for seated viewpoints looking toward the window. At mature market costs, the system was projected to have a simple payback of 2–6 years. Technical challenges encountered throughout the evaluation led to improvements in measurement and modeling tools and stressed the importance of having accurate input data for product development.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat

This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

Wang, Weimin↗

Building commissioning costs and savings across three decades and 1500 North American buildings

B.V. Building commissioning (Cx) is a process for assuring efficient building operations that can be applied to new construction and existing buildings, resulting in energy and non-energy benefits. Quantifying the benefits of commissioning is challenging, but a 2009 study of 643 commercial buildings provided a solid initial data set to which we added 839 additional buildings for a significantly expanded and updated meta-analysis representing 34.7 million square meters (373 million square feet) of floor area. Since 2009 the commissioning industry has continued to grow, driven by building codes, utility programs, and rising awareness of commissioning benefits. In parallel, building controls have become more sophisticated, and analytics software has emerged to assist with commissioning. We find that delivery mechanism and market segment are key determinants of outcomes, although significant and cost-effective savings are found across the spectrum. Median primary energy savings for Cx projects in existing buildings ranged from 5 percent for those conducted under utility programs, 9 percent for monitoring-based commissioning utility programs (i.e., augmented with submetering and diagnostics), and 14 percent for Cx projects outside of utility programs. Across all project types, median savings ranged from 3 percent for the lodging market segment to 16 percent for public order and safety facilities. Outcomes did not vary significantly by building size or by market segment. Energy savings are rarely estimated for new construction commissioning. We found that the median costs of Cx were lower for the 2018 sample than for the 2009 sample—$\$$2.85 per square meter ($\$$0.26 per square foot) for existing buildings (a 33 percent reduction) and $\$$8.78 per square meter ($\$$0.82 per square foot) for new construction (a reduction of almost 50 percent). The median simple payback time for existing buildings was 1.7 years, with a 25th–75th percentile range of 0.8–3.5 years. Overall, this article summarizes these and other key findings, and discusses how the 2018 data reflects shifts in commissioning practice and outcomes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Framework to select robust energy retrofit measures for residential communities

Residential building energy retrofits are essential for enhancing environmental sustainability and reducing energy costs. The selection of retrofit measures is influenced by factors such as building systems, occupant behavior, government policy, weather variability, and climate change, all of which can significantly impact energy performance. Compared to retrofitting individual homes, evaluating and selecting optimal retrofit solutions for an entire community is challenging due to diverse residential compositions and variability present. Therefore, engineering robustness is crucial for ensuring consistent energy performance and resilience across different conditions. In this context, robustness refers to the ability of a retrofit measure to maintain its functionality and remain an optimal choice despite external disturbances or changes in inputs and conditions. This study presents a framework for evaluating the robustness of multiple retrofit measures across various building systems, occupant behaviors, and environmental scenarios at the community level. The framework comprises five key steps: scenario model development, integration of the National Residential Efficiency Measures database, energy performance simulation, cost-benefit aggregation, and retrofit solution selection. Each step enhances the framework’s robustness by incorporating the diversity of building characteristics, occupant behaviors, environmental conditions, retrofit options, and evaluation criteria. The framework’s effectiveness is demonstrated through a case study in southern Michigan in the United States, which includes 63 one-story single-family houses, 121 two-story single-family houses, and 8 townhouses. The study identifies furnace retrofits as the most robust solution for the entire community, consistently achieving source energy reductions of 4.7 %–8.0 % and payback period of 10–20 years across various scenarios. These findings are consistent with previous research, indicating the framework’s potential for broader applications in optimizing community-scale residential energy retrofits.

Shu, Lei↗

Optimal investment and scheduling of distributed energy resources with uncertainty in electric vehicles driving schedules

The large scale penetration of electric vehicles (EVs) will introduce technical challenges to the distribution grid, but also carries the potential for vehicle-to-grid services. Namely, if available in large enough numbers, EVs can be used as a distributed energy resource (DER) and their presence can influence optimal DER investment and scheduling decisions in microgrids. In this work, a novel EV fleet aggregator model is introduced in a stochastic formulation of DER-CAM [1], an optimization tool used to address DER investment and scheduling problems. This is used to assess the impact of EV interconnections on optimal DER solutions considering uncertainty in EV driving schedules. Optimization results indicate that EVs can have a significant impact on DER investments, particularly if considering short payback periods. Furthermore, results suggest that uncertainty in driving schedules carries little significance to total energy costs, which is corroborated by results obtained using the stochastic formulation of the problem.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

Cost Analysis of Plug-In Hybred Electric Vehicles Using GPS-Based Longitudinal Travel Data

Using spatial, longitudinal travel data of 415 vehicles over 3 18 months in the Seattle metropolitan area, this paper estimates the operating costs of plug-in hybrid electric vehicles (PHEVs) of various electric ranges (10, 20, 30, and 40 miles) for 3, 5, and 10 years of payback period, considering different charging infrastructure deployment levels and gasoline prices. Some key findings were made. (1) PHEVs could help save around 60% or 40% in energy costs, compared with conventional gasoline vehicles (CGVs) or hybrid electric vehicles (HEVs), respectively. However, for motorists whose daily vehicle miles traveled (DVMT) is significant, HEVs may be even a better choice than PHEV40s, particularly in areas that lack a public charging infrastructure. (2) The incremental battery cost of large-battery PHEVs is difficult to justify based on the incremental savings of PHEVs operating costs unless a subsidy is offered for largebattery PHEVs. (3) When the price of gasoline increases from $4/gallon to $5/gallon, the number of drivers who benefit from a larger battery increases significantly. (4) Although quick chargers can reduce charging time, they contribute little to energy cost savings for PHEVs, as opposed to Level-II chargers.

