Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Statistical characterization of experimental magnetized liner inertial fusion stagnation images using deep-learning-based fuel–background segmentation

Significant variety is observed in spherical crystal x-ray imager (SCXI) data for the stagnated fuel–liner system created in Magnetized Liner Inertial Fusion (MagLIF) experiments conducted at the Sandia National Laboratories Z-facility. As a result, image analysis tasks involving, e.g., region-of-interest selection (i.e. segmentation), background subtraction and image registration have generally required tedious manual treatment leading to increased risk of irreproducibility, lack of uncertainty quantification and smaller-scale studies using only a fraction of available data. We present a convolutional neural network (CNN)-based pipeline to automate much of the image processing workflow. This tool enabled batch preprocessing of an ensemble of N scans = 139 SCXI images across N exp = 67 different experiments for subsequent study. The pipeline begins by segmenting images into the stagnated fuel and background using a CNN trained on synthetic images generated from a geometric model of a physical three-dimensional plasma. The resulting segmentation allows for a rules-based registration. Our approach flexibly handles rarely occurring artifacts through minimal user input and avoids the need for extensive hand labelling and augmentation of our experimental dataset that would be needed to train an end-to-end pipeline. Here we also fit background pixels using low-degree polynomials, and perform a statistical assessment of the background and noise properties over the entire image database. Our results provide a guide for choices made in statistical inference models using stagnation image data and can be applied in the generation of synthetic datasets with realistic choices of noise statistics and background models used for machine learning tasks in MagLIF data analysis. We anticipate that the method may be readily extended to automate other MagLIF stagnation imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Target Detection in SAR Images Based on a Level Set Approach

This paper introduces a new framework for point target detection in synthetic aperture radar (SAR) images. We focus on the task of locating reflective small regions using alevel set based algorithm. Unlike most of the approaches in image segmentation, we address an algorithm which incorporates speckle statistics instead of empirical parameters and also discards speckle filtering. The curve evolves according to speckle statistics, initially propagating with a maximum upward velocity in homogeneous areas. Our approach is validated by a series of tests on synthetic and real SAR images and compared with three other segmentation algorithms, demonstrating that it configures a novel and efficient method for target detection purpose.

97 MATHEMATICS AND COMPUTING↗

Summary Statistics for LC_TA03_130719: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, lithium carbonate (LC). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, LC_TA03_130719, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

Summary Statistics for TA_MP03_130620: Micro-CT Data Acquired at LLNL, Specimen 3 of 3

Using x-ray micro computed tomography (MicroCT), we have characterized the linear attenuation coefficients (LAC), μ, of a sample of a dry powder material, tartaric acid (TA). The specimen was prepared at Lawrence Livermore National Laboratory (LLNL), loaded into a 60mL low density polyethylene (LDPE) bottle. After completed packing, the specimen was scanned following the protocol for MicroCT measurements under Test Plan 79. This particular specimen, TA_MP03_130620, recorded the bulk packing density (mass of sample divided by volume of sample) shown above. Two additional preparations were made and analyzed. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the x-ray data capture and image reconstruction are given in this report. Additional experimental details may be found in the SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an ~80% region or segment of volume elements (“voxels”) lying completely within the sample, away from the walls of the container. We then calculated the mean value, standard deviation and entropy for (a) the high and low energy image segments and for (b) their digital gradient images 2 . The statistics of the initial image of LAC values are called “first order statistics;” those of the gradient image, “second order statistics.” See Seetho for details of the analysis used to obtain the numbers reported in this document.

