Search NASA⌕ Search

SEARCH · Search NASA

Results for “phasor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Immunity Study: Port Impedance Measurement of PMU and PCI testing under EMP

With the increased requirements of real-time grid monitoring, disturbance location, and situation awareness, Phasor Measurement Units (PMUs) have become more critical for the Wide Area Measurement System (WAMS). However, the vulnerability of PMUs has not been well studied, especially under electromagnetic pulse (EMP) scenarios. The stable operation of the power system will be affected directly once EMP damages them. Therefore, studying their immunity to EMP events is urgent and necessary. In this paper, the effective impedance measurement scheme and pulsed current injection (PCI) testing are proposed for the port impedance measurement and immunity levels of PMUs. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then, the circuit of the pulsed current generator is set to generate a damping sinusoid, and the double exponential wave is applied to the port. Finally, using measured impedance as a generator load, the voltage and current responses of different ports are calculated in the PCI testing simulation. In conclusion, results reveal the characteristics of port impedance, waveforms of voltage and current, and distribution of accumulative energy. The relation between port impedance and the waveforms is discussed.

42 ENGINEERING↗

Hybrid Data-Driven Based HVdc Ancillary Control for Multiple Frequency Data Attacks

The high voltage direct current (HVdc) intertie has been applied to provide ancillary-services for ac grids, utilizing the real-time feedback from phasor measurement units (PMUs). However, PMU data communication is vulnerable to false data injection attacks (FDIA) due to protocol defects, thus the HVdc ancillary control and system stability will be threatened. To address this issue, this article proposes a novel HVdc control strategy based on a hybrid data-driven (HDD) methodology. In this work, the HDD methodology is first proposed to detect the types and duration time of multiple frequency attacks. Specifically, the Hilbert Huang transform (HHT) is used to decompose the frequency data, using variational mode decomposition instead of the traditional empirical mode decomposition, to extract data features. Second, a multikernel support vector machine is proposed to classify the attacked data based on the designed distinctive features from HHT. Meanwhile, the attacking duration time is decided using an unsupervised technique. Third, an HDD-based HVdc ancillary control strategy is established to eliminate the effect of FDIAs on the HVdc frequency response. Comprehensive experiments of HDD-based HVdc ancillary controls under different FDIAs suggest that the proposed HDD could fast and accurately classify the FDIAs, and the HDD-based HVdc ancillary control strategy could significantly suppress the impact of the FDIAs.

97 MATHEMATICS AND COMPUTING↗

A Hybrid-Learning Algorithm for Online Dynamic State Estimation in Multimachine Power Systems

With the increasing penetration of distributed generators in the smart grids, having knowledge of rapid real-time electromechanical dynamic states has become crucial to system stability control. Conventional Supervisory Control and Data Acquisition (SCADA)-based dynamic state estimation (DSE) techniques are limited by the slow sampling rates, while the emerging phasor measurement units (PMUs) technology enables rapid real-time measurements at network nodes. Using generator bus terminal voltages, we propose a hybrid-learning DSE (HL-DSE) algorithm to estimate the synchronous machine rotor angle and speed in real time. The HL-DSE takes the power system model into account and trains neuroestimators with real-time data in an online manner. Compared with traditional DSE methods, the HL-DSE overcomes limitations by using a data-driven approach in conjunction with the physical power system model. The time efficiency, accuracy, convergence, and robustness of the proposed algorithm are tested under noises and fault conditions in both small- and large-scale test systems. Simulation results show that the proposed HL-DSE is much more computationally efficient than widely used Kalman filter (KF)-based methods while maintaining comparable accuracy and robustness. In particular, HL-DSE is over 100 times faster than square-root unscented KF (SR-UKF) and 80 times faster than extended KF (EKF). The advantages and challenges of the HL-DSE are also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Event Identification Based on Deep Neural Network With Information Loading

Online power system event identification and classification are crucial to enhancing the reliability of transmission systems. In this study, we develop a deep neural network (DNN) based approach to identify and classify power system events by leveraging real-world measurements from hundreds of phasor measurement units (PMUs) and labels from thousands of events. Two innovative designs are embedded into the baseline model built on convolutional neural networks (CNNs) to improve the event classification accuracy. First, we propose a graph signal processing based PMU sorting algorithm to improve the learning efficiency of CNNs. Second, we deploy information loading based regularization to strike the right balance between memorization and generalization for the DNN. Numerical results based on real-world dataset from the Eastern Interconnection of the U.S power transmission grid show that the combination of PMU based sorting and the information loading based regularization techniques help the proposed DNN approach achieve highly accurate event identification and classification results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning-Based Real-Time Event Identification Using Rich Real PMU Data

