Search NASA⌕ Search

SEARCH · Search NASA

Results for “temperature control unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Tuning magnetism in Ising-type van der Waals magnet FePS 3 by lithium intercalation

Recently, layered transition metal thiophosphate MPX 3 (M = transition metals, X = S or Se) have gained significant attention because of their rich magnetic, optical, and electronic properties. Specifically, the diverse magnetic structures and the robustness of magnetism in the two-dimensional (2D) limit have made them prominent candidates to study 2D magnetism. Numerous efforts such as substitutions and interlayer intercalations have been adopted to tune the magnetic properties of these materials, which has greatly deepened the understanding of the underlying mechanisms that govern the properties. In this work, we focus on modifying the magnetism of Ising-type antiferromagnet FePS 3 using electrochemical lithium intercalation. Furthermore, our work demonstrate the effectiveness of electrochemical intercalation as a controllable tool to modulating magnetism, including tuning magnetic ordering temperature and inducing low temperature spin-glass state, offering an approach for implementing this material into applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Autonomous Controls For Reactor Technologies (acorn)

ACORN (Autonomous Controls fOr Reactor techNologies) software utilizes data, obtained from an experimental test bed and/or simulation, to implement a control command for microreactor operation. Command examples include a change to the temperature profile, power profiles, heat fluxes, etc. The control command recommended by the code is derived based on future predicted states of a microreactor, allowing proactive optimal and autonomous microreactor operation. The software is written in Python languages. The current software supports autonomous temperature controls of heat pipe simulator and autonomous heat flux controls of a 37 heat pipe non-nuclear testbed simulator (or its surrogate models).

Lin, Linyu [Idaho National Laboratory (INL), Idaho↗

Performance Evaluation of Liquid-Cooled Open Stand-Alone Refrigerated Cases

This project is part of a joint effort between Commonwealth Edison Company (ComEd) and the National Renewable Energy Laboratory (NREL) to evaluate the energy and demand savings potential of emerging efficient buildings technologies. This project quantifies the energy efficiency benefits from retrofitting an air-cooled, constant-speed compression, self-contained medium-temperature open-vertical display case with a high efficiency water-cooled condensing unit. In addition to a water-cooled heat rejection mechanism, the high-efficiency condensing unit utilizes a variable-speed compressor, electronic expansion valve and advanced controls system. The focus of this project, however, was mainly on capturing the energy savings potentials of the water-cooled condenser, variable-speed compression and electronic expansion valve, and not on the advanced controls. The results of this evaluation will be considered by ComEd and CLEAResult for future energy efficiency rebate offerings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A General Purpose Real-Time Optimization Strategy Applied to Minimizing Simultaneous Heating and Cooling in Buildings

Supervisory control strategies in heating, ventilating, and air-conditioning (HVAC) systems hold the potential for significant energy savings but they are difficult to set up and often depend on unreliable sensor measurements. In this paper, we propose a sensor-free approach to minimizing the energy penalties due to simultaneous heating and cooling in variable-air-volume (VAV) systems with reheat. A general-purpose real-time optimizer is described that is easy to set-up and integrate with existing control logic. A cost function is derived that quantifies the simultaneous heating and cooling penalty that does not require any sensor measurements. The optimizer then minimizes this cost function by automatically adjusting the supply temperature setpoint in the air-handling unit. The paper describes the approach and shows results from application from field trials on a 27-zone building.

Salsbury, Timothy↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reversible Modification of Rashba States in Topological Insulators at Room Temperature by Edge Functionalization

Quantum materials with novel spin textures from strong spin-orbit coupling (SOC) are essential components for a wide array of proposed spintronic devices. Topological insulators have a necessary strong SOC that imposes a unique spin texture on topological states and Rashba states that arise on the boundary, but there is no established methodology to control the spin texture reversibly. Here, it is demonstrated that functionalizing Bi 2 Se 3 films by altering the step-edge termination directly changes the strength of SOC and thereby modifies the Rashba strength of 1D edge states. Scanning tunneling microscopy/spectroscopy shows that these Rashba edge states arise and subsequently vanish through the Se functionalization and reduction process of the step edges. The observations are corroborated by density functional theory calculations, which show that a subtle chemical change of edge termination fundamentally alters the underlying electronic structure. Importantly, fully reversible and repeatable switching of Rashba edge states across multiple cycles at room temperature is experimentally demonstrated. The results imply Se functionalization as a practical method to control SOC and spin texture of quantum states in topological insulators.

