Search NASA⌕ Search

SEARCH · Search NASA

Results for “total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Digging deeper: Buried layers and interfaces studied by modified total electron yield and soft x-ray absorption spectroscopy

We report on the soft x-ray absorption spectroscopy investigation of thin film capacitors using a modified total electron yield detection mode. This mode utilizes two ammeters instead of one as commonly employed in the classical total electron yield scheme to measure photocurrents of devices under soft x-ray irradiation. The advantage of this configuration over the surface sensitive classical total electron yield mode is that it can provide information from buried layers and interfaces up to a thickness equal to the penetration depth of soft x-rays. The method can be easily adapted to existing synchrotron end stations. We investigate dielectric capacitors with dissimilar electrodes to assess the feasibility of the modified total electron yield method. Furthermore, in operando soft x-ray absorption spectroscopy measurements are performed on ferroelectric capacitors under bias and using two ammeters. The experimental results are discussed in terms of the external and internal photoemission processes and their distribution in thin film capacitors under an external bias condition. The proposed detection method opens the way to perform electronic and chemical state analyses of the buried interfaces and layers in various devices like multiferroic tunnel junctions, memristive devices, etc., during operation under an applied bias.

Kröger, E.↗

Deciphering Nb 98 β decay with the Modular Total Absorption Spectrometer at ORNL

An assessment done under the auspices of the Organization for Economic Co-operation and Developement Nuclear Energy Agency (OECD-NEA) in 2007 suggested that the β decays of many abundantly produced fission products in nuclear reactors may be incomplete. In this assessment, the fission product 98 Nb was assigned the highest priority for study by total absorption spectroscopy due to its large cumulative fission branching fraction and because the β-decay data from several experiments are discrepant. To obtain the complete β-decay feeding pattern of 98 Nb and determine the impact on the average γ energy per 98 Nb β decay and v¯e emission calculations. The complete 98 Nb β-decay feeding pattern includes ground-state to ground-state β feeding and direct β feeding to the 0 + first-excited state (both have no associated γ rays), and the ground-state to excited-state β transitions followed by γ transitions to the ground state of the daughter nucleus, 98 Mo. The complete β-decay intensities of 98 Nb were measured with the Modular Total Absorption Spectrometer at Oak Ridge National Laboratory (ORNL). Here, the 98 Nb was produced by the β decay of mass 98 fission fragments at ORNL's On-Line Test Facility (OLTF) using proton-induced fission of 238 U. We find that changes to the current ENSDF assessment of 98 Nb β-decay intensity are required. We report improved uncertainties for the β-decay feeding values and report new β feedings to high-energy levels in 98 Mo. A more complete 98 Nb β-feeding pattern with improved accuracy and precision is offered. The impacts of the measured changes to the 98 Nb β-feeding pattern on both reactor decay heat calculations and predicted detection rates of reactor v¯e are presented. The Modular Total Absorption Spectrometer measurements of 98 Nb demonstrate the importance of reexamining and remeasuring complex β-decaying fission products with total absorption spectroscopy, including nuclei very near β stability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.↗

Effect of wall to total temperature ratio variation on heat transfer to the leeside of a space shuttle configuration at M equals 10.3

An experimental study has been conducted of the influence of wall to total temperature ratio on the heat transfer to the leeside of a 040A space shuttle configuration. The heat transfer tests were made at a Mach number of 10 and a Reynolds number of one million per foot for angles of attack from 0 deg to 30 deg. Range of wall to total temperature ratio was from 0.16 to 0.43. Where the heat transfer was relatively high and the laminar boundary layer attached, the local heat transfer decreased by about 20 percent as the wall to total temperature ratio was increased from the minimum to the maximum test value. On regions of separated flow and vortex reattachment, very low heating rates were measured at some conditions and indicate significant changes are occurring in the leeside flow field. No single trend of heat transfer variation with wall to total temperature ratio could be observed.

Dunavant, J. C.↗

Variational energy principle for compressible, baroclinic flow. 1: First and second variations of total kinetic action

The case of a cold gas in the absence of external force fields is considered. Since the only energy involved is kinetic energy, the total kinetic action (i.e., the space-time integral of the kinetic energy density) should serve as the total free-energy functional in this case, and as such should be a local minimum for all possible fluctuations about stable flow. This conjecture is tested by calculating explicit, manifestly covariant expressions for the first and second variations of the total kinetic action in the context of Lagrangian kinematics. The general question of the correlation between physical stability and the convexity of any action integral that can be interpreted as the total free-energy functional of the flow is discussed and illustrated for the cases of rectillinear and rotating shearing flows.