A large-scale deployment of phasor measurement units (PMUs) that reveal the inherent physical laws of power systems from a data perspective enables an enhanced awareness of power system operation. However, the high-granularity and non-stationary nature of PMU data and imperfect data quality could bring great technical challenges for real-time system event identification. To address these challenges, this paper proposes a two-stage learning-based framework. In the first stage, a Markov transition field (MTF) algorithm is exploited to extract the latent data features by encoding temporal dependency and transition statistics of PMU data in graphs. Then, a spatial pyramid pooling (SPP)-aided convolutional neural network (CNN) is established to efficiently and accurately identify power events. The proposed method fully builds on and is also tested on a large real-world dataset from several tens of PMU sources (and the corresponding event logs), located across the U.S., with a time span of two consecutive years. We report the numerical results validate that our method has high identification accuracy while showing good robustness against poor data quality.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online PMU Missing Value Replacement Via Event-Participation Decomposition

We introduce a new method for online Phasor Measurement Unit (PMU) missing value replacement. Our approach allows us to decompose PMU event responses into a non-dynamic component (denoted the participation factor) that can be inferred directly from the past and a dynamic component that can be inferred directly from all other PMUs (denoted the event strength). When missing values occur, we can use these two components, which do not rely on the missing index, to estimate the correct value. The method is extremely fast and can easily be used for online applications. Furthermore, extensive testing on real power system event data reveals that our approach achieves state-of-the-art performance in terms of Mean Absolute Percent Errors (MAPEs) for PMU data dropped during event periods. Here, the method also yields an interpretable and simplified view of events for further analysis and applications. The method relies only on PMU data and does not take outside information such as network topology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Latent Interactions for Event Identification via Graph Neural Networks and PMU Data

Phasor measurement units (PMUs) are being widely installed on power systems, providing a unique opportunity to enhance wide-area situational awareness. One essential application is the use of PMU data for real-time event identification. However, how to take full advantage of all PMU data in event identification is still an open problem. Thus, we propose a novel method that performs event identification by mining interaction graphs among different PMUs. The proposed interaction graph inference method follows an entirely data-driven manner without knowing the physical topology. Moreover, unlike previous works that treat interactive learning and event identification as two different stages, our method learns interactions jointly with the identification task, thereby improving the accuracy of graph learning and ensuring seamless integration between the two stages. Moreover, to capture multi-scale event patterns, a dilated inception-based method is investigated to perform feature extraction of PMU data. To test the proposed data-driven approach, a large real-world dataset from tens of PMU sources and the corresponding event logs have been utilized in this work. We report numerical results validate that our method has higher classification accuracy compared to previous methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wavelet and Deep-Learning-Based Approach for Generation System Problematic Parameters Identification and Calibration

Accurate models of generation systems are critical for maintaining reliable and secure grid operations. In this paper, a novel and systematic approach is proposed to identify and calibrate the generation system problematic parameters using continuous wavelet transform (CWT) and advanced deep-learning technology. The phasor measurement unit (PMU) data are used through “event playback” to check whether the parameter calibration is required, and if yes, a group of suspicious parameters will be identified as the primary problematic parameter candidates (PPCs). These primary PPCs are randomly perturbed to generate the event playback simulation data, which are used by the CWT and convolutional neural networks (CNNs) to further narrow down the primary PPCs into a smaller set of candidates. Then, the identified candidates are perturbed again to generate massive event playback simulation data for training a parameter calibration neural network. Here, we designed a multi-output neural network structure to find the mappings between the perturbed parameters and the simulation data using both CNN and long short-term memory (LSTM) models. Finally, the well-trained and tested CNN-LSTM model is used to estimate the accurate value of the suspicious parameters with actual PMU measurements. The proposed CNN-LSTM network can accurately and reliably estimate the generation-system problematic parameters, and has better performance when compared to other machine-learning methods, such as the multilayer perceptron network and the conditional variational autoencoder method. The accuracy and effectiveness of the proposed approach have been validated through simulation and real-world data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Framework for Power System Event Type Identification via Safe Semi-Supervised Techniques