42 ENGINEERING↗

A Multiphase Validation of Atlas-Based Automatic and Semiautomatic Segmentation Strategies for Prostate MRI

Purpose: To perform a rigorous technological assessment and statistical validation of a software technology for anatomic delineations of the prostate on MRI datasets. Methods and Materials: A 3-phase validation strategy was used. Phase I consisted of anatomic atlas building using 100 prostate cancer MRI data sets to provide training data sets for the segmentation algorithms. In phase II, 2 experts contoured 15 new MRI prostate cancer cases using 3 approaches (manual, N points, and region of interest). In phase III, 5 new physicians with variable MRI prostate contouring experience segmented the same 15 phase II datasets using 3 approaches: manual, N points with no editing, and full autosegmentation with user editing allowed. Statistical analyses for time and accuracy (using Dice similarity coefficient) endpoints used traditional descriptive statistics, analysis of variance, analysis of covariance, and pooled Student t test. Results: In phase I, average (SD) total and per slice contouring time for the 2 physicians was 228 (75), 17 (3.5), 209 (65), and 15 seconds (3.9), respectively. In phase II, statistically significant differences in physician contouring time were observed based on physician, type of contouring, and case sequence. The N points strategy resulted in superior segmentation accuracy when initial autosegmented contours were compared with final contours. In phase III, statistically significant differences in contouring time were observed based on physician, type of contouring, and case sequence again. The average relative timesaving for N points and autosegmentation were 49% and 27%, respectively, compared with manual contouring. The N points and autosegmentation strategies resulted in average Dice values of 0.89 and 0.88, respectively. Pre- and postedited autosegmented contours demonstrated a higher average Dice similarity coefficient of 0.94. Conclusion: The software provided robust contours with minimal editing required. Observed time savings were seen for all physicians irrespective of experience level and baseline manual contouring speed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LACIE performance predictor final operational capability program description, volume 2

Given the swath table files, the segment set for one country and cloud cover data, the SAGE program determines how many times and under what conditions each segment is accessed by satellites. The program writes a record for each segment on a data file which contains the pertinent acquisition data. The weather data file can also be generated from a NASA supplied tape. The Segment Acquisition Selector Program (SACS) selects data from the segment reference file based upon data input manually and from a crop window file. It writes the extracted data to a data acquisition file and prints two summary reports. The POUT program reads from associated LACIE files and produces printed reports. The major types of reports that can be produced are: (1) Substrate Reference Data Reports, (2) Population Mean, Standard Deviation and Histogram Reports, (3) Histograms of Monte Carlo Statistics Reports, and (4) Frequency of Sample Segment Acquisitions Reports.

Source record↗

Low-level processing for real-time image analysis

A system that detects object outlines in television images in real time is described. A high-speed pipeline processor transforms the raw image into an edge map and a microprocessor, which is integrated into the system, clusters the edges, and represents them as chain codes. Image statistics, useful for higher level tasks such as pattern recognition, are computed by the microprocessor. Peak intensity and peak gradient values are extracted within a programmable window and are used for iris and focus control. The algorithms implemented in hardware and the pipeline processor architecture are described. The strategy for partitioning functions in the pipeline was chosen to make the implementation modular. The microprocessor interface allows flexible and adaptive control of the feature extraction process. The software algorithms for clustering edge segments, creating chain codes, and computing image statistics are also discussed. A strategy for real time image analysis that uses this system is given.

Eskenazi, R.↗

An application of synthetic seismicity in earthquake statistics - The Middle America Trench

The way in which seismicity calculations which are based on the concept of fault segmentation incorporate the physics of faulting through static dislocation theory can improve earthquake recurrence statistics and hone the probabilities of hazard is shown. For the Middle America Trench, the spread parameters of the best-fitting lognormal or Weibull distributions (about 0.75) are much larger than the 0.21 intrinsic spread proposed in the Nishenko Buland (1987) hypothesis. Stress interaction between fault segments disrupts time or slip predictability and causes earthquake recurrence to be far more aperiodic than has been suggested.

Ward, Steven N.↗

Five-Segment Interconnection For Electromigration Tests

Proposed integrated-circuit conductive pattern intended for use in electromigration lifetime testing of interconnection lines of integrated circuits. Designed for collection of statistics on electromigration from smallest possible area. Includes 5 interconnection segments with Kelvin voltage taps, with total of 12 contact pads, and provides for simultaneous measurements on all of segments. Attempts to minimize thermal gradients within each segment and conforms to guidelines on electromigration test structures promulgated by National Institute of Standards and Technology (NIST).