Rashba edge states↗

Quantum confining excitons with an electrostatic moiré superlattice

Quantum confining excitons has been a persistent challenge in the pursuit of strong exciton interactions and quantum light generation. Unlike electrons, which can be readily controlled via electric fields, imposing strong nanoscale potentials on excitons to enable quantum confinement has proven challenging. In this study, we utilize piezoelectric force microscopy to image the domain structures of twisted hexagonal boron nitride (h – BN), revealing evidence of strong in-plane electric fields at the domain boundaries. By placing a monolayer MoSe 2 only one to two nanometers away from the twisted h – BN interface, we observe energy splitting of neutral excitons and Fermi polarons by several millielectronvolts at the moiré domain boundaries. By directly correlating local structural and optical properties, we attribute such observations to excitons confined in a nanoscale one-dimensional electrostatic potential created by the strong in-plane electric fields at the moiré domain boundaries. Intriguingly, this 1D quantum confinement results in pronounced polarization anisotropy in the excitons’ reflection and emission, persistent to temperatures as high as ~80 Kelvins. Furthermore, these findings open new avenues for exploring and controlling strongly interacting excitons for classical and quantum optoelectronics.

2-dimensional systems↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Intrinsic kinetics of water-inhibited ultra-lean methane oxidation over PtPd-Mg/ θ -Al 2 O 3 catalyst

Here, this study develops intrinsic methane oxidation kinetics for ultra-lean methane conditions in the presence of water over a highly active and stable PtPd–Mg/θ-Al 2 O 3 catalyst. Comprehensive laboratory experiments were conducted over a wide range of methane concentrations (150–1200 ppm CH 4 ), water contents (1–5% H 2 O), and industrially relevant space velocities (80,000 ≤ GHSV ≤ 160,000 h -1 ). These systematic experiments informed a two-dimensional, axisymmetric, multiscale reactor model that was used to develop and validate methane oxidation kinetics under practically relevant conditions, including non-isothermal operation and high conversion regimes. Combined experimental and modeling results revealed significant intraparticle diffusion resistance and transport-induced reaction exotherm at elevated temperatures, which limited catalyst utilization despite high intrinsic activity. These transport effects were explicitly incorporated into the reactor model, enabling accurate estimation of intrinsic kinetic parameters without reliance on conventional effectiveness-factor corrections. The resulting kinetic model successfully captured both kinetically controlled and mass-transfer-limited regimes and reliably predicted CH 4 conversion across broad ranges of temperature, methane concentration, and water content

Heat and mass transfer limitations↗

Artificial Soiling Replication of Field Losses on Commercial Photovoltaic Modules

Here, this study demonstrates the capabilities of an indoor artificial soiling approach developed to closely replicate the natural, cyclic soil accumulation processes in the field-dust suspension, deposition, and sedimentation/cementation-for a subtropical climate. In this work, a near-field environment is replicated in an artificial soiling cubic chamber through controlled regulation of humidity, temperature, dust type, and dust concentration, based on site-specific historical climate data. Two different models (MA and MB) of full-size commercial photovoltaic modules from a single manufacturer, installed side by side in the mid-Atlantic United States, were retrieved and subjected to artificial soiling experiments and various characterization measurements, including short-circuit current, colorimetry, reflectance, X-ray fluorescence, laser diffraction, and optical microscopy. Both in the field and in our improved field-representative artificial soiling tests, the MA model experienced roughly twice the soiling loss as the MB model. To closely replicate the field soiling losses for a site-specific climate, it is critical to include: 1) The use of field-collected dust with identical dust chemistry and particle distribution instead of standardized ISO 12103 Arizona Road dusts, 2) the use of only a small amount of field-collected dust inside the chamber during the deposition process (e.g., 0.15 g), and 3) the preconditioning of the surface coating for the partial/full dose of UV stress as experienced in the field during sunlight exposure and the abrasion as experienced in the field during regular module cleaning activities, if/as needed. The field-representative artificial soiling method developed here could potentially be adopted for rank ordering of various antisoiling coatings developed by researchers and industry stakeholders.