Herein this paper investigates the use of phasor measurement unit (PMU) data with deep learning techniques to construct real-time event identification models for transmission networks. Increasing penetration of distributed energy resources represents a great opportunity to achieve decarbonization, as well as challenges in systematic situational awareness. When high-resolution PMU data and sufficient manually recorded event labels are available, the power event identification problem is defined as a statistical classification problem that can be solved by numerous cutting-edge classifiers. However, in real grids, collecting tremendous high-quality event labels is quite expensive. Utilities frequently have a large number of event records without in-depth details (i.e., unlabeled events). To bridge this gap, we propose a novel semi-supervised learning-based method to improve the performance of event classifiers trained with a limited number of labeled events by exploiting the information from massive unlabeled events. In other words, compared to existing data-driven methods, our method requires only a small portion of labeled data to achieve a similar level of accuracy. Meanwhile, this work discusses and addresses the performance degradation caused by class distribution mismatch between the training set and the real applications. Based on the proposed safe learning mechanism, our model does not directly use all unlabeled events during model training, but selectively uses them through a comprehensive evaluation procedure. Numerical studies on a sizable PMU dataset have been used to validate the performance of the proposed method.

42 ENGINEERING↗

Data-Driven Event Detection of Power Systems Based on Unequal-Interval Reduction of PMU Data and Local Outlier Factor

With the deployment of phasor measurement units (PMU) and wide area measurement system (WAMS), it is feasible to have an insight into the events occurred in power systems based on measured data. Thus, a novel data-driven algorithm based on local outlier factor (LOF) is proposed in this work to detect and locate events in power systems using reduced PMU data. First, the unequal-interval reduction method is presented to reduce the scale of PMU data in sub-stations and reconstruct it in master station of WAMS, which can relieve the burden of communication systems. Then, principle component analysis (PCA)-based similarity search method is proposed to measure the differences of operation state between any two buses. Next, LOF is presented to detect the abnormal events in power systems, and employed to determine the region of the event source. Finally, six cases from the Western electricity coordinating council (WECC) 179-bus power system, a case from the South China power system (SCPS), and a case from the Guangdong power system (GDPS) are utilized to demonstrate the effectiveness of the proposed algorithm. Overall, the results show that proposed algorithm is effective and can be applied to event detection, event location, and online monitoring, which can enhance the situation awareness ability of power system operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detection of Synchrophasor False Data Injection Attack using Feature Interactive Network

The synchrophasor data recorded by Phasor Measurement Units (PMUs) plays an increasingly critical role in the regulation and situational awareness of power systems. However, the widely installed PMUs are vulnerable to multiple malicious attacks from cyber hackers during data transmission and storage. To address this problem, a Modified Ensemble Empirical Mode Decomposition (MEEMD) is proposed first to extract the intrinsic mode functions of each Synchrophasor Data Attacks (SDA). The frequency-based adaptive screening criterion embedded in MEEMD is used to eliminate the false intrinsic mode functions. Next, a Multivariate Convolutional Neural Network (MCNN) is proposed to identify multiple SDA by utilizing the extracted intrinsic mode functions and original SDA as input vectors. A fusion block as the main structure of MCNN is also leveraged to increase the diversity of features and compress the model parameters. Integrating MEEMD and MCNN, a framework with automatic feature extraction and multi-source information fusion capability, referred to as Feature Interactive Network (FIN), is proposed to detect multiple SDA. Based on the proposed FIN framework, six types of SDA are explored for the first time using actual synchrophasor data in FNET/Grideye that was collected from different locations in the U.S. Eastern Interconnection. Finally, a large quantity of experiments with different attack strengths are used to evaluate the adaptability and classification performance of the proposed FIN.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal PMU Restoration for Power System Observability Recovery After Massive Attacks

Cyber-physically resilient power system operation requires rapid recovery of situational awareness after disastrous scenarios such as massive cyber attacks. In this article, the concept of optimal sequential restoration of Phasor Measurement Units is introduced, aiming at rapid recovery of power system observability in post-attack scenarios. Additionally, the observability recovery problem is formulated as a Mixed Integer Linear Programming problem to maximize the cumulative observability level gained over time during the restoration process. Three alternative objective functions-maximizing the number of observable buses, the number of observable branches, and the total amount of observable power flow-are considered. The effectiveness of the proposed optimal strategy is verified by comparing it with heuristic approaches on the IEEE 57-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