Hannaman, David J.↗

Solar wind density spectra around the ion spectral break

This paper presents a large statistical analysis of ≈5800 frequency spectra of the solar wind density fluctuations in the range 0.001–5 Hz (corresponding to spatial scales of 100–5 × 10{sup 5} km). The analysis confirms that the spectrum consists of three segments divided by two breakpoints and that each of the segments can be described by a power-law function with a spectral index α. The first segment corresponds to MHD scales and is followed by a plateau, and the third segment can be associated with the kinetic range. The statistics show that the values of the spectral slopes depend on the density fluctuations; their increasing amplitude leads to a steepening of each segment. The index of −1.8 can typically be found at MHD scales and averaging of the spectra in the frequency domain leads to an index of −8/3 at kinetic scales, whereas averaging in frequencies normalized to the ion gyrostructure frequency, f{sub g}, defined as the ratio of the solar wind bulk speed and thermal ion gyroradius, provides a value of −7/3. Both breakpoint locations are controlled by the gyrostructure frequency.

79 ASTRONOMY AND ASTROPHYSICS↗

Interactive contour delineation of organs at risk in radiotherapy: Clinical evaluation on NSCLC patients

Purpose: Accurate delineation of organs at risk (OARs) on computed tomography (CT) image is required for radiation treatment planning (RTP). Manual delineation of OARs being time consuming and prone to high interobserver variability, many (semi-) automatic methods have been proposed. However, most of them are specific to a particular OAR. Here, an interactive computer-assisted system able to segment various OARs required for thoracic radiation therapy is introduced. Methods: Segmentation information (foreground and background seeds) is interactively added by the user in any of the three main orthogonal views of the CT volume and is subsequently propagated within the whole volume. The proposed method is based on the combination of watershed transformation and graph-cuts algorithm, which is used as a powerful optimization technique to minimize the energy function. The OARs considered for thoracic radiation therapy are the lungs, spinal cord, trachea, proximal bronchus tree, heart, and esophagus. The method was evaluated on multivendor CT datasets of 30 patients. Two radiation oncologists participated in the study and manual delineations from the original RTP were used as ground truth for evaluation. Results: Delineation of the OARs obtained with the minimally interactive approach was approved to be usable for RTP in nearly 90% of the cases, excluding the esophagus, which segmentation was mostly rejected, thus leading to a gain of time ranging from 50% to 80% in RTP. Considering exclusively accepted cases, overall OARs, a Dice similarity coefficient higher than 0.7 and a Hausdorff distance below 10 mm with respect to the ground truth were achieved. In addition, the interobserver analysis did not highlight any statistically significant difference, at the exception of the segmentation of the heart, in terms of Hausdorff distance and volume difference. Conclusions: An interactive, accurate, fast, and easy-to-use computer-assisted system able to segment various OARs required for thoracic radiation therapy has been presented and clinically evaluated. The introduction of the proposed system in clinical routine may offer valuable new option to radiation oncologists in performing RTP.

60 APPLIED LIFE SCIENCES↗

Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT

Dosimetric comparison of manual beam angle selection (MBS) and beam angle optimization (BAO) for IMRT plans is investigated retrospectively for 15 head and neck and prostate patients. The head and neck and prostate had planning target volumes (PTVs) ranging between 96.0 and 319.9 cm{sup 3} and 153.6 and 321.3 cm{sup 3}, whereas OAR ranged between 8.3 and 47.8 cm{sup 3} and 68.3 and 469.2 cm{sup 3}, respectively. In MBS, a standard coplanar 7-9 fields equally spaced gantry angles were used. In BAO, the selection of gantry angle was optimized by the algorithm for the same number of beams. The optimization and dose-volume constraints were kept the same for both techniques. Treatment planning was performed on the Eclipse treatment planning system. Our results showed that the dose-volume histogram for PTV are nearly identical in both techniques but BAO provided superior sparing of the organs at risk compared with the MBS. Also, MBS produced statistically significant higher monitor units (MU) and segments than the BAO; 13.1 {+-} 6.6% (p = 0.012) and 10.4 {+-} 13.6% (p = 0.140), and 14.6 {+-} 5.6% (p = 1.003E-5) and 12.6 {+-} 7.4% (p = 0.76E-3) for head and neck and prostate cases, respectively. The reduction in MU translates into the reduction in total body and integral dose. It is concluded that BAO provides advantage over MBS for most intenisty-modulated radiation therapy cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessing XMT-Measurement Variability of Air-Water Interfacial Areas in Natural Porous Media