Wu, Xing↗

Economic feasibility of in-motion wireless power transfer in a high-density traffic corridor

Electricity is expected to become a dominant power source in the transportation sector, but under a stationary recharging model, electric powered vehicles still suffer some disadvantages relative to conventional vehicles. Recent developments in wireless power transfer (WPT) technology can enable an alternative vehicle recharging model wherein power is supplied to vehicles while they are moving, mitigating the need for charging stops and high-capacity on-board energy storage. One of the greatest concerns associated with dynamic WPT is that the required infrastructure costs would be prohibitively high; however, the life-cycle costs and benefits of such a system have been under-researched. Here in this work, we apply a systems-level assessment to a case study of a WPT charging system located on the densely trafficked I-710 corridor in Los Angeles, California. Detailed cost estimates for electronics and implementation, high-fidelity energy consumption modeling, and survey-derived adoption projections are applied to evaluate scenarios of economic feasibility and environmental impact. Results show that a “1st-of-a-kind” system can achieve a payback in 20 years while maintaining operating cost advantages relative to petroleum fueling. System economics are shown to improve substantially with “nth-of-a-kind” capital costs. Discussion focuses on the effect of uptake trajectory on economic viability and detailed economics outcomes for light duty and heavy duty vehicles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic analysis and life cycle assessment for electrochemical ammonia production using proton conducting membrane

Green ammonia production is facing increasing interest on a global scale as a hydrogen carrier for power generation as well as fertilizer for food production. The conventional Haber-Bosch method for ammonia synthesis is energy demanding, requires high purity hydrogen, and is based on fossil fuels. A preliminary techno-economic model for electrochemical ammonia synthesis at near ambient pressure using feed rates of 32 metric ton/day for hydrogen and 135 metric ton/day for nitrogen is presented in this study. Various pathways using different methods for nitrogen generation and hydrogen production were investigated to gain insight into added energy savings per metric ton of ammonia. Electrochemical synthesis using electrolysis for hydrogen and cryogenic nitrogen was found to be a potentially viable pathway for green ammonia. The profitability metrics including discounted cash flow rate of return, net present value and discounted payback period were estimated to be 8%, $40 MM, and 4–6 years respectively for this pathway. The cost of electricity, conversion rate, and conversion efficiency dominate the tonnage cost of ammonia and were used to assess the feasibility of the model. A life cycle assessment was also conducted to assess the environmental impact of a well to product ammonia process.

08 HYDROGEN↗

Economic and environmental impacts of a non-traditional combined heat and power system for a discrete manufacturing facility

Combined heat and power (CHP) is an electricity generation strategy that benefits all sides with a vested interest in the nations’ energy future. The technology allows for the efficient production of electricity and heat, which in turn reduces the carbon footprint and energy costs of a facility with significant heat and electricity loads. This paper investigates, through a detailed dynamic simulation, how a highly non-traditional CHP facility can leverage those forces to economically and environmentally benefit. Four system configurations of a composites manufacturing facility, one existing and three proposed systems, including two CHP configurations and one combined cooling, heating, and power (CCHP) configuration are evaluated from both economic and environmental views. The three proposed configurations are based on a 600 kW microturbine as the primary mover. The dynamic model showed great potential to capture the dynamics of the system configurations including the dynamics of temperature, oven exhaust fraction, electrical efficiency, and overall efficiency of the system configurations. All 3 CHP systems have a payback period between 8.03 and 8.33 years. The proposed system configurations reduce up to 22.7% of the CO 2 emission compared to the existing facility, supplying the demands in a cleaner manner.

42 ENGINEERING↗

Techno-economic and environmental assessment of solar-based electrical vehicles charging stations integrated with hydrogen production