14 SOLAR ENERGY↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Metal–Organic Frameworks at the Edge of Stability: Mediating Node Distortion to Access Metastable Nanoparticle Polymorphs

Metal-organic frameworks (MOFs) are emerging as unconventional precursors for nanoparticle synthesis, with potential to leverage their tunable structures and chemistry to achieve nanomaterials with structures and compositions inaccessible via traditional synthetic routes. Here we use in situ synchrotron X-ray diffraction and pair distribution function (PDF) measurements to investigate how the dynamic structure of MOFs at the edge of stability influences their transformation into different metastable polymorphs. Our study reveals that the local structural features of metal-oxo MOF nodes at elevated temperatures are linked to the resulting nanoparticle structures formed under mild conditions. Focusing on the titanium-based MOF MIL-125, we demonstrate that manipulating the chemical environment to facilitate transformation of the Ti8 node geometry promotes formation of metastable, nanometer-scale TiO2 brookite rather than the more common anatase and rutile TiO2 polymorphs typically produced through MOF pyrolysis at high temperature. These findings highlight the potential to harness the MOF topology and chemical environment to design and control node distortions and enable access to exotic metastable nanoparticle states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of thermal treatments on electrochemical behavior of binder jetted 17-4 PH stainless steel

Binder jetted 17–4 PH stainless steel was post-processed to relate heat treatment, microstructure, and corrosion in 3.5 wt% NaCl. Specimens were sintered at 1380 or 1400 °C, solution-annealed at 1055 °C for 1 h, and aged at 482 °C for 1 h. Here, as-sintered parts showed α′-martensitic matrix with a δ-ferrite network and Cu-rich precipitates in ferrite; inclusions (MnS, NbC) promoted localized attack. solutionizing redistributed elements and reduced ferrite, while aging generated coherent Cu nano-precipitates. Corrosion resistance was highly sensitive to post-processing in which aged specimens exhibited the lowest corrosion current density and formed a thicker, stable Cr 2 O 3 -rich passive film, whereas sintered specimens degraded most. Pitting potential depended on sintering temperature and microstructure, with 1400 °C sintering yielding more positive pitting potentials and the best overall performance after aging. Although the 1400-solutionized condition showed a relatively noble pitting response versus 1380-solutionized, it displayed unstable corrosion kinetics attributed to an imperfect passive film linked to higher NbC density. XPS depth profiles corroborated these trends, showing thicker, more continuous Cr 2 O 3 in aged states and discontinuous/thinning oxides in less resistant conditions. Practically, high-temperature sintering (∼1400 °C) followed by solutionizing and aging is recommended, with further gains expected from reducing NbC/MnS populations and porosity via powder and process control.

36 MATERIALS SCIENCE↗

Terahertz-field activation of polar skyrons

Unraveling collective modes arising from coupled degrees of freedom is crucial for understanding complex interactions in solids and developing new functionalities. Unique collective behaviors emerge when two degrees of freedom, ordered on distinct length scales, interact. Polar skyrmions, three-dimensional electric polarization textures in ferroelectric superlattices, disrupt the lattice continuity at the nanometer scale with nontrivial topology, leading to previously unexplored collective modes. Here, using terahertz-field excitation and femtosecond x-ray diffraction, we discover subterahertz collective modes, dubbed “skyrons”, which appear as swirling patterns of atomic displacements functioning as atomic-scale gearsets. The key to activating skyrons is the use of the THz field that couples primarily to skyrmion domain walls. Momentum-resolved time-domain measurements of diffuse scattering reveal an avoided crossing in the dispersion relation of skyrons. Atomistic simulations and dynamical phase-field modeling provide microscopic insights into the three-dimensional crystallographic and polarization dynamics. The amplitude and dispersion of skyrons are demonstrated to be controlled by sample temperature and electric-field bias. The discovery of skyrons and their coupling with terahertz fields opens avenues for ultrafast control of topological polar structures.

ferroelectrics↗

Hot Water Recirculation Systems: Designing for Success [Slides]

This presentation will focus on on-demand hot water recirculation systems and how they contribute to energy and water conservation in residential buildings. This work illustrates best practices for designing, installing, and operating these systems, drawing from research and field testing to provide practical recommendations. The ultimate goal is to reduce wait times for hot water, comply with current energy codes, and lower both energy use and greenhouse gas emissions, while improving user satisfaction. In the upcoming slides, we'll dive into case studies and explore the latest technological advancements that help achieve these objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of a magnetic field on hot electron generation from laser-plasma instabilities