This study investigates the accuracy and reproducibility of air-water interfacial areas measured with high-resolution synchrotron X-ray microtomography (XMT). Columns packed with one of two relatively coarse-grained monodisperse granular media, glass beads or a well-sorted quartz sand, were imaged over several years, encompassing changes in acquisition equipment, improved image quality, and enhancements to image acquisition and to processing software. For the glass beads, the specific solid surface area (SSSA-XMT) of 31.6 ± 1 cm -1 determined from direct analysis of the segmented solid-phase image data is statistically identical to the independently calculated geometric smooth-sphere specific solid surface area (GSSA, 32 ± 1 cm -1 ) and to the measured SSSA (28 ± 3 cm -1 ) obtained with the N2-Brunauer, Emmett, and Teller method. The maximum specific air-water interfacial area (Amax) is 27.4 (±2) cm -1 , which compares very well to the SSSA-XMT, GSSA, and SSSA-N2-Brunauer, Emmett, and Teller values. For the sand, the SSSA-XMT (111 ± 2 cm -1 ) and GSSA (113 ± 1 cm -1 ) are similar. The mean Amax is 96 ± 5 cm -1 , which compares well to both the SSSA and the GSSA values. The XMT-SSSA values deviated from the GSSA values by 7–16% for the first four experiments but were essentially identical for the later experiments. This indicates that enhancements in image acquisition and processing improved data accuracy. The Amax values ranged from 74 cm -1 to 101 cm -1 , with a coefficient of variation (COV) of 9%. The maximum capillary interfacial area ranged from 12 cm-1 to 19 cm -1 , for a COV of 10%. The COVs for both decreased to 5–6% for the latter five experiments. These results demonstrate that XMT imaging provides accurate and reproducible measurements of total and capillary interfacial areas.

54 ENVIRONMENTAL SCIENCES↗

Frequency domain analysis of errors in cross-correlations of ambient seismic noise

We analyse random errors (variances) in cross-correlations of ambient seismic noise in the frequency domain, which differ from previous time domain methods. Extending previous theoretical results on ensemble averaged cross-spectrum, we estimate confidence interval of stacked cross-spectrum of finite amount of data at each frequency using non-overlapping windows with fixed length. The extended theory also connects amplitude and phase variances with the variance of each complex spectrum value. Analysis of synthetic stationary ambient noise is used to estimate the confidence interval of stacked cross-spectrum obtained with different length of noise data corresponding to different number of evenly spaced windows of the same duration. This method allows estimating Signal/Noise Ratio (SNR) of noise cross-correlation in the frequency domain, without specifying filter bandwidth or signal/noise windows that are needed for time domain SNR estimations. Based on synthetic ambient noise data, we also compare the probability distributions, causal part amplitude and SNR of stacked cross-spectrum function using one-bit normalization or pre-whitening with those obtained without these pre-processing steps. Natural continuous noise records contain both ambient noise and small earthquakes that are inseparable from the noise with the existing pre-processing steps. Using probability distributions of random cross-spectrum values based on the theoretical results provides an effective way to exclude such small earthquakes, and additional data segments (outliers) contaminated by signals of different statistics (e.g. rain, cultural noise), from continuous noise waveforms. This technique is applied to constrain values and uncertainties of amplitude and phase velocity of stacked noise cross-spectrum at different frequencies, using data from southern California at both regional scale (~35 km) and dense linear array (~20 m) across the plate-boundary faults. A block bootstrap resampling method is used to account for temporal correlation of noise cross-spectrum at low frequencies (0.05–0.2 Hz) near the ocean microseismic peaks.