NIR fluorescence lifetime macroscopic imaging with a time-gated SPAD camera

The performance of SwissSPAD2 (SS2), a large scale, widefield time-gated CMOS SPAD imager developed for fluorescence lifetime imaging, has recently been described in the context of visible range and fluorescence lifetime imaging microscopy (FLIM) of dyes with lifetimes in the 2.5 – 4 ns range. Here, we explore its capabilities in the NIR regime relevant for small animal imaging, where its sensitivity is lower and typical NIR fluorescent dye lifetimes are much shorter (1 ns or less). We carry out this study in a simple macroscopic imaging setup based on a compact NIR picosecond pulsed laser, an engineered diffuser-based illumination optics, and NIR optimized imaging lens suitable for well-plate or small animal imaging. Because laser repetition rates can vary between models, but the synchronization signal frequency accepted by SS2 is fixed to 20 MHz, we first checked that a simple frequency-division scheme enables data recording for different laser repetition rates. Next, we acquired data using different time gate widths, including gates with duration longer than the laser period, and analyzed the resulting data using both standard nonlinear least-square fit (NLSF) and phasor analysis. We show that the fixed synchronization rate and large gate widths characterizing SS2 (10 ns and over) are not an obstacle to accurately extracting lifetime in the 1 ns range and to distinguishing between close lifetimes. As a result, SS2 and similar very large gated SPAD imagers appear as a versatile alternative to other widefield time-resolved detectors for NIR fluorescence lifetime imaging, including preclinical molecular applications.

FLIM↗

NIR fluorescence lifetime macroscopic imaging with a novel time-gated SPAD camera

SwissSPAD3 is the latest of a family of widefield time-gated SPAD imagers developed for fluorescence lifetime imaging (FLI) applications. Its distinctive features are (i) the ability to define shorter gates than its predecessors (width W < 1 ns), (ii) support for laser repetition rates up to at least 80 MHz and (iii) a dual-gate architecture providing an effective duty cycle of 100%. We present widefield macroscopic FLI measurements of short lifetime NIR dyes, analyzed using the phasor approach. Furthermore, the results are compared with those previously obtained with SwissSPAD2 and to theoretical predictions.

47 OTHER INSTRUMENTATION↗

MindSynchro

This report presents the developments and results of MindSynchro project as part of DOE OE FOA 1861. DOE and Pacific Northwest National Laboratory (PNNL) have made available to FOA awardees datasets containing years of real historical data recorded from various phasor measurement units (PMUs) which are installed in three large US interconnections: Texas (IC A), Western (IC B), and Eastern (IC C). The main goal of the project, which was successfully achieved, was to develop methods for detection and identification of events which are relevant for power grid operation. Tasks performed for achieving the project goals included data exploration and pre-processing, the development and application of physics-based features, data analysis and labeling based on unsupervised learning approaches, training and testing of DSSL models for classification of events which are relevant for power grid operation, and deployment of solutions to cloud environments. The methods developed in the project can potentially provide relevant benefits to power grid asset owners/operators in general in terms of situational awareness. Two main types of outcomes can be provided by these tools: Identification of specific relevant power grid event types: Semi-supervised ML methods developed in the project can adequately employ not only the relatively scarce labeled data but also the large amount of available unlabeled data to train models for detection of specific event types. Such methods enable the application of trained models for the detection of events in a population of PMUs much larger than that associated to the labeled events. Support in data labeling / label validation: Labels are critical for training of models for identification of specific types of events. However, labeling large amounts of data is a manual and tedious process. This means that such process is error prone and is not scalable. Methods developed in the project, based on ensembles of clustering models, have been successfully employed for turning manual labeling into a scalable process. Accurate identification of specific relevant events can provide the operators with immediate situational awareness that could otherwise require hours or days of analysis from domain experts. We envision that such methods could be initially employed in support of post-mortem analysis of events and, as confidence is gained, they could be employed for online/real-time support, providing, among other benefits, insights for avoiding major events which could happen due to a combination of smaller ones. On the longer term, related methods could potentially be employed to improve protection and control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FOA 1861 Data Curation Overview

This document describes the process executed to collect, examine, and consolidate Phasor Measurement Unit (PMU) data from multiple transmission operators into a common dataset. The consolidated PMU data set was further anonymized and distributed to the Department of Energy Funding Opportunity Announcement (FOA) 1861 Big Data Analysis of Synchrophasor Data awardees.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