Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Spectral Performance of Photon Counting Pixel Detector Using Attenuation Spectra for Test Samples

When a material is placed along the path of an X-ray beam using a broad range of energy X-ray source, the energy dependence of the attenuation for the X-ray photons will be substantially dissimilar for different materials. The process at which X-ray radiation loses its penetrating strength as it travels through a material will be significantly larger for photons with energy above k-edge energy of that material than for those with slightly lower energy. Hence energy resolved X-ray imaging can be used to achieve colour images revealing the material content of the test sample. The attenuation of the spectrum done by scanning an energy window through the spectrum was measured for a number of samples of different materials. The test samples include Sn, Gd and I with K-edge energy at 29 keV, 50 keV and 33 keV, respectively, using a Feinfocus microfocus X-ray source (FTP-105.02) with Medipix2 photon counting chip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hard x-ray phase contrast imaging using single absorption grating and hybrid semiconductor pixel detector

A method for x-ray phase contrast imaging is introduced in which only one absorption grating and a microfocus x-ray source in a tabletop setup are used. The method is based on precise subpixel position determination of the x-ray pattern projected by the grating directly from the pattern image. For retrieval of the phase gradient and absorption image (both images obtained from one exposure), it is necessary to measure only one projection of the investigated object. Thus, our method is greatly simplified compared with the phase-stepping method and our method can significantly reduce the time-consuming scanning and possibly the unnecessary dose. Furthermore, the technique works with a fully polychromatic spectrum and gives ample variability in object magnification. Consequently, the approach can open the way to further widespread application of phase contrast imaging, e.g., into clinical practice. The experimental results on a simple testing object as well as on complex biological samples are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