We performed two-dimensional simulations of turbulent laser-plasma instabilities in the presence and absence of external magnetic fields using the Laser Plasma Simulation Environment (LPSE) code. The results demonstrate that, in the presence of a magnetic field, the transition from ballistic to gyrating electron motion enhances the energy transfer from electron plasma waves to the electron population. Although stronger magnetic fields produce a larger population of hot electrons, these electrons tend to remain confined near the quarter-critical density, where the instabilities also localize, thereby reducing the potential for hot electron transport deeper into the target. Additionally, we present a scaling analysis that quantifies hot electron generation as a function of plasma electron temperature, density scale length, and applied magnetic field strength. These findings may have important applications for controlling hot electron flux and mitigating preheat in inertial confinement fusion targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Baltimore Ecosystem Study: Soil atmosphere fluxes of carbon dioxide, nitrous oxide and methane, 1998 - ongoing

The Baltimore Ecosystem Study (BES) established a network of long-term permanent biogeochemical study plots in 1998. These plots provide long-term data on vegetation, soil and hydrologic processes in the key ecosystem types within the urban ecosystem. The network of study plots includes forest plots (upland and riparian), chosen to represent the range of forest conditions in the area and grass plots (to represent home lawns). Plots are instrumented with lysimeters (drainage and tension) to sample soil solution chemistry, time domain reflectometry probes to measure soil moisture, dataloggers to measure and record soil temperature, and trace gas flux chambers to measure the flux of carbon dioxide, nitrous oxide and methane from soil to the atmosphere. Measurements of in situ nitrogen mineralization, nitrification and denitrification were made at approximately monthly intervals from Fall 1998 - Fall 2000. Detailed vegetation characterization (all layers) was done in summer 1998 and 2015. Data from these plots has been published in Groffman et al. (2006, 2009), Groffman and Pouyat (2009), Savva et al. (2010), Costa and Groffman (2013), Duncan et al. (2013), Waters et al. (2014), Ni and Groffman (2018), Templeton et al. (2019). Literature Cited Costa, K.H. and P.M. Groffman. 2013. Factors regulating net methane flux in urban forests and grasslands. Soil Science Society of America Journal 77:850 - 855. Duncan, J. M., L. E. Band, and P. M. Groffman. 2013. Towards closing the watershed nitrogen budget: Spatial and temporal scaling of denitrification. Journal of Geophysical Research Biogeosciences 118:1-5; DOI: 10.1002/jgrg.20090 Groffman PM, Pouyat RV, Cadenasso ML, Zipperer WC, Szlavecz K, Yesilonis IC,. Band LE and Brush GS. 2006. Land use context and natural soil controls on plant community composition and soil nitrogen and carbon dynamics in urban and rural forests. Forest Ecology and Management 236:177-192. Groffman, P.M., C.O. Williams, R.V. Pouyat, L.E. Band and I.C. Yesilonis. 2009. Nitrate leaching and nitrous oxide flux in urban forests and grasslands. Journal of Environmental Quality 38:1848-1860. Groffman, P.M. and R.V. Pouyat. 2009. Methane uptake in urban forests and lawns. Environmental Science and Technology 43:5229-5235. DOI: 10.1021/es803720h. Ni, X. and P.M. Groffman. 2018. Declines in methane uptake in forest soils. Proceedings of the National Academies of Science of the United States of America 115:8587-8590. Savva, Y., K. Szlavecz, R. V. Pouyat, P. M. Groffman, and G. Heisler. 2010. Effects of land use and vegetation cover on soil temperature in an urban ecosystem. Soil Science Society of America Journal 74:469-480. Templeton, L., M.L. Cadenasso, J. Sullivan, M. Neel and P.M. Groffman. 2019. Changes in vegetation structure and composition of urban and rural forest patches in Baltimore from 1998 to 2015. Forest Ecology and Management. In press. Waters, E.R., J.L. Morse, N.D. Bettez and P.M. Groffman. 2014. Differential carbon and nitrogen controls of denitrification in riparian zones and streams along an urban to exurban gradient. Journal of Environmental Quality 43:955–963.

Groffman, Peter M↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