Schmid, L. A.↗

Periodic variations of total ozone and of its vertical distribution

The phase and amplitude of the annual, semiannual, and quasi-biennial oscillations to total ozone data for the Northern Hemisphere in the period 1957-1972 and for Northern Hemisphere ozonesonde data for variable periods from 1962-1974 have been plotted as functions of latitude, longitude, and altitude. The largest annual wave amplitude in total ozone occurs over eastern Siberia. In total ozone, the region of maximum quasi-biennial oscillation (QBO) coincides with that of the annual wave. The major feature of the QBO in the vertical distribution is the maximum amplitude in the arctic just above the tropopause. As for the semiannual wave, the maximum in total ozone lies in the arctic, displaced slightly to the Siberian side. In the vertical, its maximum amplitude is near 18 km. The phase appears to progress poleward, with maxima at high latitudes occurring in March-April.

Wilcox, R. W.↗

Strainrange partitioning: A total strain range version

Procedures are presented for expressing the Strainrange Partitioning (SRP) method for creep fatigue life prediction in terms of total strain range. Inelastic and elastic strain-range - life relations are summed to give total strain-range - life relations. The life components due to inelastic strains are dealt with using conventional SRP procedures while the life components due to elastic strains are expressed as families of time-dependent terms for each type of SRP cycle. Cyclic constitutive material behavior plays an important role in establishing the elastic strain-range - life relations as well as the partitioning of the inelastic strains. To apply the approach, however, it is not necessary to have to determine the magnitude of the inelastic strain range. The total strain SRP approach is evaluated and verified using two nickel base superalloys, AF2-1DA and Rene 95. Excellent agreement is demonstrated between observed and predicted cyclic lifetimes with 70 to 80 percent of the predicted lives falling within factors of two of the observed lives. The total strain-range SRP approach should be of considerable practical value to designers who are faced with creep-fatigue problems for which the inelastic strains cannot be calculated with sufficient accuracy to make reliable life predictions by the conventional inelastic strain range SRP approach.

Halford, G. R.↗

Active-region evolution and solar rotation variations in solar UV irradiance, total solar irradiance, and soft X rays

Variations in the total solar irradiance, solar UV spectral irradiance, and solar soft X-ray emission caused by active region evolution and solar rotation are analyzed by using concurrent measurements from the NIMBUS 7 and GOES satellites. The observations are interpreted by using simple empirical models that relate ground-based observations of the size and location of sunspots and plages to the full-disk temporal variations. It is found that the major dips in the photospheric total solar irradiance S, which are evident in both satellite measurements and model predictions, are usually not accompanied by outstanding enhancements in the chromospheric and upper photospheric UV spectral irradiance or coronal X rays. The main cause of this difference between the variability of S and of the UV flux is that the total chromospheric plage enhancements are not outstanding at those times when the total sunspot are outstanding. X rays are even more variable because of a much wider CMD sensitivity.

Donnelly, R. F.↗

Strainrange partitioning - A total strain range version

Procedures are presented for expressing the Strainrange Partitioning (SRP) method for creep fatigue life prediction in terms of total strain range. Inelastic and elastic strain-range - life relations are summed to give total strain-range - life relations. The life components due to inelastic strains are dealt with using conventional SRP procedures while the life components due to elastic strains are expressed as families of time-dependent terms for each type of SRP cycle. Cyclic constitutive material behavior plays an important role in establishing the elastic strain-range life relations as well as the partitioning of the inelastic strains. To apply the approach, however, it is not necessary to have to determine the magnitude of the inelastic strain range. The total strain SRP approach is evaluated and verified using two nickel base superalloys, AF2-1DA and Rene 95. Excellent agreement is demonstrated between observed and predicted cyclic lifetimes with 70 to 80 percent of the predicted lives falling within factors of two of the observed lives. The total strain-range SRP approach should be of considerable practical value to designers who are faced with creep-fatigue problems for which the inelastic strains cannot be calculated with sufficient accuracy to make reliable life predictions by the conventional inelastic strain range SRP approach.

Halford, G. R.↗

Further interpretation of satellite measurements of Antarctic total ozone

Both dynamical and chemical mechanisms have been advanced to explain the decrease in total ozone in the Antarctic spring. Further analysis of satellite measurements show that during any one year, the September decline in total ozone near the South Pole is compensated by an increase at midlatitudes. The total ozone amount from 44 deg S to the pole remains almost unchanged from August through November even though both the polar and midlatitude values reach extremes during this period. These observations suggest that the variations within the spring season in south polar total ozone are governed by dynamical redistribution rather than chemical processes.

Stolarski, Richard S.↗

Predictions for the total solar eclipse of 1988

A total eclipse of the sun will be widely visible from the East Indies on March 18, 1988. Detailed predictions for this event are presented which include tables of geographic coordinates for the northern limit, center line and southern limit of the path of totality, local circumstances for 40 cities within the total and partial eclipse paths, the lunar-limb profile, and maps depicting the path of totality. The author discusses the general characteristics of the eclipse, local circumstances from various points along the central path and the Saros-series history.

