Search NASA⌕ Search

SEARCH · Search NASA

Results for “transient storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 127 records · Page 7

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Physics-aware adaptive checkpointing with shadow systems for nonlinear PDE simulations

Large-scale simulations of nonlinear partial differential equations (PDEs) that exhibit strongly transient behavior and pattern-forming dynamics produce enormous amounts of data, which, even with modern storage systems, cannot be stored for later curation. Current I/O strategies either write dense time series of snapshots, which is often prohibitive in I/O and storage, or store a few checkpoints that enable restart but incur expensive recomputation cost and provide no control over post-restart error growth, especially when lossy compression is used. Moreover, most, if not all, existing strategies take no account of the actual physical state of the system. Here, we present a simple physics-aware I/O framework in which a low-cost shadow system adaptively triggers lossy checkpoints when the shadow system deviates from the fine-scale simulation. The shadow system can be a coarsened replica of the fine-scale simulation that evolves concurrently. This means that checkpoints are taken based on the physical state of the system: fewer checkpoints are triggered when the system is quiescent while more are taken when the system undergoes a rapid change. This type of behavior is observed in many systems such as Brusselator and FitzHugh–Nagumo. We illustrate that our framework maintains stable restarts, keeps fine-scale restart errors bounded by shadow errors, and reconstructs the time history with significantly lower error and storage than interpolating fixed-interval snapshots, with low-cost shadow replay and modest online synchronization overhead.

Gong, Qian [ORNL] (ORCID:0000000235704142)↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Enhancing Local Grid Resilience with Small Hydropower Hybrids: Proving the concept through demonstration, simulation, and analysis with Idaho Falls Power

Large hydropower, connected to the transmission system and typically possessing significant ability to balance grid frequency, has long been central to black start plans in regions where it is present. Small hydropower possesses most of the attributes required for black start but is often connected to distribution or sub-transmission systems and has less ability to balance grid frequency. Integrating energy storage such as batteries or ultracapacitors increases the combined asset’s ability to balance frequency. This asset integration enables a bottom-up grid restoration paradigm in which critical electric loads on the local distribution system can be powered even when the regional transmission system is down. This report presents a field demonstration conducted with Idaho Falls Power that proved this concept. The contribution of energy storage in restoring the small hydro-dominated distribution grid and its operational sensitivity across different control settings are further analyzed using high-fidelity simulations. Readers will learn about technical details on the field demonstration setup, energy storage contribution to black start, detailed simulation steps of islanded distribution grid restoration, and usage of field demonstration measurements for transient model refinements. Collectively this report points to a great opportunity for small hydropower to enhance resilience of local electric grids.

13 HYDRO ENERGY↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Modeling of a Networked Community Microgrid with High Solar Penetration Considering Control Dynamics of Inverter-Based Resources

Microgrids help facilitate the integration of renewable energy in distribution-level grids and increase the resilience of the electric grid to extreme weather, especially in rural areas. Compared to traditional microgrids, a networked microgrid leverages multiple grid-forming sources to form a potential meshed grid and is more flexible in operation. This paper demonstrates the simulation modeling of an actual networked microgrid located in Adjuntas, Puerto Rico. The model contains representations of power inverters that connect the battery energy storage systems and photovoltaic generation systems to the networked microgrid and is capable of simulating fast grid transients as well as long-term operation of the networked microgrid. The modeling technique for power inverters allows the time-efficient simulation of the microgrid with a minimal penalty on model accuracy.

Li, Dingrui↗

Fuel Cell Stack Model for Real-Time Simulation of Grid-Connected Applications

Fuel cell stacks coupled with electrolyzers and hydrogen storage sites can be a promising category of distributed energy resources for both grid-connected and stand-alone power systems. However, because of high costs, at-scale hardware testing of fuel cell stacks for grid-connected applications is not economically viable at present. A model-based system that can accurately captures the steady-state and dynamic response of fuel cell stacks over long time periods (hours), is needed. This paper demonstrate a real-time electromagnetic transient model of a megawatt-scale, grid-connected proton exchange membrane fuel cell stack, coupled with a mass-based hydrogen storage system. This model can emulate the electrical steady-state and dynamic response of grid-connected fuel cell stacks. We validate the model using the response of commercial hardware fuel cell stacks and analytical models in the literature - using a digital real-time simulator (RSCAD). The proposed real-time model is then used to simulate cases spanning different time horizons and to design controller-hardware-in-the-loop experiments to evaluate controllers for hydrogen stations.

