Search NASA⌕ Search

SEARCH · Search NASA

Results for “submillimeter wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Submillimeter wave detection with superconducting tunnel diodes

Superconductor-Insulator-Superconductor (SIS) diodes are the detector elements in the most sensitive heterodyne receivers available from 100 to 500 GHz. SIS mixers are the front end of radio astronomical systems around the world. SIS mixer technology is being extended to 1 THz and higher frequencies for eventual use on spaceborne astronomical experiments. Here is a short review of submillimeter SIS mixers. The role of impedance matching in the proper design of an SIS mixer is described. A variety of methods for achieving good impedance match at submillimeter frequencies are presented. The experimental state of the submillimeter SIS mixer art is described and summarized.

Wengler, Michael J.↗

The laboratory millimeter- and submillimeter-wave spectrum of the first two excited torsional states of (C-13)H3OH

The rotational-torsional spectrum of (C-13)H3OH is presented in both the symmetric and degenerate substates of the first two excited torsional states. Of the new transitions reported, 122 lines are from the v(t) = 1 torsional state and 110 lines are from the v(t) = 2 torsional state, and all are confined to the rotational quantum number J = 8 or less. The data are combined with previously reported millimeter and submillimeter data for the v(t) = 0 torsional state and 44 previously measured excited torsional state lines to form a global data set of 596 transitions, which is analyzed and fitted using an extended internal axis method. The fit results in an overall rms deviation of 1.98 MHz. The spectral constants generated by the fit are used to predict an additional 123 lines of (C-13)H3OH in the v(t) = 1,2 excited torsional states with frequencies up to 612 GHz and rotational quantum number J = 11 or less.

Anderson, Todd↗

The Prospect for Remote Sensing of Cirrus Clouds with a Submillimeter-Wave Spectrometer

Given the substantial radiative effects of cirrus clouds and the need to validate cirrus cloud mass in climate models, it is important to measure the global distribution of cirrus properties with satellite remote sensing. Existing cirrus remote sensing techniques, such as solar reflectance methods, measure cirrus ice water path (IWP) rather indirectly and with limited accuracy. Submillimeter/wave radiometry is an independent method of cirrus remote sensing based on ice particles scattering the upwelling radiance emitted by the lower atmosphere. A new aircraft instrument, the Far Infrared Sensor for Cirrus (FIRSC), is described. The FIRSC employs a Fourier Transform Spectrometer (FTS). which measures the upwelling radiance across the whole submillimeter region (0.1 1.0-mm wavelength). This wide spectral coverage gives high sensitivity to most cirrus particle sizes and allows accurate determination of the characteristic particle size. Radiative transfer modeling is performed to analyze the capabilities of the submillimeter FTS technique. A linear inversion analysis is done to show that cirrus IWP, particle size, and upper-tropospheric temperature and water vapor may be accurately measured, A nonlinear statistical algorithm is developed using a database of 20000 spectra simulated by randomly varying most relevant cirrus and atmospheric parameters. An empirical orthogonal function analysis reduces the 500-point spectrum (20 - 70/cm) to 15 "pseudo-channels" that are then input to a neural network to retrieve cirrus IWP and median particle diameter. A Monte Carlo accuracy study is performed with simulated spectra having realistic noise. The retrieval errors are low for IWP (rms less than a factor of 1.5) and for particle sizes (rins less than 30%) for IWP greater than 5 g/sq m and a wide range of median particle sizes. This detailed modeling indicates that there is good potential to accurately measure cirrus properties with a submillimeter FTS.

Evans, K. Franklin↗

A microwave-biased millimeter- and submillimeter-wave detector using InSb.

Description of a high-purity n-type indium antimonide sample mounted in a reentrant cavity, cooled to 4.2 K, and operated as a millimeter-wave detector. The scheme utilizes a down-conversion process, and free-carrier absorption is the mechanism responsible for the detection process. Power applied at the millimeter-wave frequency causes a change in the material conductivity, which in turn causes a change in the X-band power absorption. Cavity perturbation techniques are used to analyze the scheme. The detector was operated successfully at frequencies between 35 and 150 GHz with no long-wavelength or short-wavelength cutoff observed. The scheme offers a fast, highly sensitive, and rugged detector with low conversion loss.

Eldumiati, I. I.↗

Bulk submillimeter-wave mixers: Strain and superlattices

Strained germanium crystals, doped with gallium, were used as heterodyne mixers at THz frequencies, with infrared bandwidths approaching a GHz. The mixer performance (conversion loss and mixer noise) was analyzed in terms of nonlinearities associated with acceptor levels and with relaxation rates of free holes. Comparison was made with similar mixers employing low lying donor levels in high purity GaAs and with hot electron InSb mixers.

Litvak, M. M.↗

Submillimeter wave survey of the galactic plane

The survey measured, over virtually the entire galactic plane, the distribution and basic physical conditions of the coolest dust component of the interstellar medium. The instrument designed for observations of extended, low surface brightness continuum emission consisted of a balloon borne, gyro stablized, 1.2 m Cassegrain telescope and a liquid cooled photometer. The design, integration, tests, and flight operation of the survey are presented.