Espenak, Fred↗

An analysis of tropopause pressure and total ozone correlations

A study of the relationship between total ozone and tropopause pressure was carried out using Total Ozone Mapping Spectrometer (TOMS) data and National Meteorological Center (NMC) global analyses. The medium scales generally show correlations greater than 0.6 throughout the middle latitudes of both hemispheres with some regions exceeding 0.8. The areas of highest correlations seem to be associated with the storm track regions of both the Northern and Southern Hemispheres. A detailed spectral analysis is performed for the medium scales on five pairs of time series of area averaged tropopause pressure and total ozone. In middle latitudes, total ozone and tropopause pressure exhibit generally similar distributions in the power spectrum. In the subtropics and tropics the power in ozone drops off more rapidly with increasing frequency than the power in tropopause pressure. Only in the Northern Hemisphere middle latitudes does one find a clear association between increased power in ozone and tropopause pressure and maxima in the coherency spectrum. Results for large scales are more complicated, showing generally positive correlations at middle latitudes.

Schubert, Siegfried D.↗

An analysis of the 7-year record of SBUV satellite ozone data - Global profile features and trends in total ozone

Results are presented from an analysis of Nimbus 7 SBUV monthly-average total ozone data for the November 1978 - September 1985 period. Linear drifts are estimated for the differences between SBUV and Dobson ground station total ozone data. The results show an average negative linear drift in SBUV data relative to Dobson data of about -0.4 percent per year. The global estimate of the relation between total ozone and solar flux variations is 0.97 + or - 0.61/100 solar flux units, representing a change of total ozone over the 7-year period associated with solar flux variations of about -0.20 + or - 0.13 percent per year.

Reinsel, Gregory C.↗

The characterization of an air pollution episode using satellite total ozone measurements

A case study is presented which demonstrates that measurements of total ozone from a space-based platform can be used to study a widespread air pollution episode over the southeastern U.S. In particular, the synoptic-scale distribution of surface-level ozone obtained from an independent analysis of ground-based monitoring stations appears to be captured by the synoptic-scale distribution of total ozone, even though about 90 percent of the total ozone is in the stratosphere. Additional analyses of upper air meteorological data, other satellite imagery, and in situ aircraft measurements of ozone likewise support the fact that synoptic-scale variability of tropospheric ozone is primarily responsible for the observed variability in total ozone under certain conditions. The use of the type of analysis discussed in this study may provide an important technique for understanding the global budget of tropospheric ozone.

Fishman, Jack↗

The sensitivity of total ozone and ozone perturbation scenarios in a two-dimensional model due to dynamical inputs

The sensitivity of the total ozone distribution in the Douglass et al. (1989) photochemical model to the dynamical inputs of ozone and the zone perturbation scenarios was investigated by computing the residual circulation from three sets of heating rates (used in computing the advection field). The model ozone results were compared to solar backscattered UV ozone data (SBUV). It was found that, depending on the dynamical inputs, the modeled global average total ozone varied up to 10 percent (with even more substantial seasonal and latitudinal variabilities), indicating that total ozone in the middle to high latitudes is very sensitive to the advection field below 100 mbar, the region where the heating rates are most uncertain. The modeled total ozone showed better agreement with solar SBUV climatology when computed horizontal eddy diffusion was used.

Jackman, Charles H.↗

Global patterns of the quasi-biennial oscillation in total ozone

The global structure of the quasi-biennial oscillation (QBO) in total ozone is examined using nine years of total ozone measurements from the Nimbus 7 Total Ozone Mapping Spectrometer. It is shown that the interannual variations of total ozone near the equator are dominated by the QBO and that extratropical anomalies of either sign are largest in the winter season in each hemisphere. Coherent patterns of correlation are found between the equatorial ozone and eddy variances of the ozone field at the equator and in the adjacent subtropics.

Bowman, Kenneth P.↗

Interannual variations of ozone - Interpretation of 4 years of satellite observations of total ozone

Observations show that the monthly zonal mean total ozone between 1978 and 1982 varies by as much as 5 percent with respect to the 4-year average. These variations have been analyzed with the aid of a two-dimensional chemistry transport model. Observed temperatures and meridional stream functions, calculated from data, were used as inputs for the model. Deviations of the model-calculated total ozone from the 4-year mean were compared with the observed variations. It is shown that a substantial part of the observed variability of total ozone is reproduced by the model, despite uncertainties in the heating rates and without any special attempts to obtain consistent eddy diffusion or otherwise to tune the model. Results indicate that the temperature dependence of the ozone gas phase chemistry plays a negligible role in explaining the observed interannual variations in total ozone. A large part of the variability can be explained by the year-to-year differences in the transport circulation. The variability of the diabatic circulation is shown to be largely independent of the ozone fluctuations and to be a consequence of the observed temperature variations.

Schneider, Hans R.↗