activation potential↗

Chemically Fueled Reinforcement of Polymer Hydrogels

Carbodiimide-fueled anhydride bond formation has been used to enhance the mechanical properties of permanently crosslinked polymer networks, giving materials that exhibit transitions from soft gels to covalently reinforced gels, eventually returning to the original soft gels. Temporary changes in mechanical properties result from a transient network of anhydride crosslinks, which eventually dissipate by hydrolysis. Over an order of magnitude increase in the storage modulus is possible through carbodiimide fueling. Here, the time-dependent mechanical properties can be modulated by the concentration of carbodiimide, temperature, and primary chain architecture. Because the materials remain rheological solids, new material functions such as temporally controlled adhesion and rewritable spatial patterns of mechanical properties have been realized.

36 MATERIALS SCIENCE↗

Matrix Approach to Land Carbon Cycle Modeling

Land ecosystems contribute to climate change mitigation by taking up approximately 30% of anthropogenically emitted carbon. However, estimates of the amount and distribution of carbon uptake across the world's ecosystems or biomes display great uncertainty. The latter hinders a full understanding of the mechanisms and drivers of land carbon uptake, and predictions of the future fate of the land carbon sink. The latter is needed as evidence to inform climate mitigation strategies such as afforestation schemes. To advance land carbon cycle modeling, we have developed a matrix approach. Land carbon cycle models use carbon balance equations to represent carbon exchanges among pools. Our approach organizes this set of equations into a single matrix equation without altering any processes of the original model. The matrix equation enables the development of a theoretical framework for understanding the general, transient behavior of the land carbon cycle. While carbon input and residence time are used to quantify carbon storage capacity at steady state, a third quantity, carbon storage potential, integrates fluxes with time to define dynamic disequilibrium of the carbon cycle under global change. The matrix approach can help address critical contemporary issues in modeling, including pinpointing sources of model uncertainty and accelerating spin-up of land carbon cycle models by tens of times. The accelerated spin-up liberates models from the computational burden that hinders comprehensive parameter sensitivity analysis and assimilation of observational data to improve model accuracy. Such computational efficiency offered by the matrix approach enables substantial improvement of model predictions using ever-increasing data availability. Overall, the matrix approach offers a step change forward for understanding and modeling the land carbon cycle.

54 ENVIRONMENTAL SCIENCES↗

Wind Power as a Virtual Synchronous Generator (WindVSG)

This project investigated the theory, implemented it in hardware, and validated the Wind as a Virtual Isochronous Generator (WindVSG) concept by combining the advantages of modern dynamic inverter technologies with static, dynamic, and transient electromechanical properties of synchronous machines. During this project we demonstrated how to control the inverters of wind turbine generators (wind alone or in parallel with other GFM sources, such battery energy storage) so that wind power behaves like a synchronous machine-based power plant with a conventional prime mover. For this purpose, testing was conducted at NLR ARIES facility with real 2.5 MW wind-turbine generator operating in GFM mode under dynamic and transient conditions. The team also developed models and conducted simulations for GFM wind power to evaluate stability impacts of GFM operation on power grid. This report describes efforts by the NLR team working in collaboration GE Vernova during 3-year project.

17 WIND ENERGY↗

A microfluidic study of transient flow states in permeable media using fluorescent particle image velocimetry

Velocity fields in flow in permeable media are of great importance to many subsurface processes such as geologic storage of CO 2 , oil and gas extraction, and geothermal systems. Steady-state flow is characterized by velocity fields that do not change significantly over time. The flow field transitions to a new steady state once it experiences a disturbance such as a change in flow rate or in pressure gradient. This transition is often assumed to be instantaneous, which justifies the expression of constitutive relations as functions of instantaneous phase saturations. This work examines the evolution of velocity fields in a surrogate quasi-2D permeable medium using a microfluidic device, a microscopy system, and a high-speed camera. Tracer particles are injected into the medium along with DI water. The evolution of the velocity field is examined by tracing these particles in the captured images using the standard high-density particle image velocimetry algorithm founded on cross-correlation. The results suggest that the transition between steady states for an incompressible fluid takes a finite and non-negligible amount of time that is independent of the magnitude of the change in pressure gradient. The existence of transient states and the nature of the response during these states are readily interpreted by the principle of least action where flow gradually establishes an optimal configuration such that energy dissipation is 2 minimized. The findings provide evidence against the applicability of the assumption that flowing phases relax instantaneously to their steady states and, hence, against the accuracy of the classical multiphase extension of Darcy's law.