With the growing interest in adopting both commercial and residential electric vehicles (EVs) utilizing green renewable energy, the techno-economic assessment of EV charging stations with solar energy is a critical aspect of the transition to sustainable transportation. However, battery storage capacity for variable solar energy production is becoming increasingly less cost-effective due to the higher Lithium price. Complementing solar energy production and battery storage, the potential of combining green hydrogen fuel energy integration with solar energy for EV charging stations can provide a sustainable alternative to reach carbon-free transportation. This research aims to assess the technical and economic viability of grid-connected Photovoltaic (PV)-based EV charging stations across Kentucky based on existing EV load profiles. The study considers different PV system sizes, locations, orientations, and the impact of net metering policies and electricity tariffs on the profitability of the PV systems. Further, using excess PV energy, Lithium-Ion batteries will be charged, which will be assessed considering the techno-economic and environmental impacts of green EV charging stations. To further enhance green renewable energy production, we also investigated the feasibility of on-grid PV-based EV charging stations with Lithium-Ion batteries charged during low tariff periods. In comparison with these scenarios, we studied the potential benefits of integrating green hydrogen energy production using excess solar energy with and without governmental incentives. Furthermore, we assess the environmental impact of these green EV charging stations across Kentucky. Our study indicates that EV stations across Kentucky have similar techno-economic feasibility with insignificant deviation in the levelized cost of electricity, payback period, and PV energy fraction with/without Li-Ion batteries. However, with green hydrogen production, the marginal H 2 production cost indicates the first scenario (on-grid PV energy charging) is the most significant, roughly 10 USD/Kg, which is similar to 1.5 times higher than the second (charging during low-tariff periods) and the third scenarios (power grid to satisfy the demand deficit - approximately 6.5 USD/Kg). From the environmental perspective, the second scenario would be a good option for either hybrid EV/H 2 or EV charging stations in Kentucky, factoring in the hydrogen production cost and the carbon footprint.

08 HYDROGEN↗

Improving dairy manure hydrolysis and acidification through microbial community restructuring by adaptation to hyperthermophilic conditions

Dairy manure (DM) contributes significantly to greenhouse gas emissions and ecosystem degradation, yet its resistance to biodegradation hinders widespread bioprocessing applications. Lignocellulosic materials in DM pose a particular challenge because of their recalcitrance. Bioprocessing under hyperthermophilic (≥70 °C) conditions potentially offers an advantage over traditional fermentation temperatures due to enhanced activity of enzymes and the kinetics of enzymatic reactions. This can lead to a higher conversion rate and a greater extent of biomass hydrolysis and acidification. To test the validity of this hypothesis, the current study evaluated the efficacy of anaerobic hydrolysis and acidogenic fermentation of DM under mesophilic, thermophilic, and hyperthermophilic conditions. All inocula were adapted to corresponding temperatures but were derived from the same mesophilic source. Hyperthermophilic conditions resulted in superior DM hydrolysis efficiency (53%) compared to mesophilic (34%) and thermophilic (42%) conditions. The hyperthermophilic environment was particularly favorable to the decomposition of crude proteins and hemicellulose, which were reduced by 64% and 54%, respectively. Furthermore, hyperthermophilic fermentation also yielded the highest volatile fatty acid (VFA) production rate of 460 mg/L/day during the first four days, representing improvements of 50% and 90% over mesophilic and thermophilic conditions. In part, this was attributed to the enhanced production of branched-chain VFAs, including an increase of 6–10% in isobutyric acid and 12–13% in isovaleric acid. At hyperthermophilic conditions, however, there was no accumulation of VFAs during the days 5–8 of fermentation, which could be due to acetate conversion by the syntrophic acetate-oxidizing bacteria. A considerable gain in hydrolysis efficiency and VFA production rate were accompanied by a reduction in microbial diversity, which suggests that hyperthermophilic temperature is a favorable environment for the selection of organisms with enhanced DM hydrolysis and fermentation capabilities. A significantly increased relative abundance of xylanolytic Caldicoprobacter (23% of population) and proteolytic Thermovirga (9% of population) could be the major contributors to improved decomposition of hemicellulose and protein. As revealed by the techno-economic analysis, acidogenic fermentation of DM at 70 °C and a retention period of 4 days provides the greatest positive net present value, highest internal rate of return of 9.2%, and shortest investment payback period of 9 years. Furthermore, this study demonstrates that hyperthermophilic conditions enable superior deconstruction and bioconversion of lignocellulose-containing biomass into VFAs under reduced retention times, offering a promising approach for improving DM management and generating bioproducts.

09 BIOMASS FUELS↗

Life-cycle cost-benefit analysis of a novel self-heating pavement made from coal-derived solid carbon

Winter weather events challenge the safety, efficiency, and sustainability of roadway networks, particularly road bridges vulnerable to climate impacts. Although effective, conventional de-icing methods incur high expenses and cause significant environmental contamination. To address these longstanding issues, a low-cost novel coal-derived carbon enabled smart pavement (CDC-SP) de-icing system was developed, aiming to alleviate traffic delays, severe corrosion, compromised safety, and environmental pollution. However, the economic performance of CDC-SP has not been quantified to guide decision-making. To this end, this paper presents a Life-Cycle Cost-Benefit Analysis (LCCBA) to assess the economic feasibility of the CDC-SP de-icing system for road bridges in five representative urban and rural areas across cool humid and cold humid climate zones. Given the variations and uncertainties of several factors that determine the costs and benefits, a sensitivity analysis was conducted to determine the system’s economic reliability. Additionally, a Monte Carlo simulation (MCS) was performed to quantify the impacts of important factors and identify the most beneficial scenarios. Furthermore, the CDC-SP de-icing systems have demonstrated substantial economic benefits and short payback periods, showing great applicability for rural and urban road bridges with different service levels across multiple climate zones as compared to conventional de-icing methods.

36 MATERIALS SCIENCE↗