58 GEOSCIENCES↗

Stochastic Kinetics of Nanocatalytic Systems

Catalytic reaction events occurring on the surface of a nanoparticle constitute a complex stochastic process. Although advances in modern single-molecule experiments enable direct measurements of individual catalytic turnover events occurring on a segment of a single nanoparticle, we do not yet know how to measure the number of catalytic sites in each segment or how the catalytic turnover counting statistics and the catalytic turnover time distribution are related to the microscopic dynamics of catalytic reactions. Here, we address these issues by presenting a stochastic kinetics for nanoparticle catalytic systems. We propose a new experimental measure of the number of catalytic sites in terms of the mean and variance of the catalytic event count. By considering three types of nanocatalytic systems, we investigate how the mean, the variance, and the distribution of the catalytic turnover time depend on the catalytic reaction dynamics, the heterogeneity of catalytic activity, and communication among catalytic sites. This work enables accurate quantitative analyses of single-molecule experiments for nanocatalytic systems and enzymes with multiple catalytic sites.

Statistical Physics↗

Nuclear emulsion measurements of the astronauts' radiation exposures on Skylab missions 2, 3, and 4

On the Skylab missions, Ilford G.5 and K.2 emulsions were flown as part of passive dosimeter packs carried by the astronauts on their wrists. Due to the long mission times, latent image fading and track crowing imposed limitations on a quantitative track and grain count analysis. For Skylab 2, the complete proton energy spectrum was determined within reasonable error limits. A combined mission dose equivalent of 2,490 millirems from protons, tissue stars and neutrons was measured on Skylab 2. A stationary emulsion stack, kept in a film vault drawer on the same mission, displayed a highly structured directional distribution of the fluence of low-energy protons (enders) reflecting the local shield distribution. On the 59 and 84-day mission 3 and 4, G.5 emulsions had to be cut on the microtom to 5-7 microns for microscopic examination. Even so, the short track segments in such thin layers precluded a statistically reliable grain count analysis. However, the K.2 emulsions still allowed accurate proton ender counts without special provisions.

Schaefer, H. J.↗

Area estimation using multiyear designs and partial crop identification

Progress is reported for the following areas: (1) estimating the stratum's crop acreage proportion using the multiyear area estimation model; (2) assessment of multiyear sampling designs; and (3) development of statistical methodology for incorporating partially identified sample segments into crop area estimation.

Sielken, R. L., Jr.↗

Gravity Wave Energetics Determined From Coincident Space-Based and Ground-Based Observations of Airglow Emissions

Significant progress was made toward the goals of this proposal in a number of areas during the covered period. Section 5.1 contains a copy of the originally proposed schedule. The tasks listed below have been accomplished: (1) Construction of space-based observing geometry gravity wave model. This model has been described in detail in the paper accompanying this report (Section 5.2). It can simulate the observing geometry of both ground-based, and orbital instruments allowing comparisons to be made between them. (2) Comparisons of relative emission intensity, temperatures, and Krassovsky's ratio for space- and ground-based observing geometries. These quantities are used in gravity wave literature to describe the effects of the waves on the airglow. (3) Rejection of Bates [1992], and Copeland [1994] chemistries for gravity wave modeling purposes. Excessive 02(A(sup 13)(Delta)) production led to overproduction of O2(b(sup 1)(Sigma)), the state responsible for the emission of O2. Atmospheric band. Attempts were made to correct for this behavior, but could not adequately compensate for this. (4) Rejection of MSX dataset due to lack of coincident data, and resolution necessary to characterize the waves. A careful search to identify coincident data revealed only four instances, with only one of those providing usable data. Two high latitude overpasses and were contaminated by auroral emissions. Of the remaining two mid-latitude coincidences, one overflight was obscured by cloud, leaving only one ten minute segment of usable data. Aside from the statistical difficulties involved in comparing measurements taken in this short period, the instrument lacks the necessary resolution to determine the vertical wavelength of the gravity wave. This means that the wave cannot be uniquely characterized from space with this dataset. Since no observed wave can be uniquely identified, model comparisons are not possible.

Source record↗