Cheung, L. H.↗

Optically pumped submillimeter-waves and applications

Rapid development of optically pumped lasers has shown the potential to be used as a source for a high resolution spectrometer. In this connection, a compact, stable FIR laser was designed, fabricated, and assembled, integrating both the pump laser and the FIR cavity in the same mechanical structure for its improved (both thermal and mechanical) stability and mobility. Performance of the mixer structure which was designed and constructed for the evaluation of the Schottky diodes was found to be satisfactory. The feasibility of generating tunable sideband for molecular spectroscopy studies was demonstrated.

Dutta, J. M.↗

Low-Noise Submillimeter-Wave Diode

Low noise achieved without usual high resistance. Barrier of p-type material placed between metal anode and heavily-doped gallium arsenide. Ntype epitaxial layer eliminated. Barrier prevents quantum tunneling of electrons between semiconductor and metal. Higher breakdown structure provided.

Mattauch, R. J.↗

Submillimeter-wave receivers - A status report

A development status assessment is presented for the work of U.S. and Western European research groups on heterodyne sub-mm receivers in the 300-1000 GHz frequency range. The applications driving sub-mm receiver and local oscillator source technologies are radio astronomy, atmospheric measurements, plasma diagnostics, and laboratory spectroscopy. Progress is concentrated in two areas, cooled Schottky diode mixers and solid state local oscillators employing frequency multipliers.

Wilson, W. J.↗

Submillimeter wave absorption of n-type InSb at low temperatures

The absorption coefficient of two high-purity n-InSb samples is measured in the 10-40 per cm range using Fourier transform spectroscopy. The absorption coefficient spectrum is presented for both samples at 4.2 K. It is also shown for the lower resistance sample cooled to 2.2 K and heated by dc bias to elevated electron gas temperatures of 7.5 and 17.9 K. ac Drude theory gives rather poor agreement with experiment at 2.2 and 4.2 K but does much better when the sample electron gas is heated. In contrast, a simple quantum mechanical theory of absorption based on inverse Bremsstrahlung yields promising agreement at the lower temperatures although its applicability is questionable. The non-Drudian absorption is shown to have a favorable effect on the performance of InSb hot-electron bolometers.

Brown, E. R.↗

Design, fabrication, and performance of a whiskerless Schottky diode for millimeter and submillimeter wave applications

Design considerations, fabrication techniques, and performance predictions are presented for a planar whiskerless Schottky diode to be used (in radio astronomy applications) at 100-300 GHz. The anode and ohmic contacts are on the same side of the device, and proton bombardment is used to establish the divided surface (by making some regions of the GaAs wafer semiinsulating) prior to definition of a B-doped SiO2 finger, ohmic contacting, anode formation, and anode contact metallization (all using photolithographic techniques). The contributions of parasitic elements are calculated for a device with a 3.5-micron-deep n(+) layer doped at 2 x 10 to the 18th/cu cm, a 250-nm-thick epitaxial layer doped at 5 x 10 to the 16th/cu cm, and a 1-micron-radius anode (providing zero-bias junction capacitance 7 fE). It is predicted that such a device would have total series resistance 12.58 ohm and total shunt capacitance 1.37 fF, compared with 14.27 ohm and 0.93 fF for the corresponding whiskered device.

Mckinney, K.↗

Technology for submillimeter wave remote sensing

NASA's sub-mm wave technology development program addresses emerging possibilities in spaceborne sensor design for what is one of the few unexplored regions of the spectrum, from 1.0 to 0.1 mm wavelengths. Astrophysics, earth atmosphere research and solar system exploration can all benefit from the development of such sensor capabilities. Technology status evaluations are presented for Shottky-diode and SIS mixers, solid state and backward wave oscillators, intermodulation frequency amplifiers, and digital autocorrelator and acoustooptic spectrometers.

Sokoloski, Martin M.↗

Millimeter- and submillimeter-wave surveys of Orion A emission lines in the ranges 200.7-202.3, 203.7-205.3, and 330-360 GHz

A continuous spectral line survey of the Orion A position from 330.5 to 360.1 GHz was carried out. This survey covers nearly the entire 870 micron atmospheric window accessible from ground-based observations. Approximately 160 distinct spectral features composed of about 180 lines were detected, 29 of which could not be readily identified. In addition, Orion A from 200.7 to 202.3 GHz and from 203.7 to 205.3 GHz and 42 distinct new spectral lines were detected, including four that are unidentified at present. These data sets are the first thorough survey results in these spectral regions. The new interstellar lines in the survey bands are tabulated and displayed graphically. Moreover, the data are being made available to the Astronomical Data Center at the Goddard Space Flight Center for distribution by request to the astronomical community.

Jewell, P. R.↗

The submillimeter-wave spectrum of (O-16)(O-18)

In order to aid in the interstellar identification of molecular oxygen via its (O-16)(O-18) isotopic species, the frequencies of four rotational fine-structure lines of (O-16)(O-18) have been measured at frequencies ranging from 298 to 464 GHz. The line with the highest intensity and consequent best chance of astronomical detection lies at 401739.823 MHz. Its magnetic dipole strength is somewhat more than half that of the previously measured strong line at 233946.179 MHz.

Crownover, Richard L.↗