42 ENGINEERING↗

In situ x-ray photoelectron spectroscopy analysis of electrochemical interfaces in battery: Recent advances and remaining challenges

An in-depth understanding of charge transfer processes at the electrochemical interfaces is a critical knowledge gap impeding the design of energy storage materials. X-ray photoelectron spectroscopy plays an important role in analyzing electronic structures of heterogeneous interfaces, such as electrode-electrolyte interphases. Correspondingly, ex situ studies based on postmortem analysis of electrode materials using x-ray techniques are widely reported in the literature but often fail to capture intermediate and transient species, which are critical for a predictive understanding of the charge transfer process. The lack of extensive in situ/operando x-ray analysis of buried interfaces in energy storage systems can be mainly attributed to technical limitations, such as the requirement of high vacuum conditions. However, in the past decade, considerable efforts have been devoted to overcoming these technical barriers and enable investigation of the solid/solid and solid/liquid interfaces. This review catalogs some of the recent progresses and new experimental designs in the application of in situ and operando x-ray photoelectron spectroscopy toward characterizing interfacial processes and emergent properties, which can help build the design strategy for advanced batteries. The remaining challenges and future research directions are also discussed, as potential paths forward in this field.

Wi, Sungun↗

Evaluation of Increased Peak Temperatures for Spent Fuel Cladding Performance during Dry Storage (Rev.1)

NUREG-2214, “Managing Aging Processes in Storage (MAPS) Report,” (2019) documents the technical basis for age-related degradation mechanisms on spent nuclear fuel assemblies during dry storage operations. The technical bases have been reviewed, and hoop cladding stress calculations were conducted using the Fuel Analysis under Steady-state and Transients (FAST) code at elevated normal condition temperatures of 425°C and 450°C, and at an off-normal and accident conditions temperature of 600°C. The NUREG-2214 conclusions are substantiated by the referenced literature. The calculations demonstrate that the aging mechanisms primarily driven by hoop stress such as hydride reorientation, delayed hydride cracking, thermal and athermal (low-temperature) creep, and localized mechanical overload are either not credible or do not compromise the fuel assembly’s performance for increased peak normal condition temperatures of 425°C or 450°C during the up to 60-year dry storage period. Other aging mechanisms considered are also not credible for compromising the fuel assembly’s performance during 60-year dry storage with a peak temperature of 400ºC as specified in ISG – 11 Rev. 3, and the same is indicated for the increased peak normal condition temperatures of 425°C or 450°C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electrochemical Compression for Ammonia Storage and Refrigeration System (Phase 2)

In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm 2 of active area. We demonstrated the operation of larger cells with 100 cm 2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state.

25 ENERGY STORAGE↗

Fabrication, Modeling, and Testing of a Prototype for Particle Thermal Energy Storage Containment

Increasing penetration of variable renewable energy resources requires the deployment of energy storage at a range of durations. Long-duration energy storage (LDES) technologies will fulfill the need to firm variable renewable energy resource output throughout the year. Conventional electrochemical batteries (e.g., lithium-ion) are uneconomical in this role due to high energy capacity costs. Thermal energy storage (TES) is one promising technology for LDES applications because of its siting flexibility and ease of scaling. Particle-based TES systems use low-cost solid particles that have higher temperature limits than the molten salts used in traditional concentrated solar power systems. A key component in particle-based TES systems is the containment silo for the high-temperature (> 1100 degrees C) particles. This study combined experimental testing and computational modeling methods to design and characterize the performance of a particle containment silo for LDES applications. A containment silo prototype was built at a laboratory scale and used to validate a congruent transient finite element analysis (FEA) model. The validation compared the actual and predicted temperature profile through the prototype over six days as the particles cooled from their initial temperature. The performance of a commercial scale (> 5 GWhth) was then characterized using the validated model. The transient FEA model was subject to several charge-discharge cycles to mimic a possible operating schedule. The commercial-scale model predicted a storage efficiency in excess of 95% after five days of storage with a design storage temperature of 1200 degrees C. Insulation material and concrete temperature limits were considered as well. The validation of the methodology means the FEA model can simulate a range of scenarios for future applications. This work supports the development of a promising LDES technology with implications for grid-scale electrical energy storage, but also for thermal energy storage for industrial process heating applications.

ENERGY STORAGE↗

Using Energy Storage-Based Grid Forming Inverters for Operational Reserve in Hybrid Diesel Microgrids

In remote arctic communities, where access to a bulk electrical grid interconnection is not available, the implementation of islanded microgrids has been the most viable way to produce and distribute electricity services to their inhabitants. Historically, these islanded grids have relied primarily on diesel generators or hydropower resources to supply the baseload. However, this practice can result in increased expense due to the high costs associated with fuel transportation and the significant amounts of on-site storage necessary when fuel transportation is unavailable during winter months. In order to mitigate this problem, arctic microgrids have started to transition to a hybrid-source operational mode by incorporating renewable energy sources that are inherently variable in nature, such as wind or solar. Due to their highly stochastic behavior, these hybrid-source islanded microgrids can pose potential issues related to power quality due to introduction of rapid net load fluctuations and inability of diesel generators to respond rapidly. In addition, non-firm stochastic sources can require significant idling diesel generator resources to serve as spinning reserves, which is inefficient and wasteful. This work studies the problems that may arise in the transient dynamics of a real-world hybrid diesel microgrid when subjected to a loss of wind generation. Moreover, this work proposes a transition from a diesel spinning reserve to a battery energy-storage system (BESS) operating reserve scheme. The study of the proposed transition is important in establishing the fundamental implication of transient dynamics and the potential benefits of integrating a BESS as a spinning reserve in terms of stability, frequency nadir, and transient voltage deviation. The methods to investigate and validate the transient dynamics relied on both electromagnetic simulation models of GFMIs and a commercially available GFMI in an experimental power hardware-in-the-loop setup. The simulation results showed that the proposed operating reserve scheme improves the power quality of the system in terms of voltage deviation and frequency nadir when the microgrid is subjected to a loss of wind generation scenario. Depending on the simulation cases, adding a GFMI reduced the frequency nadir between 65.3% and 86.7%. Moreover, the reductions in the voltage deviations improved between 3.6% and 23.0%. From these results it can be concluded that the integration of a GFMI can reduce the frequency nadir in a hybrid diesel microgrid, and in turn, reduce diesel consumption, which improves system reliability while reducing fuel expenses. Furthermore, the novelty of this work relies on the fact that the offline simulation results were validated using a power hardware-in-the-loop platform that incorporated a 100 kVA commercially available GFMI as the device under test.

Hernandez-Alvidrez, Javier↗

Thermal Stress Modeling and Analysis of Packed-bed Thermocline Energy Storage Tank for INL Thermal Energy Distribution System (TEDS)

The Thermal Energy Distribution System (TEDS) at Idaho National Laboratory (INL) is a thermal-hydraulic flow loop to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit for TEDS. The packed-bed TES is adopted in TEDS because of its benefit as a low-cost single-tank storage option compared to the traditional two-tank storage. However, thermal ratcheting is one potential design concern which is caused by the rearrangement of granular filler inside a packed-bed tank during continuous thermal cycling operation of the packed-bed TES tank. If the thermally induced stress exceeds yield strength of the tank wall, it may cause catastrophic consequences like rupture of the thermal storage tank. Thus, it is crucial to understand the phenomenon to ensure the robust operation. Based on the temperature boundary conditions given by transient thermal analyses with computational fluid dynamics (CFD) simulations, the thermal ratcheting analysis is then conducted to evaluate the hoop stress and resultant thermal ratcheting potential of the TES tanks with two different modeling approaches: (1) infinite rigidity model and (2) Drucker-Prager (DP) model. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One Plant and evaluate the thermal ratcheting potential of the TEDS TES tank.

25 ENERGY STORAGE↗